Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “InC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Oak Ridge Response to Versatile Test Reactor Environmental Impact Statement Data Request

The Versatile Test Reactor (VTR) is a fast-spectrum test reactor being developed in the United States under the direction of the US Department of Energy Office of Nuclear Energy (DOE-NE). The VTR mission is to enable accelerated testing of advanced reactor fuels and materials required for advanced reactor technologies. The conceptual design of the 300 MWth sodium-cooled metallic-fueled pool-type fast reactor has been led by the US National Laboratories in collaboration with General Electric–Hitachi and Bechtel National, Inc. In support of the VTR project, DOE issued a Notice of Intent (NOI) in the Federal Register on August 5, 2019, announcing the intent to prepare an Environmental Impact Statement (EIS) in accordance with the National Environmental Policy Act (NEPA) and its implementing regulations. The EIS will evaluate alternatives for a versatile reactor–based fast-neutron source facility and associated facilities for the preparation, irradiation, and post-irradiation examination (PIE) of test/experimental fuels and materials. Specifically, the NOI identified two siting alternatives for the VTR reactor facility: Idaho National Laboratory (INL) or Oak Ridge National Laboratory (ORNL). In addition, the NOI also specified two siting alternatives for VTR fuel fabrication: INL and the Savannah River Site (SRS). This report provides information in response to data requests made to ORNL to fill in site-specific knowledge gaps to develop a high-quality EIS. The responses provided are not required to provide full details in every aspect; instead, they adequately bound possible environmental impacts or provide sufficient information to adequately assess likely environmental impacts. This work is being performed under a subcontract from INL to ORNL using DOE-NE funds and is directed by DOE-NE and DOE-ID. Leidos has been contracted by DOE-NE to write the VTR EIS, so most data requests have come from Leidos but were often routed through INL or DOE-ID. DOE-ID is overseeing the NEPA and EIS processes for the VTR project. Leidos will use the information provided in this report to inform the VTR EIS and will also cite this document to establish a clear, publicly available source of the information. Section 2 of this report briefly describes the proposed ORNL VTR Alternative and illustrates the location of the proposed site for the ORNL VTR Alternative. Sections 3 through 7 provide direct responses to data requests received by ORNL. These sections use a tabular format in which data requests are divided into separate items to be addressed; the items are numbered, the data requests are restated with more topical information included, and then the responses are provided. Initial data requests and follow-on requests for additional information (RAIs) are combined under the original data request fields. Finally, Section 8 presents summarized conclusions and describes future work.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of a Combined Raffinate Waste Stream for Mo-99 Production

Niowave, Inc., based in Lansing, Michigan, intends to produce Mo-99 from the fission of low enriched uranium (LEU) targets. In FY20, SRNL was tasked to provide technical assistance in identifying the primary waste raffinate present in Niowave’s commercial scale system and evaluating methods for disposal. Due to limited information on Niowave’s complete flowsheet and isotope recovery plans, a combined raffinate stream including the entire radionuclide inventory from the irradiated fuel was used for this evaluation. Results of the evaluation indicated the majority of the waste generated can be expected to be Class A; however radioisotopes such as Pu-239, Cs-137, Sr-90, and some of the shorter lived (< 5 year half-life) may challenge Niowave’s ability to meet the waste acceptance criteria for land burial. With appropriate waste management strategies, it is probable that Niowave’s waste could meet Class C requirements for all constituents, with the possible exception of Pu-239. More detailed information of Niowave’s processes are needed to form a more accurate understanding required to execute and effective, economic, and feasible waste management strategy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sandia National Laboratories Annual Site Environmental Report, 2019: New Mexico

Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the United States Department of Energy (DOE) National Nuclear Security Administration. The National Nuclear Security Administration’s Sandia Field Office administers the contract and oversees contractor operations at Sandia National Laboratories, New Mexico. Activities at the site support research and development programs with a wide variety of national security missions, resulting in technologies for nonproliferation, homeland security, energy and infrastructure, and defense systems and assessments. DOE and its management and operating contractor are committed to safeguarding the environment, assessing sustainability practices, and ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This report summarizes the environmental protection and monitoring programs in place at Sandia National Laboratories, New Mexico, during calendar year 2019. Environmental topics include air quality, ecology, environmental restoration, oil storage, site sustainability, terrestrial surveillance, waste management, water quality, and implementation of the National Environmental Policy Act. This report is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety, and Health Reporting, and has been approved for public distribution.

