Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Resilient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning From Demonstrations to Assist Service Restoration in Islanded Microgrids

Microgrids can be operated in island mode during utility grid outages to support service restoration and improve system resilience. To schedule and dispatch distributed energy resources (DERs) in an islanded microgrid, conventional model-based methods rely on accurate distribution network models and lack generalization and adaptability. Data-driven methods are promising for DER coordination but face practical challenges such as potential hazards to microgrids during online training and insufficient online training opportunities due to low outage rates. This paper presents a novel two-stage learning framework that builds on the deep deterministic policy gradient from demonstrations to identify an optimal restoration strategy. At the pre-training stage, imitation learning is applied to equip the control agent with expert experiences to guarantee acceptable initial performance. At the online training stage, action clipping, reward shaping, and expert demonstrations are leveraged to ensure safe exploration while accelerating the training process. In conclusion, the proposed method is illustrated using the IEEE 123-node system and compared with a representative model-based method and the standard deep deterministic policy gradient method to prove solution accuracy and demonstrate increased computational efficiency.

Du, Yan↗

Sandia Nuclear Cartridge Concept

Nuclear power offers the promise of long-term electrical power for remote areas. Recent advances in passive safety and long-life cores make a reactor that can be operated autonomously for 20 years or more a real possibility. This white paper discusses a reactor concept that offers the potential for further development, resulting in a permanently hermetically-sealed "nuclear cartridge." The term "nuclear cartridge" is meant to imply a nuclear energy source that can be inserted into a site and operated autonomously until its energy has been depleted, then withdrawn and replaced by another cartridge. The concept can be scaled for various sizes, ranging from about 1 megawatt-electric (MWe) to about 100 MWe. The paper also discusses the concept of Integrated Safety, Operations, Security, and Safeguards (ISOSS) by design as it applies to this reactor design. Finally, a discussion of smart grids and how they can benefit the transfer of power to the end user is included. The Nuclear Cartridge concept has been developed with the following characteristics in mind: highly reliable autonomous operation coupled with international monitoring, requiring minimal on-site operations personnel; walkaway passively safe design; cartridge replacement cycle on the order of 20 years; load following capability; physical security by design requiring minimal security personnel during operations; and proliferation resistance by design. As illustrated in figure 1, integrating the reactor with advanced power conversion, smart grids, and other sources of energy results in a resilient and sustainable energy source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber Security Primer for DER Vendors Aggregators and Grid Operators

This report provides an introduction to cyber security for distributed energy resources (DER) - such as photovoltaic (PV) inverters and energy storage systems (ESS). This material is motivated by the need to assist DER vendors, aggregators, grid operators, and broader PV industry with cyber security resilience and describe the state-of-the-art for securing DER communications. The report outlines basic principles of cyber security, encryption, communication protocols, DER cyber security recommendations and requirements, and device-, aggregator-, and utility-level security best practices to ensure data confidentiality, integrity, and availability. Example cyber security attacks, including eavesdropping, masquerading, man-in-the-middle, replay attacks, and denial-of-service are also described. A survey of communication protocols and cyber security recommendations used by the DER and power system industry are included to elucidate the cyber security standards landscape. Lastly, a roadmap is presented to harden end-to-end communications for DER with research and industry engagement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Survey and Gap Prioritization of U.S. Electric Vehicle Charge Management Deployments

The goal of this study was to survey and characterize the scope of current technical and programmatic knowledge pertaining to EV charge management technologies and practices in the US and relevant international jurisdictions. This characterization of existing field demonstrations and knowledge derived were used to determine gaps in the SCM demonstration landscape. Addressing these gaps through research and demonstration could increase confidence in the U.S. that load management and EV charge control could achieve overarching societal benefits. A survey of charge management deployments and input from stakeholders was completed to determine the state-of-the-art of smart charge management (SCM) where SCM is defined as controlling the amount of power exchanged between chargers and EVs to meet customers' charging needs while also responding to external power demand or pricing signals to provide load management, resilience, or other benefits to the customer and electric grid. The survey was the basis of the gap analysis in this report and determines which areas are well understood, with high confidence, and which areas need further investigation. Existing examples of EV charge management are characterized here to determine aspects that are ready for widespread deployment and have been demonstrated in the field. These include demonstration studies, pilots, programs, and EV-specific tariffs. In all, 110 examples of charge management were characterized. The data sources were public literature and utility filings as well as targeted interviews. In addition, 43 interviews with stakeholders were conducted with a consistent set of questions used in each interview. This study prioritized gaps in demonstrated SCM capabilities based on 1) Urgency of the particular use-case to offset traditional grid assets, 2) Impact, extensibility, and scaling of results across the entire spectrum of 3000+ utility service territories including projected technical and market potential for a given grid service, and 3) Value of federal funding in addressing the gap, including potential to leverage and/or add scope to existing field demonstrations funded by other non-federal funding mechanisms.

