Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “planning optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

The Zwicky Transient Facility: Surveys and Scheduler

Presented here is a novel algorithm for scheduling the observations of time-domain imaging surveys. Our integer linear programming approach optimizes an observing plan for an entire night by assigning targets to temporal blocks, enabling strict control of the number of exposures obtained per field and minimizing filter changes. A subsequent optimization step minimizes slew times between each observation. Our optimization metric self-consistently weights contributions from time-varying airmass, seeing, and sky brightness to maximize the transient discovery rate. We describe the implementation of this algorithm on the surveys of the Zwicky Transient Facility and present its on-sky performance.

79 ASTRONOMY AND ASTROPHYSICS↗

Helicopter terminal approach using differential GPS with vertical-axis enhancement

The NAVSTAR Global Positioning System (GPS) in differential mode (DGPS) has been shown to be least accurate in the vertical axis. The vertical axis also has the most stringent accuracy requirements for aircraft precision approach and landing. A series of flight tests were conducted to evaluate a concept for improving the DGPS vertical axis navigation performance. These tests incorporated augmentation sensors to aid the DGPS navigation solution during terminal approach operations. A GPS receiver was installed on board a NASA helicopter and interfaced with a real-time digital computer system. A reconfigurable navigation filter programmed in the digital computer provided an augmented DGPS solution, with selectable inputs from a low-cost vertical accelerometer, a barometric altimeter, and the aircraft attitude gyros. The reference aircraft position was determined by a laser tracker. Extensive post-test analysis was done to optimize the filter performance during the terminal approach operation. Test results show that baro-altimeter aiding can significantly improve vertical axis performance. Follow-on tests are planned for the optimized configurations.

Edwards, F. G.↗

TH-CD-202-12: Online Inter-Beam Replanning Based On Real-Time Dose Reconstruction

Purpose: This work provides a proof-of-concept study for online replanning during treatment delivery for step-and-shoot prostate SBRT, based on real-time dose reconstruction. Online replanning is expected to improve the trade-off between target coverage and organ-at-risk dose in the presence of intra-fractional motion. Methods: We have implemented an online replanning workflow on top of our previously reported real-time dose reconstruction software which connects to an Elekta research linac. The treatment planning system DynaPlan was extended to (1) re-optimize and sequence treatment plans (in clockwise beam order) before each beam, based on actual delivered dose, in a timeframe limited by the gantry rotation between subsequent beams, and (2) send the respective segments to the delivery control software DynaTrack which starts/continues treatment immediately.To investigate the impact of a reduced safety margin, we have created and delivered (on a linac emulator) a conventional CTV+5/3mm (I) and a reduced CTV+1mm margin (II) treatment plan for a prostate patient. We have assessed CTV coverage with and without inter-beam replanning, all exposed to a gradual target shift of 0–5mm in posterior and inferior direction from start until the end of delivery. Results: For the reconstructed conventional plan (I), D98 for CTV was 100% of D98 of the planned dose. For the reconstructed margin-reduced plan (II), D98 for CTV was 95% of the planned D98 without replanning, but could be recovered to 99% by replanning for each beam. Plan (II) with replanning resulted in a decrease for bladder V90% by 88% and an increase to rectum V90% by 9% compared to the conventional plan (I). Dose calculation/accumulation was performed in <15ms per MLC aperture, replanning in <15s per beam. Conclusion: We have shown that online inter-beam replanning is technically feasible and potentially allows for a margin reduction. Future investigation considering motion-robust replanning optimization parameters is in progress. We acknowledge support of the MLC research from Elekta AB. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

60 APPLIED LIFE SCIENCES↗

Practical aspects and uncertainty analysis of biological effective dose (BED) regarding its three-dimensional calculation in multiphase radiotherapy treatment plans