54 ENVIRONMENTAL SCIENCES↗

Sandia National Laboratories Annual Site Environmental Report, 2019: Tonopah Test Range, Nevada and Kaua'i Test Facility, Hawai'i

Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the United States Department of Energy (DOE) National Nuclear Security Administration. The National Nuclear Security Administration’s Sandia Field Office administers the contract and oversees contractor operations at Sandia National Laboratories, Tonopah Test Range (SNL/TTR) in Nevada and Sandia National Laboratories, Kaua‘i Test Facility (SNL/KTF) in Hawai‘i. Activities at SNL/TTR are conducted in support of DOE weapons programs and have operated at the site since 1957. SNL/KTF has operated as a rocket preparation launching and tracking facility since 1962. DOE and its management and operating contractor are committed to safeguarding the environment, assessing sustainability practices, and ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This report summarizes the environmental protection, restoration, and monitoring programs in place at SNL/TTR and SNL/KTF during calendar year 2019. Environmental topics include air quality, ecology, environmental restoration, oil storage, site sustainability, terrestrial surveillance, waste management, water quality, and implementation of the National Environmental Policy Act. This report is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety, and Health Reporting, and has been approved for public distribution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scale-Up of Electrode Coating and Flow-Field for Commercial Hydrogen Peroxide Electrolyzer: Cooperative Research and Development Final Report, CRADA Number CRD-17-00687

Hydrogen peroxide is currently produced at central chemical plants via the anthraquinone oxidation process. This process produces environmental pollutants that are costly to remediate, requires hazardous long distance shipping of highly concentrated peroxide (50% or 70%), and necessitates extra handling costs related to storage and dilution. Peroxygen Systems, Inc. (PSi) is developing breakthrough technology for on-site hydrogen peroxide production. PSi’s on-site on-demand electrolyzer can reduce the cost of producing hydrogen peroxide by 50%, while also completely eliminating the cost and safety issues associated with shipping and handling of high concentration hydrogen peroxide. The challenge for PSi is scaling. To support the next step toward commercialization (customer pilot tests), scaling the prototype into larger single cells and 20-40 cell stacks is required. In addition to internal hardware and flow-field design efforts at PSi, NREL will address three critical problems for this scale-up effort: (1) demonstrating a large scale roll-to-roll (R2R) process to coat uniform electrode materials for 100 cm2 and 500 cm2 stack testing, (2) demonstrating an in-line diagnostic to achieve better electrode quality control, and (3) performing in situ cell/stack testing to better understand and optimize the performance of the flow field design.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

Drone Video Platform—Collision Avoidance, Situational Awareness, and Communications

Small unmanned aerial systems are ideal for delivering sensors into areas that are inaccessible or too dangerous for human entry or manned aircraft over-flights. The systems can fly low and slow for enhanced sensitivity and in tight spaces where ordinary aircraft could never fit. We have configured and flown sensor payloads for radiation, chemical, and optical detection on small fixed-wing and rotary-wing aircraft. All the sensor packages provide telemetry, GPS coordinates, LIDAR distance ranging, and absolute time of day to microsecond accuracy. Payload weights range from less than 1 kg up to 5.5 kg. Currently, communications are over 2.4 GHz and 915 MHz radios, as well as over 4G LTE cellular data links. Real-time data feeds from the sensor payloads to web browser clients anywhere in the world are possible via a virtual EC2 server on the Amazon AWS cloud. In FY 2019, the Nevada National Security Site teamed with Virginia Tech, H3D Corp., and Unmanned Systems, Inc. to accomplish the four flight missions described in this report. A large part of this year’s mission goals were to demonstrate the ability to fly beyond visual line of sight (BVLOS).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using the Carbon Capture Simulation Initiative (CCSI) Tool to Design the Experiments in the Parametric Campaign of a Novel Compact Absorber for Carbon Capture

