Hydrogen diffusion induced dislocation transformations in a nickel superalloy

The diffusion of hydrogen in metals and alloys induces embrittlement that can adversely affect the structural properties. We examine the adsorption and diffusion of hydrogen in Inconel-718 (IN-718), and scrutinize the ensuing effects on the dislocation behavior in the alloy to elucidate the fundamental mechanisms of hydrogen-microstructure interactions from classical molecular simulations. Hydrogen adsorption increases with time until the surface saturates, while hydrogen diffusion exhibits strong temperature dependence, with diffusion coefficients converging above 1300 K regardless of the initial hydrogen concentration in the alloy. The diffusion in IN-718 is significantly sluggish than in pure Ni, Fe, or Cr, and is strongly impacted by hydrogen concentrations, resulting in an order of magnitude higher diffusion coefficient for hydrogen (10-14 m2/s relative to 10-15 m2/s) at high concentrations, especially below 600 K. Hydrogen diffusion coefficient varies from 10-12 to 10-15 m2/s in IN-718 depending on temperature (500–1400 K). More critically, our results reveal that increasing hydrogen concentration induces microstructural changes in the alloy, transforming perfect dislocations into stair-rods and Shockley partials, with higher temperatures favoring the latter. The results are significant for hydrogen fuel applications to gain insights into the materials chemistry for designing safer and more efficient propulsion systems, particularly in high-performance environments related to controlled hydrogen combustion applications.

Banerjee, Tanumoy↗

Production and Characterization of Additively Manufactured Radiator Panels with Integral Branching Heat Pipes for High-Temperature Heat Rejection

Emerging concepts for fission surface power and nuclear electric propulsion necessitate lightweight, mechanically robust, and thermally efficient heat rejection radiators. State-of-the-art intermediate-temperature (~400 K) composite radiator assemblies have been developed based on titanium-water heat pipes bonded to metal, graphite, and carbon-fiber-based panels. NASA has identified a need for new radiator concepts that can operate at even higher temperatures (500 – 600 K), minimize thermal resistances and thermal stress failures at bond interfaces, and approach areal densities of 2 – 3 kg m -2 . To meet these needs, our team is developing additively manufactured (AM) radiator panels with integral branching wicking heat pipe networks. Water is selected as the working fluid for this temperature range. Based on simulations and thermal vacuum experiments, these branching embedded heat pipe networks can efficiently distribute heat over panels for finned surface efficiencies of η f >70% at T H = 500 K input heat. This paper first presents laser powder-bed fusion AM strategies to produce embedded porous structures for wicking heat pipes in Inconel 718 and titanium alloys (commercially pure and Ti-6Al-4V alloys). Post-build chemical and thermal treatments are described that yield hydrophilic wicking surfaces for operation with water. Transient rate-of-rise experiments with water and acetone are reported that yield estimates for AM wick porosity (ϵ), permeability (K), and effective pore radius (r pore ). Based on the wick characterization results, small prototype radiator panels (75 × 125 mm) with integrated heat pipe networks were manufactured. Heat rejection performance data are presented from cold thermal vacuum testing, with heat input temperatures up to ~510 K. Future efforts will focus on improving heat pipe performance, optimizing radiator mass, and evaluating larger panels to assess scalability.

thermal management↗

Production and Characterization of Additively Manufactured Radiator Panels With Integral Branching Heat Pipes for High-Temperature Heat Rejection

Emerging concepts for fission surface power and nuclear electric propulsion necessitate lightweight, mechanically robust, and thermally efficient heat rejection radiators. State-of-the-art intermediate-temperature (~400 K) composite radiator assemblies have been developed based on titanium-water heat pipes bonded to metal, graphite, and carbon-fiber-based panels. NASA has identified a need for new radiator concepts that can operate at even higher temperatures (500 – 600 K), minimize thermal resistances and thermal stress failures at bond interfaces, and approach areal densities of 2 – 3 kg m -2 . To meet these needs, our team is developing additively manufactured (AM) radiator panels with integral branching wicking heat pipe networks. Water is selected as the working fluid for this temperature range. Based on simulations and thermal vacuum experiments, these branching embedded heat pipe networks can efficiently distribute heat over panels for finned surface efficiencies of η f >70% at T H = 500 K input heat. This paper first presents laser powder-bed fusion AM strategies to produce embedded porous structures for wicking heat pipes in Inconel 718 and titanium alloys (commercially pure and Ti-6Al-4V alloys). Post-build chemical and thermal treatments are described that yield hydrophilic wicking surfaces for operation with water. Transient rate-of-rise experiments with water and acetone are reported that yield estimates for AM wick porosity (ϵ), permeability (K), and effective pore radius ( r pore ). Based on the wick characterization results, small prototype radiator panels (75 × 125 mm) with integrated heat pipe networks were manufactured. Heat rejection performance data are presented from cold thermal vacuum testing, with heat input temperatures up to ~510 K. Future efforts will focus on improving heat pipe performance, optimizing radiator mass, and evaluating larger panels to assess scalability.

