Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Growth of Homoepitaxial ZnO Semiconducting Films

As a high temperature wide-band-gap (3.3 eV at room temperature) semiconductor, ZnO has been used for many applications such as wave-guides, solar cells, and surface acoustic wave devices, Since ZnO has a 60 meV excitonic binding energy that makes it possible to produce excitonic lasing at room temperature, a recent surge of interest is to synthesize ZnO films for UV/blue/green laser diodes. These applications require films with a smooth surface, good crystal quality, and low defect density. Thus, homoepitaxial film growth is the best choice. Homoepitaxial films have been studied in terms of morphology, crystal structure, and electrical and optical properties. ZnO single crystal substrates grown by the hydrothermal method are mechanically polished and annealed in air for four hours before the films are deposited. The annealing temperature-dependence on ZnO substrate morphology and electrical properties is investigated. Films are synthesized by off-axis reactive sputtering deposition. This produces films that have very smooth surfaces with roughness less than or equal to 5 nm on a 5 microns x 5 microns area. The full width at half maximum of film theta rocking curves measured by the x-ray diffraction is slightly larger than that of the crystal substrate. Films are also characterized by measuring resistivity, optical transmittance, and photoluminescence. The properties of ZnO films grown on (0001) ZnO and (0001) sapphire substrates will also be compared and discussed.

Zhu, Shen↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Two-dimensional high temperature strain measurement system

Two-dimensional optical strain measurements on high temperature test specimens are presented. This two-dimensional capability is implemented through a rotatable sensitive strain axis. Three components of surface strain can be measured automatically, from which the first and second principal strains are calculated. One- and two-dimensional strain measurements at temperatures beyond 750 C with a resolution of 15 microstrain are demonstrated. The system is based on a one-dimensional speckle shift technique. The speckle shift technique makes use of the linear relationship between surface strain and the differential shift of laser speckle patterns in the diffraction plane. Laser speckle is a phase effect that occurs when spatially coherent light interacts with an optically rough surface. Since speckle is generated by any diffusely reflecting surface, no specimen preparation is needed to obtain a good signal. Testing was done at room temperature on a flat specimen of Inconel 600 mounted in a fatigue testing machine. A load cell measured the stress on the specimen before and after acquiring the speckle data. Strain components were measured at 0 C (parallel to the load axis) and at plus or minus 45 C, and plots indicate the calculated values of the first and second principal strains. The measured values of Young's modulus and Poisson's ratio are in good agreement with handbook values. Good linearity of the principal strain moduli at high temperatures indicate precision and stability of the system. However, a systematic error in the high-temperature test setup introduced a scale factor in the slopes of the two-dimensional stress-strain curves. No high temperature effects, however, have been observed to degrade speckle correlation.

Lant, Christian T.↗

CENTAUR - The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source

CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a high-resolution chopper will enable detailed structural and dynamical investigations of magnetic and quantum materials. CENTAUR’s excellent resolution makes it ideal for low-angle diffraction studies of highly ordered large-scale structures, such as skyrmions, shear-induced ordering in colloids, and biomembranes. Additionally, the spectroscopic mode of this instrument extends to lower momentum transfers than are currently possible with existing spectrometers, thereby providing a unique capability for inelastic SANS studies.

47 OTHER INSTRUMENTATION↗

Exploring the High-Pressure Phases of Carbon through X-ray Diffraction of Dynamic Compression Experiments on Sandia’s Z Pulsed Power Facility

The carbon phase diagram is rich with polymorphs which possess very different physical and optical properties ideal for different scientific and engineering applications. An understanding of the dynamically driven phase transitions in carbon is particularly important for applications in inertial confinement fusion, as well as planetary and meteorite impact histories. Experiments on the Z Pulsed Power Facility at Sandia National Laboratories generate dynamically compressed high-pressure states of matter with exceptional uniformity, duration, and size that are ideal for investigations of fundamental material properties. X-ray diffraction (XRD) is an important material physics measurement because it enables direct observation of the strain and compression of the crystal lattice, and it enables the detection and identification of phase transitions. Several unique challenges of dynamic compression experiments on Z prevent using XRD systems typically utilized at other dynamic compression facilities, so novel XRD diagnostics have been designed and implemented. We performed experiments on Z to shock compress carbon (pyrolytic graphite) samples to pressures of 150–320 GPa. The Z-Beamlet Laser generated Mn-Heα (6.2 keV) X-rays to probe the shock-compressed carbon sample, and the new XRD diagnostics measured changes in the diffraction pattern as the carbon transformed into its high-pressure phases. Quantitative analysis of the dynamic XRD patterns in combination with continuum velocimetry information constrained the stability fields and melting of high-pressure carbon polymorphs.

