A self-adjustable four-point probing system using polymeric three dimensional coils and non-toxic liquid metal

This paper describes a self-adjustable four-point probe (S4PP) system with a square configuration. The S4PP system consists of 3D polymer coil springs for the independent operation of each tungsten (W) probe, microfluidic channels filled with a nontoxic liquid metal, and a LabView-based control system. The 3D coil springs made by PMMA are fabricated with a 3D printer and are positioned in a small container filled with the non-toxic liquid metal. This unique configuration allows independent self-adjustment of the probe heights for precise measurements of the electrical properties of both flexible and large-step-height microsamples. The feasibility of the fabricated S4PP system is evaluated by measuring the specific resistance of Cr and Au thin films deposited on silicon wafers. The system is then employed to evaluate the electrical properties of a Au thin film deposited onto a flexible and easily breakable silicon diaphragm (spring constant: ∼3.6 × 10{sup −5} N/m). The resistance of the Cr thin films (thickness: 450 nm) with step heights of 60 and 90 μm is also successfully characterized. These experimental results indicate that the proposed S4PP system can be applied to common metals and semiconductors as well as flexible and large-step-height samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Digital laser frequency auto-locking for inter-satellite laser ranging

We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Design and implementation of a home-built imaging system with low jitter for cold atom experiments

A novel home-built system for imaging cold atom samples is presented using a readily available astronomy camera which has the requisite sensitivity but no timing-control. We integrate the camera with LabVIEW achieving fast, low-jitter imaging with a convenient user-defined interface. We show that our system takes precisely timed millisecond exposures and offers significant improvements in terms of system jitter and readout time over previously reported home-built systems. Our system rivals current commercial “black box” systems in performance and user-friendliness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of wireless dose logger network for radiological emergency decision support system

A decision support system (DSS) is implemented in Radiological Safety Division, Indira Gandhi Centre for Atomic Research for providing guidance for emergency decision making in case of an inadvertent nuclear accident. Real time gamma dose rate measurement around the stack is used for estimating the radioactive release rate (source term) by using inverse calculation. Wireless gamma dose logging network is designed, implemented, and installed around the Madras Atomic Power Station reactor stack to continuously acquire the environmental gamma dose rate and the details are presented in the paper. The network uses XBee–Pro wireless modules and PSoC controller for wireless interfacing, and the data are logged at the base station. A LabView based program is developed to receive the data, display it on the Google Map, plot the data over the time scale, and register the data in a file to share with DSS software. The DSS at the base station evaluates the real time source term to assess radiation impact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Spectral Analysis Program

Advanced Spectral Analysis Program is a LabVIEW-based program intended for rapid and accurate analysis of large sets of spectral data. It can handle a range of different types of data including angle-resolved and energy-dispersive powder diffraction and Raman spectra. We present it here with a focus on high-temperature high-pressure powder diffraction. The program contains a novel graphical user interface that allows rapid manual fitting and indexing of peaks which require precise fitting ranges and includes tools for fitting any Bravais lattice and arbitrary user-defined multivariate equations of state. The program allows the user to simultaneously view and manipulate multiple data sets from an experiment. The user can save and load analysis progress at any point, allowing for repeatable calculations to be performed, and to allow the fast comparison of different analysis parameters.

47 OTHER INSTRUMENTATION↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

Versatile semi-batch apparatus for manometric measurement of gas–solid reaction rates

In this study, we describe the design, construction, operation, and performance of a simple and versatile semi-batch reactor that is especially useful for measurement of gas/solid reaction rates at pressures in the range of 1 mTorr to 1500 Torr. The reactor operates by repeatedly imposing small AC modulations of reactant gas pressure on top of a much larger DC pressure background. Based on the rate of pressure relaxation following each AC pulse, the reaction rate is determined. Our design is characterized by modular construction from off-the-shelf, ultra-high-vacuum-compatible components, which facilitate easy retrofitting and adaptation to a range of experimental conditions. Automated experiment control and data acquisition is accomplished via a custom National Instruments © LabView virtual instrument. Data analysis is automated using a custom series of Mathworks © Matlab scripts. We demonstrate reactor performance through measurements of hydrogenation kinetics for a composite H 2 getter material consisting of 1,4-bis(phenylethynyl)benzene mixed with a palladium/carbon catalyst.

