Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

NASA Lewis Stirling SPRE testing and analysis with reduced number of cooler tubes

Free-piston Stirling power converters are candidates for high capacity space power applications. The Space Power Research Engine (SPRE), a free-piston Stirling engine coupled with a linear alternator, is being tested at the NASA Lewis Research Center in support of the Civil Space Technology Initiative. The SPRE is used as a test bed for evaluating converter modifications which have the potential to improve the converter performance and for validating computer code predictions. Reducing the number of cooler tubes on the SPRE has been identified as a modification with the potential to significantly improve power and efficiency. Experimental tests designed to investigate the effects of reducing the number of cooler tubes on converter power, efficiency and dynamics are described. Presented are test results from the converter operating with a reduced number of cooler tubes and comparisons between this data and both baseline test data and computer code predictions.

Wong, Wayne A.↗

An apparatus for the measurement of regenerator performance in pulse tube refrigerators

This paper discusses the design and construction of an apparatus to measure the ineffectiveness of regenerators used for pulse tube refrigerators. Because of the fairly large mass flow rates which occur in pulse tube refrigerators, the regenerator ineffectiveness must be made quite small. The apparatus described here allows for the measurement of the refrigerator. A low temperature heat sink of liquid nitrogen is used since it approximates the temperatures normally achieved in a one-stage pulse tube.

Rawlins, Wayne↗

The effects of crushing speed on the energy-absorption capability of composite tubes

The energy-absorption capability as a function of crushing speed was determined for Thornel 300-Fiberite 934 (Gr-E) and Kevlar-49-Fiberite 934 (K-E) composite material. Circular cross section tube specimens were crushed at speeds ranging from 0.01 to 12 m/sec. Ply orientations of the tube specimens were (0/ +/- theta)2 and (+/- theta)2 where theta = 15, 45, and 75 deg. Based upon the results of these tests, the energy-absorption capability of Gr-E and K-E was determined to be a function of crushing speed. The magnitude of the effects of crushing speed on energy-absorption capability was determined to be a function of the mechanisms that control the crushing process. The effects of crushing speed on the energy-absorption capability is related to whether the mechanical response of the crushing mechanism that controls the crushing process is a function of strain rate. Energy-absorption capability of Gr-E and K-E tubes ranged between 0 and 35 percent and 20 and 45 percent, respectively, depending upon ply orientation.

Farley, Gary L.↗

Prediction of the energy-absorption capability of composite tubes

A method of predicting the crack-related energy-absorption capability of composite tubes is presented. The method is based upon a phenomenological model of the crushing process exhibited by continuous-fiber-reinforced tubes. A finite element method is used to model the crushing process. The analysis is compared with experiments on Kevlar-epoxy and graphite-epoxy tubes. Reasonable agreement is obtained between the analysis and experiment.

Farley, Gary L.↗

Effect of interlaminar normal stresses on the uniaxial zero-to-tension fatigue behavior of graphite/epoxy tubes

Fatigue tests conducted with and without internal pressure have been found to possess approximately the same fatigue life as (+/-45)s graphite/epoxy tubes for zero-to-tension axial load-controlled conditions on an axial torsion servohydraulic apparatus. These tests therefore cannot be considered as confirmations of the suspected detrimental effect of interlaminar tensile stresses on the fatigue performance of thin-walled tubes. The addition of 90-deg plies on both the inside and the outside is found to significantly improve the tubes' static and fatigue strengths.

Krempl, Erhard↗

Robotic Tube-Gap Inspector

Robotic vision system measures small gaps between nearly parallel tubes. Robot-held video camera examines closely spaced tubes while computer determines gaps between tubes. Video monitor simultaneously displays data on gaps.

Gilbert, Jeffrey L.↗

Eddy current inspection of weld defects in tubing

An approach using differential probes for the inspection of weld defects in tubing is studied. Finite element analysis is used to model the weld regions and defects. Impedance plane signals are predicted for different weld defect types and compared wherever possible with signals from actual welds in tubing. Results show that detection and sizing of defects in tubing is possible using differential eddy current techniques. The phase angle of the impedance plane trajectory gives a good indication of the sizing of the crack. Data on the type of defect can be obtained from the shape of the impedance plane trajectory and the phase. Depending on the skin depth, detection of outer wall, inner wall, and subsurface defects is possible.

Katragadda, G.↗

Two-phase pressure drop of ammonia in small diameter horizontal tubes

Data for pressure drop in adiabatic two-phase ammonia flows in small diameter horizontal tubes are presented. The data has direct application to the sizing of the flow-through radiator tubes in the Space Station Freedom heat rejection system. The data are compared to existing correlations for pressure drop and are found to be significantly lower than the most commonly used correlations. However, several of the less commonly used correlations predict the data accurately. Alternate pressure drop prediction methods are explored and a recommendation is made for a method to accurately predict the pressure drop in two-phase ammonia flows in small horizontal tubes.

Ungar, Eugene K.↗

Gas detector tube applications on Space Station Freedom

The Space Station Freedom (SSF) program requires measurements, by gas detector tubes, of trace contaminants (mainly CO and toluene didsocyanate) in the Node 2 (which is isolated from the trace contaminant control system for about 100 days during the SSF building missions) and Lab A atmosphere prior to the first entry of the crew. This paper discusses the results of an analysis of the levels of trace contaminants that can be expected in the Node 2 atmosphere at 100 days and the aspects of the detector tube design and technology which may need further developent for application in microgravity. Attention is also given to the factors governing the use of detector tubes for monitoring selected contaminants.

