Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficiencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Life-Cycle Cost Analysis Framework for Water Efficiency Measures

Life-Cycle Cost Analysis Framework for Water Efficiency Measures: Guidance Designed for Federal Agencies (hereafter referred to as “this report”) provides a technical framework for federal agencies to conduct a life-cycle cost analysis (LCCA) for water efficiency projects in accordance with 42 U.S.C. § 8253. This report leverages insights from the 2023 report, PNNL-34006, Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition (Unger et al. 2023). The primary objective of this report is to provide a framework to assist federal agencies with evaluating the full economic impact of water efficiency projects by assessing both initial investments and long-term operational benefits. An LCCA can provide a comprehensive view of all costs associated with a water efficiency project, including initial investment, ongoing operations and maintenance (O&M), and eventual disposal or replacement, ensuring the most cost-effective solution is selected. The LCCA methodology outlined in this report enables users to compare base case scenarios with potential alternatives using a standardized present value approach. It incorporates key cost components such as energy, water and wastewater, installation, O&M, and equipment replacement. Additionally, the framework introduces relevant evaluation metrics, such as the net savings and the savings-to-investment ratio, to ensure that water efficiency measures are economically justified over the lifespan of the project. To support practical application, this report also describes various water efficiency strategies that may be analyzed using an LCCA, including plumbing retrofits, irrigation upgrades, alternative water use, and cooling system improvements. By applying this framework, federal agencies can ensure compliance with regulatory mandates while maximizing the return on investment and contributing to resilient water management practices. The information provided in this report is aligned with the Federal Energy Management Program (FEMP) life-cycle cost (LCC) methodology, as conveyed in National Institute of Standards and Technology (NIST) Handbook 135 (Kneifel and Webb 2022). This report is intended to provide relatively high-level guidance, acting as a complement to, rather than a substitute for, that resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Development Path to the Efficient and Cost-Effective Bulk Storage of Electrical Energy

Efficient and cost-effective means for storing electrical energy is becoming an increasing need in our electricity-oriented society. For example, for electric utilities an emerging need is for distributed storage systems, that is, energy storage at substations, at solar or wind-power sites, or for load-leveling at the site of major consumers of their electricity. One of the important consequences of distributed storage for the utilities would be the reduction in transmission losses that would result from having a local source of load-leveling power. For applications such as these there are three criteria that must be satisfied by any new system that is developed to meet such needs. These criteria are: (1) high 'turn-around' efficiency, that is, high efficiency of both storing and recovering the stored energy in electrical form, (2) long service life (tens of years), with low maintenance requirements, and, (3) acceptably low capital cost. An additional requirement for these particular applications is that the system should have low enough standby losses to permit operation on a diurnal cycle, that is, storing the energy during a portion of a given day (say during sunlight hours) followed several hours later by its use during night-time hours. One answer to the spectrum of energy storage needs just outlined is the 'electromechanical battery'. The E-M battery, under development for several years at the Laboratory and elsewhere in the world, has the potential to solve the above energy storage problems in a manner superior to the electro-chemical battery in the important attributes of energy recovery efficiency, cycle lifetime, and amortized capital cost. An electromechanical battery is an energy storage module consisting of a high-speed rotor, fabricated from fiber composite, and having an integrally mounted generator/motor. The rotor operates at high speed, in vacuo, inside of a hermetically sealed enclosure, supported by a 'magnetic bearing', that is, a bearing that uses magnetic forces to support the rotor against gravity. Magnetic bearings are a virtual necessity for the E-M battery in order to achieve long service life, and to minimize frictional losses so that the battery does not lose its charge (run down) too rapidly. These considerations mitigate against the use of conventional mechanical bearings in the E-M battery for most applications. The Laboratory has pioneered the development of a new form of magnetic bearing to meet the special requirements of the E-M battery: the 'ambient-temperature passive magnetic bearing'. Simpler, and potentially much less expensive than the existing 'active' magnetic bearings (ones requiring electronic amplifiers and feedback circuits for their operation) development of the ambient-temperature passive magnetic bearing represents a technological breakthrough. Beyond its use in the E-M battery, the ambient-temperature magnetic bearing could have important applications in replacing conventional lubricated mechanical bearings in electrical machinery. Here the gains would be two-fold: reduced frictional losses, leading to higher motor efficiency, and, of equal importance, the elimination of the need for lubricants and for routine replacement of the bearings owing to mechanical wear. Thus an added benefit from a vigorous pursuit of our electromechanical battery concepts could be its impact on many other areas of industry where rotating machinery in need of improved bearings is involved. If perfected, passive magnetic bearings would seem to represent an almost ideal replacement for the mechanical bearings in many types of industrial electrical machinery. Returning to the issued of energy storage, the E-M battery itself has much to contribute in the area of improving the efficiency of stationary energy storage systems. For example, many electrical utilities utilize 'pumped hydro' energy storage systems as a means of improving the utilization of their 'base-load' power plants. That is, electrical energy is stored during off-peak hours for delivery at times of peak usage. These pumped hydro systems employ upper and lower reservoirs, between which water is shuttled to store and recover the energy. Of necessity, pumped hydro storage facilities are located in mountainous areas, usually far, both from the urban centers where power uses are concentrated, and from the sites of the power plants themselves, increasing the transmission line losses that subtract from the useful energy. More importantly, pumped hydro systems themselves only return from 65 to 70 percent of the electrical energy input required to pump the water from the lower reservoir to the upper one. Thus, including the extra transmission losses from distant siting of the facility, of order 40 percent of the input electrical energy is wasted in every cycle of use of the facility.

