Dilute plasma coupling currents to a high voltage solar array in weak magnetic fields

The plasma coupling current to an approximately 2000 sq cm array was measured for externally biased positive and negative voltages on the array to 1000 V in applied magnetic field strengths from 0 to 0.93 G. The plasma density varied from 2,000 to 1.3 million electrons/cu cm. It was found that the magnetic field primarily increased the plasma coupling current for negative biases. For positive bias, the current could increase or decrease depending on the voltage, field strength, and plasma density. It was also found that the plasma coupling current was not very sensitive to how the plane of the array was oriented relative to the magnetic field.

Grier, N. T.↗

Direct experimental determination of voltage across high-low junctions

High-low (HL) junctions form a part of many semiconductor devices, including back surface field solar cells. A first experimental determination and interpretation of the voltage across the HL junction under low- and high-injection conditions is presented as a function of the voltage across a nearby p/n junction. Theoretical analysis from first principles is shown to bear well on the experimental results. In addition, a test structure is proposed for measurement of the effective surface recombination velocity at the HL junctions.

Daud, T.↗

A new very high voltage semiconductor switch

A new family of semiconductor switches using double injection techniques and compensated deep impurities is described. They have the potential to raise switching voltages a factor of 10 higher (up to 100 kV) than p-n junction devices while exhibiting extremely low (or zero) forward voltage. Several potential power switching applications are indicated.

Sundberg, G. R.↗

High voltage system: Plasma interaction summary

The possible interactions that could exist between a high voltage system and the space plasma environment are reviewed. A solar array is used as an example of such a system. The emphasis in this review is on the discrepancies that exist in this technology in both flight and ground experiment data. It has been found that, in ground testing, there are facility effects, cell size effects and area scaling uncertainties. For space applications there are area scaling and discharge concerns for an array as well as the influence of the large space structures on the collection process. There are still considerable uncertainties in the high voltage-space plasma interaction technology even after several years of effort.

Stevens, N. John↗

Solar wind control of the polar-cap voltage

The results of using various models to predict polar-cap potentials are reviewed. Quantitative predictions of merging rate, and hence of polar-cap voltage, based on subsolar merging models are reviewed, and tests of dayside merging models and their results are reexamined. Predictions and tests of cusp merging models are discussed. Two new empirical formulas for the dependence of the asymptotic polar-cap potential on the IMF are presented, and predictions of the dependence of dayside and lobe merging voltages on the IMF are derived from the antiparallel merging hypothesis.

Reiff, Patricia H.↗

Detecting Faults In High-Voltage Transformers

Simple fixture quickly shows whether high-voltage transformer has excessive voids in dielectric materials and whether high-voltage lead wires too close to transformer case. Fixture is "go/no-go" indicator; corona appears if transformer contains such faults. Nests in wire mesh supported by cap of clear epoxy. If transformer has defects, blue glow of corona appears in mesh and is seen through cap.

Blow, Raymond K.↗

Evaluation of high-voltage, high-power, solid-state remote power controllers for amps

The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.

Callis, Charles P.↗

Analysis of pre-flight modulator voltage calibration data for the Voyager plasma science experiment

The Voyager Plasma Science (PLS) modulator calibration (MVM) data analysis was undertaken in order to check the correctness of the fast A/D converter formulas that connect low voltage monitor signals (MV) with digital outputs (DN), to determine the proportionality constants between the actual modulator grid potential (V) and the monitor voltage (MV), and to establish an algorithm to link the digitized readouts (DN) with the actual grid potential (V). The analysis results are surprising in that the derived conversion constants deviate by fairly significant amounts from their nominal values. However, it must be kept in mind that the test results which were used for analysis may be very imprecise. Even if it is assumed that the test result errors are very large, they do no appear to be capable to account for all discrepancies between the theoretical expectations and the results of the analysis. Measurements with the flight spare instrument appear to be the only means of investigating these effects further.

Nastov, Ognen↗

Test results of high-voltage, high-power, solid-state remote power controllers

This report discusses the results of testing high-voltage, high-power, solid-state remote power controllers (RPC) using RPCs designed and built by John C. Sturman at the Lewis Research Center, Cleveland, Ohio, and utilizing the Autonomously Managed Power Systems (AMPS) breadboard/test facility. These test results are used to determine usefulness of the RPCs for future applications in high-voltage direct-current space power.

Johnson, Yvette Binford↗

Tunneling effects in the current-voltage characteristics of high-efficiency GaAs solar cells

Evidence is that tunneling via states in the forbidden gap is the dominant source of excess current in the dark current-voltage (I-V) characteristics of high-efficiency DMCVD grown Al(x)Ga(1-x)As/GaAs(x is equal to or greater than 0.85) solar cells. The dark forward and reverse I-V measurements were made on several solar cells, for the first time, at temperatures between 193 and 301 K. Low-voltage reverse-bias I-V data of a number of cells give a thermal activation energy for excess current of 0.026 + or - 0.005 eV, which corresponds to the carbon impurity in GaAs. However, other energy levels between 0.02 eV and 0.04 eV were observed in some cells which may correspond to impurity levels introduced by Cu, Si, Ge, or Cd. The forward-bias excess current is mainly due to carrier tunneling between localized levels created in the space-charge layer by impurities such as carbon, which are incorporated during the solar cell growth process. A model is suggested to explain the results.

Kachare, R.↗

Design guide: Designing and building high voltage power supplies, volume 1

This report contains an accumulation of publications and analyses aimed at developing guidelines for improving both high voltage and low voltage power supplies for the U.S. Air Force systems command. It is the intent of the report to supply good design and manufacturing techniques for the packaging and the building of high quality, reliable, long-life power supplies. These data are based on the wealth of engineering practices established by design and manufacturing engineers.