36 MATERIALS SCIENCE↗

Enhanced biochemical sensing with high- Q transmission resonances in free-standing membrane metasurfaces

Optical metasurfaces provide solutions to label-free biochemical sensing by localizing light resonantly beyond the diffraction limit, thereby selectively enhancing light–matter interactions for improved analytical performance. However, high-Q resonances in metasurfaces are usually achieved in the reflection mode, which impedes metasurface integration into compact imaging systems. Here, we demonstrate a metasurface platform for advanced biochemical sensing based on the physics of the bound states in the continuum (BIC) and electromagnetically induced transparency (EIT) modes, which arise when two interfering resonances from a periodic pattern of tilted elliptic holes overlap both spectrally and spatially, creating a narrow transparency window in the mid-infrared spectrum. We experimentally measure these resonant peaks observed in transmission mode (Q ~ 734 at λ ~ 8.8 µm) in free-standing silicon membranes and confirm their tunability through geometric scaling. We also demonstrate the strong coupling of the BIC-EIT modes with a thinly coated PMMA film on the metasurface, characterized by a large Rabi splitting (32 cm -1 ) and biosensing of protein monolayers in transmission mode. Our new photonic platform can facilitate the integration of metasurface biochemical sensors into compact and monolithic optical systems while being compatible with scalable manufacturing, thereby clearing the way for on-site biochemical sensing in everyday applications.

Rosas, Samir [Univ. of Wisconsin, Madison, WI (Uni↗

Alignment Cube with One Diffractive Face

An enhanced alignment cube has been invented for use in a confined setting (e.g., a cryogenic chamber) in which optical access may be limited to a single line of sight. Whereas traditional alignment-cube practice entails the use of two theodolites aimed along two lines of sight, the enhanced alignment cube yields complete alignment information through use of a single theodolite aimed along a single line of sight. Typically, an alignment cube is placed in contact with a datum surface or other reference feature on a scientific instrument during assembly or testing of the instrument. The alignment cube is then used in measuring a small angular deviation of the feature from a precise required orientation. Commonly, the deviation is expressed in terms of rotations (Rx,Ry,Rz) of the cube about the corresponding Cartesian axes (x,y,z). In traditional practice, in order to measure all three rotations, it is necessary to use two theodolites aimed at two orthogonal faces of the alignment cube, as shown in the upper part of the figure. To be able to perform such a measurement, one needs optical access to these two faces. In the case of an alignment cube inside a cryogenic chamber or other enclosed space, the optical-access requirement translates to a requirement for two windows located along the corresponding two orthogonal lines of sight into the chamber. In a typical application, it is difficult or impossible to provide two windows. The present enhanced version of the alignment cube makes it possible to measure all three rotations by use of a single line of sight, thereby obviating a second window.

Ohl, Raymond G.↗

The Circumstellar Imager: Direct detection of extra-solar planetary systems

The Astrometric Imaging Telescope (AIT) is designed to probe the circumstellar environment by both direct imaging and indirect astrometric measurements. The Circumstellar Imager (CI) is a coronagraphic camera and is the direct imaging component of the AIT. The CI is designed to obtain high-sensitivity images of the circumstellar region. It provides crucial non-inferential information relating to the frequency, origin, and evolution of planetary systems and all forms of circumstellar matter. Such imaging is usually limited by the scattered and diffracted light halos of the star itself, which are greatly suppressed in the CI by mating a novel high-efficiency coronagraph with a phase-compensated optical system. For faint point sources in the circumstellar region, the CI will have a sensitivity in excess of 5 magnitudes fainter than the as-designed Hubble Space Telescope (HST). Laboratory data are shown for the coronagraph, which, in a diffraction-limited environment, is capable of suppressing the stellar diffraction sidelobes by several orders of magnitude without significant sacrifice of field of view. In order to realize the high rejection levels inherent in the coronagraph design, it is necessary to limit scatter in the optical systems, imposing a mid-spatial frequency figure error requirement an order of magnitude smaller than that of the HST. Experimental data directed toward meeting this requirement are also shown.

Ftaclas, Christ↗

Liquid crystal devices especially for use in liquid crystal point diffraction interferometer systems

Liquid crystal point diffraction interferometer (LCPDI) systems that can provide real-time, phase-shifting interferograms that are useful in the characterization of static optical properties (wavefront aberrations, lensing, or wedge) in optical elements or dynamic, time-resolved events (temperature fluctuations and gradients, motion) in physical systems use improved LCPDI cells that employ a "structured" substrate or substrates in which the structural features are produced by thin film deposition or photo resist processing to provide a diffractive element that is an integral part of the cell substrate(s). The LC material used in the device may be doped with a "contrast-compensated" mixture of positive and negative dichroic dyes.

