Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Microelectronic Chips For Radiation-Dose Tests

Custom-made single-chip complementary metal-oxide semiconductor (CMOS) integrated circuit designed to reveal effects of ionizing radiation on itself and similar integrated circuits. Potential terrestrial use: safety-oriented monitoring of ionizing radiation at nuclear powerplants, nuclear-waste sites, and the like.

Buehler, Martin G.↗

SU-E-T-258: Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy

Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attaching FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by the Industrial R&D program of MOTIE/KEIT. [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

Dismantling Structures and Equipment of the MR Reactor and its Loop Facilities at the National Research Center 'Kurchatov Institute' - 12051

In 2008 a design of decommissioning of research reactors MR and RFT has been developed in the National research Center 'Kurchatov institute'. The design has been approved by Russian State Authority in July 2009 year and has received the positive conclusion of ecological expertise. In 2009-2010 a preparation for decommissioning of reactors MR and RFT was spent. Within the frames of a preparation a characterization, sorting and removal of radioactive objects, including the irradiated fuel, from reactor storage facilities and pool have been executed. During carrying out of a preparation on removal of radioactive objects from reactor sluice pool water treating has been spent. For these purposes modular installation for clearing and processing of a liquid radioactive waste 'Aqua - Express' was used. As a result of works it was possible to lower volume activity of water on three orders in magnitude that has allowed improving essentially of radiating conditions in a reactor hall. Auxiliary systems of ventilation, energy and heat supplies, monitoring systems of radiating conditions of premises of the reactor and its loop-back installations are reconstructed. In 2011 the license for a decommissioning of the specified reactors has been received and there are begun dismantling works. Within the frames of works under the design the armature and pipelines are dismantled in a under floor space of a reactor hall where a moving and taking away pipelines of loop facilities and the first contour of the MR reactor were replaced. A dismantle of the main equipment of loop facility with the gas coolant has been spent. Technologies which were used on dismantle of the radioactive contaminated equipment are presented, the basic works on reconstruction of systems of maintenance of on the decommissioning works are described, the sequence of works on the decommissioning of reactors MR and RFT is shown. Dismantling works were carried out with application of means of a dust suppression that, in aggregate with standard means at such works of individual protection of the personnel and devices of radiating control, has allowed to lower risk of action of radiation on the personnel, the population and environment at the expense of reduction of volume activity of radioactive aerosols in air. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo Study of Feasibility of Passive Time-Coincidence Measurements for Monitoring Large Fissile Storage Arrays

Monitoring the amount of HEU in large (metric tons) storage arrays with passive time coincidence distribution measurements is complicated by a variety of effects. These include: (1) time correlated background from HEU outside the particular localized section of the storage array being monitored, (2) cosmic radiation induced fission of nearby array materials, and (3) how large a portion of the array can be monitored with a set of detectors at a particular location in the array. Such a large storage array is typically rows of 2 wide and 3 high birdcages (metal structures that maintain safe nuclear criticality spacing between stored HEU castings) separated by 2-foot-wide aisles between rows. This evaluation investigates how large an array of birdcages can be monitored by two 4x4 arrays of proton recoil scintillators. Monte Carlo simulations provided the time distribution of coincidences, multiplets (number of times n detection events occur in a time interval), and Feynman variance as a function of the length of the array. These calculations were performed for hypothetical arrays of 18 kg HEU standard Y-12 storage castings spaced 20 in apart. These types of arrays are used because the spacing between HEU castings are loosely coupled in that the castings at the ends of the arrays only interact with adjacent castings; this makes monitoring of the entire array difficult with detectors at a particular location in the array.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Beam Halo Monitor

Our innovative approach is to design the Beam Halo Monitor, where beam induced synchrotron radiation will be used to monitor the beam Halo. This involves an original scheme of light collection using a coronograph for measuring beam halo.

