Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Anodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Kinetics and thermodynamics of chemical reactions in Li/SOCl2 cells

Work is described that was designed to determine the kinetic constants necessary to extrapolate kinetic data on Li/SOCl2 cells over the temperature range from 25 to 75 C. A second objective was to characterize as far as possible the chemical reactions that occur in the cells since these reactions may be important in understanding the potential hazards of these cells. The kinetics of the corrosion processes in undischarged Li/SOCl2 cells were determined and separated according to their occurrence at the anode and cathode; the effects that switching the current on and off has on the corrosion reactions was determined; and the effects of discharge state on the kinetics of the corrosion process were found. A thermodynamic analysis of the current-producing reactions in the cell was done and is included.

Hansen, Lee D.↗

Hollow cathode-based plasma contactor experiments for electrodynamic tether

The role plasma contactors play in effective electrodynamic tether operation is discussed. Hollow cathodes and hollow cathode-based plasma sources have been identified as leading candidates for the electrodynamic tether plasma contactor. Present experimental efforts to evaluate the suitability of these devices as plasma contactors are reviewed. This research includes the definition of preliminary plasma contactor designs, and the characterization of their operation as electron collectors from a simulated space plasma. The discovery of an 'ignited mode' regime of high contactor efficiency and low impedance is discussed, as well as is the application of recent models of the plasma coupling process to contactor operation. Results indicate that ampere-level electron currents can be exchanged between hollow cathode-based plasma contactors and a dilute plasma in this regime. A discussion of design considerations for plasma contactors is given which includes expressions defining the total mass flow rate and power requirements of plasma contactors operating in both the cathodic and anodic regimes, and correlation of this to the tether current. Finally, future ground and spaceflight experiments are proposed to resolve critical issues of plasma contactor operation.

Patterson, Michael J.↗

Advanced technology for extended endurance alkaline fuel cells

Advanced components have been developed for alkaline fuel cells with a view to the satisfaction of NASA Space Station design requirements for extended endurance. The components include a platinum-on-carbon catalyst anode, a potassium titanate-bonded electrolyte matrix, a lightweight graphite electrolyte reservoir plate, a gold-plated nickel-perforated foil electrode substrate, a polyphenylene sulfide cell edge frame material, and a nonmagnesium cooler concept. When incorporated into the alkaline fuel cell unit, these components are expected to yield regenerative operation in a low earth orbit Space Station with a design life greater than 5 years.

Sheibley, D. W.↗

Surface characterization of InP using photoluminescence

Photoluminescence (PL) measurements have been performed on InP samples in situ during various surface treatments including chemical etching, wet anodization, and low-pressure chemical vapor deposition. It was found, in agreement with previously published results, that the magnitude of the PL signal varies markedly with surface treatment due presumably to changes in either surface-state density, and/or surface potential. In an attempt to assess the effectiveness of this noninvasive method as a tool for characterizing and monitoring the progressive development of a semiconductor surface during processing, a number of experiments on InP have been performed. The results indicate that although some uncertainty may exist in assigning a mechanism for the PL change in any given experiment, the general trend appears to be that surface degradation results in a reduced signal. As a result, process steps which enhance the PL intensity are likely to be beneficial in the preparation of a high-quality interface.

Chang, R. R.↗

MPD thruster scaling

Full scale and half scale versions of the Princeton Benchmark and Flared Anode self-field MPD thrusters have been investigated to determine the influence of scale and design upon MPD behavior. Thruster performance determined by impulsive thrust and terminal voltage measurements is found to depend primarily on propellant flow rate and the ratio of electrode radii, but not on thruster size. Current distributions obtained from magnetic field probes are independent of scale for both thruster designs. Voltage depends upon current, electrode geometry, and propellant flow rate. This behavior agrees qualitatively with calculations based on a fundamental MHD formulation.