Gas absorption towers with structured packing and solvent have been used for Carbon Dioxide (CO 2 ) Capture for about many decades. To overcome process limitations and practical disadvantages for CO 2 capture from the stationary emitter (e.g. NG and coal power plant), many new designs have been proposed and explored at the various scales in the last decade with aim of either low energy penalty or low capital cost. To reduce the size of the absorption tower and hence the total cost of CO 2 capture, the University of Kentucky Center for Applied Energy Research Center (UK CAER) has designed and built a novel CO 2 capture absorption tower or Compact Absorber, integrated into an existing large-bench scale CO 2 capture unit. The Compact Absorber has three sections. The top of the column is a fogging section where the solvent is sprayed through a nozzle producing droplets flowing downward in a co-current fashion with the flue gas. The center of the column is a frothing section where the solvent and flue gas flow through regenerative frothing screens designed by Industrial Climate Solutions, Inc. The bottom of the column is a typical structured packing section were the flue gas and solvent flow in a counter-current fashion. The parametric campaign will be conducted in order to optimize the operating parameters for CO 2 capture including liquid/gas ratio, lean loading, and temperature, liquid residence time. A simulated flue gas with 14% CO 2 will be used along with a UK CAER developed proprietary solvent. The 100-hour parametric campaign is designed using a statistical approach of the Sequential Design of Experiments (sDOE). sDOE is one of the CCSI tools that provides an adaptive statistical approach for designing future experiments based on the results of previous experiments. Application of a typical DOE provides the user with the minimum number of experiments required to get the same data, but sDOE allows the user to make an informed choice of experiments based on the results of previous experiments. The complete absorption column has been constructed and has been partially commissioned. Initial data has been collected by operating using the fogging section and the frothing section. The fogging section produces solvent droplets of about 100 μm sauter mean diameter and as small as 25 μm using a hydraulic nozzle by BETE. The frothing section produces bubbles of about 5mm with high mixing of solvent promoting the higher mass transfer from gas to liquid. The absorber reaches the capture efficiency of about 50% with only two sections in operation. Based on the current results, it can be deduced that increasing the solvent feed temperature and including the packed section for absorption the capture efficiency will increase further. Initial data will be collected using all three sections of the absorber and will be used for sDOE. Non-Uniform Space Filling model of sDOE will be used to prioritize the input conditions resulting into maximum capture efficiency. sDOE is performed using the platform called Framework Optimization, Quantification of Uncertainty, and Surrogates (FOQUS). The method and results demonstrating the progress of the parametric campaign from the initial set of experiments to the final stage of obtaining optimized parameters using sDOE tool will be presented in detail.

20 FOSSIL-FUELED POWER PLANTS↗

Aircraft-Integrated Meteorological Measurement System (AIMMS) Instrument Handbook

The AIMMS-20 probe is manufactured by Aventech Research Inc. and measures platform position, velocity, attitude, ambient temperature, static pressure, and the differential pressures from a 5-port hemispheric gust probe, and combines all these measured data into a calculation of the ambient winds. A detailed description of the AIMMS-20 specifications is available here. Note: The Aventech engineers use the aircraft-centric frame of reference common to aeronautical engineering, which defines z as down.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Test Design and Plan for a Canister Deposition Field Demonstration

This report provides a high-level test plan for deploying three commercial 32PTH2 spent nuclear fuel (SNF) canisters inside NUHOMS Advanced Horizontal Storage Modules (AHSM) from Orano (formerly Transnuclear Inc.). The details contained in this report represent the best designs and approaches explored for testing as of this publication. Given the rapidly developing nature of this test program, some of these plans may change to accommodate new objectives or adapt in response to conflicting requirements. The goal of the testing is to collect highly defensible and detailed surface deposition measurements from the surface of dry storage systems in a marine coastal environment to guide chloride-induced stress corrosion crack (CISCC) research. To facilitate surface sampling, the otherwise highly prototypic dry storage systems will not contain SNF but rather will be electrically heated to mimic the thermal-hydraulic environment. Instrumentation throughout the canister, storage module, and environment will provide an extensive amount of information for the use of model validation. Manual sampling over a comprehensive portion of the canister surface at regular time intervals will offer a high-fidelity quantification of the conditions experienced in a harsh yet realistic environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

LandRAY Final Report

The overarching Project objective is to demonstrate the feasibility of using an innovative Power Take-Off (PTO) Module, to be used in the Columbia Power Technologies, Inc. (C·Power) utility-scale wave energy converter (WEC). The PTO Module uniquely combines a large-diameter, direct-drive, rotary permanent magnet generator; a patent-pending rail-bearing system; and a corrosion-resistant fiber-reinforced-plastic structure. The rail bearing system allows for: • A flexible non-rigid and low-cost generator frame as compared to conventional machines. • A reduction of air gap and consequently lower cost electromagnetic design • Ability to reduce costs by increasing diameter to much larger dimensions, while maintaining the small air gap. • A direct drive electro-mechanical solution that is the fastest and most precise approach for responding to the dynamic variability of forces from wave energy. The land-based test of the PTO Module (DDP1) will provide an important risk reduction phase, to demonstrate the reliability and feasibility of a large-diameter, small air-gap generator that is capable of delivering high efficiency, fault-tolerance and relatively simple "at-sea" maintenance capabilities – qualities that are essential for cost-effective wave energy devices. This is the first known test of such a system.

