Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optimal Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Quantum/AI Topology-Aware Latency-Adaptive HPC Workflow Scheduling Optimization

The growing demand for more powerful high-performance computing (HPC) systems has led to a steady rise in energy consumption by supercomputing worldwide. This study is focused on comparing our Application-Topology Mapper (ATMapper) to the popular Simple Linux Utility for Resource Management (SLURM) for the purpose of exploring methods that can further optimize job-scheduling within HPC systems. ATMapper is an Artificial-Intelligence based approach to job-scheduling that is currently being enhanced with quantum annealing (QA) to generate optimal schedules faster. We are applying QA to speedup our ATMapper process to achieve higher computing efficiency, thereby reducing HPC energy consumption. Here, we examine how four job-scheduling approaches perform in processor node assignment when using an example network architecture of 4 interconnected nodes. Using a specialized script, we are assessing the schedule of a computation flow with 11 interdependent tasks. The data movements among nodes were tracked to count for the number of interactions (network hops) between nodes needed to complete the tasks. The total number of hops and the job completion time were then used to quantify the efficiency of the different mapping approaches. In addition to SLURM, we also compare our ATMapper to the QA-enabled LBNL TIGER and the D-Wave Distributed Computing processor assignment approaches. The preliminary results showed that our topology-aware, latency-adaptive ATMapper is significantly more efficient when compared to the other scheduling approaches due to its load-imbalance network allocation. The scheduler displayed a computing efficiency of 53% by performing significantly fewer network hops than its alternatives. By reducing the number of hops, ATMapper was able to perform all 11 tasks by using only 3 nodes out of given 4. This research indicates the potential to use QA/AI for HPC job-scheduling. Later, we will test a SLURM simulator program to draw further comparisons on the effectiveness of ATMapper's scheduling approach. The results of this comparison will serve as a baseline for later improving SLURM's performance using a QA-enhanced ATMapper approach.

Caraveo, Braulio [University of Huston - Clear Lak↗

Acoustic propagation in curved ducts with extended reacting wall treatment

A finite-element Galerkin formulation was employed to study the attenuation of acoustic waves propagating in two-dimensional S-curved ducts with absorbing walls without a mean flow. The reflection and transmission at the entrance and the exit of a curved duct were determined by coupling the finite-element solutions in the curved duct to the eigenfunctions of an infinite, uniform, hard wall duct. In the frequency range where the duct height and acoustic wave length are nearly equal, the effects of duct length, curvature (duct offset) and absorber thickness were examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. A means of reducing the number of elements in the absorber region was also presented. In addition, for a curved duct, power attenuation contours were examined to determine conditions for maximum acoustic power absorption. Again, wall curvature was found to significantly effect the optimization process.

Baumeister, Kenneth J.↗

Multi-Scale Simulation of Wind Farm Performance during a Frontal Passage

Predicting the response of wind farms to changing flow conditions is necessary for optimal design and operation. Here in this work, simulation and analysis of a frontal passage through a utility scale wind farm is achieved for the first time using a seamless multi-scale modeling approach. A generalized actuator disk (GAD) wind turbine model is used to represent turbine–flow interaction, and results are compared to novel radar observations during the frontal passage. The Weather Research and Forecasting (WRF) model is employed with a nested grid setup that allows for coupling between multi-scale atmospheric conditions and turbine response. Starting with mesoscale forcing, the atmosphere is dynamically downscaled to the region of interest, where the interaction between turbulent flows and individual wind turbines is simulated with 10 m grid spacing. Several improvements are made to the GAD model to mimic realistic turbine operation, including a yawing capability and a power output calculation. Ultimately, the model is able to capture both the dynamics of the frontal passage and the turbine response; predictions show good agreement with observed background velocity, turbine wake structure, and power output after accounting for a phase shift in the mesoscale forcing. This study demonstrates the utility of the WRF-GAD model framework for simulating wind farm performance under complex atmospheric conditions.

