Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of process-induced damage in Cu/low-k interconnect structure by microscopic infrared spectroscopy with polarized infrared light

Microscopic Fourier-transform infrared (FT-IR) spectra are measured for a Cu/low-k interconnect structure using polarized IR light for different widths of low-k spaces and Cu lines, and for different heights of Cu lines, on Si substrates. Although the widths of the Cu line and the low-k space are 70 nm each, considerably smaller than the wavelength of the IR light, the FT-IR spectra of the low-k film were obtained for the Cu/low-k interconnect structure. A suitable method was established for measuring the process-induced damage in a low-k film that was not detected by the TEM-EELS (Transmission Electron Microscope-Electron Energy-Loss Spectroscopy) using microscopic IR polarized light. Based on the IR results, it was presumed that the FT-IR spectra mainly reflect the structural changes in the sidewalls of the low-k films for Cu/low-k interconnect structures, and the mechanism of generating process-induced damage involves the generation of Si-OH groups in the low-k film when the Si-CH{sub 3} bonds break during the fabrication processes. The Si-OH groups attract moisture and the OH peak intensity increases. It was concluded that the increase in the OH groups in the low-k film is a sensitive indicator of low-k damage. We achieved the characterization of the process-induced damage that was not detected by the TEM-EELS and speculated that the proposed method is applicable to interconnects with line and space widths of 70 nm/70 nm and on shorter scales of leading edge devices. The location of process-induced damage and its mechanism for the Cu/low-k interconnect structure were revealed via the measurement method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A framed, 16-image Kirkpatrick–Baez x-ray microscope

A 16-image Kirkpatrick–Baez (KB)–type x-ray microscope consisting of compact KB mirrors has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ~30 ps. Images are arranged four to a strip with ~60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ~15 ps is achieved. A framed resolution of ~6-um is achieved with this combination in a 400-um region of laser–plasma x-ray emission in the 2- to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester’s OMEGA Laser System. The unprecedented time and spatial resolution achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. In conclusion, these core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 GBar in OMEGA cryogenic target implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A modular ultra-high vacuum millikelvin scanning tunneling microscope

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our design is to achieve a high level of modularity by partitioning the STM system into a set of easily separable, interchangeable components. This naturally segregates the UHV needs of STM instrumentation from the typically non-UHV construction of a dilution refrigerator, facilitating the usage of non-UHV materials while maintaining a fully bakeable UHV chamber that houses the STM. Here, the modular design also permits speedy removal of the microscope head from the rest of the system, allowing for repairs, modifications, and even replacement of the entire microscope head to be made at any time without warming the cryostat or compromising the vacuum. Without using cryogenic filters, we measured an electron temperature of 184 mK on a superconducting Al(100) single crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an ultrafast wide-field microscope for single-shot laser-driven shock and ablation studies

We build an ultrafast wide-field microscope that captures single-shot events at near-optical diffraction limit for time-resolved studies of ablation and shock compression. Here, we provide insights on how the imaging and spectroscopic modalities of our single-shot microscope are impacted by the depth of field of a microscope objective. At high spatial resolution, the depth of field can critically impede these experiments and novel strategies must be implemented to acquire high-quality optical micrographs at high throughput. Here, we highlight how custom lithography-prepared samples enable us to rectify optical artifacts that arise during sample motion. With a complete knowledge of how the mechanical and optical components couple together, we can then extract critical spatial and temporal features of our ablation and shock compression experiments. For example, during the ablation processes, we show that shock waves created in metal thin films form Newton’s interference rings, whose evolution can be recorded with picosecond temporal resolution and at near optical diffraction-limit resolution.

