Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

Cationic Effect of Ferrous Ions on Sulfide Capacity of CaO-Fe{sub t}O-Al{sub 2}O{sub 3}-SiO{sub 2} Slag System

The cationic effect of ferrous ions on the sulfide capacity of CaO-Fe{sub t}O-Al{sub 2}O{sub 3}-SiO{sub 2} slags was studied from the viewpoint of the ionic structure in the slag using micro-Raman spectroscopy. In the cation-excess region (M{sup 2+}/2(Fe{sup 3+} + Al{sup 3+}) > 1.0), the sulfide capacity was directly proportional to the basicity of the slags, owing to the S{sup 2−} stabilizing effect of excess cations. However, in the cation-deficient region (M{sup 2+}/2(Fe{sup 3+} + Al{sup 3+}) < 1.0), the sulfide capacity was independent of the basicity of the slags owing to the deficiency of cations required for charge compensation with Al{sup 3+} and Fe{sup 3+}. The cation-substitution effect on the sulfide capacity of the CaO-rich slags (Fe{sub t}O/(Fe{sub t}O + CaO < 0.5) exhibited a linear relationship with the Fe{sup 2+} content because Fe{sup 2+} had a stronger affinity with S{sup 2−} compared to that with Ca{sup 2+}. However, in the Fe{sub t}O-rich slags (Fe{sub t}O/(Fe{sub t}O + CaO > 0.5), the sulfide capacity decreased with the increase of the Fe{sup 2+} content owing to the Q{sup n} unit affinity of the Fe{sup 2+} ion. The sulfide capacity was determined by the competition between the Q{sup n} unit affinity and stability of the S{sup 2−} ion, depending on the type of cation. Therefore, the partial covalent bonding between the M{sup 2+} cations (M: Ca, Fe) and aluminosilicate affected the ionic interactions with the S{sup 2−} ions.

36 MATERIALS SCIENCE↗

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP↗

Insights Into Seismicity Associated With Flexibly Operating Enhanced Geothermal System From Real‐Time Distributed Acoustic Sensing

Enhanced Geothermal Systems (EGS) have the capacity to broaden the accessible resource pool for geothermal power generation. Traditionally viewed as a “baseload” resource, their flexible operation might also enable dispatchable load‐following generation and long‐term energy storage, aligning them with the evolving landscape of decarbonized electricity systems. However, increasing permeability and extracting energy during EGS operations can induce microseismic events; for many prior EGS efforts, some associated seismicity has been observed. While energetically beneficial, the flexibility of EGS operations prompts our inquiry into whether new types of operations will yield previously unseen seismicity patterns. We demonstrate the use of distributed acoustic sensing (DAS) with real‐time edge computing to monitor seismicity during a pilot test of a cyclically operated EGS facility at the Blue Mountain geothermal field. Our focus lies in uncovering seismicity insights from the real‐time microseismic catalog, particularly during load‐following dispatchability tests simulating flexible EGS operation. Here, we find that variations in pore pressure consistently correlate with seismicity, and that controlling pressure cycles during flexible operations appears to constrain microseismic activity during subsequent cycles. The spatio‐temporal evolution of microseismic clouds recorded during cyclic injection cycles fits diffusive models over our available observation period. Additionally, seismicity elevation lags behind pore pressure increases, likely due to pressure diffusion to the fracture system boundary. Through real‐time monitoring, we offer novel insights into seismicity associated with flexibly operating EGS. Our findings suggest that leveraging DAS and edge computing can inform EGS operations and help mitigate induced seismicity.

