Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Line Carrier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

104 records · Page 6

Using coronal loops to reconstruct the magnetic field of an active region before and after a major flare

The shapes of solar coronal loops are sensitive to the presence of electrical currents that are the carriers of the non-potential energy available for impulsive activity. We use this information in a new method for modeling the coronal magnetic field of active region (AR) 11158 as a nonlinear force-free field (NLFFF). The observations used are coronal images around the time of major flare activity on 2011 February 15, together with the surface line-of-sight magnetic field measurements. The data are from the Helioseismic and Magnetic Imager and Atmospheric Imaging Assembly on board the Solar Dynamics Observatory. The model fields are constrained to approximate the coronal loop configurations as closely as possible, while also being subject to the force-free constraints. The method does not use transverse photospheric magnetic field components as input and is thereby distinct from methods for modeling NLFFFs based on photospheric vector magnetograms. We validate the method using observations of AR 11158 at a time well before major flaring and subsequently review the field evolution just prior to and following an X2.2 flare and associated eruption. The models indicate that the energy released during the instability is about 1 × 10{sup 32} erg, consistent with what is needed to power such a large eruptive flare. Immediately prior to the eruption, the model field contains a compact sigmoid bundle of twisted flux that is not present in the post-eruption models, which is consistent with the observations. The core of that model structure is twisted by ≈0.9 full turns about its axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Raman Spectroscopy for the On Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of new combustion approaches such as chemical looping combustion (CLC). This process is based on using oxygen carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide the oxygen for the combustion process. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. Our goal is to develop a sensor for the on-line analysis of the oxidation state of oxygen carrier particles and to demonstrate its feasibility. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. The expected results are to be of a statistical nature, providing relative concentrations of the different oxidation states. These requirements make a strong case for using non-contact, stand-off, pulsed Raman spectroscopy as a sensor for the high-temperature on-line analysis of oxygen carrier particles. In order to achieve our goal, we have set up and tested a pulsed Raman spectroscopy system in combination with a pressurized high-temperature sample chamber, and have taking initial Raman spectra of various materials at high temperature. We are now in the process of optimizing the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, data acquisition, etc. We will also develop an analysis procedure for the interpretation of the Raman spectra. Typical Raman spectra consist of a convolution of background signal and multiple individual spectra. In order to extract relevant information such as the concentration ratio of a material in different oxidation states, we need to process (background subtraction, deconvolution, fitting, etc.) the measured data. In addition, statistical modeling and multivariate calibration need to be performed to correctly analyze the Raman spectra.

20 FOSSIL-FUELED POWER PLANTS↗

Circuit and Method for Communication Over DC Power Line

A circuit and method for transmitting and receiving on-off-keyed (OOK) signals with fractional signal-to-noise ratios uses available high-temperature silicon- on-insulator (SOI) components to move computational, sensing, and actuation abilities closer to high-temperature or high-ionizing radiation environments such as vehicle engine compartments, deep-hole drilling environments, industrial control and monitoring of processes like smelting, and operations near nuclear reactors and in space. This device allows for the networking of multiple, like nodes to each other and to a central processor. It can do this with nothing more than the already in-situ power wiring of the system. The device s microprocessor allows it to make intelligent decisions within the vehicle operational loop and to effect control outputs to its associated actuators. The figure illustrates how each node converts digital serial data to OOK 18-kHz in transmit mode and vice-versa in receive mode; though operations at lower frequencies or up to a megahertz are within reason using this method and these parts. This innovation s technique modulates a DC power bus with millivolt-level signals through a MOSFET (metal oxide semiconductor field effect transistor) and resistor by OOK. It receives and demodulates this signal from the DC power bus through capacitive coupling at high temperature and in high ionizing radiation environments. The demodulation of the OOK signal is accomplished by using an asynchronous quadrature detection technique realized by a quasi-discrete Fourier transform through use of the quadrature components (0 and 90 phases) of the carrier frequency as generated by the microcontroller and as a function of the selected crystal frequency driving its oscillator. The detected signal is rectified using an absolute-value circuit containing no diodes (diodes being non-operational at high temperatures), and only operational amplifiers. The absolute values of the two phases of the received signal are then summed and hard limited (digitized) by comparing them to a reference level and are then input into a microprocessor as a serial bit stream. The quasi-discrete Fourier transform is performed in high-temperature components (operational amplifiers, analog switches, resistors, and capacitors). The demodulated signal is a serial data stream that is input to the UART (universal asynchronous receiver transmitter) receiver pin of the microprocessor. The OOK of the carrier frequency uses the output of the UART pin as an enabling signal that drives the gate of the MOSFET. Logic low bits enable the carrier frequency (realized by using the 0 phase signal from the microcontroller, though either phase may be used) to be DC-coupled to the power supply bus through a current-limiting resistor mounted between the MOSFET drain and the supply rail. The presence of logic lows on the power supply rail is realized by carrier bursts while logic highs are realized by the absence of bursts.

