Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Simulated Mass Change Recovery for Various Implementations of A Future Atomic Interferometer Gravity Gradiometer (AIGG)

We present the status of the atomic interferometer gravity gradiometer (AIGG) instrument in development at NASA GSFC, along with the simulated science performance for a variety of potential implementation scenarios. These trade studies include assessing mission performance for varying levels of AIGG instrument sensitivity, different orientations of the single-axis AIGG, and different satellite altitudes. Additionally, we quantify performance for both single-platform AIGG-only and combined satellite-to-satellite (SST) and AIGG observing systems. An important part of this work is the determination of the AIGG instrument sensitivity threshold required to enhance the mass change measurements beyond the SST-only performance. The simulated AIGG science performance is compared to various single and dual-pair Bender constellations and the Science and Applications Traceability Matrix that resulted from NASA’s Mass Change Designated Observable study.

Bryant Daniel Loomis↗

The National Airborne Sounder Testbed-Interferometer (NAST-I): Pathfinder for Satellite Capabilities and Airborne Science

The National Airborne Sounder Testbed-Interferometer (NAST-I) is an existing ultraspectral infrared sounder flown on high-altitude aircraft that provides high spectral and spatial resolution measurements which continue to advance understanding of science critical for weather, climate, chemistry, and radiation applications. NAST-I provides high-spatial linear resolution equal to 13% of the aircraft altitude at nadir (i.e., 2.6 km IFOV on the ground from an aircraft altitude of 20 km), and high-spectral resolution (0.25 cm -1 ) measurements within the spectral region of 645–2700 cm -1 . The NAST-I suborbital system serves as a spaceborne instrument simulator and pathfinder for future satellite capabilities and airborne science experiments. Here we present some groundbreaking capabilities of NAST-I measurements and corresponding geophysical retrievals and their potential benefits toward improved atmospheric state and composition characterizations needed for air quality, wildfire, and other science applications.

NAST-I↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O2was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M Weisberger↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O 2 was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M. Weisberger↗

The National Airborne Sounder Testbed-Interferometer (Nast-I): Existing Technology for New Science and Application

The National Airborne Sounder Testbed-Interferometer (NAST-I) is an existing ultraspectral infrared sounder flown on high-altitude aircraft that provides high spectral and spatial resolution measurements which continue to advance understanding of science critical for weather, climate, chemistry, and radiation applications. NAST-I provides high-spatial linear resolution equal to 13% of the aircraft altitude at nadir (i.e., 2.6 km IFOV on the ground from an aircraft altitude of 20 km), and high-spectral resolution (0.25 cm-1) measurements within the spectral region of 645–2700 cm-1. The NAST-I suborbital system serves as a spaceborne instrument simulator and pathfinder for future satellite capabilities and airborne science experiments. Present herein are some groundbreaking capabilities of NAST-I measurements and corresponding geophysical retrievals and their potential benefits toward improved atmospheric state and composition characterizations needed for air quality, wildfire, and other science applications and, in particular, for enhanced Planetary Boundary Layer (PBL) characterization and understanding.

Remote sensor↗

Large Interferometer For Exoplanets (LIFE) XIII. The value of Combining Thermal Emission and Reflected Light for the Characterization of Earth Twins

