Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “movement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Context-dependent arm pointing adaptation

We sought to determine the effectiveness of head posture as a contextual cue to facilitate adaptive transitions in manual control during visuomotor distortions. Subjects performed arm pointing movements by drawing on a digitizing tablet, with targets and movement trajectories displayed in real time on a computer monitor. Adaptation was induced by presenting the trajectories in an altered gain format on the monitor. The subjects were shown visual displays of their movements that corresponded to either 0.5 or 1.5 scaling of the movements made. Subjects were assigned to three groups: the head orientation group tilted the head towards the right shoulder when drawing under a 0.5 gain of display and towards the left shoulder when drawing under a 1.5 gain of display; the target orientation group had the home and target positions rotated counterclockwise when drawing under the 0.5 gain and clockwise for the 1.5 gain; the arm posture group changed the elbow angle of the arm they were not drawing with from full flexion to full extension with 0.5 and 1.5 gain display changes. To determine if contextual cues were associated with display alternations, the gain changes were returned to the standard (1.0) display. Aftereffects were assessed to determine the efficacy of the head orientation contextual cue compared to the two control cues. The head orientation cue was effectively associated with the multiple gains. The target orientation cue also demonstrated some effectiveness while the arm posture cue did not. The results demonstrate that contextual cues can be used to switch between multiple adaptive states. These data provide support for the idea that static head orientation information is a crucial component to the arm adaptation process. These data further define the functional linkage between head posture and arm pointing movements.

Clinical Trial↗

Cystathionine gamma lyase-H2S contributes to osteoclastogenesis during bone remodeling induced by mechanical loading

Highlights: • This study investigated the role of H{sub 2}S and osteoclastogenesis in bone remodeling induced by mechanical loading in mice. • CSE-H{sub 2}S was a dominant H{sub 2}S generating system in osteoclasts, while CBS did not generate H{sub 2}S. • In CSE-deficient mice, osteoclastogenesis and tooth movement were inhibited, which could be rescued by a H{sub 2}S donor. Hydrogen sulfide (H{sub 2}S), a gaseous signaling molecule produced by cystathionine γ-lyase (CSE) and cystathionine β-synthase (CBS), influences bone remodeling in many ways. Osteoclasts play an important role in bone remodeling during tooth movement induced by mechanical loading, which increases the rate of tooth movement. Recently, we found that osteoclasts could produce H{sub 2}S. However, whether H{sub 2}S modulates bone remodeling by affecting osteoclasts remains unclear. In this study, we found that CSE-H{sub 2}S was a dominant H{sub 2}S generating system in osteoclasts, while CBS did not generate H{sub 2}S. A significant increase in CSE mRNA expression and H{sub 2}S production was observed in periodontal ligament (PDL) tissues of wild-type (WT) mice after 3 days of mechanical loading. CSE gene knockout led to a significant reduction in the number of maxillary osteoclasts and in the amount of tooth movement. The number of RANKL-induced TRAP-positive osteoclasts and the mRNA expression of osteoclast markers were downregulated after 6 days of incubation in monocytes extracted from CSE{sup −/−} mice. The expression of IL-1, IL-6 and TNF-α, which can stimulate osteoclastogenesis in periodontal tissue and serum samples, was lower in CSE{sup −/−} mice after mechanical loading. Application of the H{sub 2}S donor GYY4137 increased the number of RANKL-induced osteoclasts, the number of osteoclasts in periodontal tissues and tooth movement distance in CSE{sup −/−} mice. The results suggested that endogenous H{sub 2}S and CSE play vital roles in the osteoclastogenesis and alveolar bone resorption induced by mechanical loading.