25 ENERGY STORAGE↗

Energy-Efficiency Improvement Opportunities for the Textile Industry

The textile industry is one of the most complicated manufacturing industries because it is a fragmented and heterogeneous sector dominated by small and medium enterprises (SMEs). Energy is one of the main cost factors in the textile industry. Especially in times of high energy price volatility, improving energy efficiency should be a primary concern for textile plants. There are various energy-efficiency opportunities that exist in every textile plant, many of which are cost-effective. However, even cost-effective options often are not implemented in textile plants mostly because of limited information on how to implement energy-efficiency measures, especially given the fact that a majority of textile plants are categorized as SMEs and hence they have limited resources to acquire this information. Know-how on energy-efficiency technologies and practices should, therefore, be prepared and disseminated to textile plants. This guidebook provides information on energy-efficiency technologies and measures applicable to the textile industry. The guidebook includes case studies from textile plants around the world and includes energy savings and cost information when available. First, the guidebook gives a brief overview of the textile industry around the world, with an explanation of major textile processes. An analysis of the type and the share of energy used in different textile processes is also included in the guidebook. Subsequently, energy-efficiency improvement opportunities available within some of the major textile sub-sectors are given with a brief explanation of each measure. The conclusion includes a short section dedicated to highlighting a few emerging technologies in the textile industry as well as the potential for the use of renewable energy in the textile industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency as a Foundational Technology Pillar for Industrial Decarbonization

The U.S. government aims to achieve net-zero greenhouse gas emissions by 2050 to reduce the severe impacts of climate change. The U.S. industrial sector will become a focal point for decarbonization since it accounts for 33% of the nation’s primary energy use and 30% of its energy-related CO2 emissions. Industrial emissions are also expected to increase by 15% through 2050, making the industrial sector a logical target for decarbonization efforts. Energy efficiency technology pathways provide low-cost, foundational routes to decarbonization that can be implemented immediately. Energy efficiency technology pathways, such as strategic energy management, system efficiency, smart manufacturing, material efficiency, and combined heat and power, are well established and would immediately reduce energy use and emissions. However, their role in the aggressive net-zero decarbonization pathway for the industrial sector is still unclear. This study aims to address energy efficiency pathways for decarbonization, and reviews studies related to these technologies for industrial decarbonization through 2050. This study identifies different strategies for the industrial sector in general and that are specific to six energy-intensive industries: iron and steel; chemical; food and beverage; petroleum refining; pulp and paper; and cement. Finally, a path toward the successful implementation of energy efficiency technologies is outlined.