Krasowski, Michael J.↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

The ISO View of Star Forming Galaxies

ISO studies of normal galaxies in the local Universe have revealed basic new properties whose significant implications for the star formation process and cosmology are only starting to be understood. This review will touch on the general results of a statistical nature, and provide a quick summary of the profusion of exciting results on individual objects. In the mid-infrared, PHT-S has established that the spectra of star forming galaxies between 6 and-13microns are dominated by the Aromatic Features in Emission (AFE), and show little variation as a function of the heating intensity. The Carriers of the AFE (CAFE) are thus a universal component of dust with standard properties, and contribute between 10 and 25% of the total dust luminosity. In addition to AFE, the spectra show a low-level continuum detectable at wavelengths longer than 3.5microns whose origin is still under investigation. The mid-infrared colors formed as the ratio of flux densities in the 6.75micron and the 15micron bands of ISO-CAM remain essentially constant and near unity for quiescent and mildly active galaxies. As dust heating increases further, the 15micron flux increases steeply compared to 6.75microns, indicating that dust heated to 100K<T<200K becomes a significant component. Such hot dust is presumably located within or just outside HII regions. At the other end of the spectrum, photometry at 120-200microns using ISO-PHOT is starting to constrain the distribution of dust temperatures at the low end of the temperature scale. From LWS data, the far-infrared fine-structure lines of [CII] and [OI], which provide most of the cooling for warm atomic gas, show variations that have remained controversial in their interpretation. In particular, as the galaxy become more active in star formation, its [CII] flux weakens relative to total dust emission while the [OI] does not. This behavior has attracted much interest because it extrapolates to the most active galaxies, making them weaker in [CII] than previously expected. Several explanations for the effect have been advanced, and will be discussed in this review. Spectroscopy with SWS has measured molecular hydrogen in galaxies, providing a powerful handle on the warm molecular gas content. SWS and CAM-CVF studies targeting ionic fine-structure lines have demonstrated their value as diagnostics of the radiation field.

Helou, George↗

Raman spectroscopy of oxygen carrier particles in harsh environments

Fossil fuel combustion processes generate CO2, a greenhouse gas of considerable concern. To reduce this emission, the National Energy Technology Laboratory (NETL) is evaluating alternative combustion approaches, including chemical looping combustion (CLC). This technique generates relatively pure CO2, suitable for subsequent capture and storage. CLC uses oxygen-carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide oxygen for the combustion process. Optimization of the overall combustion process requires knowledge of the oxidation state (e.g., content of Fe2O3 vs. Fe3O4) of the OCPs during the different stages of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of OCPs in harsh environments is lacking and new sensors need to be developed. We are evaluating non-contact, stand-off Raman spectroscopy to determine the relative concentrations of the oxidized and reduced forms of OCPs at temperatures between 800 °C and 1000 °C, and pressures of about 10 atm. Using cw and pulsed Raman spectroscopy, in combination with a pressurized high-temperature sample chamber, we have optimized the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, etc. and measured Raman spectra of various OCP materials at high temperatures. To extract from the Raman spectra relevant information such as the concentration ratio of a material in different oxidation states, the measured data needs to be processed, and statistical modeling and multivariate calibration need to be performed.

