Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conclusions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Toward real-time optimization through model reduction and model discrepancy sensitivities

Optimization problems arise in a range of scenarios, from optimal control to model parameter estimation. In many applications, such as the development of digital twins, it is essential to solve these optimization problems within wall-clock-time limitations. However, this is often unattainable for complex systems, such as those modeled by nonlinear partial differential equations. One strategy for mitigating this issue is to construct a reduced-order model (ROM) that enables more rapid optimization. In particular, the use of nonintrusive ROMs—those that do not require access to the full-order model at evaluation time—is popular because they facilitate the computation of optimization solutions within the wall-clock time requirements. However, the optimization solution will be unreliable if the iterates move outside the ROM training data. This article proposes the use of hyper-differential sensitivity analysis with respect to model discrepancy (HDSA-MD) as a computationally efficient tool to augment ROM-constrained optimization and improve its reliability. The proposed approach consists of two phases: (i) an offline phase where several full-order model evaluations are computed to train the ROM, and (ii) an online phase where a ROM-constrained optimization problem is solved, a limited number of full-order model evaluations are computed, and HDSA-MD is used to enhance the optimization solution. Numerical results are demonstrated for two examples, atmospheric contaminant control and wildfire ignition location estimation, in which a ROM is trained offline using inaccurate atmospheric data. In conclusion, the HDSA-MD update yields a significant improvement in the ROM-constrained optimization solution using only one full-order model evaluation online with corrected atmospheric data.

PDE-constrained optimization↗

Integration of polyurethane meniscus scaffold during ACL revision is not reliable at 5 years despite favourable clinical outcome

Abstract Purpose The aim of this study was to evaluate the clinical outcome at 5‐year follow‐up of a one‐step procedure combining anterior cruciate ligament (ACL) reconstruction and partial meniscus replacement using a polyurethane scaffold for the treatment of symptomatic patients with previously failed ACL reconstruction and partial medial meniscectomy. Moreover, the implanted scaffolds have been evaluated by MRI protocol in terms of morphology, volume, and signal intensity. Methods Twenty patients with symptomatic knee laxity after failed ACL reconstruction and partial medial meniscectomy underwent ACL revision combined with polyurethane‐based meniscal scaffold implant. Clinical assessment at 2‐ and 5‐year follow‐ups included VAS, Tegner Activity Score, International Knee Documentation Committee (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm Score. MRI evaluation of the scaffold was performed according to the Genovese scale with quantification of the scaffold’s volume at 1‐ and 5‐year follow‐ups. Results All scores revealed clinical improvement as compared with the preoperative values at the 2‐ and 5‐year follow‐ups. However, a slight, but significant reduction of scores was observed between 2 and 5 years. Concerning the MRI assessment, a significant reduction of the scaffold’s volume was observed between 1 and 5 years. Genovese Morphology classification at 5 years included two complete resorptions (Type 3) and all the remaining patients had irregular morphology (Type 2). With regard to the Genovese Signal at the 5‐year follow‐up, three were classified as markedly hyperintense (Type 1), 15 as slightly hyperintense (Type 2), and two as isointense (Type 1). Conclusion Simultaneous ACL reconstruction and partial meniscus replacement using a polyurethane scaffold provides favourable clinical outcomes in the treatment of symptomatic patients with previously failed ACL reconstruction and partial medial meniscectomy at 5 years. However, MRI evaluation suggests that integration of the scaffold is not consistent. Level of evidence Level IV.

Pereira, Hélder↗

Extent of interlocking and metallurgical bonding in friction riveting of aluminum alloy to steel

In this study, the joining of 6061-T6 aluminum alloy and DP590 steel using a M42 steel rivet via friction riveting technique is investigated. The surface morphology and microstructure characterization reveal the formation of an anchor zone that imparts mechanical interlock as well as the formation of metallurgical bonds at the interface of aluminum and steel. A combination of interlocking and bonding results in the achievement of a high load-carrying capacity of 5.7 kN during lap shear testing at room temperature. A finite element-based computational model was developed which accurately predicted the lap shear response of the joint. The model revealed that the metallurgical bond formed during fric-riveting adds 39% peak load strength to the joint. An extensive microstructural investigation, post-lap-shear fractography, and the modeling results, together provided insights on the joint failure mechanism. In conclusion, this study highlights that friction riveting is a promising method for aluminum-to-steel dissimilar joining, which is important for lighweighing automotive vehicles for energy efficiency.

