Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TAPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Availability of Previously Unprocessed ALSEP Raw Instrument Data, Derivative Data, and Metadata Products

In year 2010, 440 original data archival tapes for the Apollo Lunar Science Experiment Package (ALSEP) experiments were found at the Washington National Records Center. These tapes hold raw instrument data received from the Moon for all the ALSEP instruments for the period of April through June 1975. We have recently completed extraction of binary files from these tapes, and we have delivered them to the NASA Space Science Data Cordinated Archive (NSSDCA). We are currently processing the raw data into higher order data products in file formats more readily usable by contemporary researchers. These data products will fill a number of gaps in the current ALSEP data collection at NSSDCA. In addition, we have estabilished a digital, searcheable archive of ALSEP document and metadata as part of the web portal of the Lunar and Planetary Institute. It currently holds approx. 700 documents totaling approx. 40,000 pages

ALSEP↗

Data Recovery Effort of Nimbus Era Observations by the NASA GES DISC

NASA launched seven Nimbus meteorological satellites in the 1960s and 70s. These satellites carried instruments for making observations of the Earth in the visible, infrared, ultraviolet, and microwave wavelengths. The original data archive consisted of a combination of magnetic tapes and various film media. As these media are well past their expected end of life, the valuable data they contain are now being migrated to the GES DISC modern online archive. The process involves recovering the digital data files from the tapes as well as scanning images of the data from film strips. This presentation will address the status and challenges of recovering the Nimbus data. The old data products were written on now obsolete hardware systems and outdated file formats. They lack any metadata standards and each product is often written in its own proprietary file structure. This requires creating metadata by reading the contents of the old data files. The job is tedious and laborious, as documentation may be incomplete, data files and tapes are sometimes corrupted, or were improperly copied at the time they were created.

Nimbus↗

Automated Fiber Placement Manufactured Composites for Science Applications

Science instruments with large collecting areas that maintain dimensional stability, such as James Webb Space Telescope and Wide Field Space Telescope, help achieve next generation science advancements. Composite materials often used for science applications include high modulus fibers in cyanate ester matrices to result in dimensionally stable structures with low contamination. Hand lay-up fabrication is the most common approach for science instrument structures. Automated Fiber Placement (AFP) using intermediate modulus fibers is commonplace in aircraft production reducing manufacturing time and increasing quality and consistency. AFP manufacturing for future large science instruments can similarly reduce costs and increase reliability. However, high modulus fibers are more prone to damage than intermediate modulus fibers. This study investigates the manufacturing viability of M55J/RS3C (Tencate) slit tape material using AFP processing. Tencate provides slit tape materials. NASA Langley Research Center (LaRC) manufactured hand layup and AFP lay-up laminates under room temperature for initial trials, Marshall Space Flight Center (MSFC) manufactured AFP laminates under room temperature and elevated temperature conditions to evaluate processing affects. Goddard Space Flight Center (GSFC) tests and evaluates tension and Coefficient of Thermal Expansion (CTE) properties by hand lay-up and AFP slit tape automated manufacturing for large science applications. These results show processing material warm reduces process induced fiber fracture; leading to stiffness and CTE properties consistent with hand lay-up, while observing a slight degradation in tensile strength.

Segal, Kenneth N.↗

Availability of previously lost data and metadata from the Apollo Lunar Surface Experiments Package (ALSEP)

Fourteen types of geophysical instruments deployed at the Apollo 12, 14, 15, 16, and 17 sites by the astronauts for long-term observation were collectively called the Apollo Lunar Surface Experiments Package (ALSEP). These instruments were active from the times of their deployment (November 1969–December 1972) to September 1977. At the conclusion of the experiments, the raw instrument data received from the Moon prior to March 1976 were left unarchived. Portions of the data processed by the principal investigators (PIs) of these experiments had been archived at the NASA Space Science Data Coordinated Archive (NSSDCA) in various formats. The unarchived data, residing then on open-reel magnetic tapes, became lost in the decades since, along with much of the metadata (the supporting documents for these data). We have recently recovered 440 of the previously lost tapes, containing raw ALSEP instrument data from April through June of 1975. Here we describe the data extracted from these tapes and summarize the data products generated for archiving at the NASA Planetary Data System (PDS) and NSSDCA, along with their historical narrative. In addition, we have reformatted many of the datasets delivered to NSSDCA by the PIs in the 1970s for archiving at the PDS. Finally, we have compiled an online searchable repository of ALSEP-related documents by optically scanning tens of thousands of pages of them kept at the Lunar and Planetary Institute in Texas.