17 WIND ENERGY↗

Feasibility Study of Velocity and Temperature Measurements of an Arcjet Flow using Laser Resonance Doppler Velocimetric (LRDV) Technique

Thermal Protection System (TPS) materials are used in space vehicles to shield from high heating environment encountered during their atmospheric reentry. Arcjet wind tunnels are used to simulate the flowfield encountered by the spacecrafts, and are used for testing TPS materials. How well these tests simulate the actual heating environment encountered by space vehicles depends on the characteristics of the simulated flow. The flow characterization requires the determination of temperature, concentration, and velocity of the various atomic and molecular species present in the flow. However, determining these parameters requires a complex set of both analytical and experimental procedures. The ability to properly simulate the flight environment is directly related to the accuracy with which these techniques can be used to define the arcjet Laser Resonance Doppler Velocimetric (LRDV) technique can be used to accurately determine the velocity and temperature of a gaseous species. In this technique, the medium is probed with a laser beam that is in resonance with an absorbing transition of the species. The absorption lineshape is Doppler-shifted due to the flow velocity of the species, and the frequency shift is detected as the variation in intensity of the fluorescence emitted by the species. Thus a measurement of the Doppler shift and the width of a spectral line can give both the temperature and the velocity of the flowfield. This summer, our project was to make a feasibility study to set up an experimental arrangement for the laser resonance Doppler velocimetric technique using a ring dye laser. Experiments required troubleshooting, cleaning, testing, and alignment of two lasers and several diagnostics instruments. All instruments and lasers necessary for the project worked well, but the output power of the broadband fundamental dye laser was limited to about 20 mW. This was quite low as compared to that necessary to obtain second harmonic oscillation at 327.49 nm for the LRDV studies. Further optimization of the dye laser optical elements is necessary before it can be used for the experiment, which requires narrowband (about 20 Mhz) laser operation.

Rob, Mohammad A.↗

On-Orbit Xenon Refueling Loading Times and Transient Analysis

The Power and Propulsion Element (PPE) of the Lunar Orbital Platform-Gateway will demonstrate the first on-orbit refueling of xenon propellant for a solar electric propulsion system. An analysis was performed in Microsoft Excel to determine what factors influence the overall refueling time of a single 2,000-kilogram capacity xenon propellant tank, as well as provide estimates for overall refueling duration. Due to the high heat of compression of xenon, the propellant tank could exceed its maximum allowable temperature during refueling if the xenon flow rate and temperature are unregulated. In order to prevent overheating, a logic based "bang-bang" operation was used for refueling, shutting off the mass feed when the tank reached a maximum temperature. Heat is removed from the tank via radiation to the surrounding spacecraft bus. The analysis shows that optimizing key parameters such as mass flow rate into the tank, residual propellant in the tank during the onset of refueling, and tank diameter significantly reduces the overall refueling duration. Optimization is not straightforward, however, as the loading time does not trend monotonically with the parameters. Overall, the most significant impact on loading duration comes from altering the residual propellant in the tank. Increasing the mass of residual propellant from 2 percent to 20 percent reduces the overall refueling duration by 56 percent. Future work based on this analysis includes creation of a SINDA/FLUINT model and building a ground-based xenon refueling system emulator.

Xenon↗

Phase I Final Technical Report on Energy-Efficient Reconfigurable Universal Accelerator Interconnect

It is well known that application specific computing systems, optimally designed and configured for a given workload, offer much higher energy-efficiency and throughput than general purpose systems. In modern computing systems, heterogeneous computing systems have emerged that exploit the energy and performance benefits of combining various different domain-specific processor architectures. Application domains such as high-performance computing and machine learning now process terabyte-sized data sets, requiring enormous processing and memory resources. These applications have very high-power consumption due to bottlenecks in the electrical interconnection between processing units. This project aims to reduce both communication energy and latency by integrating universally available accelerators with silicon photonics. It also aims to increase system throughput by exploiting emerging technologies in silicon photonic reconfigurable interconnects; this will allow the system to balance itself in real time to accommodate changes in workloads and data flows.

