Multiple-foil microabrasion package (A0023)

The specific scientific objectives of this experiment are to measure the spatial distribution, size, velocity, radiance, and composition of microparticles in near-Earth space. The technological objectives are to measure erosion rates resulting from microparticle impacts and to evaluate thin-foil meteor 'bumpers'. The combinations of sensitivity and reliability in this experiment will provide up to 1000 impacts per month for laboratory analysis and will extend current sensitivity limits by 5 orders of magnitude in mass.

Mcdonnell, J. A. M.↗

Study of meteoroid impact craters on various materials (AO 138-1). Attempt at dust debris collection with stacked detectors (AO 138-2)

Part of the Long Duration Exposure Facility (LDEF) tray allocated to French experiments, known as FRECOPA payload, was devoted to the study of dust particles. Two passive experiments were flown: one composed of a set of glass and metallic samples and one composed of multilayer thin foils detectors. In addition to these experiments, a broad variety of materials were exposed to the bombardment of microparticles and provide more data. Thick target experiment comprises selected metallic (Al, Au, Cu, W, Stainless Steel) 250 microns thick and glass surfaces 1.5 mm thick. Crater size distribution from these thick target experiments enable, with the aid of lab calibrations by solid particle accelerators, the evaluation of the incident microparticle flux in the near earth environment. The aim of the multiple foil penetration and collection experiment is primarily to study the feasibility of multilayer thin film detectors acting as energy sorters in order to collect micrometeoroids, if not in their original shape, at least as 'breakup' fragments suitable for chemical analysis. Foil thicknesses range from 0.75 to 5 microns of Al.

Mandeville, Jean Claude↗

Analysis of Interplanetary Dust Experiment Detectors and Other Witness Plates

The development of analytical procedures for identifying the chemical composition of residue from impacts that occurred on the Interplanetary Dust Experiment (IDE) detectors during the flight of Long Duration Exposure Facility (LDEF) and the carrying out of actual analysis on IDE detectors and other witness plates are discussed. Two papers on the following topics are presented: (1) experimental analysis of hypervelocity microparticle impact sites on IDE sensor surfaces; and (2) contaminant interfaces with secondary Ion Mass Spectrometer (SIMS) analysis of microparticle impactor residues on LDEF surfaces.

Griffis, D. P.↗

Ambulation Increases Decompression Sickness in Spacewalk Simulations

Musculoskeletal activity has the potential to both improve and compromise decompression safety. Exercise enhances inert gas elimination during oxygen breathing prior to decompression (prebreathe), but it may also promote bubble nuclei formation (nucleation), which can lead to gas phase separation and bubble growth and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation may be critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. Data gathered during NASA's Prebreathe Reduction Program (PRP) studies combined oxygen prebreathe and exercise followed by low pressure (4.3 psi; altitude equivalent of 30,300 ft [9,235 m]) microgravity simulation to produce two protocols used by astronauts preparing for extravehicular activity. Both the Phase II/CEVIS (cycle ergometer vibration isolation system) and ISLE (in-suit light exercise) trials eliminated ambulation to more closely simulate the microgravity environment. The CEVIS results (35 male, 10 female) serve as control data for this NASA/Duke study to investigate the influence of ambulation exercise on bubble formation and the subsequent risk of DCS. METHODS Four experiments will replicate the CEVIS exercise-enhanced oxygen prebreathe protocol, each with a different exception. The first of these is currently underway. Experiment 1 - Subjects complete controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining nonambulatory throughout. Experiment 2 - Subjects remain non-ambulatory during the preflight period and ambulatory at 4.3 psi. Experiment 3 - Subjects ambulate during the preflight period and remain non-ambulatory at 4.3 psi. Experiment 4 - The order of heavy and light exercise employed in the CEVIS protocol is reversed, with the light exercise occurring first (subjects remain non-ambulatory throughout). Decompression stress is assessed with non-invasive ultrasound during each of 14 epochs of a 4 hour simulated spacewalk at 4.3 psi; aural Doppler is used to monitor bubbles (Spencer grade 0-IV scale) passing through the pulmonary artery, and two-dimensional echocardiographic imaging is used to look for left ventricular gas emboli (LVGE; the presence of which is a test termination criterion). Venous blood is collected at baseline and twice following repressurization to determine if the decompression stress is correlated with microparticles (cell fragments) accumulation. The plan is to test 25-50 subjects in each experiment. Fisher Exact Tests (one-tailed) are used to compare test and control groups. Trials are suspended when the DCS or grade IV VGE observations reach 70% confidence of DCS risk >15% and grade IV VGE risk >20%. RESULTS Experiment 1 was concluded with 20 complete trials (15 male, 5 female) since the statistical outcome would not change with five additional trials. The observed DCS was significantly greater in Experiment 1 than in CEVIS trials (4/20 [20%] vs. 0/45 [0%], respectively, p=0.007), as was the frequency of peak grade IV VGE (6/21 [29%; including one additional subject that presented grade IV VGE but whose trial was ended before completion when LVGE were observed] vs. 3/45 [7%], respectively, p=0.024). Experiment 3 trials are now underway, with 11 trials completed (10 male, 1 female). Preliminary results indicate no difference in observed DCS between Experiment 3 and CEVIS trials (1/11 [9%] vs. 0/45 [0%], respectively, p=0.196), or between Experiment 3 and Experiment 1 trials (p=0.405). The frequency of peak grade IV VGE in Experiment 3 (2/11 [18%]) did not differ from CEVIS or Experiment 1 trials (p=0.251 and p=0.425, respectively). Microparticle patterns are widely variable and still under analysis. DISCUSSION The results of the Experiment 1 trials support the thesis that decompression stress is increased by ambulation exercise, given the higher incidence of DCS and grade IV VGE when compared to the non-ambulatory PRP CEVIS trials. Experiment 3 trials are incomplete, but suggest that the effect of ambulation during ground level preflight oxygen breathing alone, when subjects are undersaturated with inert gas, may not differ in risk from ambulation at both preflight and spacesuit pressures, the latter when subjects are supersaturated with inert gas. Further trials are needed to confirm the relative effects of ambulation in undersaturated vs. supersaturated states and to determine whether light exercise facilitates the removal of heavy exercise-induced nucleation (Experiment 4).

