Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Joining Composite Parts With Off-Stoichiometric Matrix Reflow

Adhesive bonding is an attractive alternative to fasteners for composite part assembly. In addition to superior performance, it reduces weight and eliminates costly manufacturing processes. However, current adhesive bonding methods are highly susceptible to contamination flaws, and it is difficult to verify bonds because nondestructive testing to quantify bond strength is still under development. In aerospace applications, this often results in fasteners being added to provide redundant load paths. Co-cured parts can provide an alternative because they can be inspected using traditional nondestructive evaluation techniques such as ultrasound. However, co-curing can only be accomplished for a limited range of geometries. NASA’s Adhesive Free Bonding of Composites (AERoBOND) is an alternative method for bonding composite parts. The goal of this study was to further develop and understand the capabilities of this novel bonding technique.

Charles T. Dolph↗

Dry Preform Stitching Using Temporary Vacuum Consolidation

Stitched composites (composite parts stitched in a dry preform state that are infused with resin and cured to a final shape) offer a variety of benefits for modern aircraft structures. In this document one means of stitching dry fabric preforms in a state of temporary vacuum consolidation is discussed. This vacuum consolidation allows for the completion of stitching procedures while the dry preform thickness is temporarily reduced to a thickness reflective of its final cured thickness. Here, a temporary vacuum consolidation process enabling stitching of preforms of unconsolidated nominal thickness greater than the maximum allowable stitching thickness for the Integrated Structural Assembly of Advanced Composite (ISAAC) system is explored as a use case for such processes. Temporary vacuum consolidation processes may lead to simplified manufacturing processes or desirable composite material properties in the future.

Stitched Composites↗

Laser Sintering of RTM385-SLS Thermoset Polyimides With Boron Nitride

RTM385-SLS is a melt-processable thermoset polyimide resin specially formulated with a complex melt viscosity (ƞ*) of ~104-105 poise for laser sintering. RTM385-SLS resin powder was mixed with 20-25% of hexagonal boron nitride (h-BN) and subjected to laser sintering (LS) to print out “Green” disks and dogbone specimens which could be further post-cured in an oven to complete the crosslinking of the reactive phenylethynyllphthalic anhydride (PEPA) terminal groups within the resin to achieve a very high glass transition temperature (T g ) of 385°C. The cured composite specimens were then subjected to thermal analysis, thermal conductivity measurement and mechanical testing for characterization.

Additive manufacturing↗

RF Characterization of a Photocurable PEDOT:PSS:PEGDA Conductive Biomaterial for 3D-Printing Implantable Antennas

In this work, we demonstrate photocurable PEDOT:PSS:PEGDA biomaterial as a promising candidate for intracorporeal 3D printing. Intracorporeal 3D printing offers a less invasive method which offer flexibility to tailor the form factor of printed structures. Previous work has demonstrated the feasibility of a robotic probe to 3D-print biological tissues intracorporeally via a minor incision. This same probe could also 3D-print implantable antennas as long as a suitable conductive material is identified in terms of conductivity, biocompatibility, and ability to cure at room/body temperature for safety purposes. We assess the frequency-dependent conductivity of this biomaterial and explore the Radio-Frequency (RF) performance of resulting antennas operating in free-space and inside tissue-emulating phantoms. Results show that PEDOT:PSS biomaterial with 21% and 30% PEGDA content exhibit a conductivity of ~10 4 S/m up to 5 GHz, suitable for wireless implants. Comparing the two, 21% PEGDA content exhibits poorer curing abilities, while 30% PEGDA exhibits slightly lower conductivity. Measurements for 2.4 GHz free-space dipoles conducted in an anechoic chamber reveal only ~0.8 dB and ~1 dB lower gain for PEDOT:PSS:21%PEGDA and PEDOT:PSS:30%PEGDA biomaterial, respectively, as compared to their copper counterpart. For a 5 mm-deep implanted patch antenna, these two biomaterials exhibit 3.05 dB and 3.84 dB higher transmission loss than copper, respectively. If deemed necessary, this performance degradation can be overcome by increasing the overall antenna size since the printing process is now minimally invasive and miniaturization requirements can be relaxed.

