Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Active and Passive Radiative Transfer Simulations for GPM-Related Field Campaigns

Radiative transfer modeling is an important tool for interpreting remote sensing observations. It allows us to determine how sensor characteristics will impact observations, and it gives us a framework for us to test assumptions about the phenomena we are attempting to observe. In this work, we use cloud simulations for precipitation events observed during various GPM-related field campaigns. The simulations show how various properties of clouds and precipitation affect the measurements.

Adams, Ian S.↗

Coherent radiation by a spherical medium of resonant atoms

Radiation by the atoms of a resonant medium is a cooperative process in which the medium participates as a whole. In two previous papers we treated this problem for the case of a medium having slab geometry, which, under plane-wave excitation, supports coherent waves that propagate in one dimension. We extend the treatment here to the three-dimensional problem, focusing principally on the case of spherical geometry. By regarding the radiation field as a superposition of electric and magnetic multipole fields of different orders, we express it in terms of suitably defined scalar fields. The latter fields possess a sequence of exponentially decaying eigenmodes corresponding to each multipole order. We consider several examples of spherically symmetric initial excitations of a sphere. Small uniformly excited spheres, we find, tend to radiate superradiantly, while the radiation from a large sphere with an initially excited inner core exhibits temporal oscillations that result from the participation of a large number of coherently excited amplitudes in different modes. The frequency spectrum of the emitted radiation possesses a rich structure, including a frequency gap for large spheres and sharply defined and closely spaced peaks caused by the small frequency shifts and even smaller decay rates characteristic of the majority of eigenmodes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of the Cherenkov Telescope Array to the detection of axion-like particles at high gamma-ray opacities

Extensions of the Standard Model of particles commonly predict the existence of axion(-like) particles (ALPs) that could be detected through their coupling to photons in external magnetic fields. This coupling could lead to modifications of γ-ray spectra from extragalactic sources. Above a certain energy, the γ-ray flux should be exponentially damped due to the interaction with photons of background radiations fields. ALPs, on the other hand, propagate unimpeded over cosmological distances and a reconversion into γ-rays could lead to an additional component in the spectra. Here, we present the sensitivity of the proposed Cherenkov Telescope Array (CTA) to detect this spectral hardening. Using the full instrumental response functions of CTA, a combined likelihood analysis of four γ-ray sources shows that a significant detection of the ALP signal is possible for couplings g{sub aγ} ≳ 2 × 10{sup −11} GeV{sup −1} and ALP masses m{sub a} ∼< 100 neV. We discuss the dependency of these values on different model assumptions and magnetic-field scenarios and identify the best observation strategy to search for an ALP induced boost of the γ-ray flux.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-BRE-09: Towards the Establishment of Dosimetric References in Small Fields Using the New Concept of Dose-Area Product

Purpose: To establish dosimetric references of absorbed dose in water in radiation fields smaller than 2 cm used in radiotherapy thanks to a new methodology based on the use of dosimeters larger than the field size. Methods: A new graphite calorimeter was constructed with a large sensitive volume (diameter of the core: 30 mm). This primary dosimeter was fully characterized and compared to previous LNE-LNHB graphite calorimeters in a 60Co large field. A specially designed graphite parallel-plate ionization chamber with a 30 mm collecting electrode was also assembled and tested. Measurements were then conducted in two 6 MV small circular fields of 2 cm and 1 cm diameter respectively, using the new concept of dose-area product instead of punctual dose commonly used in radiotherapy. Results: The dose rate established in a large 60Co field with the new calorimeter is in agreement within 0.4% with previous calorimeters. The ionization chamber shows good characteristics except for a 0.06% drift per hour in water. The ratio of calorimetric against ionometric measurements in the 2 cm diameter field is 1.1% higher than the one in the 1 cm diameter field (with respectively 0.30% and 1.03% type A uncertainty for each field). Conclusion: Results presented here highlight the possibility of measuring dose-area products in small fields with a graphite calorimeter and a parallel-plate ionization chamber. Measurements in a 0.75 cm diameter field are already underway to confirm the trend observed in the 2 cm and 1 cm diameter fields. The last step to establish precise dosimetric references in small fields is to calculate correction factors thanks to Monte Carlo simulations.

07 ISOTOPE AND RADIATION SOURCES↗

A multi-dimensional, moment-accelerated deterministic particle method for time-dependent, multi-frequency thermal radiative transfer problems

Thermal Radiative Transfer (TRT) is the dominant energy transfer mechanism in high-energy density physics with applications in inertial confinement fusion and astrophysics. The stiff interactions between the material and radiation fields make TRT problems challenging to model. In this study, we propose a multi-dimensional extension of the deterministic particle (DP) method. The DP method combines aspects from both particle and deterministic methods. If the emission source is known a priori, and no physical scattering is present, the intensity of a particle can be integrated analytically. This introduces no statistical noise compared to Monte-Carlo methods, while maintaining the flexibility of particle methods. The method is closely related to the popular method of long characteristics. The combination of the DP-method with a discretely-consistent, nonlinear, gray low-order system enables an efficient solution algorithm for multi-frequency TRT problems. Here, we demonstrate with numerical examples that the use of a linear-source approximation based on spatial moments improves the behavior of our method in the thick diffusion limit significantly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fundamentals of Radiation Dosimetry