S. Nagihara↗

(abstract) The 1994 Laboratory Calibration Of TIMS

This summary describes the spatial, spectral, and radiometric calibration of TIMS performed at the JPL Thermal Infrared Calibration Facility (TIRCAL) between May and August 1994. The 1994 calibration of TIMS was the first to make use of the new EXABYTE (8mm helical-scan tape) recording system. With the new recorder, the TIMS data tapes may be read directly on any computer system that has an EXABYTE tape drive. We analyzed the calibration data sets using image processing procedures written in IDL (Research Systems, Inc., Boulder, CO 80303).

TIMS↗

Mechanical Design and Configuration of Penetrations for the Europa Clipper Avionics Vault Structure

The main purpose of the Avionics Vault is to shield radiation sensitive electronics for the Europa Clipper Spacecraft. The vault is a box structure made out of aluminum panels. The panels are roughly 10 mm thick in order to shield the electronics from the orbital total ionizing radiation around Jupiter. The vault requires an electromagnetic interference (EMI) shielding effectiveness (SE) of at least 70 dB in order to mitigate EMI with the spacecraft radar receiver. Overall, the vault accommodates four main types of penetrations: receptacle connectors, pass-through cables, fluid lines, and vent holes. More than 150 cables penetrate the vault panels to connect to electronic boxes inside. Fluid pipes enter and exit the vault to transfer heat to the rest of the spacecraft. Vent holes provide a path for air to escape from the vault during launch. Several novel penetrations designs were created to meet EMI and radiation shielding requirements. Receptacle connectors interface to the vault panels using 1.3 mm thick Ta10W plates. Pass-through cables penetrate the vault using aluminum clamshells after being wrapped with Teflon cushion tape, Kapton tape, and copper tape. Vent hole penetrations consist of a copper mesh for EMI shielding and an aluminum radiation shield bracket to direct air out of the vault during launch. Fluid lines terminate at the vault wall using mechanical fittings that resemble a nut and bolt interface. In addition, most mechanical seams and penetrations utilize EMI gaskets to ensure proper EMI shielding. To reduce risk and confirm that the vault penetration designs were appropriate for EMI shielding, an EMI chamber at the Jet Propulsion Laboratory (JPL) was used to test a mock-up vault panel with multiple variations of all four main types of vault penetrations. This EMI SE test also incorporated different methods for bundling pass-through cables, and a comparison of flange mounted connectors versus jam nut connectors. A low noise preamplifier and a Rohde & Schwarz spectrum analyzer measured E-field levels transmitting through the mock-up vault panel. The results showed a shielding effectiveness of 77 dB for the mock-up vault panel, which exceeds the 70 dB target for Europa Clipper. Both the flange mounted connectors and jam nut connectors exhibited similar EMI SE results at the measured frequencies, and all variations of vault penetrations showed favorable EMI SE levels. Since the flight panels will be much larger and include many more penetrations, there will be testing of the flight vault to confirm its EMI SE is compliant with environmental requirements.

Giersch, Louis↗

Reel-to-reel exfoliation and processing of second generation superconductors

The substrate and buffer layers, of either one-sided or two-sided superconducting tape, are separated from the YCBO layer(s) of the tape by a combined action of radiative or inductive heat and mechanical force via a reel-to-reel manufacturing process. The exfoliation process may also utilize an air blade(s) to facilitate the separation of the layers of the tape.

Solovyov, Vyacheslav↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation and Mitigation of a Prominent Off-Axis Stray Light Path in Rubin Observatory Commissioning

The "scratched tape" stray light feature is the most prominent and prevalent stray light artifact identified during the commissioning of the Vera C. Rubin Observatory. The scratched tape feature originates when light from large off-axis angles (~20 deg) passes between the mid-level and center-section light baffles, reflects off the primary mirror, and illuminates the LSST Camera focal plane. This scenario represented an unobstructed stray light path to the sky during Rubin commissioning due to delays in the integration of the dome slit light-wind screen. This document describes the identification, modeling, characterization, and mitigation of the scratched tape stray light artifact.