Chamarczuk, Michal [Rice Univ., Houston, TX (Unite↗

US computer research networks: Current and future

During the last decade, NASA LeRC's Communication Program has conducted a series of telecommunications forecasting studies to project trends and requirements and to identify critical telecommunications technologies that must be developed to meet future requirements. The Government Networks Division of Contel Federal Systems has assisted NASA in these studies, and the current study builds upon these earlier efforts. The current major thrust of the NASA Communications Program is aimed at developing the high risk, advanced, communications satellite and terminal technologies required to significantly increase the capacity of future communications systems. Also, major new technological, economic, and social-political events and trends are now shaping the communications industry of the future. Therefore, a re-examination of future telecommunications needs and requirements is necessary to enable NASA to make management decisions in its Communications Program and to ensure the proper technologies and systems are addressed. This study, through a series of Task Orders, is helping NASA define the likely communication service needs and requirements of the future and thereby ensuring that the most appropriate technology developments are pursued.

Kratochvil, D.↗

Utility-Scale Shared Energy Storage Deployment: Challenges, Research Gaps, and Opportunities

Although community energy storage (CES) and behind-the-meter (BTM) energy storage systems have been widely used to offer homeowners and communities a variety of localized benefits, their scalability and grid support functionalities are limited. On the other hand, utility-scale shared energy storage (USES) systems may offer a number of benefits for grid integration, scalability, and economic viability. When compared to BTM and CES alternatives, these large-scale systems provide more storage capacity, more efficient operations, and more economically viable options. The deployment of USES presents opportunities for optimizing grid performance, integrating renewable energy resources, and improving energy security at the community level. However, significant research gaps exist in optimizing the integration and operation of these systems, especially to allocate energy for consumer use, grid services, and enhancing energy resilience. This paper reviews the literature in this regard, focusing on the opportunities, research gaps, and challenges associated with USES deployment. Firstly, the paper provides an overview of USES systems and emphasizes their benefits. Secondly, the key challenges are identified, and research gaps associated with the operation and integration of these systems are highlighted. Lastly, some potential solutions and opportunities that can be adopted to facilitate the rapid deployment and management of USES are presented. Technological, economic, regulatory, and environmental aspects are also discussed in this paper, providing an overview of the current state and future prospects of this technology.

Gautam, Mukesh [BATTELLE (PACIFIC NW LAB)] (ORCID:↗

ChemComp: A Compilation Framework for Computing with Chemical Reaction Networks

The acceleration of scientific computation, data analytics, and artificial intelligence is driving a surge in computational requirements. Yet, state-of-the-art high-performance computing systems are approaching physical limitations that impede further significant improvements in energy efficiency. As we move towards post-exascale computing systems, innovative approaches are necessary to overcome this barrier in power consumption. Novel analog and hybrid digital-analog architectures hold promise for enhancing energy efficiency by several orders of magnitude. Biochemical computation stands out among the various solutions being explored due to its potential to enable new classes of devices with immense computational capabilities. These devices can capitalize on the inherent efficacy of biological cells in solving optimization problems and are scalable through increasing reaction system size or vessel capacity, potentially satisfying scientific computing's high-performance requirements. Nonetheless, several theoretical and practical limitations persist, including problem formulation and mapping to chemical reaction networks (CRNs) and implementation of actual CRN devices. In this paper, we propose a framework for biochemical computation using systems chemistry. We present the initial components of our approach: an abstract chemical reaction dialect implemented as a multi-level intermediate representation (MLIR) compiler extension and a pathway to represent mathematical problems with CRNs. To showcase the potential of this approach, we emulate a simplified chemical reservoir device. This work lays the groundwork for leveraging chemistry's computing potential in creating energy-efficient, high-performance computing systems tailored to contemporary computational needs.

artificial intelligence↗

Hybrid Energy Management with Real-Time Control of a High-Power EV Charging Site

Decarbonization of transportation systems is driving higher capacity energy storage and faster charging power requirements in electric vehicles (EVs). Given the potential advantages - such as increased efficiency, reduced inverter capacity, and less total cable mass - there is a demand in the industry for more DC distribution for high-power charging (HPC) hubs. However, the cost-effective, adaptive, and robust operation of the DC-coupled HPC hub necessitates a robust site energy management system (SEMS). Validating SEMS operation using a digital twin of an HPC hub in a real-time simulator (RTS) platform is crucial before field deployment. In this study, we propose a hybrid energy management site controller designed to achieve high-level, long-term operational objectives while managing low-level power sharing control between hub assets. We develop a centralized model predictive controller (MPC) to optimize hub operating points and use these points to update the droop parameters of the site energy storage system (ESS). This approach ensures the hub follows an optimal operating point while maintaining the flexibility to respond to load surges. We tested and verified our proposed approach both offline and on a Controller Hardware-in-the-loop (C-HIL) simulation platform integrated with a SEMS framework, demonstrating real-time site operation and validating a cost-effective and robust site controller.