The basic concepts of radiation dosimetry are reviewed on basis of ICRU reports and text books. The radiation field is described with, among others, the particle fluence. Cross sections for indirectly ionizing radiation are defined and indicated is how they are related to the mass energy transfer and mass energy absorption coefficients. Definitions of total and restricted mass stopping powers of directly ionizing radiation are given. The dosimetric quantities, kerma, absorbed dose and exposure together with the relations between them are discussed in depth. Finally it is indicated how the absorbed dose can be measured with a calorimeter by measuring the temperature increase and with an ionisation chamber measuring the charge produced by the ionizing radiation and making use of the Bragg-Gray relation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Elementary processes of stimulated emission

We consider the simplest process of stimulated emission, i.e., evolution of an excited two-level atom interacting with a quantized electromagnetic field being initially in a one-photon state under different boundary conditions imposed on the field. We study the kinetics of evolution, spectral properties and modal composition of the radiation field emerging in such processes. It is shown that in the general case this field is only partly composed of doubly occupied modes.

74 ATOMIC AND MOLECULAR PHYSICS↗

General description of electromagnetic radiation processes based on instantaneous charge acceleration in ''endpoints''

We present a methodology for calculating the electromagnetic radiation from accelerated charged particles. Our formulation - the 'endpoint formulation' - combines numerous results developed in the literature in relation to radiation arising from particle acceleration using a complete, and completely general, treatment. We do this by describing particle motion via a series of discrete, instantaneous acceleration events, or 'endpoints', with each such event being treated as a source of emission. This method implicitly allows for particle creation and destruction, and is suited to direct numerical implementation in either the time or frequency domains. In this paper we demonstrate the complete generality of our method for calculating the radiated field from charged particle acceleration, and show how it reduces to the classical named radiation processes such as synchrotron, Tamm's description of Vavilov-Cherenkov, and transition radiation under appropriate limits. Using this formulation, we are immediately able to answer outstanding questions regarding the phenomenology of radio emission from ultra-high-energy particle interactions in both the earth's atmosphere and the moon. In particular, our formulation makes it apparent that the dominant emission component of the Askaryan effect (coherent radio-wave radiation from high-energy particle cascades in dense media) comes from coherent 'bremsstrahlung' from particle acceleration, rather than coherent Vavilov-Cherenkov radiation.

43 PARTICLE ACCELERATORS↗

An MLC calibration method using a detector array

Purpose: The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. Methods: The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Corporation, Melbourne, FL). To calibrate the MLC bank, its backup jaw is positioned at the central axis and the opposing jaw is retracted to create a half-beam configuration. The position of the backup jaws field edge is then measured with the array to obtain what is termed the radiation defined reference line. The positions of the individual leaf ends relative to this reference line are then inferred by the detector response in the leaf end penumbra. Iteratively adjusting and remeasuring the leaf end positions to within specifications completes the calibration. Using the backup jaw as a reference for the leaf end positions is based on three assumptions: (1) The leading edge of an MLC leaf bank is parallel to its backup jaw's leading edge, (2) the backup jaw position is reproducible, and (3) the measured radiation field edge created by each leaf end is representative of that leaf's position. Data from an electronic portal imaging device (EPID) were used in a similar analysis to check the results obtained with the array. Results: The relative leaf end positions measured with the array differed from those measured with the EPID by an average of 0.11 {+-}0.09 mm per leaf. The maximum leaf positional change measured with the Profiler 2 over a 3 month period was 0.51 mm. A leaf positional accuracy of {+-}0.4 mm is easily attainable through the iterative calibration process. The method requires an average of 40 min to measure both leaf banks. Conclusions: This work demonstrates that the Profiler 2 is an effective tool for efficient and quantitative MLC quality assurance and calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel High Efficiency 1.5 MW, 110 GHz Gyrotron with HE11 Output for Plasma Heating

We applied a recently developed mode converter synthesis method (D. Sobolev and G. Denisov, “Principles of Synthesis of Multimode Waveguide Units”, IEEE Trans. Plasma Sci., Vol. 38, No. 10, Oct. 2010) to the design of a quasi-optical (QO) launcher for high power gyrotrons. This technique, based on the reciprocity theorem, provides a highly efficient iterative process. The initial design results of a QO launcher obtained using the Launcher Optimization Tool (LOT) were used as input to the new launcher surface synthesis algorithm. The target radiation field was defined as a Gaussian beam with best fit waist size to beam radiated from LOT optimized surface. A significant improvement in the quality of launcher output beam was obtained and the Gaussian output content was calculated at 98%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compton scatter attenuation gamma ray spectrometer

A gamma ray spectrometer is described for use in intense radiation fields such as those in the vicinity of a rocket engine exhaust. A collimated radiation beam is Compton scattered toward shielded spectrometers to reduce the energy and intensity of the radiation and is energy selective among the spectrometers. The scattering targets are changeable to control the percentage of the radiation scattered. Sum-Compton coincidence techniques are employed for data selection.