Drlica-Wagner, Alex [Fermilab; Chicago U., Astron.↗

Executive routine

Utilization of history tape and tape library procedures of alternate executive routine for minivar computer program

MAGNETIC TAPE↗

(abstract) Unidirectional Carbon/Carbon for Ion Engine Optics

Conventional ion engine optical grids are made from hydroformed molybdenum. Carbon/carbon has been utilized in place of molybdenum because of its lower sputter yield, which contributes a greatly increased engine life, and for its low cte, which allows more efficient engine operation. The requirements for this material are that it must have high stiffness, very tight dimensional tolerances, and can be optimized for an hexagonal hole pattern with a very high open area friction. The carbon/carbon for this application was fabricated from unidirectional tape prepreg, using pitch fiber, and was processed to a very high temperature. The use of unidirectional tape allowed for a sufficient number of plies to be used to generate a balanced three directional layup within the thickness constraints of the material, as well as providing strength and stiffness over that normally seen with fabric based carbon/carbons.

ion engine carbon/carbon unidirectional tape prepr↗

High-efficiency single-junction p-i-n GaAs solar cell on roll-to-roll epi-ready flexible metal foils for low-cost photovoltaics

We demonstrate the fabrication and characterization of high-efficiency, single-junction p-i-n GaAs solar cells, on flexible metal foil with epi-ready buffer via roll-to-roll fabrication. Single-junction p-i-n GaAs solar cells were fabricated using metal–organic chemical vapor deposition (MOCVD). Furthermore, an efficiency greater than 13% was obtained at 1 sun, which is the highest reported efficiency on GaAs photovoltaics directly deposited on metal tapes. This exceeds our previously reported study showcasing 11.5% efficiency on single-junction p-n solar cell structure. Improved morphology of p-i-n structure compared with p-n is explained by atomic force microscopy (AFM), scanning electron microscopy (SEM), and helium ion microscopy (HIM) measurements. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) analysis showed reduced Zn diffusion in p-i-n cell compared with the p-n cell. We attribute the improvement in efficiency of p-i-n cells on flexible metal tapes to the quality of the junction, surface morphology, controlled diffusion of species within the active layers, and increase in absorption due to the optimized intrinsic layer thickness.

14 SOLAR ENERGY↗

Intramedullary Unicortical Button and All-Suture Anchors Provide Similar Maximum Strength for Onlay Distal Biceps Tendon Repair

To evaluate the biomechanical profile of onlay distal biceps repair with an intramedullary unicortical button versus all-suture anchors under cyclic loading and maximal load to failure. Twenty paired fresh-frozen human cadaveric elbows were randomized to onlay distal biceps repair with either a single intramedullary button or with two 1.35-mm all-suture anchors. A 1.3-mm high tensile strength tape was used in a Krackow stitch to suture the tendons in both groups. Specimens and repair constructs were loaded for 3,000 cycles and then loaded to failure. Maximum load to failure, mode of failure, and construct elongation were recorded. Mean (± standard deviation) maximum load to failure for the unicortical intramedullary button and all-suture anchor repairs were 503.23 ± 141.77 N and 537.33 ± 262.13 N (P = .696), respectively. Mean maximum displacement after 3,000 cycles (± standard deviation) was 4.17 ± 2.05 mm in the button group and 2.06 ± 1.05 mm in the suture anchor group (P = .014). Mode of failure in the button group was suture tape rupture in 7 specimens, failure at the tendon–suture interface in 2 specimens, and button pullout in 1 specimen. Anchor pullout was the mode of failure in all suture anchor specimens. There were no tendon ruptures or radial tuberosity fractures in either group. In conclusion, this study demonstrates that onlay distal biceps repair with 2 all-suture anchors has similar maximum strength to repair with an intramedullary button and that both are viable options for fixation.