Strategic energy management↗

Decomposing Fuel Economy and Greenhouse Gas Regulatory Standards in the Energy Conversion Efficiency and Tractive Energy Domain

The three foundational elements that determine mobile source energy use and tailpipe carbon dioxide (CO2) emissions are the tractive energy requirements of the vehicle, the on-cycle energy conversion efficiency of the propulsion system, and the energy source. The tractive energy requirements are determined by the vehicle's mass, aerodynamic drag, tire rolling resistance, and parasitic drag. Oncycle energy conversion of the propulsion system is dictated by the tractive efficiency, non-tractive energy use, kinetic energy recovery, and parasitic losses. The energy source determines the mobile source CO2 emissions. For current vehicles, tractive energy requirements and overall energy conversion efficiency are readily available from the decomposition of test data. For future applications, plausible levels of mass reduction, aerodynamic drag improvements, and tire rolling resistance can be transposed into the tractive energy domain. Similarly, by combining thermodynamic, mechanical efficiency, and kinetic energy recovery fundamentals with logical proxies, achievable levels of energy conversion efficiency can be established to allow for the evaluation of future powertrain requirements. Combining the plausible levels of tractive energy and on-cycle efficiency provides a means to compute sustainable vehicle and propulsion system scenarios that can achieve future regulations. Using these principles, the regulations established in the United States (U.S.) for fuel consumption and CO2 emissions are evaluated. Fleet-level scenarios are generated and compared to the technology deployment assumptions made during rule-making. When compared to the rule-making assumptions, the results indicate that a greater level of advanced vehicle and propulsion system technology deployment will be required to achieve the model year 2025 U.S. standards for fuel economy and CO2 emissions.

CAFE↗

Improving Computational Efficiency of Prognostics Algorithms in Resource-Constrained Settings

In engineering and aerospace applications, it is vital to operational success to have insight into the expected performance and health of physical systems. The field of prognostics and health management provides quantitative methods for monitoring, predicting, and managing system health. Prognostics algorithms can be employed to assess the current state of a system, propagate the system throughout time, and predict potential anomalies or failures that may occur. While they can provide accurate prediction results, effective prognostics algorithms can be challenging to use in resource-constrained settings due to computational limitations and high computational latency, leading to obsolete predictions. Thus, computationally efficient and accurate algorithms are necessary for future remaining useful life predictions. In this work, we implement new algorithmic approaches for prediction, quantitatively compare them via a battery degradation use-case, and provide recommendations of potential improvements to a prognostics framework. One approach to prediction is through sampling, whereby the current state of a physical system is sampled many times and each sample is propagated forward until failure is reached, resulting in a distribution of failure values. To improve the efficiency of this process, we implemented five new algorithmic approaches to prediction, including three distinct sampling methods (standard Monte Carlo, Quasi-Monte Carlo, and Latin Hypercube Sampling), a variable time step algorithm, and a variable sample size algorithm. To compare the algorithms, we employ a variety of metrics designed specifically to analyze both computational efficiency and model accuracy. Our metrics include accuracy to compare the average predicted value to ground truth, mean absolute deviation to illustrate dispersion, specific percentile error to describe accuracy within a user-defined risk tolerance, and code run-time. To quantitatively analyze our results, we employ a use-case of degradation of a Lithium-ion battery. We use an electrochemistry-based model to describe the current health state of the battery, and implement our prediction algorithms to propagate forward in time until end-of-discharge (EOD) is reached. Notably, through this work it was found that none of our sampling approaches had a significant impact on computational efficiency or model accuracy in predicting EOD of the battery. We find that while the sampling methods are unique, the distributions they generate are similar, ultimately producing final predictions that are nearly identical. In exploring the effect of the time step within the prediction algorithm, we found that prediction accuracy was highly dependent on the time step used, and that implementing a variable time step within a particular prediction may provide an increase in computational efficiency while also maintaining prediction accuracy. Finally, implementing a variable sample size also affected prediction, and our results show that tuning both the magnitude and timing of the sample size adjustment can result in improved computation speed and maintained prediction accuracy. Taken together, our findings highlight the challenge of performing prognostics in resource-constrained settings, and illustrate the potential of developing new prediction algorithms to improve computational efficiency.

prognostics↗

Specific Power and Efficiency Projections of Electric Machines and Circuit Protection Exploration for Aircraft Applications