36 MATERIALS SCIENCE↗

Reinforcement learning for real-time process control in high-temperature superconductor manufacturing

With high efficiency and low energy loss, high-temperature superconductors (HTS) have demonstrated their profound applications in various fields, such as medical imaging, transportation, accelerators, microwave devices, and power systems. The high-field applications of HTS tapes have raised the demand for producing cost-effective tapes with long lengths in superconductor manufacturing. However, achieving the uniform and enhanced performance of a long HTS tape is challenging due to the unstable growth conditions in the manufacturing process. Although it is confirmed that the process parameters during the advanced metal organic chemical vapor deposition (A-MOCVD) process influence the uniformity of the produced HTS tapes, the high-dimensional process parameter signals and their complicated interactions make it difficult to develop an effective control policy. In this paper, we propose a local measure for the uniformity of HTS tapes to provide instant feedback for our control policy. Then, we model the manufacturing of HTS tapes as a Markov decision process (MDP) with continuous state and action spaces to assess the instant reward in real time in our feedback control model. As our MDP involves continuous and high-dimensional state and action spaces, a neural fitted Q-iteration (NFQ) algorithm is adopted to solve the MDP with artificial neural network (ANN) function approximation. The collinearity of process parameters can restrict our capability of adjusting the process parameters, which is addressed by the principal component analysis (PCA) in our method. The control policy adjusts the PCA of process parameters using the NFQ algorithm. In conclusion, based on our case studies on real A-MOCVD dataset, the obtained control policy increases the average uniformity of tapes by 5.6% and performs especially well on sample HTS tapes with a low uniformity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A data-driven framework for predicting machining stability: employing simulated data, operational modal analysis, and enhanced transfer learning

Chatter, a self-excited vibration phenomenon, presents a significant challenge in machining operations, particularly in high-speed milling, where it can degrade tool life, reduce material removal efficiency, and compromise workpiece quality. Addressing this challenge requires a reliable predictive model that can accommodate the complex dynamics of various machining scenarios. This study introduces a novel, data-driven approach to predicting machining stability, leveraging over 140,000 simulated datasets and employing advanced techniques such as operational modal analysis (OMA), enhanced transfer learning (TL), and receptance coupling substructure analysis (RCSA). By integrating these methodologies, the framework effectively classifies and predicts chatter across diverse operational modes, achieving robust and accurate outcomes. Our model utilizes a Random Forest (RF) classifier trained with the comprehensive dataset, which demonstrates substantial improvements in both predictive accuracy and robustness. Specifically, the RF model achieved an accuracy rate of 85%, an area under the curve (AUC) of 0.90, and an F1 score of 0.88, underscoring its capability to adapt to varying machining configurations. These results highlight the framework’s potential to enhance operational efficiency and machining quality by providing reliable chatter predictions across a broad range of machining parameters. In conclusion, this research thus offers a significant advancement in predictive maintenance for machining processes, enabling more stable and efficient manufacturing operations.

42 ENGINEERING↗

Autonomous direct freeform fabrication strategy for multi-axis additive manufacturing

Multi-axis additive manufacturing (M-AM) enables precise material deposition along both planar and curved layers, eliminating the need for support structures through a continuous material deposition approach. In contrast to conventional 2-dimensional planar layers constrained to a fixed building orientation, the deposition on freeform layers demands the specification of guided curves to determine material deposition directions which are no longer to be fixed to a build direction. There are challenges that arise when fabricating components with multiple “build” directions, necessitating the decomposition of geometries and the specification of guided curves for the resulting volumes. Furthermore, multi-axis systems introduce heightened challenges due to an increased degree of freedom in motion. Consequently, the potential risks of collision between the deposited geometry and the motion platform become a notable concern. This research proposes a freeform layering algorithm to address the challenge of seamless transitions between planar and curved layers in the process planning of M-AM. The algorithm computes 3D “printable” layers by leveraging topological information derived from the geometry to be built and integrates collision-free manufacturability considerations into the computational process. These accumulated volumes serve as a “substrate” and support volumes for subsequent deposition, allowing later layers to be built without the need for additional support material. In conclusion, the proposed method successfully devises a freeform layering approach suitable for intricate models that demand substantial support, thus enabling the fabrication of diverse geometries in a manner previously unachievable.