47 OTHER INSTRUMENTATION↗

Characterization of a new ultra-high pressure shock tube facility for combustion and propulsion studies

A new shock tube facility has been designed, constructed, and characterized at the University of Central Florida. This facility is capable of withstanding pressures of up to 1000 atm, allowing for combustion diagnostics of extreme conditions, such as in rocket combustion chambers or in novel power conversion cycles. For studies with toxic gas impurities, the high initial pressures required the development of a gas delivery system to ensure the longevity of the facility and the safety of the personnel. Data acquisition and experimental propagation were implemented with remote access to ensure safety, paired with a LabVIEW- and Python-based user interface. Thus far, test pressures of 270 atm, blast pressures of 730 atm, and temperatures approaching 10 000 K have been achieved. The extreme limitations of this facility allow for emission spectroscopy to be performed during the oxidation of fuel mixtures, e.g., alkanes diluted in argon and carbon dioxide. Ignition delay times were determined and compared to simulations using chemical kinetic mechanisms. The design, experimental procedures, processes of analysis, and uncertainty determination are outlined, and typical pressure profiles are compared with a new gas dynamics solver and empirical correlations developed across multiple shock tube facilities. Preliminary reactive mixture analyses are included with further investigation of the mixtures outlined.

47 OTHER INSTRUMENTATION↗

An automatic multi-precursor flow-type atomic layer deposition system

Designs for two automated atomic layer deposition (ALD) flow reactors are presented, and their capabilities for coating additively manufactured (AM) metal prints are described. One instrument allows the coating of several AM parts in batches, while the other is useful for single part experiments. To demonstrate reactor capabilities, alumina (Al 2 O 3 ) was deposited onto AM 316L stainless steel by dosing with water (H 2 O) vapor and trimethylaluminum (TMA) and purging with nitrogen gas (N 2 ). Both instruments are controlled by custom-programmed LabVIEW software that enables in situ logging of temperature, total pressure, and film thickness using a quartz crystal microbalance. An initial result shows that 150 ALD cycles led to a film thickness of ~55 nm, which was verified with Rutherford backscattering spectroscopy. This indicates that the reactors were indeed depositing single atomic layers of Al 2 O 3 per ALD cycle, as intended.

47 OTHER INSTRUMENTATION↗

Low cost switching circuit for van der Pauw resistivity and Hall measurements at various temperatures

The electrical characterization of materials, particularly superconductors, semiconductors, and those undergoing metal-insulator transitions (MITs), relies significantly on resistivity and Hall measurements as a function of temperature. The van der Pauw four-point probe method is commonly used for such measurements, which involves resistance measurements for different circuit configurations connected to sample contacts. However, repeating these measurements at different temperatures is challenging and time consuming. Here, this study introduces a novel approach utilizing a switching circuit controlled by an Arduino device and a LabVIEW program to automate resistance measurements for different electrical configurations. The effectiveness of this setup was demonstrated by testing V 2 O 3 thin film samples deposited on Al 2 O 3 (001) substrates using DC magnetron sputtering. The MIT temperature of the sample was 115 K during heating and 100 K during cooling. The sample exhibited p-type charge carriers with a Hall coefficient of 1.3 ± 0.1 x 10 -4 cm 3 /C and Hall mobility of 1.7 x 10 -1 cm 2 /V∙s, which is consistent with findings from other studies employing commercial equipment.

36 MATERIALS SCIENCE↗

Fabrication, Assembly, and Metrology of the Neutron Imaging Pinhole

The neutron imaging pinhole is a complex aperture that is designed to have its image plane at the center of a laser fusion capsule implosion. The aperture’s high-Z materials of tungsten and gold block the neutrons so that only the neutrons passing through the machined apertures make it to the image plane and detector. The pinhole assembly consists of 11 layers of gold in between two layers of tungsten and gold. These 64 triangular pinholes and six penumbra apertures provide a matrix image that can be reconstructed to image complex deuterium-tritium neutron burn details in laser fusion capsules. The gold layers were diamond turned flat before the profiles were cut into their faces. Four of the layers were profiled with penumbral profile arrays that tapered from a radius of 250 to 150 µm. Three gold layers were just diamond turned to wedges to set the tilt of the whole aperture. Three gold layers were profiled on both sides with triangle groove arrays that consist of eight equilateral triangles with the depth of 200 to 15 µm over the 200-mm length, with a tolerance of 2 µm. Custom software programming routines were written using Labview to move the diamond-turning profiler through the required X-Y-Z movements to cut the penumbral and grooved profiles of the pinhole into the varying tilted arrays of features. The software is optimized to push the profile of the whole part into the face while eliminating any unneeded passes that do not cut any material. Each layer was thoroughly inspected on both sides using an optical coordinate measuring machine and white-light interferometer to validate each of the profiles. The pinhole assembly was inspected on a rotary stage so that both ends of the assembly can be inspected and presented in a single point cloud. The process of machining, programming, assembly, and inspection of the neutron imaging pinhole is covered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated X-Ray Tomographic Defect Analysis in High Density Carbon Capsules

High density carbon capsule ablators are of primary interest for National Ignition Facility experiments. Two of the major contributors to hydrodynamic instabilities in these capsules are voids and high-density inclusions, where the quantity and size of these defects can result in lower yields in inertial confinement fusion. To aid in capsule selection, General Atomics developed a LabVIEW analysis routine to quantify these defects based off a large field of view tomographic dataset and provide insight into the quality of the capsule. Furthermore, this analysis determines if there are large voids or inclusions that may affect shot performance and helps rank which capsules should be used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inter-strand current sharing and ac loss measurements in superconducting YBCO Roebel cables