Marshall, Kenneth L.↗

Introduction of Chalcogenide Glasses to Additive Manufacturing: Nanoparticle Ink Formulation, Inkjet Printing, and Phase Change Devices Fabrication

Abstract Chalcogenide glasses are one of the most versatile materials that have been widely researched because of their flexible optical, chemical, electronic, and phase change properties. Their application is usually in the form of thin films, which work as active layers in sensors and memory devices. In this work, we investigate the formulation of nanoparticle ink of Ge–Se chalcogenide glasses and its potential applications. The process steps reported in this work describe nanoparticle ink formulation from chalcogenide glasses, its application via inkjet printing and dip-coating methods and sintering to manufacture phase change devices. We report data regarding nanoparticle production by ball milling and ultrasonication along with the essential characteristics of the formed inks, like contact angle and viscosity. The printed chalcogenide glass films were characterized by Raman spectroscopy, X-ray diffraction, energy dispersive spectroscopy and atomic force microscopy. The printed films exhibited similar compositional, structural, electronic and optical properties as the thermally evaporated thin films. The crystallization processes of the printed films are discussed compared to those obtained by vacuum thermal deposition. We demonstrate the formation of printed thin films using nanoparticle inks, low-temperature sintering and proof for the first time, their application in electronic and photonic temperature sensors utilizing their phase change property. This work adds chalcogenide glasses to the list of inkjet printable materials, thus offering an easy way to form arbitrary device structures for optical and electronic applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis, structure, linear and nonlinear optical properties of noncentrosymmetric quaternary diamond-like semiconductors, Cu 2 ZnGeSe 4 (CZGSe) and the novel Cu 4 ZnGe 2 Se 7

In this work, two quaternary diamond-like semiconductors (DLSs) in the Cu-Zn-Ge-Se system, the known Cu 2 ZnGeSe 4 (also referred to as CZGSe) and the new Cu 4 ZnGe 2 Se 7 , are compared in terms of their crystal structures, electronic structures and physicochemical properties. Both compounds were prepared by high-temperature, solid-state synthesis at 800 degrees C. Single crystal X-ray diffraction was used to determine the structure of Cu 4 ZnGe 2 Se 7 . The structures of both Cu 2 ZnGeSe 4 and Cu 4 ZnGe 2 Se 7 can be considered as derivatives of cubic diamond. Cu 4 ZnGe 2 Se 7 , with a reduced symmetry due to the cation ordering pattern, adopts the Cu 4 NiSi 2 S 7 structure type, with space group C2. The corner-sharing tetrahedra in Cu 4 ZnGe 2 Se 7 are slightly distorted because the charge for some of the S 2 - anions is not compensated by the first-nearest-neighbor cations. Rietveld refinements using synchrotron X-ray powder diffraction data were used to assess the phase purity of the samples and confirm the bulk structural behavior. Diffuse reflectance UV/Vis/NIR spectroscopy shows that Cu 2 ZnGeSe 4 and Cu 4 ZnGe 2 Se 7 have direct optical bandgaps of 1.38 and 0.91 eV, respectively. Electronic structure calculations implementing density functional theory confirm the direct bandgap for Cu 4 ZnGe 2 Se 7 , with a calculated value of 0.62 eV. Both compounds are air stable, thermally stable up to relatively high temperatures, undergo phase transitions and have wide windows of optical clarity. The Kurtz-Perry powder technique was used to determine the second harmonic generation (SHG) responses using a commercial AgGaSe 2 standard. While Cu 4 ZnGe 2 Se 7 displays a weak SHG response, Cu 2 ZnGeSe 4 exhibits a response that is greater than several benchmark materials, with a large SHG coefficient, χ (2) , of 43 ± 6 pm/V at λ = 2900 nm.

36 MATERIALS SCIENCE↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗

Size estimates of Titan's aerosols based on Voyager high-phase-angle images

Limits on the physical properties of the scattering haze near the top of Titan's atmosphere are derived from data obtained from seven high-phase-angle images from Voyager 1 and 2. From the ratio of the intensities observed at two different high phase angles, an estimate can be made of the forward-scattering lobe of the single-scattering phase function. Comparing the forward-scattering estimate with diffraction lobes from particles of different radii, it is concluded that the average radius of the particles found in the upper few tenths of an optical depth exceeds 0.19 micron. Judging from data observed at four different phase angles, the haze particles probably have a refractive index near 1.6 and a mean size of about 0.5 micron, if the widths of their diffraction peaks are close to those for equal-volume spheres. However, the highly polarizing nature of the particles over a broad wavelength-bandpass (Tomasko and Smith, 1982; West et al, 1983) combined with their forward-scattering behavior makes it very unlikely that the particles are spherical. The nonsphericity contributes to the uncertainty about the radii of the particles, but it is thought that the average radius is several tenths of a micron.

