Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiscale analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

934 records · Page 52

Advances in Design Capabilities for Planetary Missions from the NASA Entry Systems Modeling and Instrumentation Portfolio

The Entry Systems Modeling project (ESM) is supported by both the NASA Space Technology and the Science Mission Directorates and focuses on developing simulation tools and validated models for characterizing the performance of entry systems tailored to planetary destinations across the Solar System. ESM is organized into six technical capability areas that together address all relevant factors related to spacecraft entry, as well as some aspects of descent: Thermal Protection System (TPS) Materials; Aerothermodynamics; Entry & Descent Vehicle Dynamics; Guidance, Navigation, and Control; Vehicle Systems Analysis; and Advanced Tools and Numerical Methods. Development within the capability areas is undertaken explicitly with a focus on transition and infusion to science missions, human exploration missions, and commercial space activities. The present talk details developments that specifically impact science missions, including simulation tool capabilities that aid in mission design and model development to understand entry system performance at a given destination. Examples of the successful infusion and transition of such project outcomes to science missions also are provided. Several simulation tool development efforts within ESM have resulted in new design capabilities for missions. One such outcome is improved toolsets for mission trajectory and concept of operations design. Specifically, an initiative to couple a leading tool for entry, ascent/descent, and orbital trajectory optimization (Program to Optimize Simulated Trajectories II or POST2) to those used within the Agency for interplanetary trajectory optimization (Copernicus and Monte) has made substantial progress, with the outcomes to date promising to allow efficient trajectory optimization across mission phases. Additionally, toolchains for the evaluation of vehicle performance during entry and descent have been developed that allow assessment of multi-dimensional aeroheating on detailed vehicle geometries, characterization of deployment and inflation of parachutes, and assessment of vehicle dynamic stability during descent. These capabilities are achieved by coupling diverse sets of physics together – material response, computational fluid dynamics, radiation, and vehicle dynamics – to suitably describe complex entry and descent phenomena. Several model development and validation efforts for specific destinations and entry regimes also are underway within the ESM project. For instance, new experimental capabilities to validate radiation models at low densities/high altitudes recently have been established with project support, specifically the Low-Density Shock Tube (LDST) at the NASA Ames Research Center Electric Arc Shock Tube (EAST) facility. The LDST is being leveraged to develop improved models of shock layer kinetics and radiation in Titan atmospheres, while future studies will be conducted in the LDST and the existing high velocity shock tube to provide validation data for radiation models of Venus, Ice Giants, and Mars atmospheres. Models describing the aerothermal and thermo-structural performance of Thermal Protection System (TPS) materials has been another focus, with multiscale modeling activities on-going for the two leading TPS materials applicable to a range of entry conditions and science missions: the Phenolic-Impregnated Carbon Ablator (PICA) and woven materials like 3D Mid-Density Carbon Phenolic (3MDCP). A continual effort is made to infuse and transition outcomes from ESM simulation tool and model development activities into relevant science missions. Significant progress has been made on this front, with missions such as Dragonfly, DAVINCI, and Mars Missions benefitting from project outcomes. The groundwork also is being laid to provide insights into forward looking missions to Gas/Ice Giants as well as for potential sample returns.

Justin Haskins↗

Multi-Scale Integrated Monitoring System for Enhancing Methane Emission Detection, Quantification & Prediction