Purpose: There is a growing interest in the radiation oncology community to use the biological effective dose (BED) rather than the physical dose (PD) in treatment plan evaluation and optimization due to its stronger correlation with radiobiological effects. Radiotherapy patients may receive treatments involving a single only phase or multiple phases (e.g., primary and boost). Since most treatment planning systems cannot calculate the analytical BED distribution in multiphase treatments, an approximate multiphase BED expression, which is based on the total physical dose distribution, has been used. The purpose of this paper is to reveal the mathematical properties of the approximate BED formulation, relative to the true BED. Methods: The mathematical properties of the approximate multiphase BED equation are analyzed and evaluated. In order to better understand the accuracy of the approximate multiphase BED equation, the true multiphase BED equation was derived and the mathematical differences between the true and approximate multiphase BED equations were determined. The magnitude of its inaccuracies under common clinical circumstances was also studied. All calculations were performed on a voxel-by-voxel basis using the three-dimensional dose matrices. Results: Results showed that the approximate multiphase BED equation is accurate only when the dose-per-fractions (DPFs) in both the first and second phases are equal, which occur when the dose distribution does not significantly change between the phases. In the case of heterogeneous dose distributions, which significantly vary between the phases, there are fewer occurrences of equal DPFs and hence the inaccuracy of the approximate multiphase BED is greater. These characteristics are usually seen in the dose distributions being delivered to organs at risk rather than to targets. Conclusions: The finding of this study indicates that the true multiphase BED equation should be implemented in the treatment planning systems due to the inconsistent accuracy of the approximate multiphase BED equation in most of the clinical situations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-462: Fixed-Jaw Optimization for Critical Structure Sparing in IMRT Treatment Planning: Beam Modeling Cautions for Non-Routine Use

Purpose: Multiple publications exist concerning fixed-jaw utilization to avoid linac carriage shifts and reduce intensity modulated radiotherapy (IMRT) treatment times. The purpose of this work is to demonstrate delivery QA discrepancies and illustrate the need for improved treatment planning system (TPS) commissioning for non-routine use. Methods: A 6cm diameter spherical target was delineated on a virtual phantom containing the Iba Matrixx linear array within the Varian Eclipse TPS. Optimization was performed for target coverage for the following 3 scenarios: a single open, zero degree field where the X and Y jaws completely cover the target; the same field using an asymmetric, fixed-jaw technique where the upper Y jaw does not cover the superior 2cm of the target; and both of the aforementioned directed at the target at 315 and 45 degree gantry angles, respectively. This final orientation was also irradiated on a linac for delivery analysis. A sarcoma patient case was also analyzed where the fixed jaw technique was utilized for kidney sparing. Results: The open beam results were as predicted but the fixed-jaw results demonstrate a pronounced fluence increase along the asymmetric, upper jaw. Analysis of the delivery of the combined beam plan Resultin 83% of pixels evaluated passing gamma criteria of 3%, 3mm DTA. Analysis for the sarcoma patient, in the plane of the shielded kidney, indicated 93% passing although the maximum dose discrepancies in this region were approximately 23%. Conclusion: Optimization within the target is routinely performed using MLC leaf-end characteristics. The fixed-jaw technique forces optimization of target coverage to utilize the penumbra profiles of the associated beamdefining jaw. If the profiles were collected using a common 0.125cc ionization chamber, the resolution may be insufficient resulting in a planvs.-delivery mismatch. It is recommended that high-resolution beam characteristics be considered when non-routine planning methods are utilized.

60 APPLIED LIFE SCIENCES↗

SU-F-T-422: Detection of Optimal Tangential Partial Arc Span for VMAT Planning in IntactLeft-Breast Treatment