The purpose of this paper is to generate specific power and efficiency projections through the year 2050 for electric machines for aircraft applications. A general literature review was performed to identify the types of electric machines that are commonly used and which types have the biggest potential for future aircraft applications due to their high specific power and efficiency. A database with historical data was built to include parameters such as weight [kg], rated power [kW], specific power [kW/kg], RPM, efficiency, year, motor cooling type, application type and motor type to allow for trend identification and accurate projections. Once the data was gathered, multiple curve fits on the historical data were generated and extrapolated to produce the projections for specific power according to conservative, nominal and aggressive projection scenarios. A different process was followed for the efficiency projections due to the scattered nature of the data. A state of the art (SoA) value for efficiency was identified through literature review and was used to create the conservative, nominal and aggressive projections for the time frames of 2030, 2040, and 2050. The efficiency and the specific power projections of EMs for 2050 are 0.989 and 50kW/kg respectively. This paper will also be examining circuit protection as it is an additional component of electric powertrains.

electric machines↗

The Benefits of Creating a Cross-Country Data Framework for Energy Efficiency

As manufacturers now sell a similar range of consumer electronics and home appliances to major markets around the world, the task of identifying a product?s energy efficiency rating has usually been the responsibility of each country and its respective government agency. This has led to a multitude of energy efficiency testing procedures, ratings, and certifications, resulting in disparate data being captured on identical products. Furthermore, lack of consistent product identification criteria means product energy performance is not easily connected to relevant information about the product such as market availability, price or real world energy consumption. This paper presents a new data standard for reporting energy performance and related product information that can be adopted internationally. To inform the development of this standard, we explore the existing energy efficiency market data for the two example products of TVs and Room Air Conditioners. This paper discusses current/future use cases of appliance level energy efficiency data across all stakeholders, including consumers, retailers/manufacturers, global standards organizations, third party service providers, and regulatory agencies. It also explains the key benefits of moving to a common international data framework for energy efficiency, such as: 1) a centralized product information repository for comparing energy use, ratings/certifications, and pricing data 2) improved access to relevant consumer electronics and appliance data to facilitate new policy development and harmonization across markets 3) enablement of retailers and other third parties to embed actionable energy efficiency information as part of the consumer experience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Efficiency in Small Server Rooms: Field Surveys and Findings

Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Lived Modules Need to be Efficient, Lightweight, and Circular for the Energy Transition

Deployment projections for decarbonizing the grid predict 1.75 TW of PV is needed in the United States by 2050. This entails a cumulative demand of 97 million metric tonnes of virgin materials for c-Si modules. These material needs are extraction and energy intensive, making them a key target for improving PV sustainability. Emerging PV technologies, such as perovskites, are targeting 15-year modules, high efficiencies, and circular designs. Previous analysis found that by just modifying the life expectancy to 15 years (keeping target c-Si efficiencies and BOM), an additional 1.4 TW of replacement modules are required to maintain capacity, increasing virgin material demand by 1.75x unless >95% closed-loop recycling is maintained. This study examines the effect of achieving higher efficiencies with thin-film designs and a 15-year expectancy. Higher efficiencies and thin film designs can decrease deployment and material demands, making the level of circularity more attainable. If BOM mass is reduced by 50%, closed-loop recycling rates need to be >80% to reduce virgin material demands compared to a 35-yr c-Si module. If module efficiencies are 30%, closed-loop recycling rates can be reduced to 65%. This efficiency increase also reflects that 1500 million fewer modules can be deployed, however, this is still 2000 million more modules than a 35-year module needs to deploy to achieve energy transition targets, and no PV technology is closed-loop recycled for all component materials.

circular economy↗

Triple-Junction III-V Solar Cells with 39.5% AM1.5G and 34.2% AM0 Efficiencies

III-V multijunction solar cells have the highest efficiencies of any PV technology. These devices are currently the dominant space PV technology, and are being investigated for a wide range of other applications where efficiency is a key metric. In this presentation, we describe a 3-junction cell with the highest 1-sun efficiency to date: 39.5% under the global spectrum, which is higher than previous 6-junction devices. When tuned for the space spectrum, the cell achieves 34.2% beginning-of-life efficiency, without consideration for radiation hardness. These efficiency improvements are enabled by combining advances in device architectures and extended-defect control strategies. This latest 3-junction device includes a high-performance front-junction GaInP top cell, an optically-thick strain-balanced quantum well middle cell, and a lattice-mismatched GaInAs bottom cell with record performance despite dislocations. These advances not only allow high efficiency photovoltaics for both space and terrestrial PV applications, but also help enable new applications of III-V materials.

