Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Crystalline-silicon photovoltaics summary module design and reliability

The evolution of the design and reliability of solar modules was described. Design requirements involved 14 different considerations, including residential building and material electrical codes, wind-loading, hail impact, operating temperature levels, module flammability, and interfaces for both the array structure and the operation of the system. Reliability research involved in diverse investigations including glass-fracture strength, soiling levels, electrochemical corrosion, and bypass-diode qualification tests. Based on these internationally recognized studies, performance assessments, and failure analyses, the Flat-plate Solar Array Project in its 11-year duration served to nuture the development of 45 different solar module designs from 15 PV manufacturers.

Ross, R. G., Jr.↗

InGaAs PV Device Development for TPV Power Systems

lndium Gallium Arsenide (InGaAs) photovoltaic devices have been fabricated with bandgaps ranging from 0.75 eV to 0.60 eV on Indium Phosphide (InP) substrates. Reported efficiencies have been as high as 11.2% (AMO) for the lattice matched 0.75 eV devices. The 0.75 eV cell demonstrated 14.8% efficiency under a 1500 K blackbody with a projected efficiency of 29.3%. The lattice mismatched devices (0.66 and 0.60 eV) demonstrated measured efficiencies of 8% and 6% respectively under similar conditions. Low long wavelength response and high dark currents are responsible for the poor performance of the mismatched devices. Temperature coefficients have been measured and are presented for all of the bandgaps tested.

Wilt, David M.↗

Sample IEEE123 Bus system for OEDI SI

Time series load and PV data from an IEEE123 bus system. An example electrical system, named the OEDI SI feeder, is used to test the workflow in a co-simulation. The system used is the IEEE123 test system, which is a well studied test system (see link below to IEEE PES Test Feeder), but some modifications were made to it to add some solar power modules and measurements on the system. The aim of this project is to create an easy-to-use platform where various types of analytics can be performed on a wide range of electrical grid datasets. The aim is to establish an open-source library of algorithms that universities, national labs and other developers can contribute to which can be used on both open-source and proprietary grid data to improve the analysis of electrical distribution systems for the grid modeling community. OEDI Systems Integration (SI) is a grid algorithms and data analytics API created to standardize how data is sent between different modules that are run as part of a co-simulation. The readme file included in the S3 bucket provides information about the directory structure and how to use the algorithms. The sensors.json file is used to define the measurement locations.

123 bus↗

DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the converters combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.

14 SOLAR ENERGY↗

Accuracy and Validation of Measured and Modeled Data for Distributed PV Interconnection and Control

The distribution grid is changing to become an active resource with complex modeling needs. The new active distribution grid will, within the next ten years, contain a complex mix of load, generation, storage and automated resources all operating with different objectives on different time scales from each other and requiring detailed analysis. Electrical analysis tools that are used to perform capacity and stability studies have been used for transmission system planning for many years. In these tools, the distribution grid was considered a load and its details and physical components were not modeled. The increase in measured data sources can be utilized for better modeling, but also control of distributed energy resources (DER). The utilization of these sources and advanced modeling tools will require data management, and knowledgeable users. Each of these measurement and modeling devices have accuracy constraints, which will ultimately define their future ability to be planned and controlled. This paper discusses the importance of measured data accuracy for inverter control, interconnection and planning tools and proposes ranges of control accuracy needed to satisfy all concerns based on the present grid infrastructure.