nuclear electric propulsion↗

In Situ High-Temperature TEM Observation of Inconel Corrosion by Molten Chloride Salts with N 2 , O 2 , or H 2 O

Here, in situ transmission electron microscopy (TEM) diffraction and imaging techniques are used to monitor and quantify corrosion of Inconel-625 by pure molten chloride salts (MgCl 2 – NaCl – KCl) at 500 °C–800 °C in 1.0 atm inert N 2 or pure O2, or by salts which are controllably hydrated in a high vacuum chamber. The isothermal corrosion rate R in inert N 2 increases from 203 ± 30 μ m year –1 at 700 °C to 463 ± 30 μ m year –1 at 800 °C. An oxygen ambient causes a six-fold increase to R = 1261 ± 170 μ m year –1 at 700 °C. Salt hydration dramatically accelerates corrosion to R > 3 × 10 5 μ m year –1 at 700 °C while it leads to a more moderate R = 95 ± 20 and 486 ± 30 μ m year –1 at 500 °C and 600 °C, respectively. These isothermal corrosion rates indicate that the molten chloride corrosion is significantly accelerated by salt hydration at temperatures above 600 °C, where corrosion is aggravated by increased generation and solubility of corrosive HCl gases. Hence, to reduce rate of corrosion it is important to both avoid incorporation of H 2 O into the system at each stage and ensure proper flushing of the system before increasing the temperature beyond 600 °C. Compositional analysis of the corroded cells indicate that corrosion in O 2 ambient is dominated by oxidation of metals by O 2 gas dissolved in the chloride melt, but corrosion in H 2 O ambients is caused by chlorination of metals by dissolved HCl gas and MgOH + ions. So, to reduce rate of corrosion, steps should be taken to tailor chloride melt compositions that has low solubility for HCl and O 2 . All of our corroded samples exhibit passive-protective oxide layers of Cr, Mg, and Ni. In addition, distinct volatile compounds of Ni, Mo and Cr involving NiCl 2 , (Na,K) 2 MoO 4 and CrO 2 (OH) 2 are detected in N 2 , H 2 O, and O 2 ambients, respectively. We believe that corrosion acceleration can be minimized by minimizing formation of volatile by-products or promoting reactions that could convert these volatile compounds to solid phases, as these volatile compounds led to destruction of protective oxide layers.

14 SOLAR ENERGY↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Corrosion of alloys in a chloride molten salt (NaCl-LiCl) for solar thermal technologies

Next-generation solar power conversion systems in concentrating solar power (CSP) applications require high-temperature advanced fluids in the range of 600–800 °C. Current commercial CSP plants use molten nitrate salt mixtures as the heat transfer fluid and the thermal energy storage (TES) media while operating with multiple hours of energy capacity and at temperatures lower than 565 °C. At higher temperatures, the nitrates cannot be used because they decompose. Molten chloride salts are candidates for CSP applications because of their high decomposition temperatures and good thermal properties; but they can be corrosive to common alloys used in vessels, heat exchangers, and piping at these elevated temperatures. In this article, we present the results of the corrosion evaluations of several alloys in eutectic 34.42 wt% NaCl – 65.58 wt% LiCl at 650–700 °C in nitrogen atmosphere. Electrochemical evaluations were performed using open-circuit potential followed by a potentiodynamic polarization sweep. Corrosion rates were determined using Tafel slopes and Faraday's law. A temperature increase of as little as 50 °C more than doubled the corrosion rate of AISI stainless steel 310 and Incoloy 800H compared to the initial 650 °C test. These alloys exhibited localized corrosion. Inconel 625 was the most corrosion-resistant alloy with a corrosion rate of 2.80±0.38 mm/year. For TES applications, corrosion rates with magnitudes of a few millimeters per year are not acceptable because of economic considerations. Additionally, localized corrosion (intergranular or pitting) can be catastrophic. Furthermore, corrosion-mitigation approaches are required for advanced CSP plants to be commercially viable.