3D-printing↗

Carbon Nanotube – Polysiloxane Nanocomposites for Ablative Thermal Protection Systems

Ultra-high temperature resins (UHTR) such as polysiloxane possess excellent characteristics for ablation including low thermal conductivity, lightweight composition, high thermal resistance, and the ability to form a durable char layer. To enhance its mechanical strength, the aerospace industry utilizes fiber reinforcement, such as carbon fiber reinforced polysiloxane (CF-polysiloxane), due to its high strength-to-weight ratio. Carbon nanotubes (CNTs) have advantages over microfibers including higher specific strength, lower density, and customizable thermal conductivity. Their nano-scale dimensions allow for a more homogenous material compared to traditional microfibers. Conventional methods of incorporating CNTs into resins often have structural defects such as voids, CNT agglomerations, and randomly dispersed CNTs, resulting in marginal improvements in properties. A novel approach known as bulk nanocomposite laminating (BNL) has been introduced involving CNT densification, resin polymer infiltration, and pressurized curing to achieve a high packing density exceeding 35% by volume. Characterization and testing to simulate re-entry conditions is performed with a sample of CNT-polysiloxane nanocomposite cured onto a CF-polysiloxane backing. These samples are subjected to ablation by an oxyacetylene flame while collecting temperature data to evaluate thermal protection properties.

Palak B Patel↗

Solid composites containing polymeric matrix with carbon fibers embedded therein

A functionalized carbon fiber having covalently bound on its surface a partially cured epoxy or amine-containing sizing agent, wherein at least a portion of epoxide or amine groups in the sizing agent are available as uncrosslinked epoxide or amine groups, which corresponds to a curing degree of epoxide or amine groups of no more than about 0.6. Composites comprised of these functionalized carbon fibers embedded in a polymeric matrix are also described. Methods for producing the functionalized carbon fibers and composites thereof are also described.

36 MATERIALS SCIENCE↗

Elastic gas barrier coating compositions

An elastic gas barrier coating composition includes a barrier material dispersed in an aqueous media, a polysulfide, and a curing agent reactive with the polysulfide. When applied to a substrate and cured to form a coating, the barrier material forms a continuous phase and a polysulfide elastomer forms a discontinuous phase. An elastic gas coating is also disclosed that includes a continuous phase with a barrier material and a discontinuous phase with a polysulfide elastomer. Substrates at least partially coated with elastic gas barrier coating compositions are further disclosed.

36 MATERIALS SCIENCE↗

Actinic and electron beam radiation curable water based electrode binders and electrodes incorporating same

A process for manufacturing an electrode utilizing electron beam (EB) or actinic radiation to cure the electrode binder is provided. A process is also disclosed for mixing specific actinic or EB radiation curable polymer precursors with electrode solid particles to form an aqueous mixture, application of the mixture to an electrode current collector, followed by the application of actinic or EB radiation to the current collector for curing the polymer, thereby binding the electrode binder to the current collector. Lithium ion batteries, electric double layer capacitors, and components produced therefrom are also provided.

Voelker, Gary E.↗

Performance Advantaged Thermosets from Bioderived Amines: Benefits in Manufacturing, Performance, and End-of-Life

Biomass derived monomers can offer unique functionality, often in the forms of heteroatoms, that is not easily accessible by routine petrochemical routes. Importantly, many of these monomers offer the potential to replace the petrochemical monomers used in the manufacture of thermosets to enable expanded functionality and performance. In the present work, we leverage amine containing monomers that can be obtained via biological conversions in both epoxy and benzoxazine thermosets. These monomers have a wide degree of functionality available to them that augment the material properties. In the case of benzoxazines, monomers that contain both an amine and carboxylic acid are used and the presence of the carboxylic acid leads to an acceleration in cure kinetics and a dramatic reduction in cure temperature. For the epoxy thermosets, multifunctional amine monomers are used as a hardener and the properties of the resultant materials are found to scale with the spacing and identity between reactive centers. The amines can be further modified and reacted to produce a mixed network of triazines and epoxy-amines that enables the end-of-life degradation of these materials. Importantly, subsequent process analysis reveals that the use of bioderived amines can present dramatic reductions in both supply chain energy and GHG emissions while possessing a cost similar to their petrochemical counterparts. Overall, this work demonstrates the robust potential to use bioderived amines for performance advantaged properties.

bioderived monomers↗

Wireless sensing and control of temperature using magnetic fields

A method and system for sensing and controlling temperature with magnetic fields are provided. The method comprises placing a compound in thermal communication with a number of temperature or heat sources and placing a number of magnets in thermal communication with the compound. A number of magnetic sensors are placed in electromagnetic communication with the number of magnets. Changes in the magnetic field of the magnets are detected by the sensors and used to determine the temperature of the compound according to a model that maps magnetic field characteristics to temperature. The amount of cure of the compound can then be estimated from the temperature. The temperature or heat sources are controlled in response to the temperature measurement and the estimated amount of cure of the compound.