36 MATERIALS SCIENCE↗

Fatigue behavior of low-cost, non-spherical Ti-6Al-4V powder processed via laser powder bed fusion

Hydride-dehydride Ti-6Al-4V powder with particle size distribution of 75–175 μm were used to manufacture fatigue samples. Optimized processing parameters were used to maintain a relative density of >99.5% in the samples. Fatigue tests were carried out in R = σ min /σ max = -1 condition under stresses ranging from 150 to 500 MPa and the results were compared to samples that were additively manufactured using spherical powders. The fatigue lives were similar between the two types of powder; i.e., powder morphology has no effect on fatigue performance. However, the high surface roughness and martensitic microstructure resulting from the laser powder bed fusion process result in poor performance compared to samples machined from conventionally produced materials. In conclusion, crack initiation occurred consistently from surface defects because of high surface roughness of the additively manufactured parts.

36 MATERIALS SCIENCE↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Isolation and characterization of lignocellulosic nanofibers from four kinds of organosolv-fractionated lignocellulosic materials

The objective of this research was to investigate the presence of residual lignin in cellulose fibers on the efficiency and energy consumption during nanofibers processing. Four kinds of lignin-containing cellulose nanofibers (LCNFs) from switchgrass, yellow poplar, hybrid poplar, and pine, respectively, were isolated via organosolv fractionation coupling mechanical grinding. Nanofibrils were observed after organosolv fractionation. The details of their morphological features, chemical structures, water retention value (WRV), and thermal degradation characteristics were revealed and compared. Mean diameters of nanofibers separated from switchgrass, yellow poplar, hybrid poplar, and pine were 27.9 nm, 25.4 nm, 24.6 nm, and 21.5 nm, respectively. The presence of lignin for the four types of LCNFs led to a decrease in energy consumption and an increase in WRV, among which pine nanofibers show the best with an average energy consumption of 0.511 kWh/kg and a WRV of 537%. It was also demonstrated that increasing lignin content for LCNFs could contribute to the sample’s thermal stability. In conclusion, exact benefits of residual lignin for nanofiber will facilitate its preparation process and extend its application.

36 MATERIALS SCIENCE↗

Aggregation and analysis of indication-symptom relationships for drugs approved in the USA

Abstract Purpose Drug indications and disease symptoms often confound adverse event reports in real-world datasets, including electronic health records and reports in the FDA Adverse Event Reporting System (FAERS). A thorough, standardized set of indications and symptoms is needed to identify these confounders in such datasets for drug research and safety assessment. The aim of this study is to create a comprehensive list of drug-indication associations and disease-symptom associations using multiple resources, including existing databases and natural language processing. Methods Drug indications for drugs approved in the USA were extracted from two databases, RxNorm and Side Effect Resource (SIDER). Symptoms for these indications were extracted from MedlinePlus and using natural language processing from PubMed abstracts. Results A total of 1361 unique drugs, 1656 unique indications, and 2201 unique symptoms were extracted from a wide variety of MedDRA System Organ Classes. Text-mining precision was maximized at 0.65 by examining Term Frequency Inverse Document Frequency (TF-IDF) scores of the disease-symptom associations. Conclusion The drug-indication associations and disease-symptom associations collected in this study may be useful in identifying confounders in other datasets, such as safety reports. With further refinement and additional drugs, indications, and symptoms, this dataset may become a quality resource for disease symptoms.