20 FOSSIL-FUELED POWER PLANTS↗

Generic modelling and optimal day-ahead dispatch of micro-energy system considering the price-based integrated demand response

As an extension of micro-grid, micro-energy system (MES) is one of the important carriers for energy utilization in the future, and using energy prices as a controllable resource is conducive to improving the optimization potential of MES. Firstly, based on the energy hub model, a generic method for modelling the steady-state energy balance equation of MES is proposed. Then, considering the multi-energy substitution effect in the background of multi-energy coupling, the concept of price-based integrated demand response (P-IDR) is introduced. Meanwhile, based on the price elasticity theory and the discrete choice theory, the energy timing transfer characteristics and energy substitution characteristics in P-IDR is modelled. Furthermore, after taking into account the P-IDR, an MINLP model for day-ahead dispatch of MES is built, and a generalized benders decomposition method is used for solution. Case studies are conducted on an MES to verify the effectiveness of the proposed modelling method. Here, the result shows that it is beneficial to improve renewable energy accommodation and reduce the peak and off-peak difference of energy load when the P-IDR is deployed. In addition, consider the energy substitution characteristics can reduce the user’s cost on energy purchase and be more in line with the user’s rational consumption behaviour.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Ga 2 O 3 as a new transparent conductive oxide for photovoltaics applications

This small innovation project intended to leverage recent activity and advances in ultrawide-bandgap oxide power electronics toward the investigation of Ga 2 O 3 as a transparent conductive oxide (TCO) for use in photovoltaics (PV). Ga 2 O 3 ’s theoretical advantage over incumbent TCOs is its very large bandgap of 4.8 eV, ensuring optical transparency of photons with λ ≥ 260 nm, effectively the full terrestrial solar spectrum. At the time of proposal writing, literature on Ga 2 O 3 as a TCO/optical material was relatively sparse — what little existed was focused on for UV sensors and/or emitters, with none related to PV. As such, this project was intended to help determine the potential of Ga 2 O 3 as a PV-oriented TCO by investigating its deposition using tools common to the PV and electronics industries — atomic layer deposition (ALD) and RF sputtering (RS), both of which are already used in PV manufacturing — and its resultant optical and electronic properties. Final project goals were to test its application to Si and III-V solar cells. Controllable film thickness and excellent uniformity was established for both methods deposition methods, with ALD providing higher precision for thinner films and RS more effective for growing thicker films. The as-deposited films were found to be amorphous in nature. Spectroscopic ellipsometry (SE) confirmed bandgaps of at least 4.8 eV and non-parasitic absorption across both AM0 and AM1.5G spectra; a refractive index approaching the expected value of 1.8 was also observed, with some degree of tunability based on process parameters. Using this initial optical data, a transfer matrix model, which interfaces with in-house EQE and LIV models, was developed to simulate Ga 2 O 3 optical effects on various solar cells, included potential in antireflection coatings (ARCs). Despite promising optical properties, the resultant resistivity / conductivity metrics did not meet expectations, regardless of deposition process. Although thick RS-deposited films, using both undoped and 1 at% Ge (n-type) doped sintered targets — demonstrated high net carrier concentrations (via C-V), and low specific resistance Ohmic contacts were demonstrated, transmission line measurements (TLM) showed very high resistivity. Further analysis indicated high vertical film conductivity, but very low lateral conductivity. Deeper characterization revealed a relatively high density of nano/microcrystalline inclusions that were ostensibly the source of the vertical conductivity, with the amorphous matrix serving as an effective insulator (likely due to high concentrations of electronic trap states). Despite extensive work to increase film polycrystallinity — demonstrated via high temperature annealing — sufficient lateral conductivity for TCO use was not achieved. The final phase of the project shifted focus toward investigation of ALD-deposited Ga 2 O 3 ’s potential as a passivant and/or passivating contact for both Si and III-V solar cells, with expectation of performance similar to Al 2 O 3 . However, initial rounds of testing using our baseline ALD process yielded minimal (but not quite zero) passivation of both GaInP and Si surfaces. Dielectric passivation is well-known to be highly process sensitive; given the unoptimized nature of the process used, this work was deemed inconclusive. The final outlook with respect to feasibility of Ga 2 O 3 as a PV-oriented TCO is, ultimately, still uncertain. The work performed in this project confirmed the optical properties and deposition methods, but the achieved electrical properties do not meet technological needs; literature reports in recent years are somewhat inconsistent and potentially untrustworthy, but generally appear to be in line with our results. At the very least it is clear that, should Ga 2 O 3 still be under consideration for PV TCO and/or selective contact applications, a significant amount of optimization and study is still needed.

