Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Video”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Design parameters for a stereoptic television system based on direct vision depth perception cues

Remotely controlled systems which use television for visual feedback require that depth cues be available to the operator. A number of techniques have been developed to provide stereoptic video. An analysis of parameters of such systems as related to the depth cues of convergence and retinal disparity was carried out. Parameter requirements were determined for the provision of natural and exaggerated stereoptic cues and expressions were developed for range resolution limits based on the retinal disparity threshold. An empirical study was conducted using a stereoptic video system to determine threshold values

Shields, N. L., Jr.↗

Health education telecommunications experiment

The Health/Education Telecommunications Experiment (HET) was conducted jointly by NASA and HEW on NASA's ATS-6 communications satellite. This experiment actually consisted of six experiments testing health and education applications of a communication spacecraft producing a broadcast of color television directly from space to over 120 low-cost receivers located in remote rural areas throughout the U.S. (including Alaska). The experiments were conducted over the period from 2 July 1974 to 20 May 1975 and operated on an almost daily basis. The overall telecommunications system to support these experiments consisted of many elements: The ATS-6 spacecraft; five different types of earth stations consisting of 120 video receive terminals, 51 telephony tranceivers and eight video originating terminals of three different types. Actual performance of the equipment as measured in the field was shown to equal or exceed predicted values.

Whalen, A. A.↗

Solid State Television Camera (CID)

The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.

Steele, D. W.↗

Sector-scanning echocardiography

The mechanical sector scanner is described in detail, and its clinical application is discussed. Cross sectional images of the heart are obtained in real time using this system. The sector scanner has three major components: (a) hand held scanner, (b) video display, and (c) video recorder. The system provides diagnostic information in a wide spectrum of cardiac diseases, and it quantitates the severity of mitral stenosis by measurement of the mitral valve orifice area in diagnosing infants, children and adults with cyanotic congenital heart disease.

Henry, W. L.↗

Computer-aided analysis of CCD linear image sensors

Special test equipment and techniques to collect and process image information from charge coupled devices (CCDs) by digital computer were reviewed. The video channel was traced from the CCD to the direct memory access bus of the Interdata Computer. Software was developed to evaluate and characterize a CCD for (1) dark signal versus temperature relationship, (2) calculation of temporal noise magnitude and noise shape for each pixel, (3) spatial noise into the video chain due to dark signal, (4) response versus illumination relationship (gamma), (5) response versus wavelength of illumination (spectral), (6) optimization of forcing functions, and (7) evaluation of an image viewed by a CCD. The basic software differences and specific examples of each program operating on real data are presented.

Prince, S. S.↗

Description and flight tests of an oculometer

A remote sensing oculometer was successfully operated during flight tests with a NASA experimental Twin Otter aircraft at the Langley Research Center. Although the oculometer was designed primarily for the laboratory, it was able to track the pilot's eye-point-of-regard (lookpoint) consistently and unobtrusively in the flight environment. The instantaneous position of the lookpoint was determined to within approximately 1 deg. Data were recorded on both analog and video tape. The video data consisted of continuous scenes of the aircraft's instrument display and a superimposed white dot (simulating the lookpoint) dwelling on an instrument or moving from instrument to instrument as the pilot monitored the display information during landing approaches.

Middleton, D. B.↗

LANDSAT-1 and LANDSAT-2 flight evaluation report

The LANDSAT-1 spacecraft was launched from the Western Test Range on 23 July 1972, at 18:08:06.508Z. The launch and orbital injection phase of the space flight was nominal and deployment of the spacecraft followed predictions. Orbital operations of the spacecraft and payload subsystems were satisfactory through Orbit 147, after which an internal short circuit disabled one of the Wideband Video Tape Recorders (WBVTR-2). Operations resumed until Orbit 196, when the Return Beam Vidicon failed to respond when commanded off. The RBV was commanded off via alternate commands. LANDSAT-1 continued to perform its imaging mission with the Multispectral Scanner and the remaining Wideband Video Tape Recorder providing image data.

Source record↗

The response of fluoroscopic image intensifier-TV systems

Three different types of X-ray fluoroscopic TV chains were investigated: two standard clinical units, one with a vidicon camera tube, the other with a plumbicon camera tube; and the third was a large flat-screen unit. In each an X-ray beam generated at 100 kVp was passed through 10 cm of H2O before aluminum absorbers of varying thickness were introduced. Five video recordings were made at each absorber thickness. The video image was digitized directly from the disk recording and quantized into 128 gray levels. The five recordings were averaged on a point-to-point basis, and the central 900 averaged points were again averaged to yield a value for the gray level assigned to each particular image. This 30 by 30 matrix of points corresponds to input screen areas of 29, 8.2, and 3.6 sq cm for the three units investigated.

Baily, N. A.↗

Regional myocardial shape and dimensions of the working isolated canine left ventricle

Angiographic experiments were performed on isolated canine left ventricle preparations using donor dog to supply blood to the coronary circulation via a rotary pump to control coronary flow. The angiographic record was transferred from video tape to video disk for detailed uninterrupted sequential analysis at a frequency of 60 fields/sec. It is shown that the use of a biplane X-ray technique and a metabolically supported isolated canine left ventricle preparation provides an angiographically ideal means of measuring the mechanical dynamics of the myocardium while the intact left ventricular myocardial structure and electrical activation pattern retain most of the in situ ventricular characteristics. In particular, biplane X-ray angiography of the left ventricle can provide estimates of total ventricular function such as ejection fraction, stroke volume, and myocardial mass correct to within 15% under the angiographically ideal conditions of the preparation.