GaInAs↗

Benefits of creating a cross-country data framework for energy efficiency

As manufacturers now sell a similar range of consumer electronics and home appliances to major markets around the world, the task of identifying a product’s energy efficiency rating has usually been the responsibility of each country and its respective government agency. This has led to a multitude of energy efficiency testing procedures, ratings, and certifications, resulting in disparate data being captured on identical products. Furthermore, lack of consistent product identification criteria means product energy performance is not easily connected to relevant information about the product such as market availability, price or real world energy consumption. This paper presents a new data standard for reporting energy performance and related product information that can be adopted internationally. To inform the development of this standard, we explore the existing energy efficiency market data for the two example products of TVs and Room Air Conditioners. This paper discusses current/future use cases of appliance level energy efficiency data across all stakeholders, including consumers, retailers/manufacturers, global standards organizations, third party service providers, and regulatory agencies. It also explains the key benefits of moving to a common international data framework for energy efficiency, such as: 1) a centralized product information repository for comparing energy use, ratings/certifications, and pricing data 2) improved access to relevant consumer electronics and appliance data to facilitate new policy development and harmonization across markets 3) enablement of retailers and other third parties to embed actionable energy efficiency information as part of the consumer experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and Infrastructure Upgrades on Nuclear Clean-up Sites: The Hanford Experience - 18641

The Hanford site, located in southeastern Washington, produced much of our nation's weapons-grade plutonium for the Defense nuclear weapons program. This production lasted the better part of four decades with production ending in 1987. Since 1987, the focus of the Hanford site has turned to clean-up activities. Mission Support Alliance (MSA) is the integrator of the multi-contractor effort to clean up the Hanford site. MSA collaborates with the U.S. Department of Energy (DOE) and all Hanford site contractors in finding and implementing new, cost-saving, safe and practical solutions to cleanup challenges with a continual focus on innovative processes and technologies that reduce costs, energy use and bring safety improvements to the site. Support Services include environmental integration and land management; fleet and road maintenance; water/electric and utilities; cyber security and information management as well as the preservation of the site's cultural artifacts. This paper describes the process, challenges, and focus on infrastructure upgrade and energy efficiency projects in the context of a multi-contractor nuclear clean-up site. Project development and new technology deployment at Hanford has long been plagued with economic challenges. For example, despite extensive auditing, analysis, and project development, most of the energy-related projects on the Hanford site have gone unfunded due to the low cost of electricity, the relatively high cost of labor, and costs associated with detailed safety and cultural reviews. - The Hanford site is a direct-service customer of the Bonneville Power Administration (BPA) and has a marginal electricity rate of $0.033/kWh. - Labor costs on the Hanford site track high because of the requirements associated with the safety and security necessary to operate a legacy nuclear weapons complex. - In partnership with three federally recognized and other affected Native American tribes (Yakama Nation, Confederated Tribes of the Umatilla Indian Reservation, the Nez Perce Tribe, and Wanapum People), most activities on the Hanford site are afforded in-depth cultural reviews. To work within these constraints, the MSA Energy Management team has embarked on a three-pronged approach to energy project development: Program Visibility: The MSA Energy Management team has promoted both project opportunities and requirements across the Hanford site. This information comes in the form of site-wide newsletters, group meetings, e-mails, success stories, and recognition of staff. Single-point Analysis: To by-pass the inevitable duplications of effort, learning curve issues, and to improve project consistency/delivery, the MSA Energy Management team serves as the single resource to the site for energy project analysis. This resource includes initial assessment, engineering analysis, efficiency calculation and project recommendations. Contractor/utility Interface: In addition to the infrastructure under its own purview, MSA provides all support services for the contractor/utility interface. These activities include formulation and submission of incentive-based efficiency projects, project tracking, and incentive awards. All incentive awards are forwarded to the relevant contractor and then highlighted in the visibility campaign. Successful energy efficiency projects at Hanford have included high efficiency heating, ventilation, air conditioning (HVAC) systems, interior and exterior lighting/lighting control systems, pump and motor systems, and the right-sizing of transformers and area-wide electrical distribution systems. Prior to the initiation of this program and structure (roughly 3 years ago) the average annual energy efficiency incentive applied for and received was under $10,000, with an annual energy savings of approximately 36,000 kilowatt hours (kWh). In fiscal year 2017, the annual incentive received was over $419,000, with identified energy savings of over 1.3 million kWh. Details and case studies of the major project accomplishments are included. The success of this program can be traced to an understanding of the constraints, the development of a program to address these constraints, and good communication/coordination across DOE and the multiple contractors serving the Hanford site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