William G Dunbar↗

Deep-level transient spectroscopy of Al(x)Ga(1-x)As/GaAs using nondestructive acousto-electric voltage measurement

The amplitude and the transient time constant of the acoustoelectric voltage were measured as a function of temperature to determine the activation energy of deep levels in Al(x)Ga(1-x)As/GaAs grown by molecular-beam epitaxy. In comparison to other methods based on monitoring the capacitance transient, deep-level transient spectroscopy has several advantages. The technique is nondestructive and highly sensitive, and, because of the dependence of the polarity of the acoustoelectric voltage on the carrier type, it yields information about the charge of the transient carriers and the type of deep traps involved in the release or trapping of these carriers.

Tabib-Azar, Massood↗

High altitude current-voltage measurement of GaAs/Ge solar cells

Measurements of high-voltage (Voc of 1.2 V) gallium arsenide on germanium tandem junction solar cells at air mass 0.22 showed that the insolation in the red portion of the solar spectrum is insufficient to obtain high fill factor. On the basis of measurements in the LeRC X-25L solar simulator, these cells were believed to be as efficient as 21.68 percent AM0. Solar simulator spectrum errors in the red end allowed the fill factor to be as high as 78.7 percent. When a similar cell's current-voltage characteristic was measured at high altitude in the NASA Lear Jet Facility, a loss of 15 percentage points in fill factor was observed. This decrease was caused by insufficient current in the germanium bottom cell of the tandem stack.

Hart, Russell E., Jr.↗

High frequency capacitance-voltage characteristics of thermally grown SiO2 films on beta-SiC

Silicon dioxide films grown under dry and wet oxidation environment on beta-SiC films have been studied. The beta-SiC films had been heteroepitaxially grown on both on-axis and 2-deg off-axis (001) Si substrates. Capacitance-voltage and conductance-voltage characteristics of metal-oxide-semiconductor structures were measured in a frequency range of 10 kHz to 1 MHz. From these measurements, the interface trap density and the effective fixed oxide charge density were observed to be generally lower for off-axis samples.

Tang, S. M.↗

High-voltage plasma interactions calculations using NASCAP/LEO

This paper reviews four previous simulations (two laboratory and two space-flight) of interactions of a high-voltage spacecraft with a plasma under low-earth orbit conditions, performed using a three-dimensional computer code NASCAP/LEO. Results show that NASCAP/LEO can perform meaningful simulations of high-voltage plasma interactions taking into account three-dimensional effects of geometry, spacecraft motion, and magnetic field. Two new calculations are presented: (1) for current collection by 1-mm pinholes in wires (showing that a pinhole in a wire can collect far more current than a similar pinhole in a flat plate); and (2) current collection by Charge-2 mother vehicle launched in December 1985. It is shown that the Charge-2 calculations predicted successfully ion collection at negative bias, the floating potential of a probe outside or inside the sheath under negative bias conditions, and magnetically limited electron collection under electron beam operation at high altitude.

Mandell, M. J.↗

Improved high-voltage, high-frequency square-wave generator

This paper describes the design and operation of a prototype high-voltage full-floating high-frequency square-wave generator which is an improved version of the generator developed by Bernius and Chutjian (1989). The present design overcomes possible momentary simultaneous ON states in the MOSFET configuration and is less susceptible to deleterious effects caused by the component aging and replacements with nonidentical parts. The circuit performs well over a wide voltage and frequency range, until a limit is imposed by the operating characteristics of the active MOSFET elements. Circuit diagrams are presented.

Bernius, Mark T.↗

Switched-Capacitor Voltage Multiplier

Dc-to-dc power converter multiplies input supply potential by factor of nearly 40. Design does not make use of transformers or inductors but effects voltage boost-up by capacitive energy transfer. Circuit primarily made up of banks of capacitors, connected by network of integrated-circuit relays. Converter functionally linear voltage amplifier with fixed gain figure. Bipolar in operation. Output fully floating, and excellent dc isolation between input and output terminals.

Sridharan, Govind↗

SPEAR-1: An experiment to measure current collection in the ionosphere by high voltage biased conductors

An experiment is described in which a high electrical potential difference, up to 45 kV, was applied between deployed conducting spheres and a sounding rocket in the ionosphere. Measurements were made of the applied voltage and the resulting currents for each of 24 applications of different high potentials. In addition, diagnostic measurements of optical emissions in the vicinity of the spheres, energetic particle flow to the sounding rocket, dc electric field and wave data were made. The ambient plasma and neutral environments were measured by a Langmuir probe and a cold cathode neutral ionization gauge, respectively. The payload is described and examples of the measured current and voltage characteristics are presented. The characteristics of the measured currents are discussed in terms of the diagnostic measurements and the in-situ measurements of the vehicle environment. In general, it was found that the currents observed were at a level typical of magnetically limited currents from the ionospheric plasma for potentials less than 12 kV, and slightly higher for larger potentials. However, due to the failure to expose the plasma contactor, the vehicle sheath modified the sphere sheaths and made comparisons with the analytic models of Langmuir-Blodgett and Parker-Murphy less meaningful. Examples of localized enhancements of ambient gas density resulting from the operation of the attitude control system thrusters (cold nitrogen) were obtained. Current measurements and optical data indicated localized discharges due to enhanced gas density that reduced the vehicle-ionosphere impedance.

Raitt, W. John↗