60 APPLIED LIFE SCIENCES↗

Nuclear speed and cycle length co-vary with local density during syncytial blastoderm formation in a cricket

Abstract The blastoderm is a broadly conserved stage of early animal development, wherein cells form a layer at the embryo’s periphery. The cellular behaviors underlying blastoderm formation are varied and poorly understood. In most insects, the pre-blastoderm embryo is a syncytium: nuclei divide and move throughout the shared cytoplasm, ultimately reaching the cortex. In Drosophila melanogaster , some early nuclear movements result from pulsed cytoplasmic flows that are coupled to synchronous divisions. Here, we show that the cricket Gryllus bimaculatus has a different solution to the problem of creating a blastoderm. We quantified nuclear dynamics during blastoderm formation in G. bimaculatus embryos, finding that: (1) cytoplasmic flows are unimportant for nuclear movement, and (2) division cycles, nuclear speeds, and the directions of nuclear movement are not synchronized, instead being heterogeneous in space and time. Moreover, nuclear divisions and movements co-vary with local nuclear density. We show that several previously proposed models for nuclear movements in D. melanogaster cannot explain the dynamics of G. bimaculatus nuclei. We introduce a geometric model based on asymmetric pulling forces on nuclei, which recapitulates the patterns of nuclear speeds and orientations of both unperturbed G. bimaculatus embryos, and of embryos physically manipulated to have atypical nuclear densities.

59 BASIC BIOLOGICAL SCIENCES↗

Network-Level Traffic Signal Cooperation: A Higher-Order Conflict Graph Approach

Traffic signal control and cooperation are extremely important to alleviate traffic congestion in a large traffic network. This study develops a higher-order conflict graph approach for network-wide traffic signal control and cooperation. A conflict graph is applied to model the traffic signal configurations, which identifies the conflict and unconflicted movements for each intersection. In conflict graph, the node represents each movement. The weight of each node can be defined as traffic volume, queue length, fuel consumption, or any weighted combinations of these measurements. The calculation of the optimal green light duration and green light sequence (for different movements) is equivalent to sequentially finding the maximum weight independent set (MWIS) in the conflict graph. The conflict graph also provides a uniform and efficient way to connect traffic signal operations among nearby intersections spatially. Then, we introduced the concept of the k -th order neighborhood to model the degree of connectivity between each movement to the movements at upstream or downstream intersections. The weight of each node in the higher-order conflict graph not only represents its own congestion level, but also relates to the traffic conditions of nearby intersections. Through this approach, the cooperation of multiple intersections can be realized by incorporating their spatial connectivity into conflict graph and solving the MWIS problem. A simulation network is built in SUMO to test the effectiveness of the proposed method. Results suggested that the proposed model outperformed other state-of-the-art signal control methods. Also, the scheme maintains good performance under varying traffic demands.

42 ENGINEERING↗

Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial and dose–response analysis of fibrotic lung changes after stereotactic body radiation therapy

Purpose: Stereotactic body radiation therapy (SBRT) is becoming the standard of care for early stage nonoperable lung cancers. Accurate dose–response modeling is challenging for SBRT because of the decreased number of clinical toxicity events. As a surrogate for a clinical toxicity endpoint, studies have proposed to use radiographic changes in follow up computed tomography (CT) scans to evaluate lung SBRT normal tissue effects. The purpose of the current study was to use local fibrotic lung regions to spatially and dosimetrically evaluate lung changes in patients that underwent SBRT.Methods: Forty seven SBRT patients treated at our institution from 2003 to 2009 were used for the current study. Our patient cohort had a total of 148 follow up CT scans ranging from 3 to 48 months post-therapy. Post-treatment scans were binned into intervals of 3, 6, 12, 18, 24, 30, and 36 months after the completion of treatment. Deformable image registration was used to align the follow up CT scans with the pretreatment CT and dose distribution. Areas of visible fibrotic changes were contoured. The centroid of each gross tumor volume (GTV) and contoured fibrosis volume was calculated and the fibrosis volume location and movement (magnitude and direction) relative to the GTV and 30 Gy isodose centroid were analyzed. To perform a dose–response analysis, each voxel in the fibrosis volume was sorted into 10 Gy dose bins and the average CT number value for each dose bin was calculated. Dose–response curves were generated by plotting the CT number as a function of dose bin and time posttherapy.Results: Both fibrosis and GTV centroids were concentrated in the upper third of the lung. The average radial movement of fibrosis centroids relative to the GTV centroids was 2.6 cm with movement greater than 5 cm occurring in 11% of patients. Evaluating dose–response curves revealed an overall trend of increasing CT number as a function of dose. The authors observed a CT number plateau at doses ranging from 30 to 50 Gy for the 3, 6, and 12 months posttherapy time points. There was no evident plateau for the dose–response curves generated using data from the 18, 24, 30, and 36 months posttherapy time points.Conclusions: Regions of local fibrotic lung changes in patients that underwent SBRT were evaluated spatially and dosimetrically. The authors found that the average fibrosis movement was 2.6 cm with movement greater than 5 cm possible. Evaluating dose–response curves revealed an overall trend of increasing CT number as a function of dose. Furthermore, our dose–response data also suggest that one of the possible explanations of the CT number plateau effect may be the time posttherapy of the acquired data. Understanding normal tissue dose–response is important for reducing toxicity after SBRT, especially in cases where larger tumors are treated. The methods presented in the current work build on prior quantitative studies and further enhance the understanding of normal lung dose–response after SBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-281: Dose Measurements of Modulated Spot-Scanning Particle Beams with Beam-Gating of Respiratory-Phase