2.5D/3D integration↗

HFIR LEU High Density Silicide Dispersion Optimized Design Steady-State Heat Transfer Analyses

Steady-state heat transfer simulations of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) with the low-enriched uranium (LEU) high-density silicide dispersion Optimized fuel design were performed to support comprehensive performance and safety metric studies concerning this design. The LEU Optimized design operates at 95 MW to maintain HFIR’s current highly enriched uranium (HEU) core performance level at 85 MW. Full cycle Mode 1 full flow Case 1 (inlet temperature), Case 2 (flux-to-flow), and Case 3 (inlet pressure) safety limit analyses were performed to assess the margins to critical heat flux. Under the prescribed conditions, this LEU design meets the safety limit and limiting control setting requirements outlined in HFIR’s documented safety analysis; however, the safety margins are less than those for the 85 MW HEU core, and several assumptions were made where fuel fabrication and qualification data are currently lacking for the silicide fuel design. Effects of changes to pertinent fuel fabrication assumptions and uncertainty factors on thermal safety margins were also evaluated, showing that the margins are sensitive to many of these parameters. Power and pressure perturbations were also performed, indicating that significant steady-state thermal margins could be gained by increasing the coolant inlet pressure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

COMSOL Results for the Nominal Steady-State Operation of the Proposed 95-MW LEU Silicide Core for HFIR Conversion

Engineering design studies are being performed to determine the feasibility of converting the High Flux Isotope Reactor (HFIR) from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel at Oak Ridge National Laboratory. This activity is sponsored by the Office of Reactor Conversion and Uranium Supply (ORCUS) under the auspices of the US Department of Energy National Nuclear Security Administration’s Office of Material Management and Minimization. HFIR is a very high flux, pressurized, light water–cooled and moderated, flux trap–type research reactor with a core made of involute shaped U 3 O 8 /Al cermet fuel plates and coolant channels. HFIR currently operates at a thermal power of 85 MW and supports key national and international missions in neutron scattering, isotope production, materials/fuels irradiation, neutron activation analysis, gamma irradiation, and neutrino research. Advanced multiphysics computational fluid dynamics models have been developed in the COMSOL Multiphysics software to simulate the steady-state operating conditions for the proposed low-and high-density LEU U 3 Si 2 -Al (uranium silicide dispersion) fuel designs. The COMSOL models for HFIR inner and outer fuel element models incorporate various essential inputs and physics such as spatially dependent nuclear heat deposition, multilayer heat conduction, conjugate heat transfer, turbulent flows (using Reynolds-averaged Navier Stokes turbulence models), structural mechanics (thermal–structural interactions and fuel swelling), and oxide layer build-up. This report presents the best-estimate thermal hydraulics results for the low- and high-density optimized silicide LEU core designs at 95 MW steady-state nominal operation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NASA Tech Briefs, September 2005

Topivs include: Diamond-Coated Carbon Nanotubes for Efficient Field Emission; Improved Anode Coatings for Direct Methanol Fuel Cells; Advanced Ablative Insulators and Methods of Making Them; PETIs as High-Temperature Resin-Transfer-Molding Materials; Stable Polyimides for Terrestrial and Space Uses; Low-Density, Aerogel-Filled Thermal-Insulation Tiles; High-Performance Polymers Having Low Melt Viscosities; Nonflammable, Hydrophobic Aerogel Composites for Insulation; Front-Side Microstrip Line Feeding a Raised Antenna Patch; Medium-Frequency Pseudonoise Georadar; Facilitating Navigation Through Large Archives; Program for Weibull Analysis of Fatigue Data; Comprehensive Micromechanics-Analysis Code - Version 4.0; Component-Based Visualization System; Software for Engineering Simulations of a Spacecraft; LabVIEW Interface for PCI-SpaceWire Interface Card; Path Following with Slip Compensation for a Mars Rover; International Space Station Electric Power System Performance Code-SPACE; Software for Automation of Real-Time Agents, Version 2; Software for Optimizing Plans Involving Interdependent Goals; Computing Gravitational Fields of Finite-Sized Bodies; Custom Sky-Image Mosaics from NASA's Information Power Grid; ANTLR Tree Grammar Generator and Extensions; Generic Kalman Filter Software; Alignment Stage for a Cryogenic Dilatometer; Rugged Iris Mechanism; Treatments To Produce Stabilized Aluminum Mirrors for Cryogenic Uses; Making AlNx Tunnel Barriers Using a Low-Energy Nitrogen-Ion Beam; Making Wide-IF SIS Mixers with Suspended Metal-Beam Leads; Sol-Gel Glass Holographic Light-Shaping Diffusers; Automated Counting of Particles To Quantify Cleanliness; Phase Correction for GPS Antenna with Nonunique Phase Center; Compact Infrasonic Windscreen; Broadband External-Cavity Diode Laser; High-Efficiency Solar Cells Using Photonic-Bandgap Materials; Generating Solid Models from Topographical Data; Computationally Lightweight Air-Traffic-Control Simulation; Spool Valve for Switching Air Flows Between Two Beds; Partial Model of Insulator/ Insulator Contact Charging; Asymmetric Electrostatic Radiation Shielding for Spacecraft; and Reusable Hybrid Propellant Modules for Outer-Space Transport.