Purpose: This study was designed to investigate an appropriate arc span for intact partial Left breast irradiation by VMAT planning. Methods: Four cases of carcinoma left intact breast was chosen randomly for this study. Both medial tangential and left-lateral tangential arc (G20°, G25°, G30°, G35°, G40°) were used having the same length and bilaterally symmetric. For each patient base plan was generated for 30° arc and rest of other arc plans were generated by keeping all plan parameters same, only arc span were changed. All patient plans were generated on treatment planning system Monaco (V 5.00.02) for 50 Gy dose in 25 fractions. PTV contours were clipped 3 mm from skin (patient). All plans were normalized in such a way that 95 % of prescription dose would cover 96 % of PTV volume. Results: Mean MU for 20°, 25°, 30°, 35° and 40° were 509 ± 18.8, 529.1 ± 20.2, 544.4 ± 20.8, 579.1 ±51.8, 607.2 ± 40.2 similarly mean hot spot (volume covered by 105% of prescription dose) were 2.9 ± 1.2, 3.7 ± 3.0, 1.5 ± 1.7, 1.3±0.6, 0.4 ± 0.4, mean contralateral breast dose (cGy) were 180.4 ± 242.3, 71.5 ± 52.7, 76.2 ± 58.8, 85.9 ± 70.5, 90.7 ± 70.1, mean heart dose (cGy) were 285.8 ± 87.2, 221.2 ± 62.8, 274.5 ± 95.5, 234.8 ± 73.8, 263.2 ± 81.6, V20 for ipsilateral lung were 15.4 ± 5.3, 14.3 ± 3.6, 15.3 ± 2.9, 14.2 ± 3.9, 14.7 ± 3.2 and V5 for ipsilateral lung were 33.9 ± 8.2, 31.0 ± 3.5, 42.6 ±15.6, 36.4 ± 12.9, 37.0 ± 7.5. Conclusion: The study concluded that appropriate arc span used for tangential intact breast treatment was optimally 30° because larger arc span were giving lower isodose spill in ipsilateral lung and smaller arc were giving heterogeneous dose distribution in PTV.

60 APPLIED LIFE SCIENCES↗

SU-E-T-215: Comparison of VMAT-SABR Treatment Plans with Flattened Filter (FF) Beam and Flattening Filter-Free (FFF) Beam for Localized Prostate Cancer

Purpose: The purpose of this study is to access VMAT-SABR plan using flattening filter (FF) and flattening filter-free (FFF) beam, and compare the verification results for all pretreatment plans. Methods: SABR plans for 20 prostate patients were optimized in the Eclipse treatment planning system. A prescription dose was 42.7 Gy/7 fractions. Four SABR plans for each patient were calculated using Acuros XB algorithm with both FF and FFF beams of 6- and 10-MV. The dose-volume histograms (DVH) and technical parameters were recorded and compared. A pretreatment verification was performed and the gamma analysis was used to quantify the agreement between calculations and measurements. Results: For each patient, the DVHs are closely similar for plans of four different beams. There are small differences showed in dose distributions and corresponding DVHs when comparing the each plan related to the same patient. Sparing on bladder and rectum was slightly better on plans with 10-MV FF and FFF than with 6-MV FF and FFF, but this difference was negligible. However, there was no significance in the other OARs. The mean agreement of 3%/3mm criteria was higher than 97% in all plans. The mean MUs and deliver time employed was 1701±101 and 3.02±0.17 min for 6-MV FF, 1870±116 and 1.69±0.08 min for 6-MV FFF, 1471±86 and 2.68±0.14 min for 10-MV FF, and 1619±101 and 0.98±0.04 min for 10-MV FFF, respectively. Conclusion: Dose distributions on prostate SABR plans using FFF beams were similar to those generated by FF beams. However, the use of FFF beam offers a clear benefit in delivery time when compared to FF beam. Verification of pretreatment also represented the acceptable and comparable results in all plans using FF beam as well as FFF beam. Therefore, this study suggests that the use of FFF beam is feasible and efficient technique for prostate SABR.

60 APPLIED LIFE SCIENCES↗

Technological cost-reduction pathways for attenuator wave energy converters in the marine hydrokinetic environment.

This report considers and prioritizes the primary potential technical cost reduction pathways for offshore wave activated body attenuators designed for ocean resources. This report focuses on technical research and development costreduction pathways related to the device technology rather than environmental monitoring or permitting opportunities. Three sources of information were used to understand current cost drivers and develop a prioritized list of potential cost reduction pathways: a literature review of technical work related to attenuators, a reference device compiled from literature sources, and a webinar with each of three industry device developers. Data from these information sources were aggregated and prioritized with respect to the potential impact on the lifetime levelized cost of energy, the potential for progress, the potential for success, and the confidence in success. Results indicate the five most promising cost reduction pathways include advanced controls, an optimized structural design, improved power conversion, planned maintenance scheduling, and an optimized device profile.