Stewart, Emma↗

Final Technical Report: Distributed Controls for High Penetrations of Renewables

The goal of this effort was to apply four potential control analysis/design approaches to the design of distributed grid control systems to address the impact of latency and communications uncertainty with high penetrations of photovoltaic (PV) generation. The four techniques considered were: optimal fixed structure control; Nyquist stability criterion; vector Lyapunov analysis; and Hamiltonian design methods. A reduced order model of the Western Electricity Coordinating Council (WECC) developed for the Matlab Power Systems Toolbox (PST) was employed for the study, as well as representative smaller systems (e.g., a two-area, three-area, and four-area power system). Excellent results were obtained with the optimal fixed structure approach, and the methodology we developed was published in a journal article. This approach is promising because it offers a method for designing optimal control systems with the feedback signals available from Phasor Measurement Unit (PMU) data as opposed to full state feedback or the design of an observer. The Nyquist approach inherently handles time delay and incorporates performance guarantees (e.g., gain and phase margin). We developed a technique that works for moderate sized systems, but the approach does not scale well to extremely large system because of computational complexity. The vector Lyapunov approach was applied to a two area model to demonstrate the utility for modeling communications uncertainty. Application to large power systems requires a method to automatically expand/contract the state space and partition the system so that communications uncertainty can be considered. The Hamiltonian Surface Shaping and Power Flow Control (HSSPFC) design methodology was selected to investigate grid systems for energy storage requirements to support high penetration of variable or stochastic generation (such as wind and PV) and loads. This method was applied to several small system models.

14 SOLAR ENERGY↗

A Coordinated Compensation Strategy for Module-Mismatch of CHB-PV Systems Based on Improved LS-PWM and Reactive Power Injection

Here, the cascaded H-bridge (CHB) converter has become a promising candidate topology for utility-scale photovoltaic systems thanks to merits like modular structure, distributed maximum power point tracking (MPPT), and direct distribution grid access without medium-voltage transformers, etc. However, module-mismatches arising from non-ideal elements like partial shading and parameter variations pose a technical challenge for such systems. If not dealt with properly, module-mismatches can lead to adverse effects like unbalanced dc-link voltages of the modules, distortion of grid current, reduced power generation, etc. Conventional methods, such as reactive power compensation and level-shifted pulse-width modulation (LS-PWM) based compensation, can alleviate this issue, but their performances are still limited by the allowable modulation range of power converters. In this paper, a compensation strategy combining reactive power compensation with a novel modulation method is proposed to extend the operating range in terms of module mismatch. Experimental results on a 2.4kW/208V single-phase setup are presented and have demonstrated that the proposed method can not only ride through a larger range of module-mismatches but also improve solar power utilization and system efficiency owing to reduced switching events, non-compromised MPPT, and less required reactive power.

42 ENGINEERING↗

Degradation of Photovoltaic Modules Under High Voltage Stress in the Field: Preprint

The degradation in performance for eight photovoltaic (PV) modules stressed at high voltage (HV) is presented. Four types of modules--tandem-junction and triple-junction amorphous thin-film silicon, plus crystalline and polycrystalline silicon modules--were tested, with a pair of each biased at opposite polarities. They were deployed outdoors between 2001 and 2009 with their respective HV leakage currents through the module encapsulation continuously monitored with a data acquisition system, along with air temperature and relative humidity. For the first 5 years, all modules were biased continuously at fixed 600 VDC, day and night. In the last 2 years, the modules were step-bias stressed cyclically up and down in voltage between 10 and 600 VDC, in steps of tens to hundreds of volts. This allowed characterization of leakage current versus voltage under a large range of temperature and moisture conditions, facilitating determination of leakage paths. An analysis of the degradation is presented, along with integrated leakage charge. In HV operation: the bulk silicon modules degraded either insignificantly or at rates of 0.1%/yr higher than modules not biased at HV; for the thin-film silicon modules, the added loss rates are insignificant for one type, or 0.2%/yr-0.6%/yr larger for the other type.

14 SOLAR ENERGY↗

Uncertainty-aware photovoltaic generation estimation through fusion of physics with harmonics information using Bayesian neural networks

We develop an aggregate photovoltaic generation estimation methodology that uses diverse inputs and can reason on its current input-dependent predictive uncertainty. Named PVPHEst, for PhotoVoltaic Physics- & Harmonics-driven Estimator, the resulting tool is intelligently weighing and fusing information carried by the output of physics models, harmonics, and line sensors, using Bayesian neural networks and related techniques aimed at solving machine learning problems with intrinsic uncertainty quantification. As each of the three input classes carries heterogeneous information that only sheds light on one facet of the estimation problem but its value can diminish in the face of diverse grid phenomena, PV-PHEst with its estimation and uncertainty reasoning capabilities perform a nontrivial and potentially mission-critical task of value to grid operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic Analysis of Novel PV Plant Designs for Extreme Cost Reductions

A techno-economic analysis is underway examining the cost and performance of future large-scale photovoltaic (PV) plant components, including bifacial modules, tandem modules, increased plant voltage architectures, and module-level power electronics. Integration of these components into PV plant designs is compared with current PV technologies based on levelized cost of electricity (LCOE). Baseline models are developed and validated against recorded PV plant performance data. Expected cost and performance data of future PV technologies are incorporated into the baseline models. An evolutionary algorithm is utilized to optimize PV plant configuration, technology combination, and LCOE. This paper focuses on the bifacial module analysis.