Purpose: To present dosimetric variations due to target movements with beam-gating windows of various respiratory-phase in homogeneous phantom irradiated by modulated spot-scanning carbon-ions and protons in Siemens IONTRIS system. Methods: For the safety and efficacy of proton therapy to treat three patients with lung cancer during our clinical trial, residual motion was required within 5mm. To study dosimetric variations due to respiratory movement, a target of 4.0cmx4.0cm with 2cm thick was moved with distances of 3.5mm, 4.4mm, 6.0mm, 8.3mm, and 11.0mm with beam-gating windows between various phases of inhalation or exhalation at a sin-wave breathing pattern. The target was irritated at 110mm depth by modulated carbon-ions with focus sizes of 4.1mm to 4.6mm, and a grid size of 1mm between spots. And, by modulated protons with focus sizes of 11.4mm to 13.6mm, and a grid size of 1.9mm between spots. A 4.0cmx4.0cm field size was used for both beams. EBT3 films was placed at the center of target for measurements. Delivery dose was 5.0 Gy with >1.0% uniformity over target. The uniformity and field size of each measured 2D lateral profiles were extracted. Results: By irradiating films to a doses at linear region of dose response, the uniformity and field size were extracted by measured optical density. The measured deviations from calculated field width and dose increase with increased motion amplitude. Larger non-uniformity was observed for carbonion with smaller focus size in comparing with protons. For movements of 4.4mm and 6.0mm, Optical Density uniformity of 3.80% and 5.66%were observed for carbon beam. But, is 3.46% for protons with 11.4mm movement. Conclusion: Our investigations showed that 5% optical density uniformity for carbon-ions and protons might be acceptable for treatments with 8.3mm movements in homogeneous phantoms. Dose variation introduced in complex anatomy of real patients need further investigation.

60 APPLIED LIFE SCIENCES↗

Satellite animal tracking feasibility studies

A study was initiated in Tsavo National Park to determine movements and home ranges of individual elephants and their relations to overall distribution patterns and environmental factors such as rainfall. Methods used were radio tracking and observations of visually identifiable individuals. Aerial counts provided data on overall distribution. Two bulls and two cows were radio-tagged in Tsavo West and two bulls and four cows in Tsavo East, providing home range and movement data. The movements of individuals were useful in interpreting relatively major shifts in elephant distribution. Results point to the following preliminary conclusions: (1) elephants in the Tsavo area undertook long distance movements in fairly direct response to localized rainfall; (2) a subdivision of the overall population into locally distinct units may exist during the dry season but did not occur after significant rainfall; and (3) food appears to be the primary factor governing movements and distribution of elephants in the area.

Buechner, H. K.↗

The Interaction of Calcium and Auxin in the Gravitropic Response of Roots

The role of calcium redistribution in the responding region of the root is examined, however, the potential connection between calcium and auxin redistribution in the elongation zone is not found. The following items are examined: (1) the effect of gravity on calcium movement across the elongation zone; (2) the effect of gravity on auxin movement across the elongation zone; and (3) the effect of calcium on auxin movement across the elongation zone. It is indicated that gravistimulation induces a physiological asymmetry in the auxin transport system of maize roots and that calcium increases the total transport of auxin across the root. Gravistimulation is apparently necessary for the enhancing effect of calcium on lateral auxin movement, and it is possible that the preferential downward movement of calcium across the elongation zone of gravistimulated roots plays a role in establishing the auxin asymmetry proposed to cause positive gravitropic curvature.

