Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

First conduction cooled photoinjector status

SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb3Sn and conduction cooling. SRF gun can provide a CW operation capability while consuming only 2W of RF power which eliminates the need of an expensive high power RF system and saves a facility footprint. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. We aim for generation of the first beam in 2024. In this paper, we present the most up-to-date progress including results of the first cool down of the gun-cavity in the newly developed conduction cooled cryomodule and LLRF system development.

43 PARTICLE ACCELERATORS↗

Long Term Per-Component Power and Thermal Measurements of the OLCF Summit System

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide a dataset that records the long-term power and thermal behavior of the 200PF pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), Summit. This system is an IBM AC922 based system that has 9,252 IBM Power9 CPUs and 27,756 Nvidia V100 GPUs and can consume up to 13MW power at peak. Heat removal is performed using medium temperature direct liquid cooling and rear-door heat exchanger based secondary cooling loop. Originally extracted from a high-resolution (1Hz) per-component (GPUs, CPUs) measurements from the system, we primarily provide a dataset that has 10-second and 1-minute mean power and thermal measurements selected from five month-long segments over the course of 2020 (January and August), 2021 (February and August), and 2022 (January). For convenience, we also provide various sub datasets randomly sampled from the time and space (hosts) of the cluster. Further details and example code for analysis can be found in the following GitHub repository: https://github.com/at-aaims/summit_power_and_thermal_data

97 MATHEMATICS AND COMPUTING↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid depletion analysis of flowing-pebble reactor systems at equilibrium using SCALE

Several high-temperature gas-cooled reactor concepts (and more recently, salt-cooled designs such as the fluoride salt-cooled high-temperature reactor) feature core designs employing continuously circulating fuel pebbles. These reactor designs permit both continuous online refueling of fuel elements as well as higher overall achievable discharge burnups. However, rapid calculation of time-dependent fuel isotopic inventories proves challenging for this class of dynamic systems with current analysis tools. While iterative approaches employing coupled neutron transport have been developed to solve this issue, rapid depletion analysis techniques are needed to calculate time-dependent inventories for individual pebbles and batches (and thus the construction of full- core inventory at equilibrium). We propose a depletion analysis strategy for this type of system for cores at equilibrium. Drawing upon previous neutronic analysis of the PBMR-400 equilibrium core, we demonstrate the viability of developing collapsed one-group cross section libraries suitable for performing rapid depletion analyses with SCALE. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power Profile Monitoring and Tracking Evolution of System-Wide HPC Workloads

The power & energy demands of HPC machines have grown significantly. Modern exascale HPC systems require tens of megawatts of combined power for computing resources and cooling facilities at full capacity. The current energy trend is not sustainable for future HPC systems, and there is a need to work toward the energy efficiency aspect of HPC performance. Energy awareness of the HPC applications at the job level is essential for running an efficient HPC system. This work aims to develop a pipeline to provide a production-level system-wide overview of the HPC workloads' power profile while handling evolving workloads exhibiting new power trends. We developed an open-set classification model for HPC jobs based on the properties of power profiles to continuously provide a system-wide holistic view of recently completed jobs. The pipeline helps continuously monitor the job-level power usage pattern of HPC and enables us to capture the new trends in applications' power behavior. We employed a comprehensive set of techniques to generate job-level data, custom-designed feature extraction methods to extract critical features from jobs' power profiles, clustering techniques powered by generative modeling, and open-set classification for identifying job profiles into known classes or an unknown set. With extensive evaluations, we demonstrate the effectiveness of each component in our pipeline. We provide an analysis of the resulting clusters that characterize the power profile landscape of the Summit supercomputer from more than 60K jobs executed in a year. The open-set classification classifies the known data sets into known classes with high accuracy and identifies unknown data noints with over 85% accuracy.

Karimi, Ahmad Maroof↗

Development of a scintillator based fast-ion loss detector for the Wendelstein 7-X stellarator

A new scintillator based fast-ion loss detector (FILD) system has been designed for the Wendelstein 7-X (W7-X) stellarator. The mechanical design of the system is presented here along with engineering analyses of the system. This includes an assessment of the structural loads which also considers electromagnetic forces calculated for possible disruption scenarios as well as a mode frequency analysis of the system. Furthermore, an analysis of the thermal characteristics of the actively cooled probe head under prescribed steady state and transient heat loads is presented. Finally, the optical relay system is described and its properties used to forward model synthetic camera signals using the FILDSIM code and based on theoretical fast-ion losses incident on the probe head calculated using the ASCOT5 code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comprehensive Numerical and Experimental Study for the Passive Thermal Management in Battery Modules and Packs