This report details the progress and findings of a comprehensive study on reviewing existing solutions, identifying technology gaps, and formulating an “all-in-one” integrated strategy for developing the next-generation multiscale methane monitoring and modeling platform, conducted under grant number DE-FE0032292. Co-led by Dr. David Ebert, Dr. Binbin Weng, and Dr. Chenghao Wang at the University of Oklahoma, the project’s goal was to develop an integrated approach for building this engineering platform to detect, quantify, and mitigate methane emissions across various temporal scale, spatial scales, and sectors. The planning grant study began with an extensive review of various methane sensing and monitoring technologies and systems, surveying over 100 technology providers globally. This review revealed the prevalence of optical methods over chemical methods in commercially available sensors, with Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Optical Gas Imaging (OGI) cameras being the most prevalent options. A trend towards more advanced optical techniques was observed, driven by increased regulatory focus and technological advancements. The technical evaluation of these sensing technologies provided crucial insights into their capabilities and limitations. The study examined emerging technologies such as Differential Absorption LiDAR (DIAL), which show promise for high-precision and long-range detection. The team then investigated the features and application bandwidth of various sensing platforms, including handheld, fixed/stationary, mobile, aerials, and spaceborne monitors. Pilot field studies were conducted to assess the capabilities of solutions for different emission scenarios. Field work with sensor deployments was conducted at three distinct site types: an oil & gas industry site, a cattle ranching operation, and a waste processing facility. The team also conducted a thorough review of methane flux inverse modeling approaches, focused on physically based methods. These approaches were categorized into simple, intermediate, and advanced methods. A realtime WRF-GHG (Weather Research and Forecasting-Greenhouse Gas) modeling system was developed and applied, incorporating multiple data sources to guide field experiments and inform methane plume detection. The project identified and analyzed numerous categories of methane data sources, including satellite measurements, ground-based sensors, and inventory databases. Key platforms examined include EDGAR, EPA GHGI, NASA TROPOMI, Carbon Mapper, and Climate TRACE, among others. The team proposed an architecture for a comprehensive methane monitoring platform. This system incorporates multi-source data acquisition, advanced data processing and assimilation, interactive visualization tools, and analytical capabilities for emissions forecasting and scenario analysis. The proposed platform aims to provide a user-friendly interface catering to various stakeholders, from researchers to policymakers. The architecture includes sophisticated data ingestion methods, a centralized data warehouse, and advanced analytical tools for data fusion and interpretation. To ensure the relevance and effectiveness of the proposed system, a comprehensive survey was conducted to gather stakeholder input on system requirements. Key findings include a strong need for integrating various data types and formats, a preference for real-time data updates and advanced visualization tools, and a demand for user-friendly interfaces catering to different expertise levels.

03 NATURAL GAS↗

Solid-state Architecture Batteries for Enhanced Rechargeability and Safety (SABERS) for Extended Deep Space Applications

Extended duration deep space missions as well as permanent space habitats face numerous technical challenges, key among them is energy generation and energy storage. There are considerable monetary and technical barriers to the generation of power in space. Therefore, it is important to store and be able to access power in an efficient and safe manner over a large number of cycles. Energy storage and in particular, batteries, are vital to the operation of next-generation extraterrestrial shuttles, rovers, habitats and extravehicular activity (EVA) space suits. The performance metrics for extended duration space missions are at least 2 times greater than those set for terrestrial applications such as electric automobiles. Furthermore, safety is essential for operation of space missions particularly involving astronauts such as shuttles, habitats and EVA space suits. Preliminary systems level analysis has indicated that there are five key properties which must be optimized for successful implementation of battery systems. Those five key criteria are: safety, energy density, power, packaging design and scalability. Current state-of-the-art (SOA) lithium-ion batteries can meet or exceed the requirements for certain space applications in the areas of power and scalability, yet are insufficient in the key performance criteria of energy, safety and packaging design. The SABERS concept proposes a battery that meets all five key performance criteria through development of a solid-state architecture battery utilizing high capacity sulfur-selenium cathode and lithium metal anode. The combination of sulfur and selenium offers a balanced energy-to-power density ratio, which can be tailored to the specific application by altering the stoichiometric ratios of sulfur to selenium. This hybrid cathode will be developed by implementing NASA patented holey graphene technology as a highly conductive, ultra-lightweight electrode scaffold. A solid-state electrolyte will be used as a safe, non-flammable replacement to the highly flammable liquid organic electrolytes currently used in SOA lithium-ion batteries. This solid-state lithium-sulfur/selenium cell will be designed into a serial stacking configuration to enable dense packaging of the battery cells. The serial stacking configuration is termed a bipolar stack, which has the advantages of reducing overall cell weight, simplifying the interfaced connections for the cell, and minimizing the cooling requirements for the cell. Lastly, optimization of battery components will occur through a robust and rigorous combination of various computational modeling techniques covering multiple length scales. The expected result will be a fully solid-state battery with operational temperatures up to 150 °C which provides the required energy density, discharge rates, and inherent safety to meet the strict space mission performance criteria. In particular, the wide operational temperature window is required for the large temperature ranges which are experienced across a broad range of potential space missions. This presentation will show initial results that demonstrate the SABERS team has developed a composite carbon-sulfur cathode which exceeds 1100 Wh/kg at a discharge rate of 0.4C, and 804 Wh/kg at a discharge rate of 1C. Additionally, this presentation will show the SABERS team multiscale computational modeling approach and has produced a novel particle dynamics method called Solid Electrolyte Sphere Approximation Model (SESAM). SESAM is on the 1-10 µm scale and provides electromechanical and grain interactions for predictive design guidelines for the experimental team to follow.