43 PARTICLE ACCELERATORS↗

Remote monitoring of Alpha Gamma hot cell facility by ARG-US RFID system - 15177

Argonne National Laboratory (Argonne) has developed a monitoring and tracking system for nuclear materials based on radio frequency identification (RFID) technology. The system, called ARG-US ('Watchful Guardian'), has been in fielding testing and applications at selected U.S. Department of Energy (DOE) sites since 2010. ARG-US utilizes battery-powered tags to remotely and continuously monitor the environmental parameters, e.g., radiation levels, of the tagged items such as containers of radioactive materials. To demonstrate that the system can monitor nuclear and radiological facilities as well, a compact system was installed in the Alpha Gamma Hot Cell Facility (AGHCF) at Argonne in 2013. AGHCF is a Hazard Category 2 non-reactor nuclear facility that is being decommissioned. It is also being used to support de-inventory of other facilities on the Argonne site. As such, large quantities of radioactive materials and wastes are being discharged from the hot cell, loaded into transport containers, and shipped away. The deployed ARG-US system monitors worker areas, material transfer areas, cell exhaust HEPA filters, and?on a rover/robot?in-cell locations of AGHCF. Thus far, the system is performing as designed and yielding results that can be corroborated by existing surveillance means. The in-cell unit is particularly valuable, as it yields information that would otherwise be hard to obtain. In time, the benefits of automated monitoring 24/7 by ARG-US should become apparent and may lead to a fuller system with more distributed tags in the hot cell areas until the facility is fully decommissioned. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

State of the Art in Electronic Dosemeters for Neutrons

The paper presents an overview of electronic personal dosemeters for neutrons in mixed neutron/photon fields. The energy response of commercially available electronic dosemeters in quasi-monoenergetic neutron fields and their performance in working places is discussed. The response curves are extended to high-energy neutrons up to 100 MeV, new prototype dosemeters are described and discussed especially for use at high-energy accelerators and in space.

61 RADIATION PROTECTION AND DOSIMETRY↗

2021 Idaho National Laboratory Site Environmental Report

The INL Site’s operations, as well as the ongoing cleanup, necessarily involve a commitment to environmental stewardship and full compliance with environmental protection laws. As part of this commitment, the INL Site Environmental Report is prepared annually to inform the public, regulators, stakeholders, and other interested parties of the INL Site’s environmental performance during the year. This report is published for the DOE-ID in compliance with DOE O 231.1B, “Environment, Safety and Health Reporting.” Its purpose is to: • Present the INL Site, mission, and programs • Report compliance status with applicable federal, state, and local regulations • Describe the INL Site environmental programs and activities • Summarize results of environmental monitoring • Discuss potential radiation doses to the public residing in the vicinity of the INL Site • Report on ecological monitoring and research conducted by contractors and affiliated agencies and by independent researchers through the Idaho National Environmental Research Park • Describe quality assurance methods used to ensure confidence in monitoring data • Provide supplemental technical data and reports that support the INL Site Environmental Report (https://idahoeser.inl.gov/publications.html).

99 GENERAL AND MISCELLANEOUS↗

Radiation Data Portal: Connection of Radiation Measurements on Airplane Flights with Observations of Solar-Terrestrial Environment

The impact of solar radiation dramatically increases at high altitudes in the Earth’s atmosphere and in space. Therefore, continuous monitoring of the radiation environment is critical for the safety of aircraft and spacecraft crews and passengers. Addressing the problem requires a complex approach of integration of different data sources and enhancement of the visualization and search capabilities. The Radiation Portal Database represents an interactive web-based application for convenient search and visualization of in-flight radiation measurements and exploration of various properties related to the radiation environment. The primary element of the Radiation Portal back-end is a MySQL relational database that currently contains the radiation measurements obtained from the Automated Radiation Measurements for Aerospace Safety (ARMAS)device, and soft X-ray and proton fluxes from Geostationary Orbiting Environmental Satellite (GOES). The developed Application Programming Interface (API) and related Python routines allow a user to retrieve the database records directly and efficiently, without interaction with the web interface. As a use case of the Radiation Portal, we examine the properties of the ARMAS flights taken during the enhanced Solar Proton (SP) fluxes and compare them to the flights of similar time and location taken during SP-quiet periods.