Punyala, Ananth↗

The impact of demographic, clinical, genetic, and imaging variables on tau PET status

Purpose: A substantial proportion of amyloid-β (Aβ)+ patients with clinically diagnosed Alzheimer’s disease (AD) dementia and mild cognitive impairment (MCI) are tau PET–negative, while some clinically diagnosed non-AD neurodegenerative disorder (non-AD) patients or cognitively unimpaired (CU) subjects are tau PET–positive. We investigated which demographic, clinical, genetic, and imaging variables contributed to tau PET status. Methods: We included 2338 participants (430 Aβ+ AD dementia, 381 Aβ+ MCI, 370 non-AD, and 1157 CU) who underwent [ 18 F]flortaucipir ( n = 1944) or [ 18 F]RO948 ( n = 719) PET. Tau PET positivity was determined in the entorhinal cortex, temporal meta-ROI, and Braak V-VI regions using previously established cutoffs. We performed bivariate binary logistic regression models with tau PET status (positive/negative) as dependent variable and age, sex, APOE ε4, Aβ status (only in CU and non-AD analyses), MMSE, global white matter hyperintensities (WMH), and AD-signature cortical thickness as predictors. Additionally, we performed multivariable binary logistic regression models to account for all other predictors in the same model. Results: Tau PET positivity in the temporal meta-ROI was 88.6% for AD dementia, 46.5% for MCI, 9.5% for non-AD, and 6.1% for CU. Among Aβ+ participants with AD dementia and MCI, lower age, MMSE score, and AD-signature cortical thickness showed the strongest associations with tau PET positivity. In non-AD and CU participants, presence of Aβ was the strongest predictor of a positive tau PET scan. Conclusion: We identified several demographic, clinical, and neurobiological factors that are important to explain the variance in tau PET retention observed across the AD pathological continuum, non-AD neurodegenerative disorders, and cognitively unimpaired persons.

60 APPLIED LIFE SCIENCES↗

What a difference a delay makes! CT urogram: a pictorial essay

Purpose: The aim of this pictorial essay is to demonstrate several cases where the diagnosis would have been difficult or impossible without the excretory phase image of CT urography. Methods: A brief discussion of CT urography technique and dose reduction is followed by several cases illustrating the utility of CT urography. Results: CT urography has become the primary imaging modality for evaluation of hematuria, as well as in the staging and surveillance of urinary tract malignancies. CT urography includes a non-contrast phase and contrast-enhanced nephrographic and excretory (delayed) phases. While the three phases add to the diagnostic ability of CT urography, it also adds potential patient radiation dose. Several techniques including automatic exposure control, iterative reconstruction algorithms, higher noise tolerance, and split-bolus have been successfully used to mitigate dose. The excretory phase is timed such that the excreted contrast opacifies the urinary collecting system and allows for greater detection of filling defects or other abnormalities. Sixteen cases illustrating the utility of excretory phase imaging are reviewed. Conclusions: Excretory phase imaging of CT urography can be an essential tool for detecting and appropriately characterizing urinary tract malignancies, renal papillary and medullary abnormalities, CT radiolucent stones, congenital abnormalities, certain chronic inflammatory conditions, and perinephric collections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT urography: how to optimize the technique

Purpose: Computed tomography urography (CTU) has emerged as the modality of choice for imaging the urinary tract within the past few decades. It is a powerful tool that enables detailed anatomic evaluation of the urinary tract in order to identify primary urothelial malignancies, benign urinary tract conditions, and associated abdominopelvic pathologies. As such, there have been extensive efforts to optimize CTU protocol. Methods: This article reviews the published literature on CTU protocol optimization, including contrast bolus timing, dose reduction, reconstruction algorithms, and ancillary practices. Conclusion: There have been many advances in CTU techniques, which allow for imaging diagnosis of a wide spectrum of diseases while minimizing radiation dose and maximizing urinary tract distension and opacification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality imaging of the male urethra: trauma, infection, neoplasm, and common surgical repairs

Objective: The aim of this article is to describe the indications and proper technique for RUG and MRI, their respective image findings in various disease states, and the common surgical techniques and imaging strategies employed for stricture correction. Results: Because of its length and passage through numerous anatomic structures, the adult male urethra can undergo a wide array of acquired maladies, including traumatic injury, infection, and neoplasm. For the urologist, imaging plays a crucial role in the diagnosis of these conditions, as well as complications such as stricture and fistula formation. While retrograde urethrography (RUG) and voiding cystourethrography (VCUG) have traditionally been the cornerstone of urethral imaging, MRI has become a useful adjunct particularly for the staging of suspected urethral neoplasm, visualization of complex posterior urethral fistulas, and problem solving for indeterminate findings at RUG. Conclusions: Familiarity with common urethral pathology, as well as its appearance on conventional urethrography and MRI, is crucial for the radiologist in order to guide the treating urologist in patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of pancreatic head ductal adenocarcinoma from inflammatory pancreatic pseudomass by MR cholangio-pancreatography: utility of the duct-interrupted, corona, and attraction signs