Urban Air Mobility (UAM) Vehicles↗

Discrete models of fluids: spatial averaging, closure and model reduction

We consider semidiscrete ODE models of single-phase fluids and two-fluid mixtures. In the presence of multiple fine-scale heterogeneities, the size of these ODE systems can be very large. Spatial averaging is then a useful tool for reducing computational complexity of the problem. The averages satisfy exact balance equations of mass, momentum, and energy. These equations do not form a satisfactory continuum model because evaluation of stress and heat flux requires solving the underlying ODEs. To produce continuum equations that can be simulated without resolving microscale dynamics, we recently proposed a closure method based on the use of regularized deconvolution. Here we continue the investigation of deconvolution closure with the long term objective of developing consistent computational upscaling for multiphase particle methods. The structure of the fine-scale particle solvers is reminiscent of molecular dynamics. For this reason we use nonlinear averaging introduced for atomistic systems by Noll, Hardy, and Murdoch-Bedeaux. We also consider a simpler linear averaging originally developed in large eddy simulation of turbulence. We present several simple but representative examples of spatially averaged ODEs, where the closure error can be analyzed. Based on this analysis we suggest a general strategy for reducing the relative error of approximate closure. For problems with periodic highly oscillatory material parameters we propose a spectral boosting technique that augments the standard deconvolution and helps to correctly account for dispersion effects. We also conduct several numerical experiments, one of which is a complete mesoscale simulation of a stratified two-fluid flow in a channel. In this simulation, the operation count per coarse time step scales sublinearly with the number of particles.

Multiscale modeling, discrete models, fluid flow↗

Fast Plasma Investigation for MMS: Simulation of the Burst Triggering System

The Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. To meet these requirements, the Fast Plasma Instrument (FPI) consists of eight (8) identical half top-hat electron sensors and eight (8) identical ion sensors and an Instrument Data Processing Unit (IDPU). The sensors (electron or ion) are grouped into pairs whose 6 degree x 180 degree fields-of-view (FOV) are set 90 degrees apart. Each sensor is equipped with electrostatic aperture steering to allow the sensor to scan a 45 degree x 180 degree fan about the its nominal viewing (0 deflection) direction. Each pair of sensors, known as the Dual Electron Spectrometer (DES) and the Dual Ion Spectrometer (DIS), occupies a quadrant on the MMS spacecraft and the combination of the eight electron/ion sensors, employing aperture steering, image the full-sky every 30-ms (electrons) and 150-ms (ions), respectively. To probe the diffusion regions of reconnection, the highest temporal/spatial resolution mode of FPI results in the DES complement of a given spacecraft generating 6.5-Mb (raised dot) per second of electron data while the DIS generates 1.1-Mb (raised dot) per second of ion data yielding an FPI total data rate of 6.6-Mb (raised dot) per second. The FPI electron/ion data is collected by the IDPU then transmitted to the Central Data Instrument Processor (CIDP) on the spacecraft for science interest ranking. Only data sequences that contain the greatest amount of temporal/spatial structure will be intelligently down-linked by the spacecraft. This requires a data ranking process known as the burst trigger system. The burst trigger system uses pseudo physical quantities to approximate the local plasma environments. As each pseudo quantity will have a different value, a set of two scaling factors is employed for each pseudo term. These pseudo quantities are then combined at the instrument, spacecraft, and observatory level leading to a final ranking of data based on expected scientific interest. Here, we present simulations of the fixed point burst trigger system for the FPI. A variety of data sets based on previous mission data as well as analytical formulations are tested. Comparisons of floating point calculations versus the fixed point hardware simulation are shown. Analysis of the potential sources of error from overflows, quantization, etc. are examined and mitigation methods are presented. Finally a series of calibration curves are presented, showing the expected error in pseudo quantities based solely on the scale parameters chosen and the expected data range. We conclude with a presentation of the current base-lined FPI burst trigger approach.

