Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “station”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Progress on the Proton Power Upgrade Project at the Spallation Neutron Source

The Proton Power Upgrade Project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion of the project, 2 MW of beam power will be available for neutron production at the existing first target station with the remaining beam power available for the future second target station. The project will install seven superconducting RF cryomodules and supporting RF power systems and ancillaries to increase the beam energy to 1.3 GeV . The injection and extraction region of the accumulator ring will be upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. Equipment is being received from vendors and partner laboratories, and installation is underway with three major installation outages planned in 2022-2024. The project is planned to be completed in 2025.

43 PARTICLE ACCELERATORS↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Proposal for a Fusion Prototype Neutron Source at the Los Alamos Neutron Science Center

This study evaluates a target station at the Los Alamos Neutron Science Center dedicated to the mission of irradiating structural materials in an environment that is nearly prototypic of the radiation environment experienced by the first wall of a magnetically-confined fusion reactor burning D-T fuel. Such a station could be located in the existing Area A experimental hall and be driven by an 800-MeV, 1-MW proton beam delivered by the LANSCE accelerator. A neutronics assessment of a target concept shows it satisfies all of the key parameter guidelines stated in the Summary Report on the Fusion Prototypic Neutron Source Workshop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Assessment of the Potential for Utility-Scale Solar Energy Development on the Navajo Nation

The Navajo Nation covers about 27,000 square miles in the Southwestern United States with approximately 270 sunny days a year. Therefore, the Navajo Nation has the potential to develop utility-scale solar photovoltaic (PV) energy for the Navajo people and export electricity to major cities to generate revenues. In April 2019, the Navajo Nation issued a proclamation to increase residential and utility-scale renewable energy development on the Navajo Nation. In response, this research assesses the potential for utility-scale solar energy development on the Navajo Nation using criteria such as access to roads, transmission lines, slope/terrain data, aspect/direction, and culturally sensitive sites. These datasets are applied as layers using ArcGIS to identify regions that have good potential for utility-scale solar PV installations. Land availability on the Navajo Nation has been an issue for developing utility-scale solar PV, so this study proposes potential locations for solar PV and how much energy these potential sites could generate. Furthermore, two coal-fired power plants, the Navajo Generating Station and the San Juan Generating Station, will close soon and impact the Navajo Nation's energy supply and economy. This study seeks to answer two main questions: whether utility- scale solar energy could be used to replace the energy generated by both coal-fired powerplants, and what percentage of the Navajo Nation's energy demands can be met by utility-scale solar energy development? Economic development is a major concern; therefore, this study also examines what utility-scale solar development will mean for the Navajo Nation economy. The results of this study show that the Navajo Nation has a potential PV capacity of 45,729 MW to 91,459 MW. Even with the lowest calculated capacity, utility-scale solar PV has the potential to generate more than 11 times the power of the NGS and SJGS combined.

14 SOLAR ENERGY↗

Requirements Document for a Replacement Data Acquisition System

A flight vehicle is in the developmental stages. While in development flight testing is required by both the manufacturer and customer to rate design performance. The performance of the vehicle must fulfill the agreed upon requirements. Testing of a flight vehicle during operation requires various sensors in order to record and monitor performance for evaluation. A Data Acquisition System (DAQ) is needed in order to control and capture data from various sensors placed throughout the vehicle during flight. This DAQ will receive the analog data from the suite of sensors and convert them to a digital signal that can be transmitted to a recording station where the data will later be analyzed by test experts. Some of the key features to be included in the DAQ will be a self-check operation to verify the health of all sensors including the DAQ. The DAQ will also have the capability to store sensor calibration data files loaded during assembly and transmit those files to the recording station during flight. Breakthroughs in new technologies has allowed for higher resolution recording systems and faster sampling rates. Improved sensor data using a new Data Acquisition System (DAQ) can provide important answers to questions discovered during the last few flight tests. These questions arose when the flight system expressed unexpected behaviors. Having the capability of the new DAQ in flight tests would allow for more high-fidelity data to be captured from the system during flight tests and ultimately reducing the number of required flight test. Reducing the number of flight tests also reduce developmental cost and schedule.

42 ENGINEERING↗

QUIC-Fire: 3D Fire-Atmosphere Feedback Model for Wildland Fire Management

Los Alamos National Laboratory, U.S. Forest Service, and Tall Timbers Research Station developed QUIC-Fire, the first laptop-capable, real-time wildland fire prediction software that captures the critical influences of 3D vegetation structure, interactions between multiple fires, variable winds, and complex topography at meter-scale resolutions. Prescribed burns are needed to prevent catastrophic wildfires in the U.S. QUIC-Fire transforms a prescribed fire manager’s ability to assess risk, optimize fuel treatments, and plan prescribed burns. Los Alamos, U.S. Forest Service, Tall Timbers Research Station, U.S. Fish and Wildlife Service, Spatial Information Group, and Applied Interagency Prescribed Training Center have used QUIC-Fire.

