DOE OSTI · 22055849
Algorithm for precision subsample timing between Gaussian-like pulses
Abstract
Moderately priced oscilloscopes available for the NIF power sensors and target diagnostics have 6 GHz bandwidths at 20-25 Gsamples/s (40 ps sample spacing). Some NIF experiments require cross timing between instruments be determined with accuracy better than 30 ps. A simple analysis algorithm for Gaussian-like pulses such as the 100-ps-wide NIF timing fiducial can achieve single-event cross-timing precision of 1 ps (1/50 of the sample spacing). The midpoint-timing algorithm is presented along with simulations that show why the technique produces good timing results. Optimum pulse width is found to be {approx}2.5 times the sample spacing. Experimental measurements demonstrate use of the technique and highlight the conditions needed to obtain optimum timing performance.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Lerche, R A, Golick, B P, Holder, J P, Kalantar, D H. 2010-10-15. Algorithm for precision subsample timing between Gaussian-like pulses. https://doi.org/10.1063/1.3475785