Kelly, A. J.↗

Hollow cathodes for arcjet thrusters

In an attempt to prevent exterior spot emission, hollow cathode bodies and orifice plates were constructed from boron nitride which is an electrical insulator, but the orifice plates melted and/or eroded at high interelectrode pressures. The most suitable hollow cathodes tested included a refractory metal orifice plate in a boron nitride body, with the insert insulated electrically from the orifice plate. In addition, the hollow cathode interior was evacuated to assure a low pressure at the insert surface, thus promoting diffuse electron emission. At high interelectrode pressures, the electrons tended to flow through the orifice plate rather than through the orifice, which could result in overheating of the orifice plate. Using a carefully aligned centerline anode, electron flow through the orifice could be sustained at interelectrode pressures up to 500 torr - but the current flow path still occasionally jumped from the orifice to the orifice plate. Based on these tests, it appears that a hollow cathode would operate most effectively at pressures in the arcjet regime with a refractory, chemically stable, and electrically insulating cathode body and orifice plate.

Luebben, Craig R.↗

Electrothermal-electromagnetic hybrid thruster research

The energy deposition and acceleration mechanisms in the electrothermal-electromagnetic hybrid regime of coaxial plasma thruster operation are examined both theoretically and experimentally. Theoretical results show that the major trade-offs in the hybrid regime are between efficiency and specific impulse: increasing the influence of electromagnetic forces increases I(sp), but within the operating range examined, decreases the efficiency. Experiments conducted in the predominantly electromagnetic regime agree with the predictions. Anode power deposition is the dominant loss process.

Kelly, A. J.↗

Design and operation of a 100 kW subscale MPD engine

The design and operation of a subscale MPD device is described as part of a program to develop a multimegawatt engine. The device is used as a test bed for component development, primarily the cathode and anode. The first series of exploratory tests have been conducted and the engine has been operated for 8.5 hours in the steady state, over 74 runs, and at a power level as high as 72 kW. A diffuser based vacuum tank pumping scheme has been evaluated with the engine operating at 17 kW and shows a positive result.

King, D. Q.↗

Arcjet component conditions through a multistart test

A low power, dc arcjet thruster was tested for starting reliability using hydrogen-nitrogen mixtures simulating the decomposition products of hydrazine. More than 300 starts were accumulated in phases with extended burn-in periods interlaced. A high degree of flow stabilization was built into the arcjet and the power supply incorporated both rapid current regulation and a high voltage, pulsed starting circuit. A nominal current level of 10 A was maintained throughout the test. Photomicrographs of the cathode tip showed a rapid recession to a steady-state operating geometry. A target of 300 starts was selected, as this represents significantly more than anticipated (150 to 240), in missions of 10 yr or less duration. Weighings showed no apparent mass loss. Some anode erosion was observed, particularly at the entrance to the constrictor. This was attributed to the brief period during startup the arc mode attachment point spends in the high pressure region upstream of the nozzle. Based on the results obtained, startup does not appear to be performance or life limiting for the number of starts typical of operational satellite applications.

Curran, Frank M.↗

USBI Booster Production Company's Hazardous Waste Management Program at the Kennedy Space Center, FL

In response to the hazardous-waste generating processes associated with the launch of the Space Shuttle, a hazardous waste management plan has been developed. It includes waste recycling, product substitution, waste treatment, and waste minimization at the source. Waste material resulting from the preparation of the nonmotor segments of the solid rocket boosters include waste paints (primer, topcoats), waste solvents (methylene chloride, freon, acetone, toluene), waste inorganic compounds (aluminum anodizing compound, fixer), and others. Ways in which these materials are contended with at the Kennedy Space Center are discussed.

Venuto, Charles↗

Corrosion of graphite composites in phosphoric acid fuel cells

Polymers, polymer-graphite composites and different carbon materials are being considered for many of the fuel cell stack components. Exposure to concentrated phosphoric acid in the fuel cell environment and to high anodic potential results in corrosion. Relative corrosion rates of these materials, failure modes, plausible mechanisms of corrosion and methods for improvement of these materials are investigated.