Evans, M. L.↗

A Study of Air Flow in an Engine Cylinder

A 4-stroke-cycle test engine was equipped with a glass cylinder and the air movements within it were studied while the engine was being motored. Different types of air flow were produced by using shrouded intake valves in various arrangements and by altering the shape of the intake-air passage in the cylinder head. The air movements were made visible by mixing feathers with the entering air, and high-speed motion pictures were taken of them so that the air currents might be studied in detail and their velocities measured. Motion pictures were also taken of gasoline sprays injected into the cylinder on the intake stroke. The photographs showed that: a wide variety of induced air movements could be created in the cylinder; the movements always persisted throughout the compression stroke; and the only type of movement that persisted until the end of the cycle was rotation about the cylinder axis.

Lee, Dana W↗

Otolith and Vertical Canal Contributions to Dynamic Postural Control

The objective of this project is to determine: 1) how do normal subjects adjust postural movements in response to changing or altered otolith input, for example, due to aging? and 2) how do patients adapt postural control after altered unilateral or bilateral vestibular sensory inputs such as ablative inner ear surgery or ototoxicity, respectively? The following hypotheses are under investigation: 1) selective alteration of otolith input or abnormalities of otolith receptor function will result in distinctive spatial, frequency, and temporal patterns of head movements and body postural sway dynamics. 2) subjects with reduced, altered, or absent vertical semicircular canal receptor sensitivity but normal otolith receptor function or vice versa, should show predictable alterations of body and head movement strategies essential for the control of postural sway and movement. The effect of altered postural movement control upon compensation and/or adaptation will be determined. These experiments provide data for the development of computational models of postural control in normals, vestibular deficient subjects and normal humans exposed to unusual force environments, including orbital space flight.

Black, F. Owen↗

Assembly For Moving a Robotic Device Along Selected Axes

An assembly for moving a robotic device along selected axes includes a programmable logic controller (PLC) for controlling movement of the device along selected axes to effect movement of the device to a selected disposition. The PLC includes a plurality of single axis motion control modules, and a central processing unit (CPU) in communication with the motion control modules. A human-machine interface is provided for operator selection of configurations of device movements and is in communication with the CPU. A motor drive is in communication with each of the motion control modules and is operable to effect movement of the device along the selected axes to obtain movement of the device to the selected disposition.

Brentley Craig Nowlin↗

The Right Track for Vision Correction

More and more people are putting away their eyeglasses and contact lenses as a result of laser vision correction surgery. LASIK, the most widely performed version of this surgical procedure, improves vision by reshaping the cornea, the clear front surface of the eye, using an excimer laser. One excimer laser system, Alcon s LADARVision 4000, utilizes a laser radar (LADAR) eye tracking device that gives it unmatched precision. During LASIK surgery, laser During LASIK surgery, laser pulses must be accurately placed to reshape the cornea. A challenge to this procedure is the patient s constant eye movement. A person s eyes make small, involuntary movements known as saccadic movements about 100 times per second. Since the saccadic movements will not stop during LASIK surgery, most excimer laser systems use an eye tracking device that measures the movements and guides the placement of the laser beam. LADARVision s eye tracking device stems from the LADAR technology originally developed through several Small Business Innovation Research (SBIR) contracts with NASA s Johnson Space Center and the U.S. Department of Defense s Ballistic Missile Defense Office (BMDO). In the 1980s, Johnson awarded Autonomous Technologies Corporation a Phase I SBIR contract to develop technology for autonomous rendezvous and docking of space vehicles to service satellites. During Phase II of the Johnson SBIR contract, Autonomous Technologies developed a prototype range and velocity imaging LADAR to demonstrate technology that could be used for this purpose.