54 ENVIRONMENTAL SCIENCES↗

Triangulations using Phototheodolites

A year before a nuclear test was performed, EG&G would develop a photo plan in which a bomb’s intended point of detonation and all camera positions would be specified. During some of the earlier Operations at the Nevada Test Site, a large number of the nuclear tests were airdrops. Anticipating that the Air Force might miss the intended ground zeros (GZs), EG&G would setup phototheodolites stations at two or more locations that were ~90 degrees apart. The cameras at these stations were special cameras (referred to as phototheodolites or cinetheodolites) that were aimed at the intended ground zero. The cameras were triggered shortly after the detonation in order to capture the fireball at a very early stage. These photographs were then analyzed using a triangulation method to determine the bomb’s actual location and its height of burst (HOB).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-Instance learning Framework for Seismic Detectors

In this report, we construct and test a framework for fusing the predictions of a ensemble of seismic wave detectors. The framework is drawn from multi-instance learning and is meant to improve the predictive skill of the ensemble beyond that of the individual detectors. We show how the framework allows the use of multiple features derived from the seismogram to detect seismic wave arrivals, as well as how it allows only the most informative features to be retained in the ensemble. The computational cost of the "ensembling" method is linear in the size of the ensemble, allowing a scalable method for monitoring multiple features/transformations of a seismogram. The framework is tested on teleseismic and regional p-wave arrivals at the IMS (International Monitoring System) station in Warramunga, NT, Australia and the PNSU station in University of Utah's monitoring network.

58 GEOSCIENCES↗

Vendor-Independent Design Requirements for a Boiling Water Reactor Safety System Upgrade

This Vendor-Independent License Amendment Request (LAR) Framework Document is a research product developed for the Idaho National Laboratory Light Water Reactor Sustainability (LWRS) Program. It was developed by MPR Associates, Inc. with technical input from LWRS and Exelon Generation personnel. To accomplish the purpose of this research, an operating plant (Limerick Generating Station [LGS]) was used as a reference to provide a concrete example and to present a "top-down" view of design concepts consistent with functional requirements baseline documents (references X and Y) also developed for this research. While this document is written in a framework to support a complete LAR submittal, its purpose is to communicate research concepts and provide an example of how to present digital information necessary to address expectations with regard to leveraging the Alternate Review Process as provided in Digital Instrumentation and Controls Interim Staff Guidance #06, Revision 2, Licensing Process. To leverage that process, this research document presupposes that a utility would select a vendor platform which has been prequalified for safety-related by the United States Nuclear Regulatory Commission. While this document is written using the Exelon Generation Limerick Generating Station (LGS) Units 1 and 2 as a baseline, this document is a research product. This document contains no commitments and makes no binding design decisions for Exelon Generation. Exelon Generation is leveraging this research to support their in-progress LGS Plant Protection System (PPS) upgrade efforts and plans to leverage it for their Redundant Reactor Control System (RRCS) replacement. The LWRS Program appreciates the research support provided by Exelon Generation in the generation of this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MELCOR 2.2 Benchmarks of Peach Bottom NUREG/CR 7155 Uncertainty Analysis

The U.S. Nuclear Regulatory Commission (NRC) performed a first-of-a-kind uncertainty analysis (UA) of the accident progression, radiological releases, and offsite consequences for the State-of- the-Art Reactor Consequence Analyses (SOARCA) of an unmitigated long-term station blackout (LTSBO) severe accident scenario at the Peach Bottom Atomic Power Station. The objective of the UA was to evaluate the robustness of the SOARCA deterministic "best estimate results and conclusions documented in NUREG-1935, and to develop insight into the overall sensitivity of the SOARCA results to uncertainty in key modeling inputs. The study was completed in 2015 and documented in NUREG/CR-7155. Since 2015, two other SOARCA UAs were completed for two pressurized water reactor (PWR) plants. The PWR UAs incrementally updated the approach and methodology, including using the latest release of the MELCOR 2.2 computer code. There were also advances made in the state-of-the-art modeling related to NRC efforts using the Peach Bottom model in NUREG-2206, which provided the technical basis for the containment protection and release reduction rulemaking for boiling water reactors with Mark I and Mark II containments. This report documents the input model changes from the NUREG/CR-7155 study and performs a small number of reference calculations to assess the changes of the new computer code and the model input updates. The objective of the work is to verify whether the updated Peach Bottom MELCOR model and updated version of MELCOR support the conclusions formed in the Peach Bottom SOARCA UA by performing these representative calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

Sitewide Environmental Impact Statement Site 300 and Arroyo Mocho Lawrence Livermore National Laboratory Alameda and San Joaquin Counties, California (Mid-Term Report)

