Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The large-area hybrid-optics CLAS12 RICH: Assembling, commissioning and first data-taking

Here, the first module of a Ring Imaging Cherenkov detector has been recently installed on the CLAS12 spectrometer at the Jefferson Lab (JLab) to provide the experiment with kaon identification in the momentum range between 3 and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors and highly-segmented photon detectors. We report here on the assembly and installation of the RICH and we show the first preliminary results obtained during the commissioning of the detector and the first physics data taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the muon flux produced by 10.6 GeV electrons in a beam dump

This paper proposes the results of an experiment to assess the muon flux produced by the interaction of a 10.6 GeV electron beam with the Hall-A beam dump at Jefferson Lab (JLab). The goal was to benchmark Monte Carlo simulations that are an essential tool for estimating beam-related backgrounds in beam-dump experiments aimed at searching for rare events, such as the Beam Dump eXperiment (BDX) planned at JLab. Beam-produced muons were measured with a CsI(Tl) crystal sandwiched between a set of segmented plastic scintillators placed at two different distances from the dump: 25.7 m and 28.8 m. At each location the muon flux was sampled at different vertical positions with respect to the beam height. Data have been compared with detailed Monte Carlo simulations using FLUKA for the muon production in the dump and propagation to the detector, and GEANT4 to simulate the detector response. The good agreement between data and simulations, within the uncertainties of the soil composition and density, exhibit the validity of our simulation tools to predict the beam-related muon background in electron beam-dump experiments at ~10 GeV.

47 OTHER INSTRUMENTATION↗

Design and operation of a windowless gas target internal to a solenoidal magnet for use with a megawatt electron beam

A windowless hydrogen gas target of nominal thickness 10 19 cm -2 is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Lab’s Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic equilibrium was simulated in COMSOL to provide a better understanding of its optimal operation at other working points. We have determined that a windowless gas target with sufficiently high density for DarkLight’s experimental needs is feasible in an ERL environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new Transition Radiation detector based on GEM technology

Transition Radiation Detectors (TRD) have the potential feature of separating particles by their gamma factor. Classical TRDs are based on Multi-Wire Proportional Chambers (MWPC) or straw tubes, using a Xenon based gas mixture to efficiently absorb transition radiation photons. These detectors operate well in experiments with relatively low particle multiplicity. The performance of MWPC-TRD in experiments with luminosity of order 10 34 cm 2 s –1 and above, is significantly deteriorated due to the high particle multiplicity and channel occupancy. Replacing MWPC or straw tubes with a high granularity Micro Pattern Gas Detectors (MPGD) like Gas Electron Multipliers (GEMs), could improve the performance of the TRD. In addition, GEM technology allows one to combine a tracker with TRD identification (GEM-TRD/T). This report presents a new TRD development based on GEM technology for the future Electron Ion Collider (EIC). The first beam test was performed at Jefferson Lab (Hall-D) using 3–6 GeV electrons. A GEM-TRD/T module has been exposed to electrons with and without a fiber radiator. First results of test beam measurements and comparison with Geant4 Monte Carlo are introduced here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab

This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 drift chamber system

The CEBAF Large Acceptance Spectrometer at 12~GeV (CLAS12) is located in Hall~B, one of the experimental halls at Jefferson Lab. The forward part of CLAS12 is built around a superconducting toroidal magnet. The six coils of the toroid divide the detector azimuthally into six sectors. Each sector contains three multi-layer drift chambers for reconstructing the trajectories of charged particles originating from a fixed target. Each of the 18 planar chambers has two ``superlayers'' of six layers each, with the wires in the two adjacent superlayers oriented at ± 6° stereo angles. Each layer has 112 hexagonal cells spanning a range from about 5° to 40° in polar angle. The six-layer structure provides redundancy in track segment finding and good tracking efficiency even in the presence of some individual wire inefficiency. The design, construction, operation, and calibration methods are described, and estimates of the efficiency and resolution are presented from in-beam measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 superconducting magnets

As part of the Jefferson Lab 12 GeV upgrade, the Hall B CLAS12 system requires two superconducting iron-free magnets — a torus and a solenoid. The physics requirements to maximize space for the detectors guided engineers toward particular coil designs for each of the magnets which, in turn, led to the choice of using conduction cooling. The torus consists of 6 trapezoidal NbTi coils connected in series with an operating current of 3770 A. The solenoid is an actively shielded 5 T magnet consisting of 5 NbTi coils connected in series operating at 2416 A. Within the hall, the two magnets are located in close proximity to each other and are completely covered both inside and outside by particle detectors. Stringent size limitations were imposed for both magnets and introduced particular design and fabrication challenges. This paper describes the design, construction, installation, commissioning, and operation of the two magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The PRad windowless gas flow target

