Engineering PapersSearch

NASA NTRS · 20040112596

Context-dependent arm pointing adaptation

Abstract

We sought to determine the effectiveness of head posture as a contextual cue to facilitate adaptive transitions in manual control during visuomotor distortions. Subjects performed arm pointing movements by drawing on a digitizing tablet, with targets and movement trajectories displayed in real time on a computer monitor. Adaptation was induced by presenting the trajectories in an altered gain format on the monitor. The subjects were shown visual displays of their movements that corresponded to either 0.5 or 1.5 scaling of the movements made. Subjects were assigned to three groups: the head orientation group tilted the head towards the right shoulder when drawing under a 0.5 gain of display and towards the left shoulder when drawing under a 1.5 gain of display; the target orientation group had the home and target positions rotated counterclockwise when drawing under the 0.5 gain and clockwise for the 1.5 gain; the arm posture group changed the elbow angle of the arm they were not drawing with from full flexion to full extension with 0.5 and 1.5 gain display changes. To determine if contextual cues were associated with display alternations, the gain changes were returned to the standard (1.0) display. Aftereffects were assessed to determine the efficacy of the head orientation contextual cue compared to the two control cues. The head orientation cue was effectively associated with the multiple gains. The target orientation cue also demonstrated some effectiveness while the arm posture cue did not. The results demonstrate that contextual cues can be used to switch between multiple adaptive states. These data provide support for the idea that static head orientation information is a crucial component to the arm adaptation process. These data further define the functional linkage between head posture and arm pointing movements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Seidler, R. D., Bloomberg, J. J., Stelmach, G. E.. 2001-03-15. Context-dependent arm pointing adaptation. https://ntrs.nasa.gov/citations/20040112596

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Intensive exercise training suppresses testosterone during bed rest

Spaceflight and prolonged bed rest (BR) alter plasma hormone levels inconsistently. This may be due, in part, to prescription of heavy exercise as a countermeasure for ameliorating the adverse effects of disuse. The initial project was to assess exercise programs to maintain aerobic performance and leg strength during BR. The present study evaluates the effect of BR and the performance of the prescribed exercise countermeasures on plasma steroid levels. In a 30-day BR study of male subjects, the efficacy of isotonic (ITE, n = 7) or isokinetic exercise (IKE, n = 7) training was evaluated in contrast to no exercise (n = 5). These exercise countermeasures protected aerobic performance and leg strength successfully. BR alone (no-exercise group) did not change steroidogenesis, as assessed by the plasma concentrations of cortisol, progesterone, aldosterone, and free (FT) and total testosterone (TT). In the exercise groups, both FT and TT were decreased (P < 0.05): FT during IKE from 24 +/- 1.7 to 18 +/- 2.0 pg/ml and during ITE from 21 +/- 1.5 to 18 +/- 1 pg/ml, and TT during IKE from 748 +/- 68 to 534 +/- 46 ng/dl and during ITE from 565 +/- 36 to 496 +/- 38 ng/dl. The effect of intensive exercise countermeasures on plasma testosterone was not associated with indexes of overtraining. The reduction in plasma testosterone associated with both the IKE and ITE countermeasures during BR supports our hypothesis that intensive exercise countermeasures may, in part, contribute to changes in plasma steroid concentrations during spaceflight.

Clinical Trial

Using EMG to anticipate head motion for virtual-environment applications

In virtual environment (VE) applications, where virtual objects are presented in a see-through head-mounted display, virtual images must be continuously stabilized in space in response to user's head motion. Time delays in head-motion compensation cause virtual objects to "swim" around instead of being stable in space which results in misalignment errors when overlaying virtual and real objects. Visual update delays are a critical technical obstacle for implementing head-mounted displays in applications such as battlefield simulation/training, telerobotics, and telemedicine. Head motion is currently measurable by a head-mounted 6-degrees-of-freedom inertial measurement unit. However, even given this information, overall VE-system latencies cannot be reduced under about 25 ms. We present a novel approach to eliminating latencies, which is premised on the fact that myoelectric signals from a muscle precede its exertion of force, thereby limb or head acceleration. We thus suggest utilizing neck-muscles' myoelectric signals to anticipate head motion. We trained a neural network to map such signals onto equivalent time-advanced inertial outputs. The resulting network can achieve time advances of up to 70 ms.

Clinical Trial

Ocular examination for trauma; clinical ultrasound aboard the International Space Station

BACKGROUND: Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. METHODS: An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. RESULTS: A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. CONCLUSIONS: A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using remote guidance. Ocular ultrasound images were of diagnostic quality despite the 2-second communication latency and the unconventional setting of a weightless spacecraft environment. The remote guidance techniques developed to facilitate this successful NASA research experiment will support wider applications of ultrasound for remote medicine on Earth including the assessment of pupillary reactions in patients with severe craniofacial trauma and swelling.

Clinical Trial