Source record↗

Vestibular convergence patterns in vestibular nuclei neurons of alert primates

Sensory signal convergence is a fundamental and important aspect of brain function. Such convergence may often involve complex multidimensional interactions as those proposed for the processing of otolith and semicircular canal (SCC) information for the detection of translational head movements and the effective discrimination from physically congruent gravity signals. In the present study, we have examined the responses of primate rostral vestibular nuclei (VN) neurons that do not exhibit any eye movement-related activity using 0.5-Hz translational and three-dimensional (3D) rotational motion. Three distinct neural populations were identified. Approximately one-fourth of the cells exclusively encoded rotational movements (canal-only neurons) and were unresponsive to translation. The canal-only central neurons encoded head rotation in SCC coordinates, exhibited little orthogonal canal convergence, and were characterized with significantly higher sensitivities to rotation as compared to primary SCC afferents. Another fourth of the neurons modulated their firing rates during translation (otolith-only cells). During rotations, these neurons only responded when the axis of rotation was earth-horizontal and the head was changing orientation relative to gravity. The remaining one-half of VN neurons were sensitive to both rotations and translations (otolith + canal neurons). Unlike primary otolith afferents, however, central neurons often exhibited significant spatiotemporal (noncosine) tuning properties and a wide variety of response dynamics to translation. To characterize the pattern of SCC inputs to otolith + canal neurons, their rotational maximum sensitivity vectors were computed using exclusively responses during earth-vertical axis rotations (EVA). Maximum sensitivity vectors were distributed throughout the 3D space, suggesting strong convergence from multiple SCCs. These neurons were also tested with earth-horizontal axis rotations (EHA), which would activate both vertical canals and otolith organs. However, the recorded responses could not be predicted from a linear combination of EVA rotational and translational responses. In contrast, one-third of the neurons responded similarly during EVA and EHA rotations, although a significant response modulation was present during translation. Thus this subpopulation of otolith + canal cells, which included neurons with either high- or low-pass dynamics to translation, appear to selectively ignore the component of otolith-selective activation that is due to changes in the orientation of the head relative to gravity. Thus contrary to primary otolith afferents and otolith-only central neurons that respond equivalently to tilts relative to gravity and translational movements, approximately one-third of the otolith + canal cells seem to encode a true estimate of the translational component of the imposed passive head and body movement.

Non-NASA Center↗

Tactile responses in the granule cell layer of cerebellar folium crus IIa of freely behaving rats

We recorded activity from the granule cell layer (GCL) of cerebellar folium Crus IIa as freely moving rats engaged in a variety of natural behaviors, including grooming, eating, and free tactile exploration. Multiunit responses in the 1000-4500 Hz range were found to be strongly correlated with tactile stimulation of lip and whisker (perioral) regions. These responses occurred regardless of whether the stimulus was externally or self-generated and during both active and passive touch. In contrast, perioral movements that did not tactually stimulate this region of the face (e.g., chewing) produced no detectable increases in GCL activity. In addition, GCL responses were not correlated with movement extremes. When rats used their lips actively for palpation and exploration, the tactile responses in the GCL were not detectably modulated by ongoing jaw movements. However, active palpation and exploratory behaviors did result in the largest and most continuous bursts of GCL activity: responses were on average 10% larger and 50% longer during palpation and exploration than during grooming or passive stimulation. Although activity levels differed between behaviors, the position and spatial extent of the peripheral receptive field was similar over all behaviors that resulted in tactile input. Overall, our data suggest that the 1000-4500 Hz multiunit responses in the Crus IIa GCL of awake rats are correlated with tactile input rather than with movement or any movement parameter and that these responses are likely to be of particular importance during the acquisition of sensory information by perioral structures.

Neurons/cytology/physiology↗

Interaction of the body, head, and eyes during walking and turning

Body, head, and eye movements were measured in five subjects during straight walking and while turning corners. The purpose was to determine how well the head and eyes followed the linear trajectory of the body in space and whether head orientation followed changes in the gravito-inertial acceleration vector (GIA). Head and body movements were measured with a video-based motion analysis system and horizontal, vertical, and torsional eye movements with video-oculography. During straight walking, there was lateral body motion at the stride frequency, which was at half the frequency of stepping. The GIA oscillated about the direction of heading, according to the acceleration and deceleration associated with heel strike and toe flexion, and the body yawed in concert with stepping. Despite the linear and rotatory motions of the head and body, the head pointed along the forward motion of the body during straight walking. The head pitch/roll component appeared to compensate for vertical and horizontal acceleration of the head rather than orienting to the tilt of the GIA or anticipating it. When turning corners, subjects walked on a 50-cm radius over two steps or on a 200-cm radius in five to seven steps. Maximum centripetal accelerations in sharp turns were ca.0.4 g, which tilted the GIA ca.21 degrees with regard to the heading. This was anticipated by a roll tilt of the head of up to 8 degrees. The eyes rolled 1-1.5 degrees and moved down into the direction of linear acceleration during the tilts of the GIA. Yaw head deviations moved smoothly through the turn, anticipating the shift in lateral body trajectory by as much as 25 degrees. The trunk did not anticipate the change in trajectory. Thus, in contrast to straight walking, the tilt axes of the head and the GIA tended to align during turns. Gaze was stable in space during the slow phases and jumped forward in saccades along the trajectory, leading it by larger angles when the angular velocity of turning was greater. The anticipatory roll head movements during turning are likely to be utilized to overcome inertial forces that would destabilize balance during turning. The data show that compensatory eye, head, and body movements stabilize gaze during straight walking, while orienting mechanisms direct the eyes, head, and body to tilts of the GIA in space during turning.

