Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Defect detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Assessment and Usage of In-Situ Monitoring Data for American Society of Mechanical Engineers Part Qualification

In-situ monitoring and anomaly detection are important components for qualification of directed energy deposition (DED) additive manufacturing (AM) processes and components. The use of in-situ monitoring requires an understanding of anomalies that can be identified during the process and how those anomalies correlate to mechanical properties of the component post-production. There is also a need to qualify the algorithms and software used to interpret the process signals for DED AM. There is no single process signal that can be used with a single algorithm that will identify all anomalies that will translate to a defect in a process. The process signals are affected by changes in material, location, resolution, acquisition rate, component geometry, and the machine itself. It is observed that multiple process signals are required to identify relevant features that can be correlated to mechanical properties.

36 MATERIALS SCIENCE↗

Mutational analysis of photosystem I polypeptides in the cyanobacterium Synechocystis sp. PCC 6803. Targeted inactivation of psaI reveals the function of psaI in the structural organization of psaL

We cloned, characterized, and inactivated the psaI gene encoding a 4-kDa hydrophobic subunit of photosystem I from the cyanobacterium Synechocystis sp. PCC 6803. The psaI gene is located 90 base pairs downstream from psaL, and is transcribed on 0.94- and 0.32-kilobase transcripts. To identify the function of PsaI, we generated a cyanobacterial strain in which psaI has been interrupted by a gene for chloramphenicol resistance. The wild-type and the mutant cells showed comparable rates of photoautotrophic growth at 25 degrees C. However, the mutant cells grew slower and contained less chlorophyll than the wild-type cells, when grown at 40 degrees C. The PsaI-less membranes from cells grown at either temperature showed a small decrease in NADP+ photoreduction rate when compared to the wild-type membranes. Inactivation of psaI led to an 80% decrease in the PsaL level in the photosynthetic membranes and to a complete loss of PsaL in the purified photosystem I preparations, but had little effect on the accumulation of other photosystem I subunits. Upon solubilization with nonionic detergents, photosystem I trimers could be obtained from the wild-type, but not from the PsaI-less membranes. The PsaI-less photosystem I monomers did not contain detectable levels of PsaL. Therefore, a structural interaction between PsaL and PsaI may stabilize the association of PsaL with the photosystem I core. PsaL in the wild-type and PsaI-less membranes showed equal resistance to removal by chaotropic agents. However, PsaL in the PsaI-less strain exhibited an increased susceptibility to proteolysis. From these data, we conclude that PsaI has a crucial role in aiding normal structural organization of PsaL within the photosystem I complex and the absence of PsaI alters PsaL organization, leading to a small, but physiologically significant, defect in photosystem I function.

NASA Discipline Cell Biology↗

Carbon nanospikes have improved sensitivity and antifouling properties for adenosine, hydrogen peroxide, and histamine

Carbon nanospikes (CNSs) are a new nanomaterial that has enhanced surface roughness and surface oxide concentration, increasing the sensitivity for dopamine detection. However, CNS-modified electrodes (CNSMEs) have not been characterized for other neurochemicals, particularly those with higher oxidation potentials. The purpose of this study was to evaluate CNSMEs for the detection of adenosine, hydrogen peroxide (H 2 O 2 ), and histamine. The sensitivity increased with CNSs, and signals at CNSMEs were about 3.3 times higher than CFMEs. Normalizing for surface area differences using background currents, CNSMEs show an increased signal of 4.8 times for adenosine, 1.5 times for H 2 O 2 , and 2 times for histamine. CNSMEs promoted the formation of secondary products for adenosine and histamine, which enables differentiation from other analytes with similar oxidation potentials. Furthermore, CNSs also selectively enhance the sensitivity for adenosine and histamine compared to H 2 O 2 . A scan rate test reveals that adenosine is more adsorption-controlled at CNS electrodes than CFMEs. CNSMEs are antifouling for histamine, with less fouling because the polymers formed after histamine electrooxidation do not adsorb due to an elevated number of edge planes. CNSMEs were useful for detecting each analyte applied in brain slices. Because of the hydrophilic surface compared to CFMEs, CNSMEs also have reduced biofouling when used in tissue. Therefore, CNSMEs are useful for tissue measurements of adenosine, hydrogen peroxide, and histamine with high selectivity and low fouling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Specialized diamond materials for NMR applications