Purpose: To determine sensitivity and specificity of the “duct-interrupted,” “corona,” and “attraction” signs on MR cholangio-pancreatography (MRCP) in distinguishing pancreatic head ductal adenocarcinoma (PDAC) from inflammatory pancreatic pseudomass (IPP). Materials and methods: This study included 53 adults (33 men and 20 women, mean age, 55 years; range, 17–87 years) with a pancreatic head mass who underwent MRCP. Three blinded radiologists independently reviewed each MRCP exam and three signs were assessed: (1) the “duct-interrupted” sign, deemed positive for PDAC if the duct within the mass demonstrated complete interruption with upstream dilation; (2) the “corona” sign, considered positive for PDAC if dilated side-branches were located exclusively outside the mass; and (3) the “attraction” sign, deemed positive for IPP if the dilated common bile duct showed attraction and angulation towards the mass. Sensitivity, specificity, and positive and negative predictive values of the signs were calculated, as well as interobserver agreement. Results: Out of 53 masses, 17 (32%) were PDAC and 36 (68%) were IPP. Sensitivity, specificity, and positive and negative predictive values of the “duct-interrupted” sign to differentiate between PDAC from IPP for the three readers were 29–53%, 89–95%, 56–82% and 73–81%, respectively (κ = 0.41); for the “corona” sign, they were 29–53%, 81–100%, 56–100%, and 75–78%, respectively (κ = 0.4), and for the “attraction” sign, they were 20–25%, 71–82%, 64–75%, and 31–34%, respectively (κ = 0.54). Conclusion: The “duct-interrupted” and “corona” MRCP signs have high specificity for diagnosing PDAC, while the “attraction” sign has good specificity for identifying IPP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed tomography (CT) in the evaluation of bladder and ureteral trauma: indications, technique, and diagnosis

Introduction: Trauma to the genitourinary system includes blunt and penetrating injuries to bladder and ureters. These are rare injuries and are overlooked as other abdominal and pelvic injuries often take priority. Delayed diagnosis can lead to significant morbidity and mortality. Computed tomography has taken a central role in the imaging of the ureters and bladder. Methods: This article reviews the anatomic relationships, mechanisms of injury, and clinical presentation to help physicians determine when bladder and ureteral injuries should be suspected and further imaging should be pursued. Radiologic evaluation of bladder and ureteral injury with CT cystography and CT urography, respectively, will be reviewed. Conclusion: CT cystography and CT urography are effective tools in identifying potentially serious injuries to the genitourinary system. Timely recognition of these injuries can be crucial for the overall management and prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urinary diversions: a primer of the surgical techniques and imaging findings

Objective: The article attempts to describe the indications, classification, and surgical anatomy of the commonly performed urinary diversion procedures, followed by the imaging protocol and radiological appearances of the normal postoperative anatomy and complications related to these procedures. Contents: Diversion procedures are used to reroute urine after cystectomy and in patients with refractory neurogenic or outlet obstruction of the urinary bladder. Broadly, these can be classified as continent and incontinent diversions. Patients with urinary diversions frequently undergo radiological investigations for the detection of complications. Commonly, a loopogram or pouchogram is performed few weeks after the surgery to look for leak, whereas CT or MRI is used for long-term follow-up. Postoperative complications can be early (within 30 days of the surgery) or delayed and include leaks, collections, strictures, calculi, parastomal hernia, small bowel obstruction, and oncologic recurrence. Conclusion: A variety of urinary diversion procedures are commonly performed and interpretation of the postsurgical anatomy can be overwhelming for the general radiologist. This article provides a basic understanding of the normal anatomy as well as a thorough discussion on the imaging protocol and radiological appearances of the potential complications associated with these procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