Pollock, N. W.↗

Particle-Based Microfluidic Device for Providing High Magnetic Field Gradients

A microfluidic device for manipulating particles in a fluid has a device body that defines a main channel therein, in which the main channel has an inlet and an outlet. The device body further defines a particulate diverting channel therein, the particulate diverting channel being in fluid connection with the main channel between the inlet and the outlet of the main channel and having a particulate outlet. The microfluidic device also has a plurality of microparticles arranged proximate or in the main channel between the inlet of the main channel and the fluid connection of the particulate diverting channel to the main channel. The plurality of microparticles each comprises a material in a composition thereof having a magnetic susceptibility suitable to cause concentration of magnetic field lines of an applied magnetic field while in operation. A microfluidic particle-manipulation system has a microfluidic particle-manipulation device and a magnet disposed proximate the microfluidic particle-manipulation device.

Lin, Adam Y.↗

Recent Developments on Autonomous Corrosion Protection Through Encapsulation

This paper concerns recent progress in the development of a multifunctional smart coating, based on microencapsulation, for the autonomous detection and control of corrosion. Microencapsulation has been validated and optimized to incorporate desired corrosion control functionalities, such as early corrosion detection and inhibition, through corrosion-initiated release of corrosion indicators and inhibitors, as well as self-healing agent release triggered by mechanical damage. While proof-of-concept results have been previously reported, more recent research and development efforts have concentrated on improving coating compatibility and synthesis procedure scalability, with a targeted goal of obtaining easily dispersible pigment-grade type microencapsulated materials. The recent progress has resulted in the development of pH-sensitive microparticles as a corrosion-triggered delivery system for corrosion indicators and inhibitors. The synthesis and early corrosion indication results obtained with coating formulations that incorporate these microparticles are reported. The early corrosion indicating results were obtained with color changing and with fluorescent indicators.

Autonomous↗

Submicron immunoglobulin particles exhibit FcγRII-dependent toxicity linked to autophagy in TNFα-stimulated endothelial cells

In intravenous immunoglobulins (IVIG), and some other immunoglobulin products, protein particles have been implicated in adverse events. Role and mechanisms of immunoglobulin particles in vascular adverse effects of blood components and manufactured biologics have not been elucidated. We have developed a model of spherical silica microparticles (SiMPs) of distinct sizes 200–2000 nm coated with different IVIG- or albumin (HSA)-coronas and investigated their effects on cultured human umbilical vein endothelial cells (HUVEC). IVIG products (1–20 mg/mL), bare SiMPs or SiMPs with IVIG-corona, did not display significant toxicity to unstimulated HUVEC. In contrast, in TNFα-stimulated HUVEC, IVIG-SiMPs induced decrease of HUVEC viability compared to HSA-SiMPs, while no toxicity of soluble IVIG was observed. 200 nm IVIG-SiMPs after 24 h treatment further increased ICAM1 (intercellular adhesion molecule 1) and tissue factor surface expression, apoptosis, mammalian target of rapamacin (mTOR)-dependent activation of autophagy, and release of extracellular vesicles, positive for mitophagy markers. Toxic effects of IVIG-SiMPs were most prominent for 200 nm SiMPs and decreased with larger SiMP size. Using blocking antibodies, toxicity of IVIG-SiMPs was found dependent on FcγRII receptor expression on HUVEC, which increased after TNFα-stimulation. Similar results were observed with different IVIG products and research grade IgG preparations. In conclusion, submicron particles with immunoglobulin corona induced size-dependent toxicity in TNFα-stimulated HUVEC via FcγRII receptors, associated with apoptosis and mTOR-dependent activation of autophagy. Testing of IVIG toxicity in endothelial cells prestimulated with proinflammatory cytokines is relevant to clinical conditions. Our results warrant further studies on endothelial toxicity of sub-visible immunoglobulin particles.