Polarizable diamond materials and methods for obtaining nuclear magnetic resonance spectra of samples external to the diamond materials are described. The diamond materials can include 12C, 13C, substitutional nitrogen, and nitrogen vacancy defects in a crystalline lattice, wherein the substitutional nitrogen concentration is between 10 ppm and 200 ppm, the nitrogen vacancy concentration is between 10 ppb and 10 ppm, and the 13C concentration is greater than 1.1% and not more than 25%. Methods for obtaining nuclear magnetic resonance spectra can include optically pumping a diamond material to generate electron spin hyperpolarization in nitrogen vacancy centers, transferring the electron spin hyperpolarization to nuclei of the sample, and generating a nuclear magnetic resonance spectrum by applying a magnetic field to the sample, exciting the sample with a radio frequency pulse, and detecting a nuclear magnetic resonance response from the sample.

Parker, Alfred↗

Spectroscopic investigation of historical uranium glasses

Here, we present spectroscopic investigations of uranium in two historical glasses. A 1920's-1930's Art Deco (Bagley Carnival) green soda-lime-silica uranium glass bowl and a 1930's-1940's (Thomas Webb) yellow full lead crystal uranium glass vase were studied using optical absorption spectroscopy, XRF and SEM-EDX, X-band EPR and High- Energy Resolution Fluorescence-Detected (HERFD)-XANES. Uranium speciation may be different in the two glasses. Uranium occurs as uranyl groups (UO 2 2+ ) with minority reduced uranium species, mostly as U(V), more important in the Webb glass than in the Bagley glass. The differences between the two glasses arise from the fining procedure and result from the presence of other multivalent elements and differences in base glass composition. Electron Paramagnetic Resonance (EPR) spectra show the presence of an incipient signal close to g~2, partially annealed by heating to 550 °C, which we assign to a small concentration of radiation-induced defects caused by uranium decay. The presence of multivalent glass components in addition to U (As + Cu + Fe in the Bagley glass and Sb + Fe in the Webb glass) can trap the electron-hole pairs generated by the presence of uranium. This may explain the weakness of this signal in these glasses that anyway received a limited radiation dose since their fabrication. The low activity of these glasses, close to the background radiation, confirms that there is no danger to exhibiting them in museums.

36 MATERIALS SCIENCE↗

Role of deep levels and barrier height lowering in current-flow mechanism in 150 μ m thick epitaxial n-type 4H–SiC Schottky barrier radiation detectors

Schottky barrier detectors (SBDs) require larger surface areas than conventional electronics to increase the detection efficiency although such SBDs manifest large diode ideality factors due to inhomogeneous areal distribution of surface barrier height (SBH). Inhomogeneous SBH distributions lead to various current flow mechanisms in SBDs, which need to be identified to optimize detector performance. In this Letter, we identify the current flow mechanism in large area Schottky barrier diodes for radiation detection fabricated on 150 μm thick n-4H–SiC epitaxial layers. The analysis of temperature-dependent forward current–voltage (I–V–T) characteristics of SBDs revealed two linear regions in current–voltage curves up to 450 K, one corresponding to the current flow through a low barrier patch, while the other corresponds to that of average barrier distribution. Applying a SBH distribution model to the reverse I–V–T characteristics, an activation energy of 0.76 eV for the current flow over the Schottky barrier was calculated. Additionally, the activation energy did not directly correspond to any of the defect levels observed from the deep level transient spectroscopy (DLTS). Above 450 K, a Schottky type barrier lowering suggested a current flow through a low barrier patch of ≈ 0.8 eV. The absence of any SBH lowering below 450 K indicated that the current corresponded to a neutrally charged trap level at ≈ 0.6 eV below the conduction band edge, which was consistent with DLTS measurements revealing the presence of an electron trap level Z1/2 at 0.59 eV below the conduction band edge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Analysis of faults detected in a large-scale multi-version software development experiment

In a multiversion software experiment, twenty programs were built to the same specification of an inertial navigation problem. The programs were then subjected to a three-phase testing and debugging process: an acceptance test, a certification test, and an operational test. Less than 20 percent of the faults discovered during the certification and operational testing were nonunique, i.e., the same or very similar faults would be found in more than one program. However, some of these common faults spanned as many as half of the versions. Faults discovered during the certification testing were due to specification errors and ambiguities, inadequate programmer background knowledge, insufficient programming experience, incomplete analysis, and insufficient acceptance testing. Faults discovered during the operational testing were of a more subtle nature, and were mostly due to various programmer knowledge defects and incomplete analysis errors. Techniques that might have prevented the observed faults are discussed.