ADVANCED PROPULSION SYSTEMS↗

Probabilistic Zonal Reserve Requirements for Improved Energy Deliverability with Wind Power

In power systems with high penetration of renewable energy resources, uncertainty and variability of these stochastic resources introduce additional challenges for the operation of power systems. To improve the power system's reliability in the face of uncertainty, reserves are required as additional generation capacity to rebalance the power system following random disturbances. However, reserve deliverability is not guaranteed, because it may encounter potential transmission line congestion. Zonal reserve requirements can address this issue, but operators lack efficient ways to allocate reserves to zones while accounting for wind power forecast uncertainty. Herein we propose a methodology for probabilistic zonal reserve requirements to address wind power forecast uncertainties. This method estimates the probability distribution of line flows based on the system generation margin and injection shift factor. This estimate is then used to construct pre-defined and post-zonal reserve requirements. Case studies demonstrate that the proposed method efficiently schedules energy and reserves to balance energy and manage deliverability with wind power forecast uncertainty.We also discuss operational implications of the proposed method.

17 WIND ENERGY↗

Wake Vortex Tracking Using a 35 GHz Pulsed Doppler Radar

A 35 GHz, pulsed-Doppler radar system has been designed and assembled for wake vortex detection and tracking in low visibility conditions. Aircraft wake vortices continue to be an important factor in determining safe following distances or spacings for aircraft in the terminal area. Currently, under instrument meteorological conditions (IMC), aircraft adhere to conservative, fixed following-distance guidelines based primarily on aircraft weight classifications. When ambient conditions are such that vortices will either drift or dissipate, leaving the flight corridor clear, the prescribed spacings are unnecessarily long and result in decreased airport throughput. There is a potential for significant airport efficiency improvement, if a system can be employed to aid regulators and pilots in setting safe and efficient following distances based on airport conditions. The National Aeronautics and Space Administration (NASA), the Federal Aviation Agency, and Volpe National Transportation Systems Center have promoted and worked to develop systems that would increase airport capacity and provide for safe reductions in aircraft separation. The NASA Aircraft Vortex Spacing System (AVOSS), a wake vortex spacing system that can provide dynamic adjustment of spacings based on real-time airport weather conditions, has demonstrated that Lidar systems can be successfully used to detect and track vortices in clear air conditions. To fill the need for detection capability in low-visibility conditions, a 35 GHz, pulsed-Doppler radar system is being investigated for use as a complimentary, low-visibility sensor for wake vortices. The radar sensor provides spatial and temporal information similar to that provided by Lidar, but under weather conditions that a Lidar cannot penetrate. Currently, we are analyzing the radar design based upon the data and experience gained during the wake vortex Lidar deployment with AVOSS at Dallas/Fort Worth International Airport. As part of this study, two numerical models were utilized in system simulations. The results of this study improve our understanding of the method of detection, resolution requirements for range and azimuth, pulse compression, and performance prediction. Simulations applying pulse compression techniques show that detection is good in heavy fog to greater than 2000 m. Both compressed and uncompressed short pulses show the vortex structure. To explore operational challenges, siting and scanning strategies were also analyzed. Simulation results indicate that excellent wake vortex detection, tracking and classification is possible in drizzle (+15 dBZ) and heavy fog (- 13 dBZ) using short pulse techniques (<99ns) at ranges on the order of 900 m, with a modest power of 500 W output. At 1600 m, detection can be expected at reflectivities as low as -13 dBZ (heavy fog). The radar system, as designed and built, has the potential to support field studies of a wake vortex spacing system in low-visibility conditions ranging from heavy fog to rain, when sited within 2000m of the flight path.