Bull, Diana L↗

Biological Optimization in Volumetric Modulated Arc Radiotherapy for Prostate Carcinoma

Purpose: To investigate the potential benefits achievable with biological optimization for modulated volumetric arc (VMAT) treatments of prostate carcinoma. Methods and Materials: Fifteen prostate patient plans were studied retrospectively. For each case, planning target volume, rectum, and bladder were considered. Three optimization schemes were used: dose-volume histogram (DVH) based, generalized equivalent uniform dose (gEUD) based, and mixed DVH/gEUD based. For each scheme, a single or dual 6-MV, 356 Degree-Sign VMAT arc was used. The plans were optimized with Pinnacle{sup 3} (v. 9.0 beta) treatment planning system. For each patient, the optimized dose distributions were normalized to deliver the same prescription dose. The quality of the plans was evaluated by dose indices (DIs) and gEUDs for rectum and bladder. The tallied DIs were D{sub 1%}, D{sub 15%}, D{sub 25%}, and D{sub 40%}, and the tallied gEUDs were for a values of 1 and 6. Statistical tests were used to quantify the magnitude and the significance of the observed differences. Monitor units and treatment times for each optimization scheme were also assessed. Results: All optimization schemes generated clinically acceptable plans. The statistical tests indicated that biological optimization yielded increased organs-at-risk sparing, ranging from {approx}1% to more than {approx}27% depending on the tallied DI, gEUD, and anatomical structure. The increased sparing was at the expense of longer treatment times and increased number of monitor units. Conclusions: Biological optimization can significantly increase the organs-at-risk sparing in VMAT optimization for prostate carcinoma. In some particular cases, however, the DVH-based optimization resulted in superior treatment plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-19A-12: Split-Ring Applicator with Interstitial Needle for Improved Volumetric Coverage in HDR Brachytherapy for Cervical Cancer

Purpose: To evaluate volumetric coverage of a Mick Radionuclear titanium Split-Ring applicator (SRA) with/without interstitial needle compared to an intracavitary Vienna applicator (VA), interstitial-intracavitary VA, and intracavitary ring and tandem applicator (RTA). Methods: A 57 year-old female with FIGO stage IIB cervical carcinoma was treated following chemoradiotherapy (45Gy pelvic and 5.4Gy parametrial boost) with highdose- rate (HDR) brachytherapy to 30Gy in 5 fractions using a SRA. A single interstitial needle was placed using the Ellis Interstitial Cap for the final three fractions to increase coverage of left-sided gross residual disease identified on 3T-MRI. High-risk (HR) clinical target volume (CTV) and intermediate-risk (IR) CTV were defined using axial T2-weighted 2D and 3D MRI sequences (Philips PET/MRI unit). Organs-at-risks (OARs) were delineated on CT. Oncentra planning system was used for treatment optimization satisfying GEC-ESTRO guidelines for target coverage and OAR constraints. Retrospectively, treatment plans (additional 20 plans) were simulated using intracavitary SRA (without needle), intracavitary VA (without needle), interstitial-intracavitary VA, and intracavitary RTA with this same patient case. Plans were optimized for each fraction to maintain coverage to HR-CTV. Results: Interstitial-intracavitary SRA achieved the following combined coverage for external radiation and brachytherapy (EQD2): D90 HR-CTV =94.6Gy; Bladder-2cc =88.9Gy; Rectum-2cc =65.1Gy; Sigmoid-2cc =48.9Gy; Left vaginal wall (VW) =103Gy, Right VW =99.2Gy. Interstitial-intracavitary VA was able to achieve identical D90 HR-CTV =94.6Gy, yet Bladder-2cc =91.9Gy (exceeding GEC-ESTRO recommendations of 2cc<90Gy) and Left VW =120.8Gy and Right VW =115.5Gy. Neither the SRA nor VA without interstitial needle could cover HR-CTV adequately without exceeding dose to Bladder-2cc. Conventional RTA was unable to achieve target coverage for the HR-CTV >80Gy without severely overdosing OARs. Conclusion: The Ellis Interstitial Cap for the SRA offered superior dosimetric coverage as compared to the interstitialintracavitary VA. This represents the first reported use for this devise, and further investigation is warranted.