14 SOLAR ENERGY↗

Wireless Integrated Microelectronic Vacuum Sensor System

NASA Stennis Space Center's (SSC's) large rocket engine test facility requires the use of liquid propellants, including the use of cryogenic fluids like liquid hydrogen as fuel, and liquid oxygen as an oxidizer (gases which have been liquefied at very low temperatures). These fluids require special handling, storage, and transfer technology. The biggest problem associated with transferring cryogenic liquids is product loss due to heat transfer. Vacuum jacketed piping is specifically designed to maintain high thermal efficiency so that cryogenic liquids can be transferred with minimal heat transfer. A vacuum jacketed pipe is essentially two pipes in one. There is an inner carrier pipe, in which the cryogenic liquid is actually transferred, and an outer jacket pipe that supports and seals the vacuum insulation, forming the "vacuum jacket." The integrity of the vacuum jacketed transmission lines that transfer the cryogenic fluid from delivery barges to the test stand must be maintained prior to and during engine testing. To monitor the vacuum in these vacuum jacketed transmission lines, vacuum gauge readings are used. At SSC, vacuum gauge measurements are done on a manual rotation basis with two technicians, each using a handheld instrument. Manual collection of vacuum data is labor intensive and uses valuable personnel time. Additionally, there are times when personnel cannot collect the data in a timely fashion (i.e., when a leak is detected, measurements must be taken more often). Additionally, distribution of this data to all interested parties can be cumbersome. To simplify the vacuum-gauge data collection process, automate the data collection, and decrease the labor costs associated with acquiring these measurements, an automated system that monitors the existing gauges was developed by Invocon, Inc. For this project, Invocon developed a Wireless Integrated Microelectronic Vacuum Sensor System (WIMVSS) that provides the ability to gather vacuum-gauge measurements automatically and wirelessly, in near-real time - using a low-maintenance, lowpower sensor mesh network. The WIMVSS operates by using a self-configuring mesh network of wireless sensor units. Mesh networking is a type of networking where each sensor or node can capture and disseminate its own data, but also serve as a relay to receive and transmit data from other sensors. Each sensor node can synchronize with adjacent sensors, and propagate data from one sensor to the next, until the destination is reached. In this case, the destination is a Network Interface Unit (NIU). The WIMVSS sensors are mounted on the existing vacuum gauges. Information gathered by the sensors is sent to the NIU. Because of the mesh networking, if a sensor cannot directly send the data to the NIU, it can be propagated through the network of sensors. The NIU requires antenna access to the sensor units, AC power, and an Ethernet connection. The NIU bridges the sensor network to a WIMVSS server via an Ethernet connection. The server is configured with a database, a Web server, and proprietary interface software that makes it possible for the vacuum measurements from vacuum jacketed fluid lines to be saved, retrieved, and then displayed from any Web-enabled PC that has access to the Internet. Authorized users can then simply access the data from any PC with Internet connection. Commands can also be sent directly from the Web interface for control and maintenance of the sensor network. The technology enabled by the WIMVSS decreases labor required for gathering vacuum measurements, increases access to vacuum data by making it available on any computer with access to the Internet, increases the frequency with which data points can be acquired for evaluating the system, and decreases the recurring cost of the sensors by using off-the-shelf components and integrating these with heritage vacuum gauges.