Ultrafast microscopy↗

Microscopic dynamics underlying the stress relaxation of arrested soft materials

Arrested soft materials such as gels and glasses exhibit a slow stress relaxation with a broad distribution of relaxation times in response to linear mechanical perturbations. Although this macroscopic stress relaxation is an essential feature in the application of arrested systems as structural materials, consumer products, foods, and biological materials, the microscopic origins of this relaxation remain poorly understood. Here, we elucidate the microscopic dynamics underlying the stress relaxation of such arrested soft materials under both quiescent and mechanically perturbed conditions through X-ray photon correlation spectroscopy. By studying the dynamics of a model associative gel system that undergoes dynamical arrest in the absence of aging effects, we show that the mean stress relaxation time measured from linear rheometry is directly correlated to the quiescent superdiffusive dynamics of the microscopic clusters, which are governed by a buildup of internal stresses during arrest. We also show that perturbing the system via small mechanical deformations can result in large intermittent fluctuations in the form of avalanches, which give rise to a broad non-Gaussian spectrum of relaxation modes at short times that is observed in stress relaxation measurements. These findings suggest that the linear viscoelastic stress relaxation in arrested soft materials may be governed by nonlinear phenomena involving an interplay of internal stress relaxations and perturbation-induced intermittent avalanches.

36 MATERIALS SCIENCE↗

Nuclear shape evolution based on microscopic level densities

Here, by combining microscopically calculated level densities with the Metropolis walk method, we develop a consistent framework for treating the energy and angular-momentum dependence of the nuclear shape evolution in the fission process. For each nucleus under consideration, the level density is calculated microscopically for each of more than five million shapes with a recently developed combinatorial method. The method employs the same single-particle levels as those used for the extraction of the pairing and shell contributions to the macroscopic-microscopic deformation-energy surface. Containing no new parameters, the treatment is suitable for elucidating the energy dependence of the dynamics of warm nuclei on pairing and shell effects. It is illustrated for the fission fragment mass distribution for several uranium and plutonium isotopes of particular interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic core-quasiparticle coupling model for spectroscopy of odd-mass nuclei

Predictions of the spectroscopic properties of low-lying states are critical for nuclear structure studies but are problematic for nuclei with an odd nucleon due to the interplay of the unpaired single particle with nuclear collective degrees of freedom. To predict the spectroscopic properties of odd-mass medium-heavy and heavy nuclei with a model that treats single-particle and collective degrees of freedom within the same microscopic framework. A microscopic core-quasiparticle coupling (CQC) model based on the covariant density functional theory is developed that contains the collective excitations of even-mass cores and spherical single-particle states of the odd nucleon as calculated from a quadrupole collective Hamiltonian combined with a constrained triaxial relativistic Hartree-Bogoliubov model. Additionally, predictions of the new model for excitation energies, kinematic and dynamic moments of inertia, and transition rates are shown to be in good agreement with results of low-lying spectroscopy measurements of the axially deformed odd-proton nucleus 159 Tb and the odd-neutron nucleus 157 Gd. A microscopic CQC model based on covariant density functional theory is developed for odd-mass nuclei and shown to give predictions that agree with measurements of two medium-heavy nuclei. Future studies with additional nuclei are planned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic theory of angular momentum distributions across the full range of fission fragments

Modern nuclear theory provides qualitative insights into the fundamental mechanisms of nuclear fission and is increasingly capable of making reliable quantitative predictions. Most quantities of interest pertain to the primary fission fragments, whose subsequent decay is typically modeled using statistical reaction models. Consequently, a key objective of fission theory is to inform these models by predicting the initial conditions of the primary fragments. Here, in this work, we employ a framework that combines joint angular momentum and particle number projection with time-dependent configuration mixing to calculate the angular momentum distributions of primary fragments. Focusing on the benchmark cases of neutron-induced fission of 235 U and 239 Pu , we predict—for the first time—microscopic angular momentum distributions for all fragments observed in experiments. Our results reveal a pronounced sawtooth pattern in the average angular momentum as a function of fragment mass, consistent with recent measurements. Additionally, we observe substantial variations in angular momentum distributions along isobaric chains, indicating that commonly used empirical formulas lack sufficient accuracy. We also quantify a strong correlation between the angular momentum and the deformation of the fragments at scission, and a weak correlation in the magnitude of the angular momentum between fragment partners. The generated data will enable estimation of the impact of microscopic distributions on fission spectra, paving the way toward fission modeling based on microscopic inputs.