Shah, Burt H.↗

Hypervelocity flows of argon produced in a free piston driven expansion tube

An expansion tube with a free piston driver has been used to generate quasi-steady hypersonic flows in argon at flow velocities in excess of 9 km/s. Irregular test flow unsteadiness has limited the performance of previous expansion tubes. Test section measurements of pitot pressure, static pressure, and flat plate heat transfer rates are used to confirm the presence of quasi-steady flow, and comparisons are made with predictions for the equilibrium flow of an ideal, ionizing, monatomic gas. The results of this work indicate that expansion tubes can be used to generate quasi-steady hypersonic flows in argon at speeds in excess of Earth orbital velocity.

Neely, A. J.↗

Comparative Tests of Pitot-static Tubes

Comparative tests were made on seven conventional Pitot-static tubes to determine their static, dynamic, and resultant errors. The effect of varying the dynamic opening, static opening, wall thickness, and inner-tube diameter was investigated. Pressure-distribution measurements showing stem and tip effects were also made. A tentative design for a standard Pitot-static tube for use in measuring air velocity is submitted.

Merriam, Kenneth G↗

Torsional Stability of Aluminum Alloy Seamless Tubing

Torsion tests were made on 51ST aluminum-alloy seamless tubes having diameter-to-thickness ratios of from 77 to 139 and length-to-diameter ratios of from 1 to 60. The torsional strengths developed in the tubes which failed elastically (all tubes having lengths greater than 2 to 6 times the diameter) were in most cases within 10 percent of the value indicated by the theories of Donnel, Timoshenko, and Sturm, assuming a condition of simply supported ends.

Moore, R L↗

Round Heat-treated Chromium-molybdenum-steel Tubing Under Combined Loads

The results of tests of round heat-treated chromium-molybdenum-steel tubing are presented. Tests were made on tubing under axial load, bending load, torsional load, combined bending and axial load, combined bending and torsional load, and combined axial, bending, and torsional load. Tensile and compressive tests were made to determine the properties of the material. Formulas are given for the evaluation of the maximum strength of this steel tubing under individual or combined loads. The solution of an example is included to show the procedure to be followed in designing a tubular cantilever member to carry combined loads.

Osgood, William R↗

Correlation of Forced-convection Heat-transfer Data for Air Flowing in Smooth Platinum Tube with Long-approach Entrance at High Surface and Inlet-air Temperatures

A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.

Desmon, Leland G↗

Variation of pressure limits of flame propagation with tube diameter for various isooctane-oxygen-nitrogen mixtures

An investigation was made of the change in the pressure limits of flame propagation with tube diameter for various isooctane-oxygen-nitrogen mixtures. Pressure limits were measured in cylindrical glass tubes of four different inside diameters at six different oxygen-nitrogen ratios. Under the experimental conditions, flame propagation was found to be impossible in isooctane-oxygen mixtures with oxygen concentrations less than 11 to 12 percent. Critical tube diameters for flame propagation were calculated and the effect of pressure was determined and compared with the effect of pressure on quenching distance. Critical diameters were related to flame speeds for various isooctane-oxygen-nitrogen mixtures.

FUELS-PROPERTIES,PHYSICAL AND CHEMICAL↗

Variation of the pressure limits of flame propagation with tube diameter for propane-air mixtures

An investigation was made of the variation of the pressure limits of flame propagation with tube diameter for quiescent propane with tube diameter for quiescent propane-air mixtures. Pressure limits were measured in glass tubes of six different inside diameters, with a precise apparatus. Critical diameters for flame propagation were calculated and the effect of pressure was determined. The critical diameters depended on the pressure to the -0.97 power for stoichiometric mixtures. The pressure dependence decreased with decreasing propane concentration. Critical diameters were related to quenching distance, flame speeds, and minimum ignition energy.

TEST APPARATUS - FLAME PROPOGATION - LFPL↗

Pressure Drop in Radiator Air Tubes

This report describes a method for measuring the drop in static pressure of air flowing through a radiator and shows (1) a reason for the discrepancy noted by various observers between head resistance and drop in pressure; (2) a difference in degree of contraction of the jet in entering a circular cell and a square cell; (3) the ratio of internal frictional resistance to total head resistance for two representative types; (4) the effect of smoothness of surface on pressure gradient; and (5) the effects of supplying heat to the radiator on pressure gradient. The fact that the pressure gradients are found to be approximately proportional to the square of the rate of flow of air appears to indicate turbulent flow, even in the short tubes of the radiator. It was found that the drop in the static pressure in the air stream through a cellular radiator and the pressure gradient in the air tubes are practically proportional to the square of the air flow in a given air density; that the difference between the head resistance per unit area and the fall of static pressure through the air tubes in radiators is apparent rather than real; and that radiators of different types differ widely in the amount of contraction of the jet at entrance. The frictional resistance was found to vary considerably, and in one case to be two-thirds of the head resistance in the type using circular cells and one-half of the head resistance of the radiator type using square cells of approximately the same dimensions.

Parsons, S R↗

Discharging Static Electricity From Inside A Glass Tube

Device that contains emitter of alpha particles discharges static electricity from inside wall of glass tube of volumetric-flow calibrator. Includes cylinder that has wall thickness of 1/16 in., diameter about 1/2 in. smaller than inside diameter of tube, and height that extends about 1/2 in. above piston that moves along tube and is part of calibrator.

Ellsbury, Walter L.↗