At the request of Lawrence Livermore National Security (LLNS), Nomad Ecology (Nomad) conducted sensitive botanical resource surveys, and vegetation mapping and classification of the 7,000-acre Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) and 17 acres surrounding the Arroyo Mocho pumping station and the access road to the pumping station (Arroyo Mocho). In addition to surveying for sensitive botanical resources, Nomad also compiled existing rare plant and vegetation data provided by LLNL from past monitoring and environmental impact evaluations. The results of these efforts will provide supporting information for a Site-wide Environmental Impact Statement (SWEIS). These surveys were conducted during the months of April – June, and August 2020. Rare plant surveys were scheduled for February and March 2020; however, February surveys were not initiated because the contract for this work was not finalized, and March surveys were cut short due to the timing of the Covid-19 shelter in place. February and March rare plant surveys are scheduled for 2021; therefore, the rare plant survey results in this report should be considered incomplete until the 2021 surveys are conducted. A total of 10 special status plant species were recorded within Site 300 and Arroyo Mocho. Of these 10, three were not previously recorded within the study areas, and include Hospital Canyon larkspur (Delphinium californicum subsp. interius), Jepson’s woolly sunflower (Eriophyllum jepsonii), and Michael’s rein orchid (Piperia michaelii), which all occur at Arroyo Mocho. Special status plant species known from these two sites total 23 rare plant occurrences (populations), which represent an estimated 50,929 rare plant individuals. This total of all special status plant species breaks down to one occurrence of a federally and/or state listed plant species (98 individuals), six occurrences of California Rare Plant Rank (CRPR) 1 & 2 species (49,010 individuals), and 16 occurrences of CRPR 3 & 4 species (1,821 individuals). A total of 35 vegetation communities were mapped at Site 300, of which 20 are considered Sensitive Natural Communities. A total of nine vegetation communities were mapped at Arroyo Mocho, of which two are considered Sensitive Natural Communities.

54 ENVIRONMENTAL SCIENCES↗

Guidelines for Broadband Seismometer Testing

The Comprehensive Nuclear-Test-Ban Treaty mandates the four verification technologies to be used by the International Monitoring System (IMS) to monitor compliance to the Treaty. These technologies are seismic, hydroacoustic, infrasound, and radionuclide. Operational manuals for each of these technologies specify the requirements that equipment installed at IMS stations must meet for data from said stations to be accepted by the International Data Center. Following a model in which a revised set of infrasound sensor specifications and accompanying test procedures were developed in an international collaboration overseen by the Comprehensive Nuclear-Test-Ban Treaty Organization, the same process was recently followed for seismometers potentially of use by the IMS. This document, a product of that collaboration, defines key concepts and recommends test procedures to be followed to characterize broadband seismometers in a consistent and standardized way. Results from these test procedures can be used to verify that a seismometer meets the manufacturers stated specifications and IMS requirements. ACKNOWLEDGEMENTS The writers of this document would like to acknowledge Charles R. Hutt, John R. Evans, Fred Followill, Robert L. Nigbor, and Erhard Wielandt, the authors of the 2009 Guidelines for Standardized Testing of Broadband Seismometers and Accelerometers funded by the U.S. Department of Interior, on which this document is based. Although this document is limited in scope to seismometers and much of the document has been updated, the structure remains essentially the same.

58 GEOSCIENCES↗

Validation of the High-Resolution Salish Sea Tidal Hydrodynamic Model

In this study, a tidal hydrodynamic model was developed and validated to simulate tidal currents in Puget Sound, Washington, to support tidal energy resource characterization using the unstructured-grid, Finite Volume Community Ocean Model (FVCOM). The Salish Sea tidal hydrodynamic model was driven by tides along two open boundaries at the entrance of the Strait of Juan de Fuca and north end of Georgia Strait, and river flows from 19 major rivers in the Salish Sea. To simulate the tidal current in Puget Sound, a high-resolution model grid is required to accurately represent the complex coastlines and bathymetry. The spatial resolution of the model grid varies from ~10 m near river boundaries and ~30 m in small tidal channels and estuaries to near 1000 m inside Georgia Strait and at the open boundaries. Model validation was carried out by comparing simulated and observed water levels at 12 tidal stations and currents at 135 Acoustic Doppler Current Profiler stations in the model domain. A set of model performance metrics, including root mean square error, scatter index, bias, and linear correlation coefficient, were used to quantify the model skills in simulating the tidal hydrodynamics in Puget Sound. Error statistics showed an overall good agreement between simulated and observed tidal elevations and currents, which demonstrated that the Puget Sound tidal model can be used to accurately characterize the tidal stream energy resource in Puget Sound.

16 TIDAL AND WAVE POWER↗