Barrie, A. C.↗

Development of neural network force fields for corrosion studies

To fully understand the chemistry and physics of corrosion, novel methods of simulation must be developed. One approach is designing machine learning (ML) algorithms integrated with density functional theory to develop adaptive force fields to gain insight into corrosion behavior namely at the surface of metal oxides. Current methods of modeling corrosion are slow due to the computational cost of resolving both reaction mechanics and mass transport processes. Machine learning methods can be implemented to obtain structure-activity relationships at both the molecular and bulk scale while still retaining the accuracy of density functional theory (DFT) and significantly decreasing the time needed for simulations of complex chemical processes in the various environments of corrosion. Multiscale models are needed for corrosion studies to fully understand its processes not only at the atomic length scale (chemical bonding, energies, and forces), but also at the nano and meso length scales (solid-state physics and material science processes). Current methods of study include DFT, molecular dynamics, and Monte Carlo. The limitation of DFT is that only a small number of atoms or molecules can be simulated at that level of theory. Density functional theory is used to study the electronic structure of atoms and molecules, and calculate the force component of each atom. However, these calculations are limited to about 1000 atoms. Custom periodic boundary conditions (PBC) can be used to describe the various environments and defects that affect the atomic forces to produce a large data set from which a training set can be derived. Machine learning can be utilized to overcome the barrier of modeling macroscopic and multi-scale processes from ab initio calculations through the development of adaptive force fields. Local environments determine the atomic forces of a given system, therefore adaptive force fields must be created to produce reliable quantum mechanical calculations. This can be achieved by developing a learning algorithm that uses the mapped atomic forces or fingerprint as an input to produce energies and magnetic moments as output. A systematic approach was used to begin to build a data set in order to accurately describe the atomic forces in various environments. In Figure 4 below, a simple PBC cell of Fe{sub 2}O{sub 3} was first optimized. A surface optimization was performed next, followed by a hydroxylated surface optimization. Once this calculation has converged, the adsorption of halide species to the hydroxylated surface will be investigated. TensorFlow is an open source platform for machine learning developed by Google. Using a high level application program interface (API) such as Keras allows for building and training ML models easily in a number of different environments and languages. For this project, a neural network was developed within Anaconda in Python. Future Work: Further development of reference data set; Refining neural network and learning algorithm; Fingerprinting atomic environment to enable mapping of atomic force components; Choosing appropriate training set from reference data; Learning from training set and enabling non-linear mapping of training set fingerprints and the atomic forces; Estimation of uncertainty to identify ranges of outside applicability; Testing and analysis of molecular dynamic simulations.

36 MATERIALS SCIENCE↗

Atomistic hybrid DSMC/NEMD method for nonequilibrium multiscale simulations

A multiscale hybrid method for coupling the direct simulation Monte Carlo (DSMC) method to the nonequilibrium molecular dynamics (NEMD) method is introduced. The method addresses Knudsen layer type gas flows within a few mean free paths of an interface or about an object with dimensions of the order of a few mean free paths. It employs the NEMD method to resolve nanoscale phenomena closest to the interface along with coupled DSMC simulation of the remainder of the Knudsen layer. The hybrid DSMC/NEMD method is a particle based algorithm without a buffer zone. It incorporates a new, modified generalized soft sphere (MGSS) molecular collision model to improve the poor computational efficiency of the traditional generalized soft sphere GSS model and to achieve DSMC compatibility with Lennard-Jones NEMD molecular interactions. An equilibrium gas, a Fourier thermal flow, and an oscillatory Couette flow, are simulated to validate the method. The method shows good agreement with Maxwell-Boltzmann theory for the equilibrium system, Chapman-Enskog theory for Fourier flow, and pure DSMC simulations for oscillatory Couette flow. Speedup in CPU time of the hybrid solver is benchmarked against a pure NEMD solver baseline for different system sizes and solver domain partitions. Finally, the hybrid method is applied to investigate interaction of argon gas with solid surface molecules in a parametric study of the influence of wetting effects and solid molecular mass on energy transfer and thermal accommodation coefficients. It is determined that wetting effect strength and solid molecular mass have a significant impact on the energy transfer between gas and solid phases and thermal accommodation coefficient.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Disruption of histone acetylation homeostasis reveals multilayered chromatin regulation for transcriptional resiliency