Context. Following the recommendations to NASA (in the Astro2020 Decadal survey) and ESA (through the Voyage2050 process), the search for life on exoplanets will be a priority in the next decades. Two concepts for direct imaging space missions are being developed for this purpose: the Habitable Worlds Observatory (HWO) and the Large Interferometer for Exoplanets (LIFE). These two concepts operate in different spectral regimes: HWO is focused on reflected light spectra in the ultraviolet, visible, and near-infrared (UV/VIS/NIR), while LIFE will operate in the mid-infrared (MIR) to capture the thermal emission of temperate exoplanets. Aims. In this study, we aim to assess the potential of HWO and LIFE to characterize a cloud-free Earth twin orbiting a Sun-like star at a distance of 10 pc, both as separate missions and in synergy with each other. We aim to quantify the increase in information that can be gathered by joint atmospheric retrievals on a habitable planet. Methods. We performed Bayesian retrievals on simulated data obtained by an HWO-like mission and a LIFE-like one separately, then jointly. We considered the baseline spectral resolutions currently assumed for these concepts and used two increasingly complex noise simulations, obtained using state-of-the-art noise simulators. Results. An HWO-like concept would allow one to strongly constrain H 2 O, O 2 , and O 3 in the atmosphere of a cloud-free Earth twin, while the atmospheric temperature profile is not well constrained (with an average uncertainty ≈100 K). LIFE-like observations would strongly constrain CO 2 , H 2 O, and O 3 and provide stronger constraints on the thermal atmospheric structure and surface temperature (down to ≈10 K uncertainty). For all the investigated scenarios, both missions would provide an upper limit on CH 4 . A joint retrieval on HWO and LIFE data would accurately define the atmospheric thermal profile and planetary parameters. It would decisively constrain CO 2 , H 2 O, O 2 , and O 3 and find weak constraints on CO and CH 4 . The significance of the detection is in all cases greater than or equal to the single-instrument retrievals. Conclusions. Both missions provide specific information that is relevant for the characterization of a terrestrial habitable exoplanet, but the scientific yield can be maximized by considering synergistic studies of UV/VIS/NIR+MIR observations. The use of HWO and LIFE together will provide stronger constraints on biosignatures and life indicators, with the potential to be transformative for the search for life in the Universe.

E Alei↗

High data-rate atom interferometers through high recapture efficiency

An inertial sensing system includes a magneto-optical trap (MOT) that traps atoms within a specified trapping region. The system also includes a cooling laser that cools the trapped atoms so that the atoms remain within the specified region for a specified amount of time. The system further includes a light-pulse atom interferometer (LPAI) that performs an interferometric interrogation of the atoms to determine phase changes in the atoms. The system includes a controller that controls the timing of MOT and cooling laser operations, and controls the timing of interferometric operations to substantially recapture the atoms in the specified trapping region. The system includes a processor that determines the amount inertial movement of the inertial sensing system based on the determined phase changes in the atoms. Also, a method of inertial sensing using this inertial sensing system includes recapture of atoms within the MOT following interferometric interrogation by the LPAI.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nonlinear interferometer systems and methods

Nonlinear interferometers include a nonlinear optical medium that is situated to produce a conjugate optical beam in response to a pump beam and a probe beam. The pump, probe, and conjugate beams propagate displaced from each other along a common optical path. One of the beams is selectively phase shifted, and the beams are then returned to the nonlinear medium, with the selectively phase shift beam phase shifted again. The nonlinear medium provides phase sensitive gain to at least one of the probe or conjugate beams, and the amplified beam is detected to provide an estimate of the phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

42 ENGINEERING↗

Truncated nonlinear interferometer-based atomic force microscopes

A truncated non-linear interferometer-based atomic force microscope (AFM) includes an input port and a non-linear amplifier that renders a probe beam and a conjugate beam. The AFM includes local oscillators having a relationship with the probe beam and the conjugate beam. The displacement of the AFM's cantilever is transduced by the probe beam, and/or the conjugate beam or their respective local oscillators. The AFM's phase-sensitive detectors detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. The detected phase modulation corresponds to the change in phase. The AFM's circuitry measures phase signals that are indicative of the cantilever displacement. The resulting measurement signals exhibit a quantum noise reduction in either the intensity difference or phase sum quadrature.

Pooser, Raphael C.↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

Lukens, Joseph M.↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

Lukens, Joseph M.↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗

Photothermal Interferometer (PTI) BBOP

Aerosol Light Absorption at 532 nm using Photothermal Interferometry Time resolution: 10 sec Data normalized to STP Location: Memphis (TN) or Pasco (WA) Calibration: NO2 DateTime_PTI: UTC Absorption coefficient (PTI): Mm-1 Comments or requests are to be directed to Art Sedlacek (sedlacek@bnl.gov)

54 ENVIRONMENTAL SCIENCES↗