Neece, Robert T.↗

Future Roles of Milli-, Micro-, and Nano- Grids

Although it has slowed considerably, consumption of electricity continues to grow in developed economies. Further, there are some unknowns which might accelerate this growth, such as electrification of vehicle fleets and geothermal heat pump space and water heating. Most analysts anticipate that distributed energy resources (DER) will provide a large share of the expanded generation capacity required to meet this seemingly inexorably increasing electricity demand. Further, given the urgency of tackling the climate change problem, most of the added assets must be carbonfree renewables or nuclear, end-use efficiency improvements, or highly efficient fossil-fired technologies. In developed economies worldwide, the current power delivery paradigm has been in place for more than a century, i.e. since the emergence of polyphase AC systems around the turn of the last century. A key feature of this structure is that, in principle, universal service is delivered at a consistent level of power quality and reliability (PQR) throughout large regions. This paper describes a future possible structure for the electricity generation and delivery system that leaves the existing high voltage meshed grid paradigm in place, but involves radical reorganization of parts of the distribution network and customer sites. Managing a much more diverse dispersed system poses major challenges to the current centralized grid paradigm, particularly since many of these assets are small to tiny by macrogrid standards and they may ultimately number in the millions. They are also not ones that centralized control can rely upon to function in traditionally dependable ways, e.g. renewable generation can be highly variable and changes in output of generators are not independent. Although most involved in the industry agree that a paradigm shift is both necessary and desirable to manage the new system, the nature of the future system remains quite unclear. In the possible structure described here, the traditional grid, or macrogrid, remains similar at the high voltage meshed level. Three new entities are added more locally: community grids or milligrids that operate a segment of the existing distribution system, microgrids which are akin to current customer sites but which have automonous control, and nanogrids, such as telecom or Ethernet networks that currently distribute power to many low-power devices. The latter exist currently in the local electrical systems but are not typically considered a part of the traditional electricity supply system. Because all these new entities exhibit some localized control, providing appropriate local heterogeneous PQR becomes a possibility. These new grid concepts enable a more"bottom-up" approach to electricity distribution, in contrast to the historic 'top-down' model. The future will almost certainly include a mix of the two, but the balance among them and the interface (if any) between them is unclear.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of operating reserve demand curves in power system operations in the presence of variable generation

The electric power industry landscape is continually evolving. As emerging technologies such as wind and solar generating systems become more cost effective, traditional power system operating strategies will need to be re-evaluated. The presence of wind and solar generation (commonly referred to as variable generation or VG) can increase variability and uncertainty in the net-load profile. One mechanism to mitigate this issue is to schedule and dispatch additional operating reserves. These operating reserves aim to ensure that there is enough capacity online in the system to account for the increased variability and uncertainty occurring at finer temporal resolutions. A new operating reserve strategy, referred to as flexibility reserve, has been introduced in some regions. A similar implementation is explored in this study, and its implications on power system operations are analyzed. Results show that flexibility reserve products can improve economic metrics, particularly in significantly reducing the number of scarcity pricing events, with minimal impacts on reliability metrics and production costs. Furthermore, the production costs increased due to increased VG curtailment - i.e. including the flexible ramping product in the commitment of excess thermal capacity that needed to remain online at the expense of VG output.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Testing of Jefferson Lab 12 GeV Helium Screw Compressors