SMD↗

Long Term Stability Monitoring of Aqua MODIS Thermal Emissive Bands through Radiative Transfer Modeling

Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been in operation providing continuous global observations for science research and applications since 2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitored through inter-comparisons with measurements by hyperspectral infrared sensors, such as AIRS on Aqua and IASI on MetOp satellite, or through long term vicarious monitoring over cold targets, such as Dome- C and deep convective clouds (DCC). In this paper, a radiative transfer modeling-based simulation model using Community Radiative Transfer Model (CRTM) is developed to perform the long-term monitoring of the stability of TEBs of Aqua MODIS. CRTM is a fast-radiative transfer model for calculations of radiances for satellite infrared radiometers and is able to output infrared radiance and brightness temperature at spectral bands of MODIS. Long term European Centre for Medium-Range Weather Forecasts (ECMWF) global atmospheric reanalysis data, such as temperature and humidity profiles, are used as inputs to the CRTM simulation. By confining the area of interest to be over low to middle latitude ocean, the long-term stabilities of selected Aqua MODIS TEBs are monitored through Observation–Background (O-B) brightness temperature (BT) bias between MODIS measurements and BT retrieval from CRTM simulation. The consistency and relative stability between Aqua MODIS and ECMWF reanalysis data for surface channels of MODIS are evaluated. In addition, the radiative transfer modeling with CRTM enables us to evaluate the impacts of long term variation of global CO2 distribution on the O-B BT biases for CO2 channels of Aqua MODIS through comparison of simulations with constant or long term variable CO2 as inputs. The O-B analysis with RTM show that Aqua MODIS surface channels are all radiometrically stable with yearly BT bias drift less than 0.004K/year for B20, B22, B23 and ~0.01K/year for B31 and B32. The CO2 absorption channels of Aqua MODIS, e.g. B33-B36, are stable with BT bias drift < 0.005K/year.

MODIS↗

An integral quality monitoring system for real-time verification of intensity modulated radiation therapy

Purpose: To develop an independent and on-line beam monitoring system, which can validate the accuracy of segment-by-segment energy fluence delivery for each treatment field. The system is also intended to be utilized for pretreatment dosimetric quality assurance of intensity modulated radiation therapy (IMRT), on-line image-guided adaptive radiation therapy, and volumetric modulated arc therapy. Methods: The system, referred to as the integral quality monitor (IQM), utilizes an area integrating energy fluence monitoring sensor (AIMS) positioned between the final beam shaping device [i.e., multileaf collimator (MLC)] and the patient. The prototype AIMS consists of a novel spatially sensitive large area ionization chamber with a gradient along the direction of the MLC motion. The signal from the AIMS provides a simple output for each beam segment, which is compared in real time to the expected value. The prototype ionization chamber, with a physical area of 22x22 cm{sup 2}, has been constructed out of aluminum with the electrode separations varying linearly from 2 to 20 mm. A calculation method has been developed to predict AIMS signals based on an elementwise integration technique, which takes into account various predetermined factors, including the spatial response function of the chamber, MLC characteristics, beam transmission through the secondary jaws, and field size factors. The influence of the ionization chamber on the beam has been evaluated in terms of transmission, surface dose, beam profiles, and depth dose. The sensitivity of the system was tested by introducing small deviations in leaf positions. A small set of IMRT fields for prostate and head and neck plans was used to evaluate the system. The ionization chamber and the data acquisition software systems were interfaced to two different types of linear accelerators: Elekta Synergy and Varian iX. Results: For a 10x10 cm{sup 2} field, the chamber attenuates the beam intensity by 7% and 5% for 6 and 18 MV beams, respectively, without significantly changing the depth dose, surface dose, and dose profile characteristics. An MLC bank calibration error of 1 mm causes the IQM signal of a 3x3 cm{sup 2} aperture to change by 3%. A positioning error in a single 5 mm wide leaf by 3 mm in 3x3 cm{sup 2} aperture causes a signal difference of 2%. Initial results for prostate and head and neck IMRT fields show an average agreement between calculation and measurement to within 1%, with a maximum deviation for each of the smallest beam segments to within 5%. When the beam segments of a prostate IMRT field were shifted by 3 mm from their original position, along the direction of the MLC motion, the IQM signals varied, on average, by 2.5%. Conclusions: The prototype IQM system can validate the accuracy of beam delivery in real time by comparing precalculated and measured AIMS signals. The system is capable of capturing errors in MLC leaf calibration or malfunctions in the positioning of an individual leaf. The AIMS does not significantly alter the beam quality and therefore could be implemented without requiring recommissioning measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stack Monitor Operating Experience Review