Chen Mazumdar, Yi↗

Cross-linkable nanocomposite anticorrosion coating

Nanocomposite anticorrosion coating can be achieved by depositing alternating, multilayers of a cross-linkable polymer and dispersed and aligned inorganic platelets followed by cross-linking of the cross-linkable polymer. The cross-linkable polymer can be an externally cross-linkable polymer that is cross-linked by diffusing a cross-linking agent into the deposited multilayer coating. Alternately, the cross-linkable polymer can be a functionalized cross-linkable polymer that is cross-linked by self-curing, thermal heat curing, or light (e.g., UV) following deposition of the multilayer coating.

Percival, Stephen John↗

Stereolithography additive manufacturing of magnetically aligned liquid crystal elastomers

A method of forming a three-dimensional structure includes forming a layer of resin comprising liquid crystal oligomers and a photoinitiator, applying a magnetic field to the formed layer in a predefined alignment direction for substantially aligning the liquid crystal oligomers in a first orientation; and exposing the formed layer to radiation for curing a first portion of the layer during application of the magnetic field thereby resulting in the first portion having liquid crystal elastomers substantially aligned in the first orientation. The method includes applying a second magnetic field to the formed layer in a predefined second alignment direction for substantially aligning uncured liquid crystal oligomers in a second orientation, and exposing the layer to radiation for curing a second portion of the layer during application of the second magnetic field thereby resulting in the second portion having liquid crystal elastomers substantially aligned in the second orientation.

Arriaga, Rodrigo Telles↗

High resolution and high flexibility fiber optical cables and microfabrication methods for making same

The present disclosure relates to methods of forming a fiber optic core, and a fiber optic component with a highly uniform cladding covering the fiber optic core. In one microfabrication process a first sacrificial tubing is provided which has a predetermined inner diameter. A quantity of a curable polymer is also provided. The first sacrificial tubing is at least partially filled with the curable polymer. The curable polymer is then cured. The first sacrificial tubing is then removed to produce a finished fiber optic core. Additional operations may be performed by which the fiber optic core is placed inside a thermoplastic tubing, which is itself placed inside a sacrificial heat shrink. Heat is applied to reflow the thermoplastic tubing around the fiber optic core, thus forming a highly uniform thickness cladding. When the sacrificial heat shrink tubing is removed a finished fiber optic component is present. Additional microfabrication methods are disclosed which involve dip coating a pre-formed fiber optic core in a polymer, and then curing the polymer to form a finished fiber optic component with a uniform thickness cladding.

Kampasi, Komal↗

Stereolithography additive manufacturing of photoaligned liquid crystal elastomers

A method of forming a three-dimensional structure of liquid crystal (LC) elastomers includes contacting a resin layer of LC oligomers with a layer of photoalignment material, and exposing a portion of photoalignment material to light for aligning the portion of photoalignment material in a first orientation. The LC oligomers adjacent the illuminated portion of photoalignment material align to the first orientation of the illuminated portion. The portion of aligned LC oligomers of the resin layer are cured. Operations for forming additional layers include creating a relative movement of the resin layer away from the photoalignment material, contacting another resin layer with the photoalignment material, and exposing another portion of photoalignment material to light for aligning the photoalignment material in a different orientation. The LC oligomers adjacent the illuminated portion of photoalignment material align to the different orientation, and the portion of aligned LC oligomers of the resin layer are cured.

Moran, Bryan D.↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update to the Performance Assessment for the Savannah River Site Saltstone Disposal Facility - 20124