With the current movement toward net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Chapter 1: Introduction. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

This chapter provides a set of model protocols for determining energy and demand savings that result from specific energy efficiency measures implemented through state and utility efficiency programs. The methods described here are approaches that are or are among the most commonly used and accepted in the energy efficiency industry for certain measures or programs. As such, they draw from the existing body of research and best practices for energy efficiency program evaluation, measurement, and verification (EM&V). These protocols were developed as part of the Uniform Methods Project (UMP), funded by the U.S. Department of Energy (DOE). The principal objective for the project was to establish easy-to-follow protocols based on commonly accepted methods for a core set of widely deployed energy efficiency measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identifying Cost-Effective Residential Energy Efficiency Opportunities for the Kauai Island Utility Cooperative

This analysis is an update to the 2005 Energy Efficiency Potential Study completed by KEMA for the Kauai Island Utility Cooperative (KIUC) and identifies potential energy efficiency opportunities in the residential sector on Kauai (KEMA 2005). The Total Resource Cost (TRC) test is used to determine which of the energy efficiency measures analyzed in the KEMA report are cost effective for KIUC toinclude in a residential energy efficiency program. This report finds that there remains potential energy efficiency savings that could be cost-effectively incentivized through a utility residential demand-side management program on Kauai if implemented in such a way that the program costs per measure are consistent with the current residential program costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Highlight: NREL Delivers In-Home HVAC Efficiency Testing Solutions (Fact Sheet)

Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods that can be used by technicians, researchers, or interested homeowners to verify the correct operation and energy efficiency of a home's air conditioning equipment. An efficiency validation method for mini-split heat pumps (MSHPs) - highly efficient refrigerant-based air conditioning and heating systems that permit room-by-room conditioning and control - will enable building researchers to easily explore the installed performance of this class of equipment. MSHPs are very popular overseas and are gaining market share in energy efficient home upgrades throughout the United States. Yet, because MSHPs have multiple variable-speed components that work in tandem, their performance is challenging to measure in a real home. NREL researchers developed a field evaluation method including test equipment, methods, and data analysis to determine the installed performance of this equipment in occupied homes. A field test was conducted to validate the method. When testing a home's operation, it is often important to simulate occupancy within an unoccupied home. That way, the researcher will know the actual usage profiles for heat and moisture generation; this removes the uncertainty associated with real occupants. The second test method details a standardized protocol for generating heat and moisture loads, to mimic occupants and their activities by using heaters and humidifiers. Realistic heat and moisture loads can be used to drive air conditioning systems, evaluate air distribution systems, and examine building enclosure technologies. These loads are drawn from the Building America House Simulation Protocols. Proper application of the method will result in better comparison between performance of the test home and its simulated analogue. This method is also validated by field testing. These test methods are now available in two technical reports. The methods can be used widely by the building research community to confirm proper operation of space conditioning equipment in homes, thereby improving thermal comfort, building health, and durability. National objectives for cost-effective energy savings in the residential sector can be met more quickly and with greater consistency.

14 SOLAR ENERGY↗

Naphthalene‐Diimide‐Based Ionenes as Universal Interlayers for Efficient Organic Solar Cells

Abstract Self‐doping ionene polymers were efficiently synthesized by reacting functional naphthalene diimide (NDI) with 1,3‐dibromopropane ( NDI‐NI ) or trans ‐1,4‐dibromo‐2‐butene ( NDI‐CI ) via quaternization polymerization. These NDI‐based ionene polymers are universal interlayers with random molecular orientation, boosting the efficiencies of fullerene‐based, non‐fullerene‐based, and ternary organic solar cells (OSCs) over a wide range of interlayer thicknesses, with a maximum efficiency of 16.9 %. NDI‐NI showed a higher interfacial dipole (Δ), conductivity, and electron mobility than NDI‐CI , affording solar cells with higher efficiencies. These polymers proved to efficiently lower the work function ( WF ) of air‐stable metals and optimize the contact between metal electrode and organic semiconductor, highlighting their power to overcome energy barriers of electron injection and extraction processes for efficient organic electronics.

Liu, Ming↗