33 ADVANCED PROPULSION SYSTEMS↗

State Requirements for Electric Distribution System Planning

Utilities have conducted distribution planning since they first began building and operating electricity systems. But filing these plans for regulatory and stakeholder review is a relatively recent phenomenon. This report summarizes legislative and regulatory requirements for regulated electric utilities to file some type of distribution system plan in 20 U.S. jurisdictions. Some plans focus on expedited cost recovery for certain types of distribution system improvements; other plans focus on investments for grid modernization or distributed energy resources. Increasingly, states are adopting requirements for Integrated Distribution Plans. Such plans provide holistic grid investment strategies that address state and local policies and increasing complexity at the grid edge. The report covers the following topics for distribution system plans, highlighting advanced practices: -State goals and objectives -Procedural requirements -Forecasting loads and distributed energy resources -Hosting capacity analysis -Baseline information requirements -Grid modernization strategy -Grid needs assessment -Non-wires solutions -Reliability and resilience analyses -Stakeholder engagement -Equity -Pilots -Coordination with other planning processes The report includes links to legislation; regulatory requirements, proceedings, and orders; and filed utility plans. The U.S. Department of Energy’s Office of Electricity provided funding support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fostering a Guiding Multiscale Model for the Development of Advanced MgB 2 Hydrogen Storage Materials (Final Technical Report)

Project Goal and Objective. The demand for energy and for an upgraded energy infrastructure has steadily grown, as have the needs for energy independence and alternatives to our reliance on petroleum. Hydrogen is considered the most viable fuels for wide-scale implementation in the near future as it is less-polluting, non-toxic, and has more stored energy than petroleum. It is envisioned that hydrogen can eventually become the prime energy carrier, integrating the transportation, grid, and chemical sectors in a way that improves resiliency, diversifies feedstocks, and affords new economic opportunities. A key remaining challenge is the development materials with enhanced gravimetric and volumetric hydrogen storage capacities that offer a higher performance than compressed gas. These materials would eliminate the need for large-scale compression, thereby dramatically reducing the footprint and cost of gas storage. The high gravimetric and volumetric hydrogen capacities of complex hydrides has prompted an intensive investigation of the potential of this class of materials as hydrogen storage media over the past 25 years. Among the many complex hydrides that have been explored, magnesium borohydride, Mg(BH 4 ) 2 , has been found to possess the best combination of practical thermodynamic properties. These include a gravimetric H 2 density of 14.9 wt% H 2 and thermodynamics for the dehydrogenation of Mg(BH 4 ) 2 to MgB 2 (equation 1) (ΔH° = 39 kJ/mol H 2 , ΔS = 112 J/K mol H 2 ) which lie in the narrow window required Mg(BH 4 ) 2 $\Leftrightarrow$ MgB 2 + 4 H 2 (1) for reversibility under moderate pressure and temperature. However, overcoming the extremely slow kinetics of the reversible release of hydrogen by this material in the solid state is a daunting challenge. At temperatures greater than 400 °C, the borohydride releases up to 14 wt% hydrogen giving MgB 2 . We discovered that the direct re-hydrogenation of MgB 2 to Mg(BH 4 ) 2 can be accomplished under 950 bar H 2 at 400 °C. While this demonstrated that complete reversibility can be achieved, the conditions employed are far too extreme for commercial hydrogen storage applications. More recently, we found through US DOE funded research projects (EERE HyMARC and HySCOR), that hydrogen cycling, can be accomplish at much milder conditions upon modification of the borohydride or boride. Guided by these discoveries these discoveries, the objective of this research project was to obtain key information that will enable the development of a model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 . The ultimate goal of our efforts is to attain a model of this transformation that can be utilized to accelerate development further advanced materials. This project directly follows on discoveries that were made over the course of a US DOE, EERE HyMARC project that was focused on improvement of the hydrogen cycling kinetics of modified MgB 2 . We found that that mechanical milling with graphene results the desired, pronounced kinetic enhancement. The dramatic lowering of the conditions required for the hydrogenation of MgB 2 is a significant step towards overcoming its chemical inertness allowing its development as a practical onboard hydrogen storage material. However, the exact nature of the modification(s) of MgB 2 that is responsible for its activation towards hydrogenation is completely unknown. This situation is not unique, as efforts to develop hydrogen storage materials typically have a narrow focus rather than a comprehensive approach that takes atomic level bonding and structure; molecular dynamics; long range, nano- and mesoscale-structure and their interconnection all into account. The goal of this project was the development of a comprehensive, multi-scale computational model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 that can be utilized for development of higher performance versions of the modified material. Development of the model requires determination of: 1) the bulk, nano-scale, and meso-scale structural changes occurring at elevated pressure following mechano-chemical modification of MgB 2 ; 2) the reaction pathway of the reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 ; 3) the effect of elevated pressure and mechano-chemical modification on the chemical reaction pathways; 4) the interactions at solid-gas interfaces; and particle surfaces; and 5) the kinetics and thermodynamic parameters associated with each step of the hydrogenation reaction pathway. This investigation required advanced techniques as preliminary, standard XRD, 11 B NMR, and FTIR analysis showed no signs of material modification. In order to gain this level of understanding of modified MgB 2 , required the teaming of a diverse group of experts and state-of-the art experimental capabilities at the University of Hawaii at Manoa (UHM) and collaborating National Laboratories: Craig Jensen , Department of Chemistry (PI and Project Director), solid state, solution, and high pressure NMR spectroscopy; solid-state synthesis; and high pressure hydrogenation (collaboration with SNL); Godwin Severa , Hawaii Natural Energy Institute (co-PI) calorimetry; infrared and Raman spectroscopy (collaboration with NREL); Dera , high pressure X-ray diffraction including in situ experiments (collaboration with ANL); Hope Ishii , Hawaii Institute of Geophysics electron microscopy investigations (collaboration with LBNL); and Joe Brown , Mechanical Engineering , material electronic structure and electric field effects.

