Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Guest Editorial: Special issue on flexible and resilient urban energy systems

This guest editorial summarizes the topics and the papers selected for the Special Issue on Flexible and Resilient Urban Energy Systems. After rigorous reviewing process, 21 papers are accepted for publication. These 21 accepted papers cover various aspects of urban energy systems and are distributed as following: situational awareness of urban energy systems (2 papers), quantification metrics of flexibility and resilience of urban energy systems (3 papers), vulnerability modeling of urban energy systems under various extreme events (3 papers), planning of flexible and resilient urban energy systems (4 papers), robust and resilient operation and control of urban energy systems (4 papers), recovery and restoration strategy of urban energy systems (2 papers), and coordination and interoperability of interconnected energy systems (3 papers). The Guest Editorial Board hopes this Special Issue can provide a valuable information for future research and advancements in the field of flexible and resilient urban energy systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Norms for Civilian Nuclear Power Plants

The international community agrees that the safe operation of civilian nuclear infrastructure is in every population’s best interest. One challenge each government must address is defining and agreeing to a set of acceptable norms of behavior in cyberspace as they relate to these facilities. The introduction of digital systems and networking technologies into these environments has led to the possibility that control and supporting computer systems are now accessible and exploitable, especially where interconnections to global information and communications technology (ICT) networks exist. The need for norms of behavior in cyberspace includes what is expected of system architects and cyber defenders as well as adversaries who should abide by rules of engagement even while conducting acts that violate national and international laws. The goal of this paper is to offer three behavioral cyber norms to improve the overall security of the ICT and Operational Technology (OT) networks and systems that underlie the operations of nuclear facilities. These norms of behavior will be specifically defined with the goals of reducing the threats associated to the theft of nuclear materials, accidental release of radiation and sabotage of nuclear processes. These norms would also include instances where an unwitting attacker or intelligence collection entity inadvertently makes their way into a nuclear facility network or system and can recognize they are in a protected zone and an approach to ensuring that these zones are not exploitable by bad actors to place their sensitive cyber effect delivery systems.

99 GENERAL AND MISCELLANEOUS↗

Optical communications link design for the tracking and data acquisition system

The communications performances of laser intersatellite links for a future NASA data-relay system are analyzed, and block diagrams of necessary optical terminals are generated based on technology projected to be available by 1992. Direct-detection optical communications subsystems are selected to interconnect two geosynchronous (GEO) satellites separated by 160 deg along the GEO arc and to interconnect a low-earth-orbit (LEO) satellite and either of the GEO satellites. The terminal designs are based on power budget calculations performed for the various links with and without an optical background in either the receiver or transmitter fields of view (FOVs). Optical antennas with 18-cm and 30-cm primary mirror diameters on the LEO and GEO satellites can achieve a 0.000001 average bit error rate during normal operations in each of the forward and return optical links with beginning-of-life (BOL) power margins of approximately 7 dB. With an optical background in the receiver FOV, communications in the GEO-GEO return link are interrupted, the LEO-GEO return link is undegraded, and the GEO-GEO and LEO-GEO forward links remain functional with reduced BOL power margins. With an optical background in the transmitter FOV, the GEO-GEO forward and return links are noticeably degraded, the LEO-GEO return link is only slightly degraded, and the LEO-GEO forward link remains undegraded.

Marshalek, R. G.↗

Enhanced plasma current collection from weakly conducting solar array blankets

Among the solar cell technologies to be tested in space as part of the Solar Array Module Plasma Interactions Experiment (SAMPIE) will be the Advanced Photovoltaic Solar Array (APSA). Several prototype twelve cell coupons were built for NASA using different blanket materials and mounting techniques. The first conforms to the baseline design for APSA which calls for the cells to be mounted on a carbon loaded Kapton blanket to control charging in GEO. When deployed, this design has a flexible blanket supported around the edges. A second coupon was built with the cells mounted on Kapton-H, which was in turn cemented to a solid aluminum substrate. A final coupon was identical to the latter but used germanium coated Kapton to control atomic oxygen attack in LEO. Ground testing of these coupons in a plasma chamber showed considerable differences in plasma current collection. The Kapton-H coupon demonstrated current collection consistent with exposed interconnects and some degree of cell snapover. The other two coupons experienced anomalously large collection currents. This behavior is believed to be a consequence of enhanced plasma sheaths supported by the weakly conducting carbon and germanium used in these coupons. The results reported here are the first experimental evidence that the use of such materials can result in power losses to high voltage space power systems.