Non-NASA Center↗

Artificial gravity as a countermeasure in long-duration space flight

Long-duration exposure to weightlessness results in bone demineralization, muscle atrophy, cardiovascular deconditioning, altered sensory-motor control, and central nervous system reorganizations. Exercise countermeasures and body loading methods so far employed have failed to prevent these changes. A human mission to Mars might last 2 or 3 years and without effective countermeasures could result in dangerous levels of bone and muscle loss. Artificial gravity generated by rotation of an entire space vehicle or of an inner chamber could be used to prevent structural changes. Some of the physical characteristics of rotating environments are outlined along with their implications for human performance. Artificial gravity is the centripetal force generated in a rotating vehicle and is proportional to the product of the square of angular velocity and the radius of rotation. Thus, for a particular g-level, there is a tradeoff between velocity of rotation and radius. Increased radius is vastly more expensive to achieve than velocity, so it is important to know the highest rotation rates to which humans can adapt. Early studies suggested that 3 rpm might be the upper limit because movement control and orientation were disrupted at higher velocities and motion sickness and chronic fatigue were persistent problems. Recent studies, however, are showing that, if the terminal velocity is achieved over a series of gradual steps and many body movements are made at each dwell velocity, then full adaptation of head, arm, and leg movements is possible. Rotation rates as high as 7.5-10 rpm are likely feasible. An important feature of the new studies is that they provide compelling evidence that equilibrium point theories of movement control are inadequate. The central principles of equilibrium point theories lead to the equifinality prediction, which is violated by movements made in rotating reference frames. Copyright 2000 Wiley-Liss, Inc.

Review Literature↗

Primate translational vestibuloocular reflexes. II. Version and vergence responses to fore-aft motion

To maintain binocular fixation on near targets during fore-aft translational disturbances, largely disjunctive eye movements are elicited the amplitude and direction of which should be tuned to the horizontal and vertical eccentricities of the target. The eye movements generated during this task have been investigated here as trained rhesus monkeys fixated isovergence targets at different horizontal and vertical eccentricities during 10 Hz fore-aft oscillations. The elicited eye movements complied with the geometric requirements for binocular fixation, although not ideally. First, the corresponding vergence angle for which the movement of each eye would be compensatory was consistently less than that dictated by the actual fixation parameters. Second, the eye position with zero sensitivity to translation was not straight ahead, as geometrically required, but rather exhibited a systematic dependence on viewing distance and vergence angle. Third, responses were asymmetric, with gains being larger for abducting and downward compared with adducting and upward gaze directions, respectively. As frequency was varied between 4 and 12 Hz, responses exhibited high-pass filter properties with significant differences between abduction and adduction responses. As a result of these differences, vergence sensitivity increased as a function of frequency with a steeper slope than that of version. Despite largely undercompensatory version responses, vergence sensitivity was closer to ideal. Moreover, the observed dependence of vergence sensitivity on vergence angle, which was varied between 2.5 and 10 MA, was largely linear rather than quadratic (as geometrically predicted). We conclude that the spatial tuning of eye velocity sensitivity as a function of gaze and viewing distance follows the general geometric dependencies required for the maintenance of foveal visual acuity. However, systematic deviations from ideal behavior exist that might reflect asymmetric processing of abduction/adduction responses perhaps because of different functional dependencies of version and vergence eye movement components during translation.

NASA Program Biomedical Research and Countermeasur↗