16 TIDAL AND WAVE POWER↗

Vendor-Independent Design Requirements for a Boiling Water Reactor Safety System Upgrade

This Vendor-Independent License Amendment Request (LAR) Framework Document is a research product developed for the Idaho National Laboratory Light Water Reactor Sustainability (LWRS) Program. It was developed by MPR Associates, Inc. with technical input from LWRS and Exelon Generation personnel. To accomplish the purpose of this research, an operating plant (Limerick Generating Station [LGS]) was used as a reference to provide a concrete example and to present a "top-down" view of design concepts consistent with functional requirements baseline documents (references X and Y) also developed for this research. While this document is written in a framework to support a complete LAR submittal, its purpose is to communicate research concepts and provide an example of how to present digital information necessary to address expectations with regard to leveraging the Alternate Review Process as provided in Digital Instrumentation and Controls Interim Staff Guidance #06, Revision 2, Licensing Process. To leverage that process, this research document presupposes that a utility would select a vendor platform which has been prequalified for safety-related by the United States Nuclear Regulatory Commission. While this document is written using the Exelon Generation Limerick Generating Station (LGS) Units 1 and 2 as a baseline, this document is a research product. This document contains no commitments and makes no binding design decisions for Exelon Generation. Exelon Generation is leveraging this research to support their in-progress LGS Plant Protection System (PPS) upgrade efforts and plans to leverage it for their Redundant Reactor Control System (RRCS) replacement. The LWRS Program appreciates the research support provided by Exelon Generation in the generation of this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intercomparison of Aerosol Instrumental Responses Using AEROTRAK, SMPS, and APS in a Simulated Building

In this work, three aerosol instruments were intercompared by using data collected from field campaigns in a simulated building environment during the last quarter of 2020 from October to December at Oak Ridge National Laboratory. The three aerosol instruments—AeroTrak Model 9110, Scanning Mobility Particle Spectrometer (SMPS) 3080L + 3025A, and Aerodynamic Particle Sizer (APS) 3320—were manufactured by TSI Inc. to perform in situ measurements of particle number concentration in the air. These instruments were co-located in one room in which an aerosol generator was used to produce a defined aerosol population for the instruments to sample and detect in each campaign. The SMPS measured aerosol particles with diameters from 0.01 to 0.7 µm, APS measured aerosol particles with diameters from 0.5 to 20 µm, and AeroTrak measured aerosol particles with diameters from 0.1 to 10 µm. The results suggest that although AeroTrak is fast and easy to use, it does not provide measurements comparable with those obtained by SMPS and APS. The differences in particle counts were orders of magnitude in size (i.e., the AeroTrak data were unreasonably small in the tested scenarios). The results clearly indicate that AeroTrak should not be used in ambient applications in which the level of particle concentration is expected to be high. This would cause difficulty to a campaign in which the dilution factor is unknow a priori. The high particle concentration could also lead to an erroneous aerosol size distribution (e.g., a bimodal size distribution was measured as opposed to a single-mode one). The number concentration limit that AeroTrak is expected to run reliably (i.e., with a counting coincidence error less than ±10%) is approximately three to four per cubic centimeter. This suggests that the instrument is best used in a clean room environment, not in an ambient or indoor application, such as the Flexible Research Platform campaigns.

47 OTHER INSTRUMENTATION↗

Net Metering Expansion on the Winnebago Tribe of Nebraska Reservation (Final Technical Report)

The Winnebago Tribe of Nebraska, through their affiliated economic development entity Ho-Chunk, Inc; their affiliated non-profit Ho-Chunk Community Development Corporation; and an additional project partner Nebraska Renewable Energy Systems conducted a community scale renewable energy project on their reservation in Nebraska. Over the two-year project period, we installed PV Solar systems on ten tribally owned commercial/retail/office facilities, which included both six roof mounted and four pole mount installations. The project was undertaken as a part of the Tribe’s broader initiative to increase renewable energy production on the reservation, reduce the Tribe’s financial obligations for purchasing energy, and lessen our reliance upon outside sources of energy to meet our basic needs. The project enabled us to formalize and strengthen community collaborations and build our capacity to pursue additional renewable energy opportunities that will enhance our energy sovereignty.

14 SOLAR ENERGY↗

Self-Disinfecting PPE Fabric [Factsheet]

Green Theme Technologies Inc. developed a chemical finishing technology that uses a high pressure, water-free, thermally triggered polymerization process to produce a thin conformal polymer coating around fabric fibers. This process can be used to embed selective, disinfectant chemicals to provide an anti-microbial, anti-viral finish to fabrics. In the face of COVID-19, the company hopes this process produces a permanent, laundry-durable, anti-pathogenic finish. Essentially, creating regenerative and reusable PPE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum Random Number Generator (QRNG)

The Los Alamos QRNG is a hardware-based high-performance Random Number Generator capable of generating 200 Mbit/s or more of true random numbers. The device harvests entropy from fluctuations in an optical source that arise from quantum mechanical properties of light. These quantum effects are irreducibly random; the resulting numbers are unpredictable and beyond the influence of any adversary. Qrypt, Inc., launched in 2017, has amassed multiple quantum entropy sources to create high-quality random keys at scale. The company is engaging with Los Alamos through license and a Cooperative Research and Development Agreement to facilitate the transition of QRNG technology and deploy the technology into the marketplace.

97 MATHEMATICS AND COMPUTING↗