47 OTHER INSTRUMENTATION↗

CHARACTERIZATION OF ELEVATED TEMPERATURE PROPERTIES OF HEAT EXCHANGER AND STEAM GENERATOR ALLOYS

The Next Generation Nuclear Plant project is considering Alloy 800H and Alloy 617 for steam generator and intermediate heat exchangers. It is envisioned that a steam generator would operate with reactor outlet temperatures from 750 to 800 C, while an intermediate heat exchanger for primary to secondary helium would operate up to an outlet temperature of 950 C. Although both alloys are of interest due in part to their technical maturity, a number of specific properties require further characterization for design of nuclear components. Strain rate sensitivity of both alloys has been characterized and is found to be significant above 600 C. Both alloys also exhibit dynamic strain aging, characterized by serrated flow, over a wide range of temperatures and strain rates. High temperature tensile testing of Alloy 617 has been conducted over a range of temperatures. Dynamic strain aging is a concern for these materials since it is observed to result in reduced ductility for many solid solution alloys. Creep, fatigue, and creep-fatigue properties of Alloy 617 have been measured as well, with the goal of determining the influence of the temperature, strain rate and atmosphere on the creep fatigue life of Alloy 617. Elevated temperature properties and implications for codification of the alloys will be described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The stress corrosion cracking behavior of alloys 690 and 152 WELD in a PWR environment.

Alloys 690 and 152 are the replacement materials of choice for Alloys 600 and 182, respectively. The latter two alloys are used as structural materials in pressurized water reactors (PWRs) and have been found to undergo stress corrosion cracking (SCC). The objective of this work is to determine the crack growth rates (CGRs) in a simulated PWR water environment for the replacement alloys. The study involved Alloy 690 cold-rolled by 26% and a laboratory-prepared Alloy 152 double-J weld in the as-welded condition. The experimental approach involved pre-cracking in a primary water environment and monitoring the cyclic CGRs to determine the optimum conditions for transitioning from the fatigue transgranular to intergranular SCC fracture mode. The cyclic CGRs of cold-rolled Alloy 690 showed significant environmental enhancement, while those for Alloy 152 were minimal. Both materials exhibited SCC of 10{sup -11} m/s under constant loading at moderate stress intensity factors. The paper also presents tensile property data for Alloy 690TT and Alloy 152 weld in the temperature range 25--870 C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermochemical Heat Storage for Concentrated Solar Power: Thermochemical System Reactor Design for Thermal Energy Storage

Thermal energy storage (TES) is an integral part of a concentrated solar power (CSP) system. It enables plant operator to generate electricity beyond on sun hours and supply power to the grid to meet peak demand. Current CSP sensible heat storage systems employ molten salts as both the heat transfer fluid and the heat storage media. These systems have an upper operating tempera ture limit of around 400°C. Future TES systems are expected to operate at temperatures between 600°C–1000°C for higher thermal efficiencies which should result in lower electricity cost. To meet future operating temperature and electricity cost requirements, a TES concept utilizing thermochemical cycles (TCs) based on multivalent solid oxides was proposed. The system employs a pair of reduction and oxidation (REDOX) reactions to store and release heat. In the storage step, hot air from the solar receiver is used to reduce the oxidation state of an oxide cation, e.g. Fe 3+ to Fe 2+ . Heat energy is thus stored as chemical bonds and the oxide is “charged”. To discharge the stored energy, the reduced oxide is re-oxidized in air and heat is released. Air is used as both the heat transfer fluid and reactant and no storage of fluid is needed. This project investigated the engineering and economic feasibility of this proposed TES concept. The DOE storage cost and LCOE targets are $\$$15/kWh and $\$$0.09/kWh respectively. Sixteen pure oxides cycles were identified through thermodynamics calculations and literature information. Data showed the kinetics of re-oxidation of the various oxides to be a key barrier to implementing the proposed concept. A down selection was carried out based on operating temperature, materials costs and preliminary laboratory measurements. Cobalt oxide, manganese oxide and barium oxide were selected for developmental studies to improve their REDOX reaction kinetics. A novel approach utilizing mixed oxides to improve the REDOX kinetics of the selected oxides was proposed. It partially replaces some of the primary oxide cations with selected secondary cations. This causes a lattice charge imbalance and increases the anion vacancy density. Such vacancies enhance the ionic mass transport and lead to faster re-oxidation. Re oxidation fraction of Mn 3 O 4 → Mn 2 O 3 and CoO → Co 3 O 4 was improved by up to 16 fold through the addition of a secondary oxide. However, no improvement was obtained in barium based mixed oxides. In addition to enhancing the short term re-oxidation kinetics, it was found that the use of mixed oxides also help to stabilize or even improve the TES properties after long term thermal cycling. Part of this improvement could be attributed to a reduced grain size in the mixed oxides. Based on the measurement results, manganese-iron, cobalt-aluminum and cobalt iron mixed oxides have been proposed for future engineering scale demonstration. Using the cobalt and manganese mixed oxides, we were able to demonstrate charge and discharge of the TES media in both a bench top fixed bed and a rotary kiln-moving bed reactor.

14 SOLAR ENERGY↗