Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Precise Fabrication of Silicon Wafers Using Gas Cluster Ion Beams

Precise surface processing of a silicon wafer was studied by using a gas cluster ion beam (GCIB). The damage caused to the silicon surface was strongly dependent on irradiation parameters. The extent of damage varied with the species of source gas and the acceleration voltage (Va) of cluster ions. It also varied with the cluster size and residual gas pressure. The influence of electron acceleration voltage (Ve) used for ionization of a neutral cluster was also investigated. The irradiation damage, such as an amorphous silicon (a-Si) layer, a mixed layer of a-Si and c-Si (transition layer), and surface roughness, was increased with Ve. It is suggested that the increase in the amount of energy per atom was induced by high Ve, because of variation of the cluster size and/or cluster charge. An undamaged smooth surface can be produced by Ar-GCIB irradiation at low Ve and Va.

36 MATERIALS SCIENCE↗

High precision Standard Model Physics

The main goal of the LHCb experiment, one of the four large experiments of the Large Hadron Collider, is to try to give answers to the question of why Nature prefers matter over antimatter? This will be done by studying the decay of b quarks and their antimatter partners, b-bar, which will be produced by billions in 14 TeV p-p collisions by the LHC. In addition, as 'beauty' particles mainly decay in charm particles, an interesting program of charm physics will be carried on, allowing to measure quantities as for instance the D{sup 0}-D-bar{sup 0} mixing, with incredible precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Precision Noise Measurements at Microwave Frequencies

We describe microwave noise measurement system capable of detecting the phase fluctuations of rms amplitude of 2{center_dot}10{sup -11} rad/{radical}(Hz). Such resolution allows the study of intrinsic fluctuations in various microwave components and materials, as well as precise tests of fundamental physics. Employing this system we discovered a previously unknown phenomenon of down-conversion of pump oscillator phase noise into the low-frequency voltage fluctuations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision hyperfine structure spectroscopy of Be isotopes at SLOWRI prototype and prospects of SLOWRI at RIKEN

Precision atomic spectroscopy experiments for Be isotopes have been carried out at the prototype universal slow RI-beam (SLOWRI) setup at RIKEN. Radioactive Be ions produced at 1 GeV were decelerated and thermlized in an RF-carpet ion guide. The thermalized ions were transferred to an ion trap where laser cooling was used to reduce the ion energy to the order of 1 {mu}eV. Laser microwave double resonance spectroscopy was performed for the hyperfine structure measurements of trapped and laser cooled {sup 7}Be{sup +} and {sup 11}Be{sup +} ions. Measurements of the S{sub 1/2}{yields}P{sub 1/2},P{sub 3/2} transition frequencies of {sup 7,9,10,11}Be{sup +} ions are also in progress. These results are briefly discussed. Future prospects for expanding the capability of SLOWRI is also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

New technology enables high precision multislit collimators for microbeam radiation therapy

During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 {mu}m full width at half maximum (FWHM) values and 100-400 {mu}m center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 {mu}m FWHM and 400 {mu}m c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 {mu}m to less than 1 {mu}m for a nominal FWHM value of 25 {mu}m. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Quark-Gluon Correlations in the Neutron: Precision Measurements of d{sub 2}{sup n} and g{sub 2}{sup n}

We discuss two Jefferson Lab measurements of the spin structure function g{sub 2} and the higher twist reduced matrix element d{sub 2} on the neutron. The first, E06-014, just completed its run in March 2009 and will reduce the uncertainty on the neutron d{sub 2} by a projected factor of four. The second experiment to be described, E12-06-121, is targeted to run shortly after the JLab 12 GeV upgrade is completed (est. 2014-5) and will focus on precision measurements of g{sub 2}{sup n} over the region 0.2<x<0.95 and 2.5<Q{sup 2}<6 GeV{sup 2}/c{sup 2}. The latter experiment will also provide the first explicit measurement of the Q{sup 2} evolution of d{sub 2}{sup n} for Q{sup 2}>1 GeV{sup 2}/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Polarimetry of Solid HD Photonuclear Targets at LEGS