In 2019, Savannah River Remediation developed a revision to the performance assessment (PA) on behalf of the U.S. Department of Energy (DOE) Savannah River Operations Office (SR) for the near-surface disposal of low-level waste at the Savannah River Site (SRS) Saltstone Disposal Facility (SDF). Soluble waste from SRS Tank Farms undergoes salt processing to remove cesium and other high activity constituents. The low-activity decontaminated salt solution (DSS) is then immobilized by mixing it into a cementitious waste form known as saltstone. After mixing, the saltstone is poured into leak-tight concrete vaults, known as saltstone disposal units (SDUs), where the waste form cures. By the time of facility closure, the SDF is expected to consist of 15 SDUs with a combined capacity of 1.06 E+09 L (280 Mgal) of cured saltstone. The facility operates under a Disposal Authorization Statement (DAS) from DOE and a permit from the South Carolina Department of Health and Environmental Control (SCDHEC). Since the start of operations in 1990, the SDF has received almost 6.7 E+07 L (18 Mgal) of DSS, resulting in the safe disposal of 2.7 E+16 Bq (7.3 E+05 Ci) of activity. Due to the radioactive decay of short-lived contaminants, the total remaining activity in the disposed waste is estimated to be approximately 1.4 E+16 Bq (3.9 E+05 Ci), as of September 2018. The Disposal Authorization Statement requires a demonstration that the system of engineered and natural features of the disposal facility will limit releases from the facility and be protective of human health and the environment for at least the next 1,000 years. The long-term performance of the facility was evaluated under the requirements of the DoE's Radioactive Waste Management Manual (US DOE Manual 435.1-1). Simulations were performed to demonstrate that the disposal facility would meet performance objectives specified in the manual. The evaluation was based on numerical models that simulate the releases of contaminants from the saltstone waste form. Contaminants were transported through groundwater and air pathways to points of assessment to evaluate compliance. In addition, the potential consequences of an inadvertent human intrusion (IHI) were also evaluated. In accordance with the guidance and recommendations in US DoE's technical standard for DAS, deterministic and probabilistic analyses were performed to demonstrate the SDF system, which includes the engineered cover system, the SDUs, the waste form, and the natural features of the site, provides a reasonable expectation that saltstone disposal will meet performance objectives. Post-closure doses to future members of the public (MOP) were evaluated; dose estimates from the air pathway were well below the 1.0 E-04 Sv/yr (10 mrem/yr) performance objective within 1,000 years, and the calculated doses to the MOP from all exposure pathways, including the groundwater and air pathways, were well below the 2.5 E-04 Sv/yr (25 mrem/yr) performance objective within 1,000 years. Doses following an assumed intrusion event within the facility boundaries were well below the IHI performance objectives, where the acute IHI dose was below the acute IHI dose performance objective of 5.0 E-03 Sv (500 mrem) and the chronic IHI dose was below the chronic IHI dose performance objective of 1.0 E-03 Sv/yr (100 mrem/yr) within 1,000 years. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Issue Resolution During the Development of the Performance Assessment for the Savannah River Site Saltstone Disposal Facility - 20125

In 2019, Savannah River Remediation developed a revision to the performance assessment (PA) on behalf of the U.S. Department of Energy (DOE) Savannah River Operations Office (SR) for the near-surface disposal of low-level waste at the Savannah River Site (SRS) Saltstone Disposal Facility (SDF). Soluble waste from SRS Tank Farms undergoes salt processing to remove cesium and other high-activity constituents. The low-activity decontaminated salt solution (DSS) is then immobilized by mixing it into a cementitious waste form known as saltstone. After mixing, the saltstone is poured into leak-tight concrete vaults, known as saltstone disposal units (SDUs), where the waste form cures. By the time of facility closure, the SDF is expected to consist of 15 SDUs with a combined capacity of 1.06 E+09 L (280 Mgal) of cured saltstone. The facility operates under a Disposal Authorization Statement from DOE and a permit from the South Carolina Department of Health and Environmental Control (SCDHEC). Since the start of operations in 1990, the SDF has received almost 6.7 E+07 L (18 Mgal) of DSS, resulting in the safe disposal of 2.7 E+16 Bq (7.3 E+05 Ci) of activity. Due to the radioactive decay of short-lived contaminants, the total remaining activity in the disposed waste is estimated to be approximately 1.4 E+16 Bq (3.9 E+05 Ci), as of September 2018. The Disposal Authorization Statement requires a demonstration that the system of engineered and natural features of the disposal facility will limit releases from the facility and be protective of human health and the environment for at least the next 1,000 years. The long-term performance of the facility was evaluated under the requirements of the DoE's Radioactive Waste Management Manual (US DOE Manual 435.1-1). Simulations were performed to demonstrate that the disposal facility would meet performance objectives specified in the manual. The evaluation was based on numerical models that simulate the releases of contaminants from the saltstone waste form. Contaminants were transported through groundwater and air pathways to points of assessment to evaluate compliance (i.e., 100 m from the SDUs). In addition, the potential consequences of an inadvertent human intrusion (IHI) were also evaluated. A number of issues were overcome during the development of these simulations. These issues were identified as part of internal technical reviews. Simulations are developed by people and people make mistakes, so the internal technical review process is a vital step in PA development. Specific examples of resolved issues include a unit-conversion error, an inappropriate definition for a model boundary condition, a model time-stepping issue, and an error in the calculation for the buildup of contaminants in soil. Actions taken to address these issues resulted in an improved product with a better supported technical basis and more defensible results. The identification and correction of these issues are discussed. By understanding these issues, model developers and technical reviewers working on PAs in the future may avoid repeating these types of mistakes. Transparency with respect to these mistakes builds trust between waste management sites, regulators, and stakeholders. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