Vouk, Mladen A.↗

Improving qubit coherence time through detailed materials analysis

This study investigates the defects, imperfections, and variations in superconducting Nb thin films deposited on sapphire substrates. Two samples, W114 and W118, were fabricated using DC Magnetron Sputtering and Electron Cyclotron Resonance (ECR), respectively. Each sample was analyzed at five distinct spots to compare elemental homogeneity and thickness variations. Scanning Electron Microscopy (SEM) was employed to examine surface morphology, while Energy Dispersive X-ray Spectroscopy (EDS) and X-ray Photoelectron Spectroscopy (XPS) provided elemental and chemical state analyses. SEM revealed distinct structures in W114 and a uniform surface in W118. EDS showed higher aluminum and oxygen signals in W118, indicating a thicker film. XPS detected a higher Nb₂O₅ signal in W118, attributed to a thicker oxygen layer. These findings highlight the critical role of precise material characterization in advancing quantum computing technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

Hydrogen in Martian Meteorites

Most volatile studies of Mars have targeted its surface via spacecraft and rover data, and have evidenced surficial water in polar caps and the atmosphere, in the presence of river channels, and in the detection of water bearing minerals. The other focus of Martian volatile studies has been on Martian meteorites which are all from its crust. Most of these studies are on hydrous phases like apatite, a late-stage phase, i.e. crystallizing near the end of the differentiation sequence of Martian basalts and cumulates. Moreover, calculating the water content of the magma a phosphate crystallized from is not always possible, and yet is an essential step to estimate how much water was present in a parent magma and its source. Water, however, is primarily dissolved in the interiors of differentiated planets as hydrogen in lattice defects of nominally anhydrous minerals (olivine, pyroxene, feldspar) of the crust and mantle. This hydrogen has tremendous influence, even in trace quantities, on a planet's formation, geodynamics, cooling history and the origin of its volcanism and atmosphere as well as its potential for life. Studies of hydrogen in nominally anhydrous phases of Martian meteorites are rare. Measuring water contents and hydrogen isotopes in well-characterized nominally anhydrous minerals of Martian meteorites is the goal of our study. Our work aims at deciphering what influences the distribution and origin of hydrogen in Martian minerals, such as source, differentiation, degassing and shock.

Peslier, A. H.↗

SEL's Software Process-Improvement Program

The goals and operations of the Software Engineering Laboratory (SEL) is reviewed. For nearly 20 years the SEL has worked to understand, assess, and improve software and the development process within the production environment of the Flight Dynamics Division (FDD) of NASA's Goddard Space Flight Center. The SEL was established in 1976 with the goals of reducing: (1) the defect rate of delivered software, (2) the cost of software to support flight projects, and (3) the average time to produce mission-support software. After studying over 125 projects of FDD, the results have guided the standards, management practices, technologies, and the training within the division. The results of the studies have been a 75 percent reduction in defects, a 50 percent reduction in cost, and a 25 percent reduction in development time. Over time the goals of SEL have been clarified. The goals are now stated as: (1) Understand baseline processes and product characteristics, (2) Assess improvements that have been incorporated into the development projects, (3) Package and infuse improvements into the standard SEL process. The SEL improvement goal is to demonstrate continual improvement of the software process by carrying out analysis, measurement and feedback to projects with in the FDD environment. The SEL supports the understanding of the process by study of several processes including, the effort distribution, and error detection rates. The SEL assesses and refines the processes. Once the assessment and refinement of a process is completed, the SEL packages the process by capturing the process in standards, tools and training.