Cooling plates in battery packs of electric vehicles play critical roles in passive thermal management systems to reduce risks of catastrophic thermal runaway. In this work, a series of numerical simulations and experiments are carried out to unveil the role of cooling plates (both between cells and a bottom plate parallel to the cell stack) on the thermal behavior of battery modules and packs under nail penetrations. First, we investigated the role of side cooling plates on the thermal runaway propagation mitigation in battery modules (1S3P) and packs (3S3P) by varying the key parameters of the side cooling plates, such as plate thicknesses, thermal contact resistances, and materials. Then, three important factors for passive thermal management systems are identified: (i) thermal mass of side cooling plates, (ii) interfacial thermal contact resistances, and (iii) the effective heat transfer coefficients at exterior surfaces. The roles of bottom cooling plates on thermal runaway propagation mitigation in 1S3P and 1S5P battery modules are numerically investigated by comparing the thermal behavior of the modules with only side cooling plates and with both side and bottom cooling plates.

25 ENERGY STORAGE↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

The reservoir network: A new network topology for district heating and cooling

Thermal district networks are effective solutions to substitute fossil fuels with renewable energy sources for heating and cooling. Moreover, thermal networking of buildings allows energy efficiency to be further increased. The waste heat from cooling can be reused for heating in thermal district systems. Because of bidirectional energy flows between prosumers, thermal networks require new hydraulic concepts. In this work, we present a novel network topology for simultaneous heating and cooling: the reservoir network. The reservoir network is robust in operation due to hydraulic decoupling of transfer stations, integrates heat sources and heat sinks at various temperature levels and is flexible in terms of network expansion. Furthermore, we used Modelica simulations to compare the new single-pipe reservoir network to a basecase double-pipe network, taking yearly demand profiles of different building types for heating and cooling. The electric energy consumed by the heat pumps and circulations pumps differs between the reservoir and base case networks by less than 1%. However, if the reservoir network is operated with constant instead of variable mass flow rate, the total electrical consumption can increase by 48% compared to the base case. As with any other network topology, the design and control of such networks is crucial to achieving energy efficient operation. Investment costs for piping and trenching depend on the district layout and dimensioning of the network. If a ring layout is applied in a district, the reservoir network with its single-pipe configuration is more economical than other topologies. For a linear layout, the piping costs are slightly higher for the reservoir network than for the base case because of larger pipe diameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

Wyandotte Integrated Renewable Energy Strategy (WIRES 2) (Final Technical Report)

Wyandotte Municipal Services (WMS), a Michigan Municipal Utility offering electric generation, transmission & distribution, water filtration & distribution and Broadband/Video sought to deploy a set of renewable energy projects for their Electric Utility that contributed to reducing the City’s environmental and energy impact, provided examples that would encourage businesses and citizens to adopt cleaner energy practices and help WMS meet the required renewable energy standards of the State of Michigan (10% in 2015, 15% in 2021). WMS generates and delivers roughly 280,000 megawatt hours (MWh) of electricity annually to more than 10,000 homes and 1,000 businesses within the City of Wyandotte. The Wyandotte Integrated Renewable Energy Strategy – WIRES 2 resulted in deployment of a set of community-scale micro-wind turbines, evaluation and installation of energy-efficient and low-maintenance light-emitting diode (LED) street lights and park lights in highly visible locations in the City and expansion of the geothermal heating and cooling district that already included residential geothermal systems, to include larger scale business/institutional systems at the Utility’s largest electric customer and at the City Library. Finally, WMS identified the need for job training in energy efficiency and renewable energy technologies to further develop a local skilled workforce in these areas. Partially funded by the grant, the wind turbine project provides a benchmark for WMS, local businesses and residents in the evaluation of utility-scale wind v. micro-wind in an urban environment as a renewable energy strategy. Also partially funded by the grant, the LED project benefited the City of Wyandotte by reducing load on the electric system for the public utility but also reduced City costs for streetlighting, parking lot lighting and park lighting without a compromise in security. The project also resulted in a visual success that has led to additional approvals for non-Grant related LED lighting installations resulting in further reduction in the electric load in the City. Commercial Geothermal installations resulted in the Utility being able to eliminate steam customers who formerly utilized the byproduct of steam from WMS electric production. Due to the reduction in natural gas prices and the overall reduction in market purchased power, it was no longer feasible for WMS to operate its Power Plant as a base load plant and to only operate on a market dispatch philosophy when market prices dictated that WMS could produce electricity cheaper than the market purchase price. This has resulted in fewer operating days for the WMS Power Plant, resulting in less environmental impact. WMS has now completely exited the steam business and the ability to offer a geothermal option to two (2) former steam customers (BASF-Wyandotte and the Bacon Memorial Library) allowed for that. In addition, peak loads have been shaved for these two (2) large customers due to the consistent temperature offered by geothermal heating and cooling, reducing the swings associated with thermostat changes caused by outside temperature changes during extreme high and low temperatures. Finally, energy efficiency and renewable energy college-level classes at Wayne County Community College allowed a group of interested students to pursue studies in those technologies through grant provided tuition, books and course materials. This effort provided a foundation of potential future employees not only for WMS but other energy efficiency/renewable energy employers such as Franklin Energy, a partner with WMS in energy optimization efforts with Wyandotte businesses.