Hillard, G. Barry↗

Analyzing the Deployment of Large Amounts of Offshore Wind to Design an Offshore Transmission Grid in the United States: Preprint

This paper revisits the results from the U.S. Department of Energy's '20% Wind Energy By 2030' study, which envisioned that 54 GW of offshore wind would be installed by said year. The analysis is conducted using the Regional Energy Deployment System (ReEDS), a capacity expansion model developed by the National Renewable Energy Laboratory. The model is used to optimize the deployment of the 54 GW of wind capacity along the coasts and lakes of the United States. The graphical representation of the results through maps will be used to provide a qualitative description for planning and designing an offshore grid. ReEDS takes into account many factors in the process of siting offshore wind capacity, such as the quality of the resource, capital and O&M costs, interconnection costs, or variability metrics (wind capacity value, forecast error, expected curtailment). The effect of these metrics in the deployment of offshore wind will be analyzed through examples in the results.

17 WIND ENERGY↗

Vacuum MOCVD fabrication of high efficience cells

Vacuum metal-organic-chemical-vapor-deposition (MOCVD) is a new fabrication process with improved safety and easier scalability due to its metal rather than glass construction and its uniform multiport gas injection system. It uses source materials more efficiently than other methods because the vacuum molecular flow conditions allow the high sticking coefficient reactants to reach the substrates as undeflected molecular beams and the hot chamber walls cause the low sticking coefficient reactants to bounce off the walls and interact with the substrates many times. This high source utilization reduces the materials costs power device and substantially decreases the amounts of toxic materials that must be handled as process effluents. The molecular beams allow precise growth control. With improved source purifications, vacuum MOCVD has provided p GaAs layers with 10-micron minority carrier diffusion lengths and GaAs and GaAsSb solar cells with 20% AMO efficiencies at 59X and 99X sunlight concentration ratios. Mechanical stacking has been identified as the quickest, most direct and logical path to stacked multiple-junction solar cells that perform better than the best single-junction devices. The mechanical stack is configured for immediate use in solar arrays and allows interconnections that improve the system end-of-life performance in space.

Partain, L. D.↗

Damage spreading in spatial and small-world random boolean networks

Random Boolean Networks (RBNs) are often used as generic models for certain dynamics of complex systems, ranging from social networks, neural networks, to gene or protein interaction networks. Traditionally, RBNs are interconnected randomly and without considering any spatial arrangement of the links and nodes. However, most real-world networks are spatially extended and arranged with regular, small-world, or other non-random connections. Here we explore the RBN network topology between extreme local connections, random small-world, and random networks, and study the damage spreading with small perturbations. We find that spatially local connections change the scaling of the relevant component at very low connectivities ({bar K} << 1) and that the critical connectivity of stability K{sub s} changes compared to random networks. At higher {bar K}, this scaling remains unchanged. We also show that the relevant component of spatially local networks scales with a power-law as the system size N increases, but with a different exponent for local and small-world networks. The scaling behaviors are obtained by finite-size scaling. We further investigate the wiring cost of the networks. From an engineering perspective, our new findings provide the key trade-offs between damage spreading (robustness), the network wiring cost, and the network's communication characteristics.

42 ENGINEERING↗

Failure stress comparison of different pairings of Ag-plating and reflow-oven-processed pressureless-sintered-Ag interconnects

Here, sintered-silver is a candidate material to supplant solders for interconnects in power electronic packaging for many reasons including its desirably high electrical and thermal conductivities and compliance to Restriction of Hazardous Substances (RoHS) guidelines. The shear failure stress of interconnects though is limited by whatever constituent is the weakest, and that includes any employed plating. In the present study, silver-platings were processed electrolytically, electrolessly, and through sputter deposition and their influence on the entire “interconnect system” shear strength was examined. Test sets employing gold plating and no plating were included for comparison and to aid interpretation. Ambient-air, reflow-oven-processed, pressureless-sintered-silver interconnects were identically fabricated with all plating test sets. It was found that all considered silver-plating methods produced consistently strong (characteristic failure stresses > 55 MPa) sintered-silver interconnects. Because failures tended to be adhesive in all six sets, differences in failure stress among the silver-plated sets and the gold-plated or unplated sets were likely due to differences in the adhesive strength of the sintered silver with silver-plating, gold-plating, or direct bonding with copper.