Stack monitors are used to sense radioactive particulates and gases in effluent air being vented from rooms of nuclear facilities. These monitors record the levels and types of effluents to the environment. This paper presents the results of a stack monitor operating experience review of the U.S. Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS) database records from the past 18 years. Regulations regarding these monitors are briefly described. Operating experiences reported by the U.S. DOE and in engineering literature sources were reviewed to determine the strengths and weaknesses of these monitors. Electrical faults, radiation instrumentation faults, and human errors are the three leading causes of failures. A representative “all modes” failure rate is 1E-04/hr. Repair time estimates vary from an average repair time of 17.5 hours (with spare parts on hand) to 160 hours (without spare parts on hand). These data should support the use of stack monitors in any nuclear facility, including the National Ignition Facility and the international ITER project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design for a Longitudinal Density Monitor for the LHC

Synchrotron radiation is currently used on the LHC for beam imaging and for monitoring the proton population in the 3 microsecond abort gap. In addition to these existing detectors, a study has been initiated to provide longitudinal density profiles of the LHC beams with a high dynamic range and a 50ps time resolution. This would allow for the precise measurement both of the bunch shape and the number of particles in the bunch tail or drifting into ghost bunches. A solution is proposed based on counting synchrotron light photons with two fast avalanche photo-diodes (APD) operated in Geiger mode. One is free-running but heavily attenuated and can be used to measure the core of the bunch. The other is much more sensitive, for measurement of the bunch tails, but must be gated off during the passage of the bunch to prevent the detector from being swamped. An algorithm is then applied to combine the two measurements and correct for the detector dead-time, afterpulsing and pile-up effects. Initial results from laboratory testing of this system are described here.

43 PARTICLE ACCELERATORS↗

ORNL Trusted Corridors Project: Watts Bar Dam Inland Waterway Project

Radiation has existed everywhere in the environment since the Earth's formation - in rocks, soil, water, and plants. The mining and processing of naturally occurring radioactive materials for use in medicine, power generation, consumer products, and industry inevitably generate emissions and waste. Radiological measuring devices have been used by industry for years to measure for radiation in undesired locations or simply identify radioactive materials. Since the terrorist attacks on the United States on 9-11-01 these radiation measuring devices have proliferated in many places in our nation's commerce system. DOE, TVA, the Army Corps and ORNL collaborated to test the usefulness of these devices in our nation's waterway system on this project. The purpose of the Watts Bar Dam ORNL Trusted Corridors project was to investigate the security, safety and enforcement needs of local, state and federal government entities for state-of-the-art sensor monitoring in regards to illegal cargo including utilization of the existing infrastructure. TVA's inland waterways lock system is a recognized and accepted infrastructure by the commercial carrier industry. Safety Monitoring activities included tow boat operators, commercial barges and vessels, recreational watercraft and their cargo, identification of unsafe vessels and carriers, and, monitoring of domestic and foreign commercial vessels and cargo identification. Safety Enforcement activities included cargo safety, tracking, identification of hazardous materials, waterway safety regulations, and hazardous materials regulations. Homeland Security and Law Enforcement Applications included Radiological Dispersive Devices (RDD) identification, identification of unsafe or illicit transport of hazardous materials including chemicals and radiological materials, and screening for shipments of illicit drugs. In the Fall of 2005 the SensorNet funding for the project expired. After several unsuccessful attempts to find a Federal sponsor to continue with the project, the Watts Bar Dam Project was canceled and the Exploranium radiation monitors were removed from the doors of Watts Bar Dam in early 2006. The DHS Domestic Nuclear Detection Office decided to proceed with a Pilot building on the ORNL work performed at the TN and SC weigh stations in the highway sector of the Trusted Corridors project and eventually expanded it to other southern states under the name of Southeastern Corridor Pilot Project (SETCP). Many of the Phase I goals were achieved however real-world test data of private watercraft and barges was never obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray And EUV Spectroscopy Of Highly Charged Tungsten Ions