Krug, Eric↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C. Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers. Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C. Mixtures of Fe 2 O 3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm. Copper oxides did not yield suitable signals at elevated temperatures. The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Roles and Responsibilities for Distribution Grids: DER Sensing and Communication Networks

Traditional distribution grids require sensing and communications for grid operations. In many cases the communications networks are owned by the Distribution Operator (DO); in some cases, carrier services such as leased telephone land lines or cellular services are used. In recent years, wireless mesh field area networks and optical fiber have become viable options for distribution. Fiber in particular has improved in cost to the point where its high performance (large bandwidth, low latency, and low packet loss) has become practical for distribution systems where geographic circumstances permit. As grid modernization proceeds, utilities find a need to improve or upgrade distribution communications; this represents a significant investment and it is natural that both utilities and regulators would seek both to future-proof and minimize their costs. Given the development and rising penetration of smart grid edge devices such as Distributed Energy Resources (DER) that have local sensing and intelligence and can communicate via the internet or other non-utility communications channels to cloud-based services, the idea of using such devices for grid sensing and communications to support grid operations has emerged as a potential means to avoid utility investment. To a great extent, however, these DER and communication channels will be owned and operated not by the DO but by end-use customers, aggregators and other third parties pursuing their own energy needs and business models. The question of whether such devices and systems can effectively substitute for DO grid modernization investment can be assessed and resolved using grid architecture methods and by considering the appropriate roles and responsibilities of the entities and systems involved in distribution grid operations. This approach reveals that there are several compelling reasons to dismiss the idea of eliminating DO owned and operated sensing and communication entirely and relying on DER-based sensing and third party communications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Envera Variable Compression Ratio Engine

Aggressive engine downsizing, variable compression ratio and use of the Atkinson cycle are being combined to improve fuel economy by up to 40 percent relative to port fuel injected gasoline engines, while maintaining full engine power. Approach Engine downsizing is viewed by US and foreign automobile manufacturers as one of the best options for improving fuel economy. While this strategy has already demonstrated a degree of success, downsizing and fuel economy gains are currently limited. With new variable compression ratio technology however, the degree of engine downsizing and fuel economy improvement can be greatly increased. A small variable compression ratio (VCR) engine has the potential to return significantly higher vehicle fuel economy while also providing high power. Affordability and potential for near term commercialization are key attributes of the Envera VCR engine. VCR Technology To meet torque and power requirements, a smaller engine needs to do more work per stroke. This is typically accomplished by boosting the incoming charge with either a turbo or supercharger so that more energy is present in the cylinder per stroke to do the work. With current production engines the degree of engine boosting (which correlates to downsizing) is limited by detonation (combustion knock) at high boost levels. Additionally, the turbo or supercharger needs to be responsive and efficient while providing the needed boost. VCR technology eliminates the limitation of engine knock at high load levels by reducing compression ratio to {approx}9:1 (or whatever level is appropriate) when high boost pressures are needed. By reducing the compression ratio during high load demand periods there is increased volume in the cylinder at top dead center (TDC) which allows more charge (or energy) to be present in the cylinder without increasing the peak pressure. Cylinder pressure is thus kept below the level at which the engine would begin to knock. When loads on the engine are low the compression ratio can be raised (to as much as 18:1) providing high engine efficiency. It is important to recognize that for a well designed VCR engine cylinder pressure does not need to be higher than found in current production turbocharged engines. As such, there is no need for a stronger crankcase, bearings and other load bearing parts within the VCR engine. The Envera VCR mechanism uses an eccentric carrier approach to adjust engine compression ratio. The crankshaft main bearings are mounted in this eccentric carrier or 'crankshaft cradle' and pivoting the eccentric carrier 30 degrees adjusts compression ratio from 9:1 to 18:1. The eccentric carrier is made up of a casting that provides rigid support for the main bearings, and removable upper bearing caps. Oil feed to the main bearings transits through the bearing cap fastener sockets. The eccentric carrier design was chosen for its low cost and rigid support of the main bearings. A control shaft and connecting links are used to pivot the eccentric carrier. The control shaft mechanism features compression ratio lock-up at minimum and maximum compression ratio settings. The control shaft method of pivoting the eccentric carrier was selected due to its lock-up capability. The control shaft can be rotated by a hydraulic actuator or an electric motor. The engine shown in Figures 3 and 4 has a hydraulic actuator that was developed under the current program. In-line 4-cylinder engines are significantly less expensive than V engines because an entire cylinder head can be eliminated. The cost savings from eliminating cylinders and an entire cylinder head will notably offset the added cost of the VCR and supercharging. Replacing V6 and V8 engines with in-line VCR 4-cylinder engines will provide high fuel economy at low cost. Numerous enabling technologies exist which have the potential to increase engine efficiency. The greatest efficiency gains are realized when the right combination of advanced and new technologies are packaged together to provide the greatest gains at the least cost. Aggressive engine downsizing with variable compression ratio and use of the extended Atkinson cycle can provide large fuel economy gains that are exceptionally cost effective. Analysis indicates that a 2.2L supercharged Envera VCR engine can match the torque of a larger V8 engine at 2000 rpm. The VCR engine's high torque value at low engine speed is beneficial for maintaining the driving feel and responsiveness of the larger V8 engine. The Envera VCR engine will attain high efficiency at {approx}100 Nm primarily due to the combination of engine down-sizing and use of the Atkinson cycle. Qualitatively the fuel economy gain realized from down-sizing from a V8 to an Atkinson-cycle I-4 is about twice as large as the benefits from down-sizing from a V8 to a Turbo V6 when evaluated at 100 Nm 2000 rpm.