Physics - Nuclear physics and radiation physics↗

Design and performance of an X-ray scanning microscope at the Hard X-ray Nanoprobe beamline of NSLS-II

A hard X-ray scanning microscope installed at the Hard X-ray Nanoprobe beamline of the National Synchrotron Light Source II has been designed, constructed and commissioned. The microscope relies on a compact, high stiffness, low heat dissipation approach and utilizes two types of nanofocusing optics. It is capable of imaging with ~15 nm × 15 nm spatial resolution using multilayer Laue lenses and 25 nm × 26 nm resolution using zone plates. Fluorescence, diffraction, absorption, differential phase contrast, ptychography and tomography are available as experimental techniques. The microscope is also equipped with a temperature regulation system which allows the temperature of a sample to be varied in the range between 90 K and 1000 K. The constructed instrument is open for general users and offers its capabilities to the material science, battery research and bioscience communities.

36 MATERIALS SCIENCE↗

Design-to-Deployment Continuum Platform for Microscopes and Computing Ecosystems

Science ecosystems with networked computing systems and physical instruments are increasingly being deployed with a goal to achieve the productivity promised by AI-supported remote automation. In support of these efforts, the virtual infrastructure twins (VITs) have been successfully utilized to develop the orchestration codes for these ecosystems without requiring physical access to expensive instruments, such as electron microscopes. Currently, the utility of such a VIT is severely limited by the computing capacity and capability of the computing system used as its host. Furthermore, codes developed on the VIT typically need to be transferred and refactored for production use, particularly, on high-performance systems with accelerators. In response, we develop a design-to-deployment continuum platform wherein a VIT runs natively on the ecosystem's own computing system, and thereby facilitates the continual in-situ testing and transition of codes for production use. Here, we describe the development and testing of software for remote microscope steering and GPU-based image reconstruction using this platform on a multi-GPU computing system networked to Nion microscopes. We demonstrate a continual transition of steering and reconstruction codes developed under VIT platform to production ecosystem deployment.

Al-Najjar, Anees [Oak Ridge National Laboratory (O↗

Mask-side Hyper-NA EUV imaging on the SHARP microscope

Hyper-NA, the prospective successor to high-numerical aperture (NA) extreme ultraviolet lithography (EUVL) could be inserted soon after 2030. Hyper-NA poses a number of challenges, including reduced depth of focus, amplified mask three-dimensional effects, and increased mask-side angular range. A Hyper-NA capable extreme ultraviolet (EUV) mask-imaging tool can address these challenges and accelerate research and development toward Hyper-NA. The Sharp High-Numerical Aperture Actinic Reticle Review Project (SHARP) EUV mask microscope is supporting mask-side high-NA imaging since 2015. Implementing mask-side Hyper-NA imaging in 2024 enables research and development toward the corresponding nodes of EUVL. Hyper-NA zoneplates at 0.75 4x/8x NA with a 6.7-deg chief ray angle and 0.85 4x/8x NA with a 7.4-deg chief ray angle are added to the SHARP microscope. Imaging at mask-side Hyper-NA is demonstrated. Imaging of 5-nm half-pitch (wafer scale) horizontal lines and spaces is demonstrated using dipole illumination. Imaging of 5-nm half-pitch (wafer scale) vertical lines and spaces is demonstrated using frequency-doubled imaging of 40-nm hp (mask scale) lines and spaces. Normalized image log slope (NILS) and modulation of Hyper-NA image data match closely to simulations for horizontal lines and spaces. A reduction in NILS of 0.3 or less is observed for vertical lines and spaces in the two-beam imaging regime. Through-focus image data are discussed, comparing different dipole sources and mask-side NAs. Mask-side Hyper-NA photomask imaging has been implemented and demonstrated on the SHARP microscope and is now available to users of the instrument.