Rages, K.↗

Space optics; Proceedings of the Seminar, Huntsville, Ala., May 22-24, 1979

The seminar focused on infrared systems, the space telescope, new design for space astronomy, future earth resources systems, and planetary systems. Papers were presented on infrared astronomy satellite, infrared telescope on Spacelab 2, design alternatives for the Shuttle Infrared Telescope Facility, Spacelab 2 infrared telescope cryogenic system, geometrical theory of diffraction and telescope stray-light analysis, Space Telescope scientific instruments, faint-object spectrograph for the Space Telescope, light scattering from multilayer optics, bidirectional reflectance distribution function measurements of stray light suppression coatings for the Space Telescope, optical fabrication of a 60-in. mirror, interferogram analysis for space optics, nuclear-pumped lasers for space application, geophysical fluid flow experiment, coherent rays for optical astronomy in space, optical system with fiber-optical elements, and Pioneer-Venus solar flux radiometer.

Wyman, C. L.↗

Critical slowing of the spin and charge density wave order in thin film Cr following photoexcitation

We report on the evolution of the charge density wave (CDW) and spin density wave (SDW) orders of a chromium film following photoexcitation with an ultrafast optical laser pulse. The CDW is measured by ultrafast time-resolved x-ray diffraction of the CDW satellite that tracks the suppression and recovery of the CDW following photoexcitation. We find that as the temperature of the film approaches a discontinuous phase transition in the CDW and SDW orders, the time scales of recovery increase exponentially from the expected thermal time scales. We extend a Landau model for SDW systems to account for this critical slowing with the appropriate boundary conditions imposed by the geometry of the thin film system. This model allows us to assess the energy barrier between the available CDW/SDW states with different spatial periodicities.

36 MATERIALS SCIENCE↗

In-Situ Nanoscale Focusing of Extreme Ultraviolet Solid-State High Harmonics

Extreme ultraviolet light delivering radiation with a wavelength shorter than approximately 100 nm is now available from solid-state sources. However, despite exceptional progress, efficient focusing of extreme ultraviolet photons to their ultimate diffraction limit remains a formidable challenge because of the precision of the focusing by curved, optical surfaces. Here we integrate coherent short-wavelength high-order harmonics from a MgO crystal, with a high-numerical-aperture, nanostructured, focusing element etched onto the surface of the crystal itself. We focus extreme ultraviolet light, seventh harmonic of an 800-nm laser, with a zone plate of numerical aperture 0.35, down to a waist radius of 150 nm, with 18% focusing efficiency. The estimated intensity approaches 10 7 W/cm 2 . Future developments may demonstrate nanoscale laser ablation and miniaturization of extreme ultraviolet coherent sources on a chip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full complex amplitude control of second-harmonic generation via electrically tunable intersubband polaritonic metasurfaces

Nonlinear intersubband polaritonic metasurfaces based on coupling of the intersubband nonlinear optical response of quantum-engineered semiconductor heterostructures and electromagnetic modes of nanoresonators provide efficient frequency mixing with moderate pump intensities. The resonant nonlinear optical response, represented as a complex function, can be modulated via Stark tuning of intersubband transition energies under applied voltages. However, achieving full complex amplitude control (both phase and magnitude) remains challenging. In this work, we present and experimentally validate electrically tunable nonlinear intersubband polaritonic metasurfaces that achieve complete complex amplitude control for second-harmonic generation (SHG). Through a design featuring two in-plane flipped meta-atoms per unit cell, we achieve complete electrical control of both the amplitude and phase of the metasurface second-order nonlinear susceptibility, with a tuning range of 0 to 30 nm V −1 for the magnitude and 0-2π for the phase of the nonlinear optical response. Using these properties, we achieve complete on-off SHG modulation and beam diffraction tuning through electrically controlled amplitude and phase gratings.

Science & Technology - Other Topics↗

The Simons Observatory: modeling optical systematics in the Large Aperture Telescope

We present geometrical and physical optics simulation results for the Simons Observatory Large Aperture Telescope. This work was developed as part of the general design process for the telescope, allowing us to evaluate the impact of various design choices on performance metrics and potential systematic effects. The primary goal of the simulations was to evaluate the final design of the reflectors and the cold optics that are now being built. We describe nonsequential ray tracing used to inform the design of the cold optics, including absorbers internal to each optics tube. We discuss ray tracing simulations of the telescope structure that allow us to determine geometries that minimize detector loading and mitigate spurious near-field effects that have not been resolved by the internal baffling. We also describe physical optics simulations, performed over a range of frequencies and field locations, that produce estimates of monochromatic far-field beam patterns, which in turn are used to gauge general optical performance. Finally, we describe simulations that shed light on beam sidelobes from panel gap diffraction.

Gudmundsson, Jon E. (ORCID:0000000317600355)↗