14 SOLAR ENERGY↗

InGaAs PV device development for TPV power systems

Indium gallium arsenide (InGaAs) photovoltaic devices have been fabricated with bandgaps ranging from 0.75 eV to 0.60 on Indium phosphide (InP) substrates. Reported efficiencies have been as high as 11.2 percent (AMO) for the lattice matched 0.75 eV devices. The 0.75 eV cell demonstrated 14.8 percent efficiency under a 1500 K blackbody with a projected efficiency of 29.3 percent. The lattice mismatched devices (0.66 and 0.60 eV) demonstrated measured efficiencies of 8 percent and 6 percent respectively under similar conditions. Low long wavelength response and high rack currents are responsible for the poor performance of the mismatched devices. Temperature coefficients have been measured and are presented for all of the bandgaps tested.

Wilt, David M.↗

Test Protocols for Advanced Inverter Interoperability Functions - Appendices

Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.

14 SOLAR ENERGY↗

Test Protocols for Advanced Inverter Interoperability Functions – Main Document

Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.

14 SOLAR ENERGY↗

Photovoltaic's silica-rich waste sludge as supplementary cementitious material (SCM)

Waste sludge, a solid recovered from wastewater of photovoltaic-industries, composes of agglomerates of nano-particles like SiO{sub 2} and CaCO{sub 3}. This sludge deflocculates in aqueous solutions into nano-particles smaller than 1 μm. Thus, this sludge constitutes a potentially hazardous waste when it is improperly disposed. Due to its high content of amorphous SiO{sub 2}, this sludge has a potential use as supplementary cementitious material (SCM) in concrete. In this study the main properties of three different samples of photovoltaic's silica-rich waste sludge (nSS) were physically and chemically characterized. The characterization techniques included: scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), nitrogen physical adsorption isotherm (BET method), density by Helium pycnometry, particle size distribution determined by laser light scattering (LLS) and zeta-potential measurements by dynamic light scattering (DLS). In addition, a dispersability study was performed to design stable slurries to be used as liquid additives for the concrete production on site. The effects on the hydration kinetics of cement pastes by the incorporation of nSS in the designed slurries were determined using an isothermal calorimeter. A compressive strength test of standard mortars with 7% of cement replacement was performed to determine the pozzolanic activity of the waste nano-silica sludge. Finally, the hardened system was fully characterized to determine the phase composition. The results demonstrate that the nSS can be utilized as SCM to replace portion of cement in mortars, thereby decreasing the CO{sub 2} footprint and the environmental impact of concrete. -- Highlights: •Three different samples of PV nano-silica sludge (nSS) were fully characterized. •nSS is composed of agglomerates of nano-particles like SiO{sub 2} and CaCO{sub 3}. •Dispersability studies demonstrated that nSS agglomerates are broken to nano-size. •nSS can be classified as a pozzolanic material with activity index higher than 100. •nSS can be use as a potential SCM to partly replace cement in concrete.

36 MATERIALS SCIENCE↗

Resource recovery from urban stock, the example of cadmium and tellurium from thin film module recycling

Highlights: ► The semiconductor layer on thin-film photovoltaic modules can be removed from the glass-plate by vacuum blast cleaning. ► The separation of blasting agent and semiconductor can be performed using flotation with a valuable yield of 55%. ► PV modules are a promising source for the recovery of tellurium in the future. - Abstract: Raw material supply is essential for all industrial activities. The use of secondary raw material gains more importance since ore grade in primary production is decreasing. Meanwhile urban stock contains considerable amounts of various elements. Photovoltaic (PV) generating systems are part of the urban stock and recycling technologies for PV thin film modules with CdTe as semiconductor are needed because cadmium could cause hazardous environmental impact and tellurium is a scarce element where future supply might be constrained. The paper describes a sequence of mechanical processing techniques for end-of-life PV thin film modules consisting of sandblasting and flotation. Separation of the semiconductor material from the glass surface was possible, however, enrichment and yield of valuables in the flotation step were non-satisfying. Nevertheless, recovery of valuable metals from urban stock is a viable method for the extension of the availability of limited natural resources.