60 APPLIED LIFE SCIENCES↗

A framework and tool for designing cost-effective, resilient, and circular net-zero supply chains under uncertainty with an application to multilayer plastic films

While 55% of Fortune 500 companies have committed to achieving net-zero emissions and/or zero-waste operations by 2035, only 2% are currently on track, revealing a critical gap between ambition and action. Designing supply chains that reduce both emissions and waste is a complex non-intuitive, multi-objective challenge, compounded by the high costs of new technologies and the need for resilient, profitable solutions. This paper aims to address this challenge by presenting a generic framework and multi-objective optimization formulation for designing cost-effective, circular, and resilient supply chains under uncertainty, implemented through a user-friendly decision-support tool with intuitive data visualization capabilities, enabling communication of results to both technical and non-technical stakeholders. We demonstrate the application of this framework in the context of multilayer plastic films (barrier films), which are widely used in food packaging and composite materials. The model quantifies trade-offs across three objectives: minimizing global warming potential, maximizing circularity, and minimizing cost. A key contribution of this work is the explicit modeling of technological resilience, the ability of supply chains to maintain function under disruption. In the cost-minimization case, the resilience constraint makes the design approximately three times more expensive in the short-term metric, but shifts the system from relying on a single recovery pathway to a portfolio of four recovery pathways, improving the robustness of the optimization solution under uncertainty. Lastly, we introduce TranZero, a decision-support tool that integrates material flow analysis, hotspot identification, and optimization-based scenario planning to support net-zero and circularity decisions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A planning study investigating dual-gated volumetric arc stereotactic treatment of primary renal cell carcinoma

This is a planning study investigating the dosimetric advantages of gated volumetric-modulated arc therapy (VMAT) to the end-exhale and end-inhale breathing phases for patients undergoing stereotactic treatment of primary renal cell carcinoma. VMAT plans were developed from the end-inhale (VMATinh) and the end-exhale (VMATexh) phases of the breathing cycle as well as a VMAT plan and 3-dimensional conformal radiation therapy plan based on an internal target volume (ITV) (VMATitv). An additional VMAT plan was created by giving the respective gated VMAT plan a 50% weighting and summing the inhale and exhale plans together to create a summed gated plan. Dose to organs at risk (OARs) as well as comparison of intermediate and low-dose conformity was evaluated. There was no difference in the volume of healthy tissue receiving the prescribed dose for the planned target volume (PTV) (CI100%) for all the VMAT plans; however, the mean volume of healthy tissue receiving 50% of the prescribed dose for the PTV (CI50%) values were 4.7 (± 0.2), 4.6 (± 0.2), and 4.7 (± 0.6) for the VMATitv, VMATinh, and VMATexh plans, respectively. The VMAT plans based on the exhale and inhale breathing phases showed a 4.8% and 2.4% reduction in dose to 30 cm{sup 3} of the small bowel, respectively, compared with that of the ITV-based VMAT plan. The summed gated VMAT plans showed a 6.2% reduction in dose to 30 cm{sup 3} of the small bowel compared with that of the VMAT plans based on the ITV. Additionally, when compared with the inhale and the exhale VMAT plans, a 4% and 1.5%, respectively, reduction was observed. Gating VMAT was able to reduce the amount of prescribed, intermediate, and integral dose to healthy tissue when compared with VMAT plans based on an ITV. When summing the inhale and exhale plans together, dose to healthy tissue and OARs was optimized. However, gating VMAT plans would take longer to treat and is a factor that needs to be considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using neural networks and Dyna algorithm for integrated planning, reacting and learning in systems