Austin, W. E.↗

Orbital and cloud cover sampling analyses for multisatellite earth radiation budget experiments

Computer simulations have been performed to determine the geographical and temporal coverage of various satellite orbits and scanning and nonscanning radiometers for earth radiation budget measurements. These results were used to simulate the sampling of a diurnally varying cloud and radiation field for several different satellite systems to estimate errors in regional monthly mean reflected radiation. The combined results indicate that coincient observations with a minimum of one sun-synchronous satellite and a midinclined orbit satellite are needed to obtain the required regional, zonal, and global coverage with sufficient temporal sampling for obtaining accurate estimates of monthly mean reflected solar radiation. Overall, the best sampling capability and lowest errors were obtained with a three-satellite system, i.e., two sun-synchronous satellites with different equatorial crossing times combined with either a 46 or 57-deg orbit satellite. The results from these analyses have been used in defining a joint NASA-NOAA multisatellite mission for an earth radiation budget experiment.

Harrison, E. F.↗

Radiation transport in dust in disk geometry

The main objective of the research program is twofold: (1) to develop a computer code to solve the problem of scattering, absorption and emission of photons by dust grains in a dusty medium with 2 dimensional disk geometry, and (2) to study the various physical and geometrical effects of 2 dimensional radiation transport on the thermal structure and radiation field. These tasks were accomplished and are briefly summarized. The method for solving the radiation transport problem in disk geometry is a generalization of the quasi-diffusion method (QDM) previously developed by the author.

Chun, Ming Leung↗

Sound radiation from an airfoil encountering an oblique gust in its plane of motion

An evaluation is conducted of the acoustic field radiated when an airfoil encounters a gust in the plane of motion, with a view to the prediction of helicopter tail rotor noise. The analysis is based on the unsteady thickness noise theory of Glegg (1987). Sound radiation is shown to be dominated by the transient effect of the blade tip moving into the velocity deficit, so that the effects of blade rotation are not important.

Glegg, Stewart A. L.↗

TEPC Response Functions

The tissue equivalent proportional counter had the purpose of providing the energy absorbed from a radiation field and an estimate of the corresponding linear energy transfer (LET) for evaluation of radiation quality to convert to dose equivalent. It was the recognition of the limitations in estimating LET which lead to a new approach to dosimetry, microdosimetry, and the corresponding emphasis on energy deposit in a small tissue volume as the driver of biological response with the defined quantity of lineal energy. In many circumstances, the average of the lineal energy and LET are closely related and has provided a basis for estimating dose equivalent. Still in many cases the lineal is poorly related to LET and brings into question the usefulness as a general purpose device. These relationships are examined in this paper.

Shinn, J. L.↗

Statistical Projection of Solar Cycle 24 for the Exposure Estimates

A solar cycle statistical model has been developed based on the accumulating cycle sunspot data to estimate future levels of the solar cycle activity. Since the current solar cycle 24 has progressed about three years, the cycle activity levels are estimated with an accurately defined solar minimum 24. Then, solar cycle 24 is projected with the cycle activity levels using the statistical model. The projection of solar cycle 24 is then coupled to space related quantities of interest to radiation protection, because the interplanetary plasma and radiation fields are modulated by the degree of disturbance in the solar surface and the radiation doses received by astronauts in interplanetary space are likewise influenced. The resultant projection of solar cycle 24 provides a basis for estimating exposure in future space missions, and projection errors can be corrected as the cycle progresses and observations become available because this model is shown to be self-correcting.

Kim, Myung-Hee↗

Particle production by time-varying dark energy and the end of cosmic expansion

We consider various possible consequences of time-varying dark energy due to a quintessence scalar field whose energy density is partially converted to particles as the field evolves down its potential. This particle production acts as a source of thermal friction on the field that can make it difficult to distinguish whether dark energy is due to a radiating field rolling down a steep potential, a purely self-interacting field moving down a flatter potential, or a cosmological constant. By reducing the acceleration of the scalar field, thermal friction increases the amount of accelerated expansion and can cause a sizable bump in the quintessence equation of state. We take special interest in the case where a steep potential rapidly changes from positive to negative as the field evolves, resulting in the end of cosmic expansion and the beginning of contraction. Even in this case, we find that thermal friction lengthens the period of accelerated expansion and consequently delays the end of cosmic expansion, making it challenging to detect the impending transition to contraction using conventional cosmological tests. However, particle production can also provide alternative avenues for detection by generating a background of thermal dark radiation, partly comprised of neutrinos or other particles, whose energy density exceeds the remnant photon energy density.

cosmological neutrinos↗