36 MATERIALS SCIENCE↗

Performance of solar leasing for low- and middle-income customers in Connecticut

Policymakers are increasingly interested in expanding access to rooftop photovoltaic systems. This study analyzes the financial performance of a Connecticut Green Bank (CGB) solar leasing program, run in partnership with PosiGen, that targets low- and moderate-income customers. We show that this program has successfully reached underserved customers and has reasonable repayment rates given the credit characteristics of the participants. The CGB/PosiGen program reaches many more underserved customers than other PV financing programs in Connecticut.For example, the majority of CGB/PosiGen participants (58%) live in census tracts that have a median income of less than 80% of the area median income (AMI). In contrast, only 9% of participants in the other CGB solar financing programs live in these census tracts. Furthermore, the majority of CGB/PosiGen participants (56%) have FICO scores that would generally be considered non-prime (<670), whereas only 2% of participants in the other programs have similarly low scores. Credit, not income, is the primary factor that explains participants’ financial performance. Overall, we find that delinquency and annualized losses are higher for PosiGen (2.3% and 0.9%) than for other CGB programs (1.4% and 0.1%). Across the CGB programs, lower credit scores are associated with higher rates of delinquency and loss. Therefore, participants’ lower credit scores explain much of the program’s higher rates of delinquency and annualized losses. PosiGen leases perform competitively with market-rate solar and non-solar leases and loans. When compared to securities backed by market-rate PV loans and leases with similar amounts of seasoning, we find that the PosiGen leases have higher delinquency rates but comparable gross loss rates. The similarity in losses is notable given that loss rates for PosiGen leases were higher than those of the other CGB leases and loans. Rather than the PosiGen leases having high loss rates, other CGB leases and loans have unusually low loss rates. We also compare PosiGen to non-solar benchmarks, including indices of auto and consumer loans. We find that the PosiGen leases have significantly less delinquency than non-prime auto loans and have performance comparable to many consumer loans. The U.S. Department of Energy’s Solar Energy Technologies Office supported this research.

14 SOLAR ENERGY↗

Development Support for NREL's System Advisor Model (SAM): Cooperative Research and Development, CRADA Number CRD-20-16998 (Final Report)

The variable nature of renewable generation, which depends on the sun shining and wind blowing for example, presents challenges for adequate and least-cost resource planning. The deployment of renewable generation assets is anticipated to increase due to various drivers, such as declining costs, favorable government policies, and increasing procurement by corporations and consumers. High levels of renewable penetration are anticipated to pose flexibility, reliability, and cost challenges to the electrical system. The development and implementation of new features into performance modeling software, such as the National Renewable Energy Laboratory's (NREL) System Advisor Model (SAM), is one way to help think through these challenges and develop appropriate strategies.

14 SOLAR ENERGY↗

Simulate Wind Loading on RUTE SunTracker: Cooperative Research and Development (Final Report)

RUTE produces and delivers efficient, sustainable structural foundation systems for the wind and solar industries, instrumental in the effort to lower the cost of clean electricity and reduce CO2. RUTE's SunTracker is a high-clearance agrivoltaic solar array. The system uses raised cables, providing support with less materials and cost. These cables can provide tracking for increased energy generation and greater revenue, allowing the land beneath to be used for other means simultaneously. RUTE provided data files that NREL will use to perform computational fluid dynamics (CFD) simulations to characterize and predict wind loading on the 6x6 RUTE SunTracker photovoltaic (PV) array. Varying both the panel orientations and wind speeds provides information on how the array can manage a variety of weather conditions. These results, in turn, inform RUTE's design and construction of these arrays.

14 SOLAR ENERGY↗