Mercury Calibration System

Abstract

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Schabron, John, Kalberer, Eric, Rovani, Joseph, Sanderson, Mark, Boysen, Ryan, Schuster, William. 2009-03-11. Mercury Calibration System. https://doi.org/10.2172/993821

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Wyoming Trails Carbon Hub (WyoTCH)

The Wyoming Trails Carbon Hub (WyoTCH) project completed a front-end engineering and design (FEED) study for a commercial-scale, open-access carbon dioxide (CO 2 ) transport pipeline in Wyoming under U.S. Department of Energy (DOE) Award DEFE0032347, funded through the Bipartisan Infrastructure Law Carbon Capture Technology Program and administered by the National Energy Technology Laboratory. The project’s approach of designing a multi-source, multi-destination pipeline, rather than a dedicated line serving a single project, would lower the barrier to entry for individual CO 2 projects. The projects would leverage Wyoming's concentrated industrial and power generation CO 2 sources, its existing CO 2 pipeline infrastructure, and its extensive CO 2 storage and utilization capacity. This is the project's final technical report.

01 COAL, LIGNITE, AND PEAT↗

Engineering-Scale Validation of Novel Algae CO 2 Capture and Bioproducts Technology

The purpose of this project was to advance and scale the algae-based technology Helios-NRG has been developing for capture of CO 2 from the flue gas of coal-burning power plants with conversion of the CO 2 to high-value products. In order to encourage the process becoming commercial and be adoptable, it is essential that the cost of CO 2 be close to net zero or slightly revenue positive. Two methods to achieve this are reducing the cost of operations through efficiencies and selling of products derived from conversion. Helios and the project team partners have accomplished the goals of furthering the technology to be more scalable and substantially lower cost with a defined pathway for commercialization.

01 COAL, LIGNITE, AND PEAT↗

Innovative Biomonitoring and Remediation of Heavy Metals Using Phytotechnologies at the Savannah River Site (SRS) Coal Combustion Product (CCP) Impoundment Sites

The Savannah River Site (SRS) contains legacy coal combustion product (CCP) impoundments that are impacted by elevated concentrations of heavy metals and radionuclides, posing long-term risks to soil health, ecosystem functioning, and environmental sustainability. Traditional environmental monitoring approaches rely primarily on chemical analyses to quantify contaminant concentrations but often provide limited information regarding biological responses or ecosystem recovery. This project addressed these limitations by integrating environmental chemistry, microbial ecology, artificial intelligence (AI), and bioremediation into a comprehensive framework for environmental diagnostics and restoration of contaminated soils. The overarching goal of this collaborative project between Florida A&M University (FAMU) and the University of Georgia's Savannah River Ecology Laboratory (SREL) was to develop innovative biomonitoring and remediation strategies for heavy metal-contaminated CCP impoundment sites at the Savannah River Site. Specifically, the project sought to (i) characterize heavy metal contamination, (ii) determine microbial responses to contamination, (iii) isolate indigenous heavy metal-resistant microorganisms for remediation applications, (iv) develop a microbial ecological health index using machine learning, and (v) optimize fungal-mediated bioremediation using artificial intelligence.

01 COAL, LIGNITE, AND PEAT↗