08 HYDROGEN↗

Considerations for Fire Service Response to Residential Battery Energy Storage System Incidents

Renewable energy sources (e.g., rooftop photovoltaics, wind turbines) are capable of addressing our grid-level energy challenges by reducing environmental impacts, increasing resiliency, and increasing the supply of input energy. However, renewable energy sources alone are not a complete solution. The generation of power from major renewable energy sources fluctuates with the weather, creating significant challenges in matching electrical power generation to electrical power consumption. The value of renewable power generation sources is multiplied when paired with battery energy storage systems (ESS), which can store excess power generated from renewable energy sources when it is not consumed and deliver that power later when demand exceeds base power generation. Residential ESS units are frequently installed to support renewable energy initiatives by storing energy from intermittent sources such as photovoltaic panels. Residential ESS units also offer an alternative to gas-powered generators or other backup power means. Lithium-ion batteries are the most common residential ESS technology due to their affordability and energy density. Though lithium-ion systems come with benefits, there is also a risk of thermal runaway within this technology which can result in flammable gas release, fire, and explosion. As the installations of these products increase, the frequency of response to fire incidents involving these products will increase. In response to this new and evolving hazard, UL Solutions (ULS) and UL Fire Safety Research Institute (FSRI) have partnered with the International Association of Fire Fighters (IAFF) to conduct a series of large-scale tests sponsored by the US Department of Energy to characterize the challenges for fire fighters responding to fires involving residential energy storage systems. The project focuses on developing size-up and tactical considerations to support the fire service in navigating the evolving modern fireground.

25 ENERGY STORAGE↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Measurement of ion transport properties in ion exchange membranes for photoelectrochemical water splitting

Photoelectrochemical (PEC) water-splitting systems have the unique ability to produce renewable hydrogen directly from sunlight, independent of the electrical grid. These systems are therefore appealing technological options for resilient long-term energy storage. Ion selective membranes, such as monopolar and bipolar membranes, are a vital component of PEC water-splitting systems. These membranes allow for ionic conduction between the cathode and anode chambers, separation of products, and improved catalyst environments for reactions. In order to measure key properties and to study the performance of these ion exchange membranes, it is imperative to develop a robust testing protocol that can be used across the field. This paper introduces two standard electrochemical cells designed to directly measure ion transport properties in monopolar and bipolar membranes. The first electrochemical cell uses commercially available Pt disk electrodes to preform electrochemical impedance spectroscopy (EIS) and reliably measure through-plane conductivity of monopolar membranes. The second electrochemical cell uses four-point measurements with Luggin capillaries and a series of membrane configurations to perform current density-voltage and Faradaic efficiency (FE) measurements for water dissociation (WD) reactions on bipolar membranes. The cell designs and techniques laid out below allow for accurate measurement of ion transport parameters in ion exchange membranes, direct comparison of membranes being developed across the field, and in turn, greater advancements in ion exchange membranes and PEC water-splitting systems.