59 BASIC BIOLOGICAL SCIENCES↗

Atmospheric clearing of solid-particle debris using femtosecond filaments

Through nonlinear self-focusing, femtosecond pulses can propagate several kilometers beyond diffraction limits, forming an ionization channel in air known as a laser filaments. It has been demonstrated that in the wake of the filament, aerosols can be effectively cleared to improve the transmission of subsequent laser pulses or secondary light sources, pertinent to applications in atmospheric sensing. However, the current understanding of aerosol clearing is founded on interactions with droplets to simulate fogs and clouds and thus does not extend to solid particles or atmospheric debris. Using optical trapping, we isolate both graphite and silica microparticles and directly measure the subsequent displacement caused by the filament using time-resolved shadowgraphy. The shock wave from the filament is demonstrated to propel particles away from the filament, directly contributing to atmospheric debris clearing. Particles exposed to the laser light in either the intense filament core or the surrounding energy reservoir are axially displaced along the beam path. Furthermore, it is found that the optomechanical properties of the particle largely influence the axial displacement induced by laser exposure through mechanisms such as radiation pressure, mass ejection from ablation or optical damage, and particle deagglomeration.

42 ENGINEERING↗

Wireless Frequency‐Multiplexed Acoustic Array‐Based Acoustofluidics

Abstract Acoustofluidics has shown great potential in enabling on‐chip technologies for driving liquid flows and manipulating particles and cells for engineering, chemical, and biomedical applications. To introduce on‐demand liquid sample processing and micro/nano‐object manipulation functions to wearable and embeddable electronics, wireless acoustofluidic chips are highly desired. This paper presents wireless acoustofluidic chips to generate acoustic waves carrying sufficient energy and achieve key acoustofluidic functions, including arranging particles and cells, generating fluid streaming, and enriching in‐droplet particles. To enable these functions, the wireless acoustofluidic chips leverage mechanisms, including inductive coupling‐based wireless power transfer (WPT), frequency multiplexing‐based control of multiple acoustic waves, and the resultant acoustic radiation and drag forces. For validation, the wirelessly generated acoustic waves are measured using laser vibrometry when different materials (e.g., bone, tissue, and hand) are inserted between the WPT transmitter and receiver. Moreover, the wireless acoustofluidic chips successfully arrange nanoparticles into different patterns, align cells into parallel pearl chains, generate streaming, and enrich in‐droplet microparticles. This research is anticipated to facilitate the development of embeddable wireless on‐chip flow generators, wearable sensors with liquid sample processing functions, and implantable devices with flow generation and acoustic stimulation abilities for engineering, veterinary, and biomedical applications.

Li, Jiali↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards a quantitative understanding of bonding in supersonic single particle impacts: A three-dimensional FIB-SEM exploration

Particle bonding is crucial to coating quality in cold spray, but it has been a challenge to accurately quantify bonding even in single particle impacts. This paper uses FIB-SEM to explicitly map the particle-substrate interface for Cu-on-Cu single microparticle impacts in a full 3D rendering that spans a wide range of impact velocities. This approach permits a detailed quantification of the total bonding area and all of its associated components. In addition to revealing why prior 2D characterization efforts have missed important details about impact bonding, these data quantitatively reveal the evolution of bonding from its onset at the “critical velocity” V cr (where bonding is generally poor, ∼6 %) to its peak at around 1.3‧V cr (where almost 90 % of the particle bonds). Further increase in the velocity to 1.5‧V cr and beyond finds the onset of hydrodynamic penetration and a decrease in bonding. These data then support the development of a simple analytical model based on oxide rarefication and extrusion of bare metal through gaps in the oxide layer as driving the development of bonding. As a result, the model reproduces the experiments and provides guidance on optimization of bonding as a function of material and process parameters.