Ritman, E.↗

Intensified charge coupled devices for ultra low light level imaging

Development of a sensor incorporating a CCD and photocathode for operation in the electron bombarded mode in both a magnetic and an electrostatic focussed, gated configuration is described. Initial format size is 100 x 160 pixels with eventual growth to 400 x 400 pixels. The sensor is part of a digital camera system which includes the low level video conditioning electronics, a camera controller, a high speed buffer memory, and digital recording and display electronics. The memory uses CMOS/SOS and has a capacity of 1.6 Mbits with operating rates of 48 Mbits/sec. Individual frames are co-added to provide wide dynamic range and photometric precision better than 1%. A 4-bit video quantization is used to increase the photon counting detection rate before coincidence losses become serious.

Sobieski, S.↗

Methods and new approaches to the calculation of physiological parameters by videodensitometry

A complex system featuring a video-camera connected to a video disk, cine (medical motion picture) camera and PDP-9 computer with various input/output facilities has been developed. This system enables the performance of quantitative analysis of various functions recorded in clinical studies. Several studies are described, such as heart chamber volume calculations, left ventricle ejection fraction, blood flow through the lungs and also the possibility of obtaining information about blood flow and constrictions in small cross-section vessels

Kedem, D.↗

Simulation of the Effects of Hard Limiting on Image Quality of Synthetic Aperture Radar

Starting with a magnetic tape of a scene viewed by the Landsat satellite, the radar return of reflectors whose average intensity matched that of the picture elements in the scene has been simulated. The returns were processed in three ways: normally or with no quantization, with a procedure simulation IF hard limiting, and with a procedure simulating video (baseband) hard limiting. For each type of processing an image for a one, two, and four-look system has been developed. It was found that IF limiting is slightly better than video limiting, while both can be reasonable trade-offs of image quality for reduced data rates when the number of looks is four or less. These conclusions are supported by photographs representing the different processing techniques.

Lipes, R. G.↗

Fiber optic multiplex optical transmission system

A multiplex optical transmission system which minimizes external interference while simultaneously receiving and transmitting video, digital data, and audio signals is described. Signals are received into subgroup mixers for blocking into respective frequency ranges. The outputs of these mixers are in turn fed to a master mixer which produces a composite electrical signal. An optical transmitter connected to the master mixer converts the composite signal into an optical signal and transmits it over a fiber optic cable to an optical receiver which receives the signal and converts it back to a composite electrical signal. A de-multiplexer is coupled to the output of the receiver for separating the composite signal back into composite video, digital data, and audio signals. A programmable optic patch board is interposed in the fiber optic cables for selectively connecting the optical signals to various receivers and transmitters.

Bell, C. H.↗

Full color hybrid display for aircraft simulators

A full spectrum color monitor, connected to the camera and lens system of a television camera supported by a gantry frame over a terrain model simulating an aircraft landing zone, projects the monitor image onto a lens or screen visually accessible to a trainee in the simulator. A digital computer produces a pattern corresponding to the lights associated with the landing strip onto a monochromatic display, and an optical system projects the calligraphic image onto the same lens so that it is superposed on the video representation of the landing field. The optical system includes a four-color wheel which is rotated between the calligraphic display and the lens, and an apparatus for synchronizing the generation of a calligraphic pattern with the color segments on the color wheel. A servo feedback system responsive to the servo motors on the gantry frame produces an input to the computer so that the calligraphically generated signal corresponds in shape, size and location to the video signal.

Chase, W. D.↗

TV requirements for manipulation in space

Four tasks (docking, coupling, manipulation, and transportation), stressing work volume and element relationships, are outlined to test a video system for remote manipulation in space. A 4 degree of freedom motion frame was used to evaluate operating parameters, which grouped the visual dimensions into major areas of influence, e.g., depth precision, object differentiation, reference, dynamics, and resolution. Four video systems were included in the simulation testing: a black and white and a color monoscopic system, a stereoscopic system, and a black and white two-view system. The two-view system was found best suited for the operations described.

Freedman, L. A.↗

Detected noise levels guide radiometer design

A survey of component demands and design techniques for radiometers is presented. The design of a typical radiometer is traced from the antenna through the video and data-collection stages. Key design equations are given. An example is considered that shows how IF amplifier gain must be chosen to mask video noise. The influence of front-end losses on back-end design is studied.

Schuchardt, J. M.↗

Large Area Silicon Sheet by EFG

Progress made in the development of EFG ribbon growth is discussed. Specific areas covered include: (1) demonstration of multiple growth for ribbons 5 cm wide in runs of 12 and 20 hours duration; (2) a single cartridge crystal growth station was built expanding observational capacity by virtue of an anamorphic optical-video system which allows close observation of the meniscus over 7.5 cm wide, as well as video taping of the ribbon growth process; (3) growth station no.1 achieved reproducible and reliable growth of 7.5 cm wide ribbon at speeds up to 4 cm/min; (4) introduction of the 'mini cold shoe'; (5) increases in cell efficiency due to interface shaping using the 'displaced die' concept; and (6) clarification of the role of gaseous impurities in cartridge furnaces and stabilization of their destabilizing influence on growth.

Wald, F. V.↗

A digital audio/video interleaving system

A method of interleaving an audio signal with its associated video signal for simultaneous transmission or recording, and the subsequent separation of the two signals, is described. Comparisons are made between the new audio signal interleaving system and the Skylab Pam audio/video interleaving system, pointing out improvements gained by using the digital audio/video interleaving system. It was found that the digital technique is the simplest, most effective and most reliable method for interleaving audio and/or other types of data into the video signal for the Shuttle Orbiter application. Details of the design of a multiplexer capable of accommodating two basic data channels, each consisting of a single 31.5-kb/s digital bit stream are given. An adaptive slope delta modulation system is introduced to digitize audio signals, producing a high immunity of work intelligibility to channel errors, primarily due to the robust nature of the delta-modulation algorithm.

Richards, R. W.↗