cation exchange membrane↗

HydroWIRES Overview

The U.S. electricity system is rapidly evolving, bringing both opportunities and challenges for hydropower and pumped storage hydropower (PSH). In response to this challenge, the Water Power Technologies Office (WPTO) has launched a new grid research initiative—Hydropower and Water Innovation for a Resilient Electricity System (HydroWIRES)—to understand, enable, and improve hydropower and PSH’s contributions to reliability, resilience, and integration in a rapidly evolving electricity system. Efforts under this initiative are organized in four interrelated research areas: Value Under Evolving System Conditions Capabilities and Constraints Operations and Planning Technology Innovation

water, hydrowires, PSH, hydrokinetic↗

Cyber Security and Resilient Systems

The Department of Energy (DOE) Idaho National Laboratory (INL) has become a center of excellence for critical infrastructure protection, particularly in the field of cyber security. It is one of only a few national laboratories that have enhanced the nation’s cyber security posture by performing industrial control system (ICS) vendor assessments as well as user on-site assessments. Not only are vulnerabilities discovered, but described actions for enhancing security are suggested – both on a system-specific basis and from a general perspective of identifying common weaknesses and their corresponding corrective actions. These cyber security programs have performed over 40 assessments to date which have led to more robust, secure, and resilient monitoring and control systems for the US electrical grid, oil and gas, chemical, transportation, and many other sectors. In addition to cyber assessments themselves, the INL has been engaged in outreach to the ICS community through vendor forums, technical conferences, vendor user groups, and other special engagements as requested. Training programs have been created to help educate all levels of management and worker alike with an emphasis towards real everyday cyber hacking methods and techniques including typical exploits that are used. The asset owner or end user has many products available for its use created from these programs. One outstanding product is the US Department of Homeland Security (DHS) Cyber Security Procurement Language for Control Systems document that provides insight to the user when specifying a new monitoring and control system, particularly concerning security requirements. Employing some of the top cyber researchers in the nation, the INL can leverage this talent towards many applications other than critical infrastructure. Monitoring and control systems are used throughout the world to perform simple tasks such as cooking in a microwave to complex ones such as the monitoring and control of the next generation fighter jets or nuclear material safeguards systems in complex nuclear fuel cycle facilities. It is the intent of this paper to describe the cyber security programs that are currently in place, the experiences and successes achieved in industry including outreach and training, and suggestions about how other sectors and organizations can leverage this national expertise to help their monitoring and control systems become more secure.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Distributed renewable energy resource trust metrics and secure routing

To ensure reliable and predictable service in the electrical grid between distributed renewable distributed energy resources (DERs) it is important to gauge the level of trust present within critical components and DER aggregators (DERAs). Although trust throughout a smart grid is temporal and dynamically varies according to measured states, it is possible to accurately formulate communications and service level strategies based on such trust measurements. Utilizing an effective set of machine learning and statistical methods, it is shown that establishment of trust levels between DERAs using behavioral pattern analysis is possible. Further, it is also shown that the establishment of such trust can facilitate simple secure communications routing between DERAs. Providing secure routing between DERAs enables a grid operator to maintain service level agreements to its customers, reduce the attack surface and increase operational resiliency.

97 MATHEMATICS AND COMPUTING↗

Outage Forecast-Based Preventative Scheduling Model for Distribution System Resilience Enhancement

Distribution system resilience enhancement is an important topic to ensure customers have access to power supply during extreme events. In fact, certain weather-related extreme events can be predicted ahead of time. Therefore, it is important to investigate how to predict grid outages using extreme weather forecasts, and how outage predictions can be incorporated into distribution system resilience enhancement. In this paper, a preventative scheduling model for distribution systems is proposed. The model targets at allocating resources, especially mobile responsive resources such as mobile backup generators and mobile energy storage systems, to prepare for an extreme event in the day-ahead context. To achieve efficient resource allocation and scheduling, a machine learning-based outage prediction module is developed to predict vulnerable or risky segments of the distribution system based on historical operating records and extreme weather event forecast. By integrating the outage prediction results into the scheduling model, optimal resource allocation can be derived to help distribution systems prepare for an upcoming event and improve resilience performance. A real distribution feeder in North Carolina, U.S. is used in the case study to validate the proposed approach.

distributed energy resources↗

Smart Building Technology Training Modules for Academic and Professional Education

Smart building technologies are a new suite of resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both college curricula and building professionals’ continuing education, there is a lack of systematic instruction on smart building technologies–topics that include smart building concepts, key components, smart building controls, “Internet of Things” (IoT) devices, and how to integrate multiple energy systems including distributed energy resources (DER). This major gap in smart building education prevents stakeholders from understanding and adopting smart building technologies in building design and operations. Slipstream leads a DOE-funded project developing a semester-long smart building curriculum for college students and adapting the contents into 16 training videos for building professionals and the general public. The education and training cover the drivers and benefits of smart building technologies, key building energy systems, the latest sensor technologies and IoT devices, and focus on topics related to smart building controls (i.e., energy management information systems, smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content. We also suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies in the real world.

99 GENERAL AND MISCELLANEOUS↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