Christner, L. G.↗

Hybrid X-ray telescope systems

It has been known for some time that glancing incidence X-ray optics have sharply peaked point response functions. The spatial resolution of Wolter X-ray telescope systems is frequently limited by the performance characteristics of the X-ray detector rather than by the optics, even when high resolution detectors such as photographic emulsions are used. This problem becomes even more severe when it is desirable to take advantage of the high sensitivity and broad wavelength response afforded by modern solid state detectors such as charge coupled devices or multi-anode microchannel arrays. Results of theoretical investigations of methods for increasing the telescope plate scale by the use of glancing incidence hyperboloid/ellipsoid X-ray microscope optics and normal incidence contoured layered synthetic microstructure optics for coupling the Wolter mirrors to the detector are reported. The relative merits of the different hybrid X-ray telescope systems which result will be discussed. Considerations will be made concerning applications of these systems to high resolution imagery and spectroscopy of astronomical X-ray/XUV sources.

Shealy, David L.↗

Pumping potential wells

Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electro collecting anode in a relatively cold, low density multidipole plasma is considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important.

Hershkowitz, N.↗

Enhanced current flow through a plasma cloud by induction of plasma turbulence

Electrodynamic tethers have been proposed as a means of generating power in low earth orbit. One of the limitations on the power generated is the relatively low electron current that can be collected. It is proposed that the electron current can be significantly enhanced by means of current-induced plasma turbulence in a plasma cloud around the collecting anode. This is examined for the specific case of ion acoustic turbulence. An important conclusion is that the use of plasma clouds in the ionosphere will entail a high-impedance (no instability) and a low-impedance (ion acoustic instability) mode of operation. The low-impedance mode of operation will have two submodes, one steady state and one pulsed.

Hastings, D. E.↗

The indirect electrochemical refining of lunar ores

Recent work performed on an electrolytic cell is reported which addresses the implicit limitations in various approaches to refining lunar ores. The cell uses an oxygen vacancy conducting stabilized zirconia solid electrolyte to effect separation between a molten salt catholyte compartment where alkali metals are deposited, and an oxygen-evolving anode of composition La(0.89)Sr(0.1)MnO3. The cell configuration is shown and discussed along with a polarization curve and a steady-state current-voltage curve. In a practical cell, cathodically deposited liquid lithium would be continuously removed from the electrolytic cell and used as a valuable reducing agent for ore refining under lunar conditions. Oxygen would be indirectly electrochemically extracted from lunar ores for breathing purposes.

Semkow, Krystyna W.↗

Computer simulation of two electrophoretic columns coupled for isoelectric focusing in simple buffers

Computer simulation is used to analyze a system of two electrophoretic columns coupled by mixing the anolyte of one with the catholyte of the other. A mathematical model is presented which is used to predict the pH gradients formed by monovalent buffers in this system, when the currents in the columns are unequal. In the column with the higher current a pH gradient is created which increases from anode to cathode and is potentially useful for isoelectric focusing. The breadth of this gradient is dependent upon the ratio of the currents. The function of the second column is the compensation of buffer migration which occurs in the first column, thereby maintaining constant electrolyte composition. The effects of buffer pKs and mobilities are evaluated.

Tsai, Amos↗

An explanation for the plateau phenomenon in isoelectric focusing

Isoelectric focusing of mixtures of simple ampholytes occurs in two phases, an initial rapid separation phase and a second relatively slow stabilizing phase. Transient and steady-state computer simulation data are shown to predict the development of pH plateaus around neutrality during the stabilizing phase of the focusing of such mixtures. This occurs because a nonzero electrophoretic flux is present in a pure zone of focused ampholyte, which is a function of both its isolectric point (pI) and its Delta-pK value. For an ampholyte with a pI greater than 9 or less than 5, this flux causes the development of a significant concentration gradient within its focused zone which is accompanied by a contraction of this zone along the focusing axis. Acidic and basic ampholytes are thereby displayed toward the anode and cathode respectively, creating a pH plateau in the neutral region. Thus, there will be regions of the focusing column, closer to the electrodes and containing more acidic or basic pH values, within which the resolution of samples will reach a maximum and then decrease.

Mosher, Richard A.↗

Dual-Cathode Electron-Beam Source

Beam from either cathode electromagnetically aligned with exit port. Electron beam from either of two cathodes deflected by magnetic and electric fields to central axis. Mechanical alignment of beam easy because cathode axes, anode apertures, and electron trajectories coplanar. Applications where uninterrupted service needed: scanning electron microscopes, transmission electron microscopes, electron-beam lithography equipment, Auger instruments, and microfocused x-ray sources.

Bradley, James G.↗