In this work, we report on a windowless, high-density, gas flow target at Jefferson Lab that was used to measure $r_p$, the root-mean-square charge radius of the proton. To our knowledge, this is the first such system used in a fixed-target experiment at a (non-storage ring) electron accelerator. The target achieved its design goal of an areal density of 2$\times$10$^{18}$ atoms/cm$^2$, with the gas uniformly distributed over the 4 cm length of the cell and less than 1% residual gas outside the cell. This design eliminated scattering from the end caps of the target cell, a problem endemic to previous measurements of the proton charge radius in electron scattering experiments, and permitted a precise, model-independent extraction of $r_p$ by reaching unprecedentedly low values of $Q^2$, the square of the electron's transfer of four-momentum to the proton.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A concept for polarized 3 He targets for high luminosity scattering experiments in high magnetic field environments

In this work, we present the conceptual design of a polarized 3 He target to be used for high luminosity scattering experiments within high magnetic field environments. This two-cell target will take advantage of advancements in optical pumping techniques at high magnetic field to create 60% longitudinally polarized 3 He gas in a pumping cell within a uniform magnetic field above 1 T. By transferring the polarized gas to a cryogenic target cell, the gas density is increased to create a target thickness suitable for high luminosity applications. We discuss the general design of this scheme, and plans for its application in Jefferson Lab’s CLAS12 detector.

3He polarization↗

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH detector

In this work, we present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel’s properties such as gain, quantum efficiency, signal crosstalk between neighboring pixels, and determine the signal threshold values to optimize their efficiency to detect Cherenkov photons. A recently published state-of-the-art mathematical model, describing photon detector response functions measured in low light conditions, was extended to include the description of the crosstalk contributions to the spectra. The database of extracted parameters will be used for the final selection of the MaPMTs, their arrangement in the new RICH detector, and the optimization of the operational settings of the front-end electronics. The results show that the characteristics of the H12700 MaPMTs satisfy our requirements for the position-sensitive single photoelectron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Møller polarimetry for PREX-2 and CREX

The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically , be known with 1% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.89% for PREX-2, and 0.85% for CREX. The uncertainty is purely systematic, accumulated from several different sources, but dominated by our knowledge of the target polarization. Our analysis also demonstrates the need for accurate atomic wave functions in order to correct for the Levchuk Effect. We describe the details of the polarimeter operation and analysis, as well as (for CREX) a comparison to results from a different polarimeter based on Compton scattering.

43 PARTICLE ACCELERATORS↗

An overview of how parity-violating electron scattering experiments are performed at CEBAF

Parity-violating electron-scattering experiments represent an important focus of the nuclear physics experimental program at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. These experiments pose significant challenges because the scattering asymmetries can be very small, of the order parts-per-million and smaller. To succeed, the properties of the electron beam such as current, position, size and energy, must be very nearly identical in the two electron-polarization spin states (parallel and anti-parallel relative to the direction of beam motion at the scattering target). This paper describes the origins of unwanted helicity-correlated beam asymmetries present on the electron beam and methods to minimize them to acceptable levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Q weak high performance LH 2 target

A high-power liquid hydrogen target was built for the Jefferson Lab Q weak experiment, which measured the tiny parity-violating asymmetry in $\vec{e}$ p scattering at an incident energy of 1.16 GeV, and a Q 2 = 0.025 GeV 2 . To achieve the luminosity of 1.7 x 10 39 cm -2 s -1 , a 34.5 cm- long target was used with a beam current of 180 μA. The ionization energy-loss deposited by the beam in the target was 2.1 kW. The target temperature was controlled to within ±0.02 K and the target noise (density fluctuations) near the experiment's beam helicity- reversal rate of 960 Hz was only 53 ppm. The 58 liquid liter target achieved a head of 11.4 m (7.6 kPa) and a mass flow of 1.2 ± 0.3 kg/s (corresponding to a volume flow of 17.4 ± 3.8 l/s) at the nominal 29 Hz rotation frequency of the recirculating centrifugal pump. We describe aspects of the design, operation, and performance of this target, the highest power LH2 target ever used in an electron scattering experiment to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction, and performance of the GEM based radial time projection chamber for the BONuS12 experiment with CLAS12

Here, a new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar devices constructed for previous experiments, including cylindrical amplification layers constructed from single continuous GEM foils with less than 1% dead area. Particular attention had been paid to producing excellent geometric uniformity of all electrodes, including the very thin metalized polyester film of the cylindrical cathode. This manuscript describes the design, construction, and performance of this new detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