Source record↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines: Preprint

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be timeconsuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the towerbase damage equivalent loading and better tracking of the rated generator speed and power.

closed-loop control↗

Carbon Capture through Membranes - Leveraging Multiphysics Modeling, Dimensional Analysis and Machine Learning to Scale up and Optimize Devices and Processes for Decarbonization

We study the separation performance using membrane modules through dimensional analysis (DA). We formulate the main process equations to identify relevant dimensionless numbers inherent in the physics. In particular, we identify that the critical step in the separation process is mass transfer through the selective layer. Remarkably, the dimensionless feed flow (DFfeed) emerges as a crucial factor in describing this process. Not only does DFfeed directly appear in the governing equations, but it also holds a physical significance associated with the time scales for the mass transfer across the feed side and through the selective layer. Regarding the output performance variables, we consider the recovery, stage cut, productivity and purity. In this context, we profit from experimental data and CFD simulations to evaluate the separation performance of the modules when varying the input flowrate, the scale of the module, and the CO2 permeance. These datasets enable us to establish correlations between performance metrics and the dimensionless feed flow (DFfeed). Using simple power functions of DFfeed, we obtain R2 coefficients exceeding 0.99, indicating the accuracy of the correlations built in the present work. In the future, we wish to use DA to understand key transport mechanisms, predict and control module performance, and challenge the universality of these findings by testing various gas separations across different membrane modules beyond our case study.

Pedrozo, Hector A.↗

Characterizing Impacts of Dry Coal Feeding in High Pressure Oxy-Coal Combustion Systems

Reaction Engineering International (REI) has managed a team of experts from the University of Utah, Southeast University (SEU) in Nanjing, China, Electric Power Research Institute (EPRI), Corrosion Management Ltd. (C-M), Praxair, and Brigham Young University (BYU) to investigate dry pulverized coal feeding for pressurized oxy-coal combustion. Dry feed firing systems for entrained flow, pressurized, oxy-coal combustors have not been well developed, although related technologies have been used in the Shell Gasification Process and for pressurized fluid bed combustion. DOE-funded research recently completed at REI and the University of Utah focused on characterizing impacts of high temperatures and pressures in oxy-coal combustion systems. For high pressure combustion, that research used a coal slurry feed into a 17 bar pressurized combustor. As a consequence of that research, it was identified that fuel feeding and firing system flexibility are challenges that require attention. Based on that experience, the approach of using a coal slurry feed system leads to challenges in producing consistent atomization of the slurry, which causes burnout problems, especially at high pressures. In addition, slurry atomization processes may be difficult to scale to sizes appropriate for practical commercial use. Dry pressurized coal burner systems, on the other hand, have the potential to yield efficiency gains, improve flexibility and facilitate applications at larger scales. Experimental work was conducted at the University of Utah Industrial Combustion and Gasification Research Facility as well as the 100 kW pressurized oxy-coal combustor (POC) facility at Brigham Young University. Mechanism development and CFD-based combustion and dense-phase flow modeling were performed at REI. Successful completion of the project objectives has resulted in the following key deliverables: 1) Design and prototype of a pressurized pulverized coal feeding and oxy-firing system 2) Data from a 100kW, pressurized (15 bar) entrained flow reactor with a dry feeding delivery and burner system that describes flame characteristics, radiative heat flux profiles, carbon burnout, along with characteristics of ash aerosols, fouling, and slagging. 3) Validated and transportable models that describe the relevant conditions in pressurized oxy-combustion systems and that can be used for scale-up and optimization. 4) Principles to guide design of high pressure, pilot-scale and full-scale coal oxy-firing systems. 5) Assessment of pressurized oxy-combustion impacts on key parameters relevant to oxy-coal fired utility boilers such as coal devolatilization, char oxidation, mineral matter transformation, deposition, and corrosion. The experimental data, pressurized oxy-firing system principles, and process mechanisms provided by this work can be used by electric utilities, boiler OEMs, equipment suppliers, design firms, software vendors, consultants and government agencies to assess the use of high temperature and high pressure oxy-combustion in current research and to guide development of new oxy-coal boiler designs.