Benk, Markus↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Elemental and topographical imaging of microscopic variations in deposition on NSTX-U and DIII-D samples

Tokamak plasma facing components have surface roughness that can cause microscopic spatial variations in erosion and deposition and hence influence material migration, erosion lifetime, dust and tritium accumulation, and plasma contamination. However high spatial resolution measurements of deposition on the scale of the surface roughness have been lacking to date. We will present elemental images of graphite samples from NSTX-U and DIII-D DiMES experiments performed with a Scanning Auger Microprobe at sub-micron resolution that show strong microscopic variations in deposition and correlate this with 3D topographical maps of surface irregularities. The NSTX-U samples were boronized and exposed to deuterium plasmas and the DiMES samples had localized Al and W films and were exposed to dedicated helium plasmas. Topographical maps of the samples were performed with a 3D confocal optical microscope and compared to the elemental deposition pattern. The results revealed localized deposition concentrated in areas shadowed from the ion flux, incident in a direction calculated (for the DiMES case) by taking account of the magnetic pre-sheath.

Surface analysis↗

Elemental and topographical imaging of microscopic variations in deposition on NSTX-U and DIII-D samples2

Abstract: Tokamak plasma facing components have surface roughness that can cause microscopic spatial variations in erosion and deposition and hence influence material migration, erosion lifetime, dust and tritium accumulation, and plasma contamination. However high spatial resolution measurements of deposition on the scale of the surface roughness have been lacking to date. We will present elemental images of graphite samples from NSTX-U and DIII-D DiMES experiments performed with a Scanning Auger Microprobe at sub-micron resolution that show strong microscopic variations in deposition and correlate this with 3D topographical maps of surface irregularities. The NSTX-U samples were boronized and exposed to deuterium plasmas and the DiMES samples had localized Al and W films and were exposed to dedicated helium plasmas. Topographical maps of the samples were performed with a 3D confocal optical microscope and compared to the elemental deposition pattern. The results revealed localized deposition concentrated in areas shadowed from the ion flux, incident in a direction calculated (for the DiMES case) by taking account of the magnetic pre-sheath.

Erosion, Deposition, NSTX-U, DIMES, Plasma-Materia↗

Tailored approach to study Legionella infection using a lattice light sheet microscope (LLSM)

Legionella is a genus of ubiquitous environmental pathogens found in freshwater systems, moist soil, and composted materials. More than four decades of Legionella research has provided important insights into Legionella pathogenesis. Although standard commercial microscopes have led to significant advances in understanding Legionella pathogenesis, great potential exists in the deployment of more advanced imaging techniques to provide additional insights. The lattice light sheet microscope (LLSM) is a recently developed microscope for 4D live cell imaging with high resolution and minimum photo-damage. We built a LLSM with an improved version for the optical layout with two path-stretching mirror sets and a novel reconfigurable galvanometer scanner ( RGS ) module to improve the reproducibility and reliability of the alignment and maintenance of the LLSM. We commissioned this LLSM to study Legionella pneumophila infection with a tailored workflow designed over instrumentation, experiments, and data processing methods. Our results indicate that Legionella pneumophila infection is correlated with a series of morphological signatures such as smoothness, migration pattern and polarity both statistically and dynamically. Our work demonstrates the benefits of using LLSM for studying long-term questions in bacterial infection. Our free-for-use modifications and workflow designs on the use of LLSM system contributes to the adoption and promotion of the state-of-the-art LLSM technology for both academic and commercial applications.

59 BASIC BIOLOGICAL SCIENCES↗

A self-driving microscope and the Atomic Forge

The electron microscope predates the transistor and the charge-coupled device (CCD). The opportunity to integrate these advancements into the electron microscope was seized and revolutionized in the modern (scanning) transmission electron microscope (STEM). Real-time analysis became possible and is now routine. Consider the efforts one would have to undertake to perform a Fourier transform in the days when images were acquired by exposing photographic plates. Indeed, it was real-time data analysis that enabled the measurement and correction of aberrations in modern instrumentation.1 What are the next opportunities on the horizon for the STEM?

36 MATERIALS SCIENCE↗