Analytical methods↗

Tunable structure and reinforcement of polyvinyl alcohol (PVA) hydrogels using fungal chitin particles

Polysaccharides, including chitin, are one of the most abundant biopolymers in nature and are increasingly recognized as a sustainable alternative to petroleum-derived plastics and synthetic fillers in polymer composites. Traditionally sourced from crustacean shells, chitin offers mechanical strength and biocompatibility with limitations also in processability and functionality. Fungal-derived chitin material represents a promising alternative, with advantages including scalable fermentation on low-cost substrates, absence of shellfish allergens, and tunable molecular architectures that vary by species, developmental stage, and growth environment. Here, in this study, we systematically examined chitinous materials obtained from taxonomically and functionally distinct fungi, Laccaria bicolor, Trichoderma reesei and Rhizopus oryzae, to assess their structural, chemical, and morphological properties as reinforcement agents in polymer composites. Mild alkaline pretreatment was employed to obtain mycelium chitin particles, thereby improving accessibility to chitin and co-occurring β-D-glucans while maintaining microparticle integrity. Comprehensive FTIR and solid-state NMR analyses revealed species-specific differences in chemical composition and microstructure, with R. oryzae exhibiting a unique spectral signature. These fungal-derived chitin were then incorporated into poly(vinyl alcohol) (PVA) hydrogels, where they acted as reinforcing fillers without the need for additional chemical crosslinkers. Comparative evaluation of hydrogel properties demonstrated that fungal chitin significantly enhanced mechanical performance, with all mycelium fillers mitigating the water weakening in PVA hydrogels. R. oryzae-derived composites tripled the hydrogel tensile strength while the submicron fibrous morphology in L. bicolor contributes to over 45 % tensile improvement in dry PVA composites. Our findings highlight the potential of fungal biomass as a tunable, sustainable platform for producing chitin-based reinforcing agents.

Chitin↗

Reconfigurable self-assembly of porous anisotropic colloids in nematic liquid crystals

Dispersions of anisotropic nanoparticles in liquid crystalline hosts recently yielded new soft condensed matter states, like the thermally reconfigurable monoclinic and orthorhombic biaxial nematic liquid crystals, with a plethora of unusual phases and phase transformations. Our current study shows that the nanoscale porous nature of colloids with micrometer-range overall dimensions also enables highly reconfigurable orientations and assemblies of the microparticles, allowing for realization of condensed matter states with unusual combinations of low-symmetry nematic or smectic order and fluidity. Much like the anisotropic nanoparticles studied previously, these nanoporous anisotropic colloids exhibit thermally reconfigurable oriented alignment with respect to the far-field director, as well as diverse low-symmetry liquid crystalline phase behaviors. Furthermore, our findings open doors to fundamental and applied uses of low-symmetry molecular-colloidal orientationally ordered states of matter with uninhibited fluidity, as well as liquid crystals with partial positional ordering, like low-symmetry smectics, which could lead to applications in metamaterial designs, electro-optics, photonics, etc.

colloidal dispersion↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Flow-through Cell for Ultrasonic Extraction (UE)─Single Particle (SP)─ICP-MS─an Approach for Nano/Microparticle Elemental and Isotopic Analysis

Nanotechnology is a salient part of the scientific landscape, and analytical approaches are rapidly evolving to enable small-scale characterization of nano- and microparticle compositions and impurities. Here, a flow-through sonicating cell was developed for direct particle extraction from a silicon wafer and integrated with an inductively coupled plasma–mass spectrometer (ICP-MS) for subsequent elemental and isotopic characterization of the released particles. Ultrasonic extraction (UE)─single particle (SP)─ICP-MS offers controlled particle mobilization from solid substrates and allows for increased sample throughput by eliminating the need for pre-extraction of particles and decreasing sample preparation steps. Coupling this device to an ICP-MS with a time-of-flight (TOF) mass analyzer, it is possible to distinguish unique isotopic compositions of the particles. Both tungsten and nickel isotopically tagged particles, which were deposited on Si wafers, are presented here with analysis via UE─SP─ICP-MS. This approach could support efforts in the fields of particle synthesis, nuclear safeguards and forensics, environmental monitoring, and semiconductor industries in which the detection of particles from substrates and wafers is critical.

Paul, Molly [ORNL] (ORCID:0009000009672055)↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗

Mid-Infrared Photoluminescence from Tellurium Thin Films

Tellurium is an elemental semiconductor with a 0.34 eV optical band gap, showing promise for mid-infrared (MIR) optoelectronics including light-emitting diodes. However, quantitative measurement of the tellurium luminescence efficiency has not yet been investigated, and growing optically active films remain challenging. Here, we demonstrate the low-temperature growth of bright tellurium thin films by using physical vapor transport. The sample morphology is controlled by varying the growth temperature, yielding continuous thin films, microparticles, or nanowires. Additionally, we demonstrated patterned growth by using a seed layer for selective nucleation. Quantitative photoluminescence measurements at room temperature reveal an internal quantum yield of 2.0% at 0.34 eV for the as-grown tellurium films, comparable to the best-reported efficiencies of III-V and II-VI compound semiconductors with similar band gaps. Furthermore, we demonstrate band-gap tunability with Te-Se alloys, where up to 20% selenium incorporation gradually blue-shifts the band gap to 0.55 eV. The work demonstrates the potential use of tellurium for efficient MIR devices.

Wang, Shu↗