Oil injected screw compressors have essentially superseded all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, reliability, minimal vibration, and capability of handling helium's high heat of compression. At the present state of compressor system designs for helium refrigeration systems, typically two-thirds of the lost input power is due to the compression system. It is important to understand the isothermal and volumetric efficiencies of these machines to help properly design the compression system to match the refrigeration process. It is also important to identify those primary compressor skid exergetic loss mechanisms which may be reduced, thereby offering the possibility of significantly reducing the input power to helium refrigeration processes which are extremely energy intensive. This paper summarizes the results collected during the commissioning of the new compressor system for Jefferson Lab?s (JLab?s) 12 GeV upgrade. The compressor skid packages were designed by JLab and built to print by industry. They incorporate a number of modifications not typical of helium screw compressor packages and most importantly allow a very wide range of operation so that JLab?s patented Floating Pressure Process can be fully utilized. This paper also summarizes key features of the skid design that allow this process and facilitate the maintenance and reliability of these helium compressor systems.

Knudsen, P.↗

Lower limb kinematics during treadmill walking after space flight: implications for gaze stabilization

We examined the lower limb joint kinematics observed during pre- and postflight treadmill walking performed by seven subjects from three Space Shuttle flights flown between March 1992 and February 1994. Basic temporal characteristics of the gait patterns, such as stride time and duty cycle, showed no significant changes after flight. Evaluation of phaseplane variability across the gait cycle suggests that postflight treadmill walking is more variable than preflight, but the response throughout the course of a cycle is joint dependent and, furthermore, the changes are subject dependent. However, analysis of the phaseplane variability at the specific locomotor events of heel strike and toe off indicated statistically significant postflight increases in knee variability at the moment of heel strike and significantly higher postflight hip joint variability at the moment of toe off. Nevertheless, the observation of component-specific variability was not sufficient to cause a change in the overall lower limb joint system stability, since there was no significant change in an index used to evaluate this at both toe off and heel strike. The implications of the observed lower limb kinematics for head and gaze control during locomotion are discussed in light of a hypothesized change in the energy attenuation capacity of the musculoskeletal system in adapting to weightlessness.

NASA Discipline Number 16-10↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Commissioning the cryogenic system of the first LHC sector

The LHC machine, composed of eight sectors with superconducting magnets and accelerating cavities, requires a complex cryogenic system providing high cooling capacities (18 kW equivalent at 4.5 K and 2.4 W at 1.8 K per sector produced in large cold boxes and distributed via 3.3-km cryogenic transfer lines). After individual reception tests of the cryogenic subsystems (cryogen storages, refrigerators, cryogenic transfer lines and distribution boxes) performed since 2000, the commissioning of the cryogenic system of the first LHC sector has been under way since November 2006. After a brief introduction to the LHC cryogenic system and its specificities, the commissioning is reported detailing the preparation phase (pressure and leak tests, circuit conditioning and flushing), the cool-down sequences including the handling of cryogenic fluids, the magnet powering phase and finally the warm-up. Preliminary conclusions on the commissioning of the first LHC sector will be drawn with the review of the critical points already solved or still pending. The last part of the paper reports on the first operational experience of the LHC cryogenic system in the perspective of the commissioning of the remaining LHC sectors and the beam injection test.

43 PARTICLE ACCELERATORS↗

An Efficient Power Flexibility Aggregation Framework via Coordinate Transformation and Chebyshev Centering Optimization

The large-scale integration of distributed energy resources (DERs) converts the role of a distribution system from a customer to a prosumer. In this context, the controllable DERs are expected to provide capacity support for the transmission system, which can be considered as power flexibility aggregation. Specifically, it is a process of controlling the power output of DERs to fulfill the desired capacity or flexibility. However, the power output of DERs as control variables is redundant. That is, a power flexibility command can be realized by multiple dispatch alternatives, which may hinder efficient design of control rules and flexibility evaluation schemes. Therefore, this paper introduces a conception of the artificial power flexibility controller to avoid the redundancy issue, which is a converted control variable after reconstructing the DER power region. Through this reconstruction, the DERs can be indirectly controlled by the proposed artificial power flexibility controller. In addition, a Chebyshev centering optimization model is developed to approximate the power flexibility region. At last, the proposed method is verified on an artificially-designed network with multiple DERs.

Chebyshev centering optimization↗