We have constructed and operated a NMR polarimeter for high-accuracy measurements of hydrogen and deuterium polarization in a frozen-spin solid HD photonuclear physics target. The heart of this polarimeter is a pair of crossed (orthogonal) RF coils that form a transformer that responds only to precessing spins in the sample. We have performed a complete electronic circuit analysis of this crossed coil polarimeter (CC-Meter), and have determined the optimum conditions for its operation. From this analysis, which is confirmed by NMR measurements on hydrogen and deuterium in solid HD, we conclude that the CC-meter can be operated to give a very high signal-to-noise ratio (SNR) for thermal equilibrium polarization while also producing a highly linear response for fully polarized targets. In general, we find that a well-designed and properly constructed CC-Meter can provide a larger SNR at similar nonlinearity, compared to the more commonly used Q-meter. We have used this polarimeter to produce H polarization measurements for a new, high precision determination of the GDH integral for the proton.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Spectroscopy of Hydrogen with a Lamb-Shift Polarimeter

A spinfilter, the most important component of a Lamb-shift polarimeter, is used to produce a beam of metastable hydrogen (deuterium) atoms in one hyperfine state (HFS)(alpha1, alpha2 and together with the Sona transition beta3). As function of a magnetic field separated transitions between the 2s{sub 1/2} metastable Zeeman states seem to be observable as well as single transitions into the short-lived 2P{sub 1/2} and 2P{sub 3/2} states. The Breit-Rabi diagrams for these states and, therefore, the g factors can be measured with good precision. Furthermore, the hyperfine splittings and the Lamb shift can be observed as well. Application of this method to anti-hydrogen atoms is suggested.

74 ATOMIC AND MOLECULAR PHYSICS↗

Detection of Stellar Pulsations in the Planet Host Star {gamma} Cephei A by High Precision Radial Velocity Measurements

We present a first analysis of our asteroseismology campaign on the planet host star {gamma} Cep A. We used seven consecutive nights at the Harlan J. Smith 2.7 m telescope at McDonald Observatory to obtain 1200 highly precise radial velocity measurements. We find the star to be a multi-periodic pulsator with a frequency spacing of 15 {mu}Hz.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Spin Structure Functions for the Proton and Deuteron with CLAS

An extensive experimental program to measure the spin structure of the nucleon has been carried out in in Hall B at Jefferson Lab with the CEBAF Large Acceptance Spectrometer (CLAS). Using a longitudinally polarized beam scattering off longitudinally polarized NH{sub 3} and ND{sub 3} targets, the double spin asymmetry A{sub parallel} was measured over a large range in Q{sup 2} and W, providing data of impressive high precision that will give a better understanding of the structure of the nucleon in the Deep Inelastic Scattering and the valence quarks regions. Using a world data parameterization of A{sub 2} and F{sub 1}, the virtual photon asymmetry A{sub 1} and the structure function g{sub 1} were extracted in a Q{sup 2} range from 0.05 to 5 GeV{sup 2} and a W range from 1.08 to 3.0 GeV. As a result of the extended kinematical range, first moments of structure functions were measured over a large range in Q{sup 2} and duality was tested. Finally, using the large kinematical overlap of different beam energies, A{sub 2} was extracted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A precise new KLOE measurement of |F{sub {pi}}|{sup 2} with ISR events and determination of {pi}{pi} contribution to a{sub {mu}} for 0.592<M{sub {pi}}{sub {pi}}<0.975 GeV

The KLOE experiment at the DA{phi}NE {phi}-factory has performed a new precise measurement of the pion form factor using Initial State Radiation events, with photons emitted at small polar angle. Results based on an integrated luminosity of 240 pb{sup -1} and extraction of the {pi}{pi} contribution to a{sub {mu}} in the mass range 0.35<M{sub {pi}}{sub {pi}}{sup 2}<0.95 GeV{sup 2} are presented. The new value of a{sub {mu}}{sup {pi}}{sup {pi}} has smaller (30%) statistical and systematic error and is consistent with the KLOE published value (confirming the current disagreement between the standard model prediction for a{sub {mu}} and the measured value)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PEN experiment: a precise measurement of the {pi}{sup +}{yields}e{sup +}{nu} decay branching fraction