01 COAL, LIGNITE, AND PEAT↗

Numerical Modeling of a Two-Stage Ocean Current Turbine

The Equinox Ocean Turbines (EQOT) current energy converter has a unique design with power generation in two small-diameter turbines attached to the tips of a large-diameter passive rotor. This configuration offers some key advantages for capturing ocean currents. With no centrally placed generator, almost no reaction torque is required at the nacelle of the main large-diameter rotor, and the small-diameter tip turbine generators operate at a higher speed and lower torque. The physics that determine the performance and loads on the turbine are also unique. The interactions of the flow field between the two stages and the general architecture of the system cannot be captured with traditional mid-fidelity modeling tools. For design iterations and large sets of load cases, it is important to have mid-fidelity models that can capture the important phenomenon with enough accuracy to identify global trends. This work uses a limited set of high-fidelity computational fluid dynamics (CFD) simulations to help inform the selection of and construction of a custom mid-fidelity model. Mid-fidelity modeling approaches were verified by comparing key turbine performance quantities to those found with the CFD model. Hydrodynamic interactions of the two-stage rotor were identified through high-fidelity CFD modeling. This highlighted the impact of the main rotor tip vortex and wake on the secondary rotor apparent inflow. This results in a relative flow rotation and sharp deficit, that change the optimal secondary rotor rotation speed and adds unsteadiness to the blade loading respectively. Multiple mid-fidelity approaches were evaluated for their ability to capture these effects. A simple approximation of the combined-stage performance based on single-stage BEM provides a reasonable rough prediction, especially near the peak TSR values, with some larger discrepancy at higher TSRs. Predicting the combined-stage performance based on single-stage CFD data improves this prediction across the TSR range. Although the combined-stage modeling in OLAF was not successful in this stage of the project, it showed promise as a mid-fidelity method, assuming the parameters can be tuned to account for the significant differences in time and length scales between the main and secondary rotors. This may be addressed through code changes in future work. A significant finding from the OLAF work was the agreement between the vortex core radius values found independently via a parameter space search and via CFD. The technique of using single-stage secondary rotor BEM, with a custom inflow taken from single-stage main rotor CFD or OLAF, provides an efficient method to capture one-way coupled flow interactions. This method provided generally good predictions of the impact of the flow rotation on the secondary rotor but struggled to accurately predict the peaks of the unsteady load progression. Future work could include some superposition of a tuned main rotor trailing edge viscous wake into the custom inflow to better predict this interaction.

16 TIDAL AND WAVE POWER↗

Optimal Header Design for Diffusion Bonded Heat Exchangers

Microchannel heat exchangers have seen increasing adoption in many high-pressure applications in recent decades but are subject to particulate fouling from the relatively small channel size compared to traditional designs. Typical cleaning methods require process shutdown, heat exchanger removal, cleaning, then reassembly. The objective of this project was to refine and transfer technology to enable header design improvements for Cleaning-in-Place (CIP), allowing for reduced/negligible process interruption for the cleaning process. The technology transfer was from Sandia National Laboratories (Sandia) to Vacuum Process Engineering, Inc. (VPE). This primary purpose of CIP was developed while considering channel flow uniformity and heat exchanger cost. The project phases were to 1) capture and define potential improvement options, 2) evaluate options with both simulation and experiments, and 3) transfer design knowledge to the industry partner. These efforts resulted in improved header designs from the first known focused effort in this area. The improved designs will help the entire microchannel heat exchanger field that has applications in supercritical CO 2 power cycles, hydrogen (fuel cell) vehicle fueling, liquified natural gas processing, and more.