33 ADVANCED PROPULSION SYSTEMS↗

Computational Study of Flow Interactions in Coaxial Rotors

Although the first idea of coaxial rotors appeared more than 150 years ago, most helicopters have used single main-rotor/tail-rotor combination. Since reactive moments of coaxial rotors are canceled by contra-rotation, no tail rotor is required to counter the torque generated by the main rotor. Unlike the single main rotor design that distributes power to both main and tail rotors, all of the power for coaxial rotors is used for vertical thrust. Thus, no power is wasted for anti-torque or directional control. The saved power helps coaxial rotors reach a higher hover ceiling than single rotor helicopters. Another advantage of coaxial rotors is that the overall rotor diameter can be reduced for a given vehicle gross weight because each rotor provides a maximum contribution to vertical thrust to overcome vehicle weight. However, increased mechanical complexity of the hub has been one of the challenges for manufacturing coaxial rotorcraft. Only the Kamov Design Bureau of Russia had been notably successful in production of coaxial helicopters until Sikorsky built X2, an experimental compound helicopter. Recent developments in unmanned aircraft systems and high-speed rotorcraft have renewed interest in the coaxial configuration. Multi-rotors are frequently used for small electric unmanned rotorcraft partly due to mechanical simplicity. The use of multiple motors provides redundancy as well as cost-efficiency. The multi-rotor concept has rarely been used until recently because of its inherent stability and control problems. However, advances in inexpensive electronic flight control systems have opened the floodgates for small drones using multirotors. Coaxial rotors have started to appear in some multi-rotor configurations. Small coaxial rotors have often been designed using a hundred year old approach that is "sketch, build, fly, and iterate." In that approach, there is no systematic way to explore trade-offs or determine logical next steps. It is neither possible to account for multiple real-world constraints up front in design nor possible to know what performance is possible with a given design. Since unmanned vehicles are sized and optimized for the particular mission, a modern low-fidelity conceptual design and sizing tool that has been used for the design of large helicopters can be used for design of small coaxial rotorcraft. However, unlike most helicopters with single main rotor, the interactions between the upper and lower rotors emerge as an important factor to consider in design because an increase in performance of a multi-rotor system is not proportional to the number of rotors. Interference losses and differences in thrusts between the upper and lower rotors were investigated by theoretical methods as well as a computational fluid dynamics (CFD) method using the Reynolds-Averaged Navier-Stokes (RANS) equations. In this work, hybrid turbulence models are used to investigate the physics of interactions between coaxial rotors and a fuselage that are not well understood. Present study covers not only small-scale drones but also large-scale coaxial rotors for heavy-lifting missions. Considering the recently proposed FAA drone rules that require the flight only in visual line-of-sight, a large multirotor might be used as an airborne carrier for launch and recovery of unmanned aircraft systems with a human operator onboard. For applications to civil operations, their aerodynamic performance and noise levels need to be assessed. Noise is one of the largest limiting factors to rotorcraft operations in urban area. Since the high-frequency noise of multi-rotors may increase the annoyance, noise may turn out to be a key issue that must be addressed for market acceptability. One of the objectives of the present work is to study the effects of inter-rotor spacing and collectives on the performance, efficiency, and acoustics of coaxial rotor systems.

Study↗