36 MATERIALS SCIENCE↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Effects of voltage control in utility interactive dispersed storage and generation systems

When a small generator is connected to the distribution system, the voltage at the point of interconnection is determined largely by the system and not the generator. The effect on the generator, on the load voltage and on the distribution system of a number of different voltage control strategies in the generator is examined. Synchronous generators with three kinds of exciter control are considered, as well as induction generators and dc/ac inverters, with and without capacitor compensation. The effect of varying input power during operation (which may be experienced by generators based on renewable resources) is explored, as well as the effect of connecting and disconnecting the generator at ten percent of its rated power. Operation with a constant slightly lagging factor is shown to have some advantages.

Kirkham, H.↗

Development and refinement of test bed simulations

Lewis Research Center of NASA, with support from Rocketdyne, was engaged in non-real time computer simulation effort for the Space Station Freedom Electric Power System (EPS) EASY5, a simulation package, is used as the primary tool for this activity. Early in the design of the EPS, two test beds were set up at Lewis. The Integrated Test Bed (ITB), that combines and upgrades these test beds, is in the planning stage. The test beds are designed to functionally represent many of the components of the EPS and their interconnections. The simulation effort is primarily directed towards these test beds. Model verification is performed using test bed data.

Dravid, Narayan V.↗

Development and refinement of test bed simulations

Lewis Research Center of NASA, with support from Rocketdyne, has engaged in a nonreal-time computer simulation effort for the Space Station Freedom Electric Power System (EPS). EASYS, a simulation package, is used as the primary tool for this activity. Early in the design of the EPS, two test beds were set up at Lewis. The Integrated Test Bed (ITB) that combines and upgrades these test beds is in the planning stage. The test beds are designed to functionally represent many of the components of the EPS and their interconnections. The simulation effort is primarily directed towards these test beds. Model verification is performed using test bed data.

Dravid, N. V.↗

Using the System Complexity Metric (SCM) to Compare CO2 Removal Systems

A fundamental cause of difficulty in large engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, where there is no obvious mental model that correctly predicts its behavior. Higher system complexity is usually associated with higher cost and higher failure rate. Complexity is perceived if a system has many diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and unanticipated failure modes. Identifying and removing these signs of complexity should improve performance and reduce the cost and failure rate. Complexity can be directly measured by the number of components and their interactions. The System Complexity Metric (SCM) is defined as the sum of the number of parts in a system, N, plus the number of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of the system block diagram. SCM can be used to compare systems and to guide their redesign to reduce cost and failure rate. Carbon dioxide removal systems are analyzed using SCM, cost, and failure rate. As in previous work, cost is directly proportional to SCM and that failure rate increases as a power of SCM for large differences in SCM. The SCM ranking of carbon dioxide removal systems is the same as their ranking in detailed analysis and practice.

Harry W. Jones↗

Using the System Complexity Metric (SCM) to Compare CO2 Reduction Systems

A fundamental cause of difficulty in large engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, where there is no obvious mental model that correctly predicts its behavior. Higher system complexity is usually associated with higher cost and higher failure rate. Complexity is perceived if a system has many diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and unanticipated failure modes. Identifying and removing these signs of complexity should improve performance and reduce the cost and failure rate. Complexity can be directly measured by the number of components and their interactions. The System Complexity Metric (SCM) is defined as the sum of the number of parts in a system, N, plus the number of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of the system block diagram. SCM can be used to compare systems and to guide their redesign to reduce cost and failure rate. Carbon dioxide reduction systems are analyzed using SCM, cost, and failure rate. As in previous work, cost is directly proportional to SCM and that failure rate increases as a power of SCM for large differences in SCM. The SCM ranking of carbon dioxide reduction systems is the same as their ranking in detailed analysis and practice.