A new measurement of B{sub {pi}}{sub e2}, the {pi}{sup +}{yields}e{sup +}{nu}({gamma}) decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on B{sub {pi}}{sub e2} constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Because of the large helicity suppression of the {pi}{sub e2} decay, its branching ratio is susceptible to significant contributions from new physics, making this decay a particularly suitable subject of study.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision thermal stress study on flip chips by synchrotron polychromatic x-ray microdiffraction

The bending and residual stress of flip chips caused by the mismatch of thermal expansion between the chip and the substrate have been measured by polychromatic microfocused synchrotron x-ray beam. Precise orientation information as a function of position on the chip was obtained from Laue diffraction patterns, so that the bending angle with respect to a reference position at the center of the chip can be calculated at each position. This in turn allows deducing the local curvature of the entire flip chip. Local stress distribution was then mapped by applying a modified Stoney's stress-strain equation to the measured curvature. Our study shows that thermal stress on the circuits and the solder joints in a flip chip strongly depend on temperature and the distance from the center of the chip, indicating that interconnects at the corner and edge of a flip chip are of reliability concerns.

36 MATERIALS SCIENCE↗

A technique for extending the precision and the range of temperature programmed desorption toward extremely low coverages

In this paper, an improvement of the temperature programmed desorption (TPD) technique is introduced, which facilitates fully automated sampling of TPD spectra with excellent reproducibility, especially useful for extremely low coverages. By averaging many sampled TPD spectra, the range of the TPD technique can be extended toward lower coverages, as well as the quality of the spectra can be improved. This allows for easy extraction of information about the adsorbate-surface bond. A state of the art TPD apparatus with a two chamber setup and a high quality quadrupole mass spectrometer was extended by automated components. These are an automated gas dosing system, ensuring precise dosing of gas, combined with a motor driven sample manipulation unit and a liquid nitrogen cryostat with automatic refilling. In addition all components were controlled by a computer. A large number of TPD cycles could be sampled without the need of interaction of an operator. Here, it is shown for up to more than 400 TPD cycles. This opens a wide range of new interesting applications for the TPD technique, especially in the limit of zero coverage. Here, basic experiments on well known adsorbate systems are shown to view the ability and limit of this approach.

36 MATERIALS SCIENCE↗

High-precision measurements of the equation of state of hydrocarbons at 1-10 Mbar using laser-driven shock waves

The equation of state (EOS) of polystyrene and polypropylene were measured using laser-driven shock waves with pressures from 1 to 10 Mbar. Precision data resulting from the use of alpha-quartz as an impedance-matching (IM) standard tightly constrains the EOS of these hydrocarbons, even with the inclusion of systematic errors inherent to IM. The temperature at these high pressures was measured, which, combined with kinematic measurements, provide a complete shock EOS. Both hydrocarbons were observed to reach similar compressions and temperatures as a function of pressure. The materials were observed to transition from transparent insulators to reflecting conductors at pressures of 1 to 2 Mbar.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An experimental procedure for precise evaluation of electron density distribution of a nanostructured material by coherent x-ray diffraction microscopy

We developed a coherent x-ray diffraction microscopy (CXDM) system that enables us to precisely evaluate the electron density of an isolated sample. This system enables us to determine the dose per surface unit of x rays illuminated onto an isolated sample by combining incident x-ray intensity monitoring and the CXDM of a reference sample. By using this system, we determined the dose of x rays illuminated onto a nanostructured island fabricated by focused-ion-beam chemical vapor deposition and derived the electron density distribution of such a nanostructured island. A projection image of the nanostructured island with a spatial resolution of 24.1 nm and a contrast resolution higher than 2.3x10{sup 7} electrons/pixel was successfully reconstructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithm for precision subsample timing between Gaussian-like pulses

Moderately priced oscilloscopes available for the NIF power sensors and target diagnostics have 6 GHz bandwidths at 20-25 Gsamples/s (40 ps sample spacing). Some NIF experiments require cross timing between instruments be determined with accuracy better than 30 ps. A simple analysis algorithm for Gaussian-like pulses such as the 100-ps-wide NIF timing fiducial can achieve single-event cross-timing precision of 1 ps (1/50 of the sample spacing). The midpoint-timing algorithm is presented along with simulations that show why the technique produces good timing results. Optimum pulse width is found to be {approx}2.5 times the sample spacing. Experimental measurements demonstrate use of the technique and highlight the conditions needed to obtain optimum timing performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