17 WIND ENERGY↗

Heat recovery from an electrochemical hydrogen separation system

An EHS system includes a EHS cell having an anode, a cathode, and a cooling plate disposed proximate at least one of the anode or the cathode, the cooling plate configured to receive water and configured to output steam or a mixture of water and steam. The system further includes a liquid-vapor separator (LVS) configured to receive the steam or the mixture of water and steam from the cooling plate and to separate water and steam. The LVS is configured to output water to the cooling plate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operating in a deep underground facility improves the locking of gradiometric fluxonium qubits at the sweet spots

We demonstrate flux-bias locking and operation of a gradiometric fluxonium artificial atom using two symmetric granular aluminum (grAl) loops to implement the superinductor. The gradiometric fluxonium shows two orders of magnitude suppression of sensitivity to homogeneous magnetic fields, which can be an asset for hybrid quantum systems requiring strong magnetic field biasing. By cooling down the device in an external magnetic field while crossing the metal-to-superconductor transition, the gradiometric fluxonium can be locked either at 0 or Φ 0 /2 effective flux bias, corresponding to an even or odd number of trapped fluxons, respectively. At mK temperatures, the fluxon parity prepared during initialization survives to magnetic field bias exceeding 100 Φ 0 ⁠. However, even for states biased in the vicinity of 1 Φ 0 ⁠, we observe unexpectedly short fluxon lifetimes of a few hours, which cannot be explained by thermal or quantum phase slips. When operating in a deep-underground cryostat of the Gran Sasso laboratory, the fluxon lifetimes increase to days, indicating that ionizing events activate phase slips in the grAl superinductor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring surface albedo for various crops

Surface albedo can affect the energy budget and subsequently cause localized warming or cooling of the climate. When we convert a substantial portion of lands to agriculture, land surface properties are consequently altered, including albedo. Through crop selection and management, one can increase crop albedo to obtain higher levels of localized cooling effects to mitigate global warming. Still, there is little understanding about how distinctive features of a cropping system may be responsible for elevated albedo and consequently for the cooling potential of cultivated lands. To address this pressing issue, we conducted seasonal measurements of surface reflectivity during five growing seasons on annual crops of corn-soybean–winter wheat

albedo↗

Simulations of Heat Transfer Using Tight-Fitting Twisted Tape Inserts for First Wall Cooling in Molten Salt Breeder Blankets

One of the major components in fusion energy systems is the fusion blanket, which has a vacuum vessel to contain the plasma. As part of the fusion blanket/vacuum vessel, the first wall and plasma-facing components require sufficient cooling to prevent material degradation during operation from the superheated plasma. Most fusion blanket concepts involve first wall and divertor coolant channels with heat transfer enhancements (HTEs) that are intended to withstand the incident high heat fluxes of 1 to 5 MW/m 2 . Twisted tape inserts are a proposed HTE that have been investigated previously for first wall cooling and monoblock divertor cooling channels and in other nonfusion heat transfer components. By inserting twisted tapes into straight pipes, the amount of turbulence in the system can be increased at lower Reynolds numbers by swirling the flow. This results in better heat transfer characteristics with marginal increases in frictional pressure losses. In particular, simulations of high-Prandtl-number fluids such as the proposed molten salt FLiBe in twisted tapes, which is prototypic to liquid immersion blankets, have not been previously explored. Here, in this study, we simulate various Prandtl numbers in pipes with twisted tape inserts using large eddy simulations to determine the effects of increasing Prandtl numbers on heat transfer performance. The quantities of particular interest are the Nusselt number and the friction factor, which were recovered using data reduction techniques to determine impacts on heat transfer and pressure losses. This work serves as a starting point for determining the feasibility of twisted tape inserts for liquid immersion blanket concepts.

LES↗

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