Harry W. Jones↗

Experiences from Field Testing for Black Start of a Run-of-the-river Hydropower Plant in Idaho Falls Power Distribution Grid

Idaho Falls Power (IFP) utility has local generation portfolio comprising of 56.3MVA of run-of-the-river (ROR) hydropower that can serve typically 25%-30% of the total load demand. The remaining load is served by importing power from Bonneville Power Administration through two Pacificorp transmission interconnections. In case of emergencies (power disruption or directed load reduction), the capability to island from transmission grid and stably serve critical loads in the IFP distribution grid can be a huge advantage. In this direction, the capability to black start with ROR is an essential requirement, and a challenge due to limited dispatchability and requires re-tuning of hydro-governor and excitation system controls. This paper presents the field experience from the testing done for black start of 8.9 MW ROR hydro plant in the IFP distribution grid using an adjustable load bank in December 2017. The lessons from the successful black start testing is presented along with test results to establish the potential value and requirements to develop black start capability with a ROR hydro plant.

13 HYDRO ENERGY↗

Online Power System Event Detection via Bidirectional Generative Adversarial Networks

Accurate and speedy detection of power system events is critical to enhancing the reliability and resiliency of power systems. Although supervised deep learning algorithms show great promise in identifying power system events, they require a large volume of high-quality event labels for training. This paper develops a bidirectional anomaly generative adversarial network (GAN)-based algorithm to detect power system events using streaming PMU data, which does not rely on a huge amount of event labels. By introducing conditional entropy constraint in the objective function of GAN and graph signal processing-based PMU sorting technique, our proposed algorithm significantly outperforms state-of-the-art event detection algorithms in terms of accuracy. To facilitate the adoption of the proposed algorithm, a prototype online platform is also developed using Apache Hadoop, Kafka, and Spark to enable real-time event detection. Here, the accuracy and computational efficiency of the proposed algorithm are validated using a large-scale real-world PMU dataset from the Eastern Interconnection of the United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Double-Sided Pressureless-Sintered-Silver Interconnects Fabricated by Reflow-Oven-Processing

A significant amount of development with sintered-silver as an alternative interconnect (or attachment or attach) material in power electronic devices has occurred since ~ 2010 at Oak Ridge National Laboratory's National Transportation Research Center. Continuous sponsorship of the work enabled improvements and understanding of several sequential processing steps which otherwise would not have occurred with a short duration or an intermittently funded project. The majority of that work has occurred with a focus on improving its processing and consequential mechanical reliability of the interconnect while promoting adaptability to power elect ronic device manufacturing. The work includes determining application issues of silver-sintering and the developing processes that would make it amenable for use with reflow oven sintering. As part of that work, co-development of maximum interconnect strength of the sintered-silver interconnect occurred, and that also involved examining candidate plating materials that could be used in concert with them for the "interconnect system". All of this work involved the consideration of a single sintered-silver interconnect.

36 MATERIALS SCIENCE↗

Automated Cyber Security Testing Platform for Industrial Control Systems

Nuclear Power Plants (NPPs) are a complex system of coupled physics controlled by a network of Programmable Logic Controllers (PLCs). These PLCs communicate process data across the network to coordinate control actions with each other and inform the operators of process variables and control decisions. Networking the PLCs allows more effective process control and provides the operator more information which results in more efficient plant operation. This interconnectivity creates new security issues, as operators have more access to the plant controls, so will bad actors. As plant networks become more digitized and encompass more sophisticated controllers, the network surface exposed to cyber interference grows. Understanding the dynamics of these coupled systems of physics, control logic, and network communications is critical to their protection. The research into the cybersecurity of the Operational Technologies of NPPs is developing and requires a platform that can allow high fidelity physics simulations to interact with digital networks of controllers. This will require three main components: a network simulation environment, a physics simulator, and virtual PLCs (vPLC) that represent typical industry hardware. A platform that incorporates these three components to provide the most accurate representation of actual NPP networks and controllers is developed in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