42 ENGINEERING↗

Wind tunnel tests of a symmetrical airfoil with scoop fed slots

The design and wind tunnel test of a model vertical tail fin is described in this report. The model is designed to provide the aerodynamic forces necessary for lateral stabilization without moving parts or a separate source of power. It employs scoop-fed slots on both surfaces of the symmetrical airfoil. They are to be controlled differentially by means of a fluidic amplifier to implement an automatic fulltime lateral stabilization system. The results of tests show that the control of forces is stable and quite linear in various modes of operation. Significant forces were produced that can be increased as necessary by increasing slot size and scoop size. Slots can be located ahead of the conventional rudder and the scoop can be at the base of the vertical tail fin to avoid the need for major changes in conventional aircraft design. The first phase of the work demonstrated the feasibility of no-moving-parts aircraft control. The second phase established that a practical fluidic amplifier can be built to control slot flows from fluidic signals. Recommendations are made to optimize the design of the fluidic amplifier and to characterize its dynamic response in support of further analytical studies.

Belsterling, C. A.↗

Learning to Control Advanced Life Support Systems

Advanced life support systems have many interacting processes and limited resources. Controlling and optimizing advanced life support systems presents unique challenges. In particular, advanced life support systems are nonlinear coupled dynamical systems and it is difficult for humans to take all interactions into account to design an effective control strategy. In this project. we developed several reinforcement learning controllers that actively explore the space of possible control strategies, guided by rewards from a user specified long term objective function. We evaluated these controllers using a discrete event simulation of an advanced life support system. This simulation, called BioSim, designed by Nasa scientists David Kortenkamp and Scott Bell has multiple, interacting life support modules including crew, food production, air revitalization, water recovery, solid waste incineration and power. They are implemented in a consumer/producer relationship in which certain modules produce resources that are consumed by other modules. Stores hold resources between modules. Control of this simulation is via adjusting flows of resources between modules and into/out of stores. We developed adaptive algorithms that control the flow of resources in BioSim. Our learning algorithms discovered several ingenious strategies for maximizing mission length by controlling the air and water recycling systems as well as crop planting schedules. By exploiting non-linearities in the overall system dynamics, the learned controllers easily out- performed controllers written by human experts. In sum, we accomplished three goals. We (1) developed foundations for learning models of coupled dynamical systems by active exploration of the state space, (2) developed and tested algorithms that learn to efficiently control air and water recycling processes as well as crop scheduling in Biosim, and (3) developed an understanding of the role machine learning in designing control systems for advanced life support.

Subramanian, Devika↗

Optimization-Inspired Pin-Fin Array for Supercritical Carbon Dioxide Recuperator

Additively manufactured heat exchangers are one possible route to cost-effective sCO 2 power cycles. In this paper, experimental results are obtained for two helical pin fin tubes that were designed following parametric optimization of the fin array. Neither the numerical optimization nor the experimental testing have been previously reported in the literature. The two tube designs were, (1) the optimization inspired design, and (2) the optimization-inspired design with a fin diameter increased by a factor of 2. To characterize the print, the designs were scanned using X-ray computed tomography to measure feature sizes and heat transfer area. The optimization was conducted in a commercial, computational fluid dynamics code. The code solved the Reynolds Averaged Navier-Stokes (RANS) and energy equations with turbulence closure provided by the shear stress transport (SST) k-ω model. In the experiments, the Nusselt number augmentation was measured using the Wilson plot technique and the friction factor was determined with mass flow and pressure drop measurements. The experimental testing indicated that the optimization-inspired design had a friction factor that was four times less than the baseline tube design at equal Nusselt number. Additionally, the optimization-inspired design had a 14% improvement in Nusselt number, at equal friction factor, relative to the best performing computational fluid dynamics (CFD) trial points. Tube design (2), with the larger diameter pin fins, had similar performance, within experimental error, as the tube with the smaller diameter pin fins (1). Both tubes achieved overall fin array efficiencies near 1. A performance factor, V/V 0 , equal to the volume of the enhanced heat exchanger divided by the volume of the baseline (no-fins) heat exchanger, is recommended to quantify internal cooling performance. In conclusion, the experimental shell and tube heat exchanger, using the additively manufactured tube, is competitive with printed circuit heat exchangers in its pressure drop class and could be further improved by optimizing a shell-and-tube heat exchanger utilizing this heat transfer enhancement feature.

42 ENGINEERING↗