The traditional AI answer to the decision making problem for a robot is planning. However, planning is usually CPU-time consuming, depending on the availability and accuracy of a world model. The Dyna system generally described in earlier work, uses trial and error to learn a world model which is simultaneously used to plan reactions resulting in optimal action sequences. It is an attempt to integrate planning, reactive, and learning systems. The architecture of Dyna is presented. The different blocks are described. There are three main components of the system. The first is the world model used by the robot for internal world representation. The input of the world model is the current state and the action taken in the current state. The output is the corresponding reward and resulting state. The second module in the system is the policy. The policy observes the current state and outputs the action to be executed by the robot. At the beginning of program execution, the policy is stochastic and through learning progressively becomes deterministic. The policy decides upon an action according to the output of an evaluation function, which is the third module of the system. The evaluation function takes the following as input: the current state of the system, the action taken in that state, the resulting state, and a reward generated by the world which is proportional to the current distance from the goal state. Originally, the work proposed was as follows: (1) to implement a simple 2-D world where a 'robot' is navigating around obstacles, to learn the path to a goal, by using lookup tables; (2) to substitute the world model and Q estimate function Q by neural networks; and (3) to apply the algorithm to a more complex world where the use of a neural network would be fully justified. In this paper, the system design and achieved results will be described. First we implement the world model with a neural network and leave Q implemented as a look up table. Next, we use a lookup table for the world model and implement the Q function with a neural net. Time limitations prevented the combination of these two approaches. The final section discusses the results and gives clues for future work.

Lima, Pedro↗

Supporting the Transition from Grid-Scale to Emerging Market Wave Energy Converter Design and Assessment

In the past decade there has been increasing interest in emerging markets for wave energy, both as a stepping stone for development and as a way to create new opportunities for offshore markets such as ocean observation or desalination. Developers who were once focused exclusively on grid-scale development have begun to engage with more unique markets. This has led researchers to begin examining means of assessing emerging-market devices. In this paper, we analyze the Technology Performance Level (TPL) Assessment for its potential use in the assessment of emerging market wave energy converters (EM-WECs). We use Quality Function Deployment (QFD) and a question-by-question analysis of the TPL assessment to determine the changes necessary for such an assessment to be applicable in emerging markets. We discuss how the primary differences between the markets could impact the viable development pathways for developers hoping to succeed in multiple markets. We determine that the different stakeholders and stakeholder requirements of some emerging markets compared to gridscale applications should be met with changes to cost-toperformance metrics, prototype testing processes, recovery planning, materials selection, optimization objectives, and public engagement.

blue economy↗

Automated treatment planning for a dedicated multi-source intracranial radiosurgery treatment unit using projected gradient and grassfire algorithms

Purpose: The purpose of this work is to develop a framework to the inverse problem for radiosurgery treatment planning on the Gamma Knife{sup Registered-Sign} Perfexion Trade-Mark-Sign (PFX) for intracranial targets. Methods: The approach taken in the present study consists of two parts. First, a hybrid grassfire and sphere-packing algorithm is used to obtain shot positions (isocenters) based on the geometry of the target to be treated. For the selected isocenters, a sector duration optimization (SDO) model is used to optimize the duration of radiation delivery from each collimator size from each individual source bank. The SDO model is solved using a projected gradient algorithm. This approach has been retrospectively tested on seven manually planned clinical cases (comprising 11 lesions) including acoustic neuromas and brain metastases. Results: In terms of conformity and organ-at-risk (OAR) sparing, the quality of plans achieved with the inverse planning approach were, on average, improved compared to the manually generated plans. The mean difference in conformity index between inverse and forward plans was -0.12 (range: -0.27 to +0.03) and +0.08 (range: 0.00-0.17) for classic and Paddick definitions, respectively, favoring the inverse plans. The mean difference in volume receiving the prescribed dose (V{sub 100}) between forward and inverse plans was 0.2% (range: -2.4% to +2.0%). After plan renormalization for equivalent coverage (i.e., V{sub 100}), the mean difference in dose to 1 mm{sup 3} of brainstem between forward and inverse plans was -0.24 Gy (range: -2.40 to +2.02 Gy) favoring the inverse plans. Beam-on time varied with the number of isocenters but for the most optimal plans was on average 33 min longer than manual plans (range: -17 to +91 min) when normalized to a calibration dose rate of 3.5 Gy/min. In terms of algorithm performance, the isocenter selection for all the presented plans was performed in less than 3 s, while the SDO was performed in an average of 215 min. Conclusions: PFX inverse planning can be performed using geometric isocenter selection and mathematical modeling and optimization techniques. The obtained treatment plans all meet or exceed clinical guidelines while displaying high conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Autonomous path-planning for formation flying-applications

The paper presents a solution to the optimal formation path-planning problem where the formation reconfigurations are required subject to collision avoidance and resource limitation contraints.

formation flying collision-avoidance path-planning↗