The Berlin EBIT has been established by the Max-Planck-Institut fuer Plasmaphysik to generate atomic physics data in support of research in the field of controlled nuclear fusion, by measuring the radiation from highly charged ions in the x-ray, extreme ultraviolet and visible spectral ranges and providing valuable diagnostics for high temperature plasmas. In future fusion devices, for example ITER, currently being constructed at Cadarache, France, the plasma facing components will be armored with high-Z materials, most likely tungsten, due to the favorable properties of this element. At the same time the tremendous radiation cooling of these high-Z materials represents a threat to fusion and obliges one to monitor carefully the radiation. With EBIT a selected ensemble of ions in specific charge states can be produced, stored and excited for spectroscopic investigations. Employing this technique, we have for example resolved the wide structure observed around 5 nm at the ASDEX Upgrade tokamak as originating from E1-transitions into the open 4d shell of tungsten ions in charge states 25+ to 37+ producing a band-like emission pattern. Further, these ions emit well-separated M1 lines in the EUV range around 65 nm suitable for plasma diagnostics. Kr-like to Cr-like tungsten ions (38+ to 50+) show strong soft-x-ray lines in the range 0.5 to 2 and 5 to 15 nm. Lines of even higher charged tungsten ions, up to Ne-like W{sup 64+}, abundant in the core plasma of present and future fusion test devices, have been investigated with high resolution Bragg-crystal spectroscopy at 0.13 nm. Recently, x-ray spectroscopic measurements of the dielectronic recombination LMn resonances of W{sup 60+} to W{sup 67+} ions have been preformed and compare well with atomic structure calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring of Occupational Exposures in Albania Using TLD-100 cards (2003-2007)

In our paper is described the monitoring of occupational staff that works in ionising radiation field of the diagnostic centres in Albania for 2003-2007, and is analysed and discussed the mean annual dose rate recorded for above-mentioned period. The monitoring was based in TLD-100 dosimetric cards and the control was performed all over the country on bimonthly basis covering main and important cities like: Tirana, Durresi, Shkodra, Fieri, Vlora, Korca etj. The Department of Human and Environment Protection, at the Centre of Applied Nuclear Physics, through the dosimetric service carried out the monitoring for around 350 radiation workers.

61 RADIATION PROTECTION AND DOSIMETRY↗

CONNECTION BETWEEN THE ACCRETION DISK AND JET IN THE RADIO GALAXY 3C 111

We present the results of extensive multi-frequency monitoring of the radio galaxy 3C 111 between 2004 and 2010 at X-ray (2.4-10 keV), optical (R band), and radio (14.5, 37, and 230 GHz) wave bands, as well as multi-epoch imaging with the Very Long Baseline Array (VLBA) at 43 GHz. Over the six years of observation, significant dips in the X-ray light curve are followed by ejections of bright superluminal knots in the VLBA images. This shows a clear connection between the radiative state near the black hole, where the X-rays are produced, and events in the jet. The X-ray continuum flux and Fe line intensity are strongly correlated, with a time lag shorter than 90 days and consistent with zero. This implies that the Fe line is generated within 90 lt-day of the source of the X-ray continuum. The power spectral density function of X-ray variations contains a break, with a steeper slope at shorter timescales. The break timescale of 13{sup +12}{sub -6} days is commensurate with scaling according to the mass of the central black hole based on observations of Seyfert galaxies and black hole X-ray binaries (BHXRBs). The data are consistent with the standard paradigm, in which the X-rays are predominantly produced by inverse Compton scattering of thermal optical/UV seed photons from the accretion disk by a distribution of hot electrons-the corona-situated near the disk. Most of the optical emission is generated in the accretion disk due to reprocessing of the X-ray emission. The relationships that we have uncovered between the accretion disk and the jet in 3C 111, as well as in the Fanaroff-Riley class I radio galaxy 3C 120 in a previous paper, support the paradigm that active galactic nuclei and Galactic BHXRBs are fundamentally similar, with characteristic time and size scales proportional to the mass of the central black hole.

79 ASTRONOMY AND ASTROPHYSICS↗