60 APPLIED LIFE SCIENCES↗

Optimization of catholyte for halide-based all-solid-state batteries

Halide solid electrolytes gain significant attention due to their high ionic conductivity, low processing temperature, dry air compatibility, and high-voltage stability. However, low cathode active material (CAM) loading in the composite cathode constrains the realization of high energy density for halide-based all-solid-state batteries. In this study, three halide materials, raw Li 3 YBrCl 5 (LYBC-R, <30μm), milled LYBC (LYBC-M, <5 μm) and freeze-dried Li 3 InCl 6 (LIC, <500 nm), were used as catholytes, combined with LYBC-M as the electrolyte and LiIn alloy as the anode. The CAM:catholyte ratio was investigated as well as stack pressure and operating temperature. Our study demonstrates that particle size of the catholyte plays an important role only for high CAM loading or high C-rate cycling. At moderate CAM loading (65 and 70wt% LiNi 0.83 Mn 0.06 Co 0.11 O 2 ) and 0.1 C-rate, all the three catholytes perform well, providing initial discharge capacities >177 mAh/g. At high CAM loading (85wt%) and 0.1 C-rate, a cathode with the nano-scale LIC catholyte provides discharge capacity of 175 mAh/g, while the larger particle size catholytes suffer significantly reduced capacity. Both LYBC and LIC catholytes provided capacity retention >80% after 200 cycles at 0.5C. These results imply that cathode particle size is critically important for performance at high CAM loading. Furthermore, both electrolyte and cathode were tape cast to scale up size and prepare realistic layer thicknesses. A small amount of binder was used in both layers, to balance the electrochemical performance and mechanical properties. Further, the discharge capacity of a tape cell was 152mA h/g at 0.1C with a capacity retention of 81.8% after 20 cycles at 0.5C. The results demonstrate the excellent performance of LYBC as an electrolyte, and provide guidance for halide-based cathode design.

25 ENERGY STORAGE↗

Measurements of scattering and absorption properties of submillimeter bauxite and silica particles

Submillimeter solid particles have been considered as thermal storage media for concentrated solar power applications. Knowledge of the scattering and absorption properties of individual particles is crucial for modeling the radiative heat transfer of the particle bed. In this work, a laser scatterometer is used to measure the single-particle scattering properties at a wavelength of 635 nm by using two configurations: (1) a falling particle curtain and (2) a taped particle layer. Because a one-particle nominal thickness is formed with area fractions of 5-55% depending on the configuration, multiple scattering is minimized and hence the single scattering phase function, averaged over all illuminated particles, is directly measured. Bauxite-based ceramic particles that are strongly absorbing in the solar spectrum and silica particles that are nonabsorbing in the visible and near-infrared are investigated. The directional-hemispherical reflectance and transmittance of the taped particles are also measured to deduce the forward and backward scattering efficiency factors and the absorption efficiency factors. Only weak wavelength dependence is observed in the measured region from 380 nm to 1020 nm. Furthermore, the scattering phase functions of all bauxite-based particles with varying sizes and compositions are very similar and can be fitted to a Henyey-Greenstein phase function with an asymmetry factor g = -0.20. For the silica particles, forward scattering dominates and g = 0.45 yields the best fit. A Monte Carlo method is developed to model the particle scattering characteristics, and reasonable agreements between the modeling and experimental results are observed by introducing a specularity parameter.

42 ENGINEERING↗

Root cause analysis of a molten salt pump in FLUSTFA

The primary salt pump installed in the high-temperature FLUoride Salt Test Facility (FLUSTFA) was successfully operated for some time, but later ceased operation. To understand what occurred, a Root Cause Analysis (RCA) was performed. Steps taken to try to get the pump operational include adjusting the shaft position, increasing the heating power of the tape heaters on the pump volute, and manually rotating the pump shaft. While removing the insulation, corrosion was noted on the outside of the pump volute, and decolorization of the insulation and tape heaters was observed. Significant corrosion products were also observed in the pump itself and the piping connected to the pump. The nitrogen cover gas was maintained from before salt was introduced into the loop until the pump was dismounted and continues to be maintained even after the pump was removed. After considering probable scenarios, causes were assigned and corrective actions were developed to prevent those causes. Then, the RCA was presented to an advisory committee for review, the “Review Committee,” consisting of experts in large molten salt systems: Brandon Haugh, David Holcomb, Kevin Robb, and Vicente Rojas. As a result, the advisory committee provided comprehensive feedback, which have been incorporated into a revised RCA. Findings have then been summarized and reported in this publication.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