A Roebel cable, one twist pitch long, was modified from its as-received state by soldering copper strips between the strands to provide inter-strand connections enabling current sharing. Various DC transport currents (representing different percentages of its critical current) were applied to a single strand of such a modified cable at 77 K in a liquid nitrogen bath. Simultaneous monitoring of I–V curves in different parts of the strand as well as in its interconnections with other strands was made using a number of sensitive Keithley nanovoltmeters in combination with a multichannel high-speed data acquisition card, all controlled via LabView software. Current sharing onset was observed at about 1.02 of strand I c . At a strand current of 1.3I c about 5% of the current was shared through the copper strip interconnections. A finite element method modeling was performed to estimate the inter-strand resistivities required to enable different levels of current sharing. The relative contributions of coupling and hysteretic magnetization (and loss) were compared, and for our cable and tape geometry, and at dB/dt=1 T s -1 , and our inter-strand resistance of 0.77 mΩ, (enabling a current sharing of 5% at 1.3I c ) the coupling component was 0.32% of the hysteretic component. However, inter-strand contact resistance values of 100–1000 times smaller (close to those of NbTi and Nb 3 Sn based accelerator cables) would make the coupling components comparable in size to the hysteretic components.

36 MATERIALS SCIENCE↗

Inter-strand current sharing and ac loss measurements in superconducting YBCO Roebel cables

A Roebel cable, one twist pitch long, was modified from its as-received state by soldering copper strips between the strands to provide inter-strand connections enabling current sharing. Various DC transport currents (representing different percentages of its critical current) were applied to a single strand of such a modified cable at 77 K in a liquid nitrogen bath. Simultaneous monitoring of I–V curves in different parts of the strand as well as in its interconnections with other strands was made using a number of sensitive Keithley nanovoltmeters in combination with a multichannel high-speed data acquisition card, all controlled via LabView software. Current sharing onset was observed at about 1.02 of strand I c . At a strand current of 1.3I c about 5% of the current was shared through the copper strip interconnections. A finite element method modeling was performed to estimate the inter-strand resistivities required to enable different levels of current sharing. The relative contributions of coupling and hysteretic magnetization (and loss) were compared, and for our cable and tape geometry, and at dB/dt=1 T s -1 , and our inter-strand resistance of 0.77 mΩ, (enabling a current sharing of 5% at 1.3I c ) the coupling component was 0.32% of the hysteretic component. However, inter-strand contact resistance values of 100–1000 times smaller (close to those of NbTi and Nb 3 Sn based accelerator cables) would make the coupling components comparable in size to the hysteretic components.

36 MATERIALS SCIENCE↗

The CUORE slow monitoring systems

CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in $^{130}$Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EPICS for small-scale laboratories with Python soft IOCs

While the Experimental Physics and Industrial Control System (EPICS) is widely used at large laboratories for slow controls and instrumentation, the deployment of a full EPICS installation can be difficult, with a steep learning curve to new users. Taking advantage of the pythonSoftIOC module, we developed an EPICS slow controls implementation for Jefferson Lab's Hall B cryotarget written entirely in Python and based on software IOCs that communicate with instruments over Ethernet. Here, this system ran successfully, interfacing with Jefferson Lab's full EPICS network, and we offer it as an example of the capabilities of pythonSoftIOC to build lightweight, yet robust and flexible instrumentation platforms that would be easily adapted for use at a small-scale laboratory. University groups can use these examples to build complete slow controls systems, from device communication to data archiving and display, using open-source, mature EPICS tools and student-friendly Python as an alternative to expensive and proprietary systems such as LabVIEW.

Computing↗

Longitudinal bunch monitoring at the Fermilab Tevatron and Main Injector synchrotrons

The measurement of the longitudinal behavior of the accelerated particle beams at Fermilab is crucial to the optimization and control of the beam and the maximizing of the integrated luminosity for the particle physics experiments. Longitudinal measurements in the Tevatron and Main Injector synchrotrons are based on the analysis of signals from resistive wall current monitors. This study describes the signal processing performed by a 2 GHz-bandwidth oscilloscope together with a computer running a LabVIEW program which calculates the longitudinal beam parameters.

43 PARTICLE ACCELERATORS↗

Instrument Front-Ends at Fermilab During Run II

The optimization of an accelerator relies on the ability to monitor the behavior of the beam in an intelligent and timely fashion. The use of processor-driven front-ends allowed for the deployment of smart systems in the field for improved data collection and analysis during Run II. This paper describes the implementation of the two main systems used: National Instruments LabVIEW running on PCs, and WindRiver's VxWorks real-time operating system running in a VME crate processor.

43 PARTICLE ACCELERATORS↗