Basili, Victor↗

Focal adhesion kinase is involved in mechanosensing during fibroblast migration

Focal adhesion kinase (FAK) is a non-receptor protein tyrosine kinase localized at focal adhesions and is believed to mediate adhesion-stimulated effects. Although ablation of FAK impairs cell movement, it is not clear whether FAK might be involved in the guidance of cell migration, a role consistent with its putative regulatory function. We have transfected FAK-null fibroblasts with FAK gene under the control of the tetracycline repression system. Cells were cultured on flexible polyacrylamide substrates for the detection of traction forces and the application of mechanical stimulation. Compared with control cells expressing wild-type FAK, FAK-null cells showed a decrease in migration speed and directional persistence. In addition, whereas FAK-expressing cells responded to exerted forces by reorienting their movements and forming prominent focal adhesions, FAK-null cells failed to show such responses. Furthermore, FAK-null cells showed impaired responses to decreases in substrate flexibility, which causes control cells to generate weaker traction forces and migrate away from soft substrates. Cells expressing Y397F FAK, which cannot be phosphorylated at a key tyrosine site, showed similar defects in migration pattern and force-induced reorientation as did FAK-null cells. However, other aspects of F397-FAK cells, including the responses to substrate flexibility and the amplification of focal adhesions upon mechanical stimulation, were similar to that of control cells. Our results suggest that FAK plays an important role in the response of migrating cells to mechanical input. In addition, phosphorylation at Tyr-397 is required for some, but not all, of the functions of FAK in cell migration.

NASA Discipline Cell Biology↗

Ligand assisted growth of perovskite single crystals with low defect density

A low defect density in metal halide perovskite single crystals is critical to achieve high performance optoelectronic devices. Here we show the reduction of defect density in perovskite single crystals grown by a ligand-assisted solution process with 3-(decyldimethylammonio)-propane-sulfonate inner salt (DPSI) as an additive. DPSI ligands anchoring with lead ions on perovskite crystal surfaces not only suppress nucleation in solution, but also regulate the addition of proper ions to the growing surface, which greatly enhances the crystal quality. The grown CH 3 NH 3 PbI 3 crystals show better crystallinity and a 23-fold smaller trap density of 7 × 10 10 cm -3 than the optimized control crystals. The enhanced material properties result in significantly suppressed ion migration and superior X-ray detection sensitivity of CH 3 NH 3 PbI 3 detectors of (2.6 ± 0.4) × 10 6 µC Gy -1 air cm -2 for 60 kVp X-ray and the lowest detectable dose rate reaches (5.0 ± 0.7) nGy s -1 , which enables reduced radiation dose to patients in medical X-ray diagnostics.

36 MATERIALS SCIENCE↗

Exep: Environmental Testing of High-Actuator-Count Mems Deformable Mirrors for Space-Based Applications

Coronagraph instruments on future space telescopes will rely on deformable mirrors to create high contrast images for the direct detection of exoplanets. As part of the NASA Exoplanet Explorations Program’s coronagraph technology development efforts, two sets of Micro-electro-mechanical systems (MEMS) deformable mirrors manufactured by Boston Micromachines Corporation were exposed to vibration and thermal cycles representative of launch conditions. The first set were 952-actuator Kilo-DMs that successfully demonstrated 100% actuator survival and achieved ~1e-8 contrast after the environment test. The second round used an engineering-grade 2048-actuator deformable mirror on which few changes were identified after the environmental test. However, each actuator that changed behavior was flagged as anomalous beforehand or was directly adjacent to a defective actuator. From this result, we hypothesized that typical actuators on a science grade deformable mirror are robust to environmental testing. A third set of 2048-actuator deformable mirror have been procured for a planned test to characterize the deformable mirrors using interferometric measurements, contrast results on a new in-air coronagraph testbed, and infrared microscopy on the internal structure of the MEMS devices.

Lam, Charlie↗

Improving Qubit Coherence Time Through Detailed Materials Analysis

This study investigates the defects, imperfections, and variations in Nb thin films deposited on sapphire substrates. Two samples, W114 and W118, were fabricated using DC Magnetron Sputtering and Electron Cyclotron Resonance (ECR), respectively. Each sample was analyzed at five distinct spots to compare elemental homogeneity and variations in oxide layers. Scanning Electron Microscopy (SEM) was employed to examine surface morphology, while Energy Dispersive X-ray Spectroscopy (EDS) and X-ray Photoelectron Spectroscopy (XPS) provided elemental and chemical state analyses. SEM revealed distinct structures in W114 and a uniform surface in W118. EDS showed higher aluminum signals in W118, indicating a thinner film in comparison to W114. XPS detected a higher Nb₂O₅ signal in W118, in comparison to W114, which can be attributed to the presence of a thicker Nb₂O₅ layer in W118. These findings highlight the critical role of precise material characterization in advancing quantum computing technologies.

Rosado Bonilla, Cristy M.↗