Background Epigenetic modifications, nucleosome occupancy, and three-dimensional chromatin architecture collectively create a multi-layered, highly interactive regulatory system for controlling genomic functionality. Dysregulation of epigenetic processes leads to a plethora of abnormalities including disease states. Therapies focused on epigenetic modulation can alter gene expression to correct dysfunction, though the perpetuation of these states and the relationships among chromatin regulatory layers is not well understood. Results Here, we investigated global and local chromatin structural and functional responses after acute histone deacetylase inhibitor treatment (suberoylanilide hydroxamic acid) in lung cancer cells across time. Treatment substantially increased global histone acetylation resulting in a pervasive but not distinctive signature. The spread of acetylation did not significantly impact global chromatin accessibility, and nucleosome remodeling largely occurred at finer scales in functionally relevant genomic regions. Indeed, both H 3 K 4 trimethylation, a mark of active transcription, and gene expression changes were altered in a controlled locus-specific manner, suggesting aberrant acetylation indirectly leads to balanced and bidirectional gene expression profiles from tighter regulation of other chromatin features. HDACi treatment induced (13%) genomic rearrangement in chromatin compartmentalization and moderate weakening of topologically associating domains. Conclusions Continuous wavelet analysis of these features demonstrates that scale-dependent, locus-specific factors influence the relationship between chromatin architecture and functional output, suggesting that regulation of transcription and nucleosome remodeling is not entirely (nor linearly) dependent upon large scale compartment exchange. Structural and functional responses are most pronounced early after treatment with partial persistence of differential local chromatin features and expression later in time; this highlights the plasticity of chromatin regulation, which may have implications for the efficacy of epigenetic treatments. These results demonstrate the effectiveness of multi-layered regulation of transcription: in resilient systems, disruption of one chromatin feature does not distort the regulation of other features in supporting a transcriptional program that allows for survival.

59 BASIC BIOLOGICAL SCIENCES↗

Fostering a Guiding Multiscale Model for the Development of Advanced MgB 2 Hydrogen Storage Materials (Final Technical Report)

Project Goal and Objective. The demand for energy and for an upgraded energy infrastructure has steadily grown, as have the needs for energy independence and alternatives to our reliance on petroleum. Hydrogen is considered the most viable fuels for wide-scale implementation in the near future as it is less-polluting, non-toxic, and has more stored energy than petroleum. It is envisioned that hydrogen can eventually become the prime energy carrier, integrating the transportation, grid, and chemical sectors in a way that improves resiliency, diversifies feedstocks, and affords new economic opportunities. A key remaining challenge is the development materials with enhanced gravimetric and volumetric hydrogen storage capacities that offer a higher performance than compressed gas. These materials would eliminate the need for large-scale compression, thereby dramatically reducing the footprint and cost of gas storage. The high gravimetric and volumetric hydrogen capacities of complex hydrides has prompted an intensive investigation of the potential of this class of materials as hydrogen storage media over the past 25 years. Among the many complex hydrides that have been explored, magnesium borohydride, Mg(BH 4 ) 2 , has been found to possess the best combination of practical thermodynamic properties. These include a gravimetric H 2 density of 14.9 wt% H 2 and thermodynamics for the dehydrogenation of Mg(BH 4 ) 2 to MgB 2 (equation 1) (ΔH° = 39 kJ/mol H 2 , ΔS = 112 J/K mol H 2 ) which lie in the narrow window required Mg(BH 4 ) 2 $\Leftrightarrow$ MgB 2 + 4 H 2 (1) for reversibility under moderate pressure and temperature. However, overcoming the extremely slow kinetics of the reversible release of hydrogen by this material in the solid state is a daunting challenge. At temperatures greater than 400 °C, the borohydride releases up to 14 wt% hydrogen giving MgB 2 . We discovered that the direct re-hydrogenation of MgB 2 to Mg(BH 4 ) 2 can be accomplished under 950 bar H 2 at 400 °C. While this demonstrated that complete reversibility can be achieved, the conditions employed are far too extreme for commercial hydrogen storage applications. More recently, we found through US DOE funded research projects (EERE HyMARC and HySCOR), that hydrogen cycling, can be accomplish at much milder conditions upon modification of the borohydride or boride. Guided by these discoveries these discoveries, the objective of this research project was to obtain key information that will enable the development of a model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 . The ultimate goal of our efforts is to attain a model of this transformation that can be utilized to accelerate development further advanced materials. This project directly follows on discoveries that were made over the course of a US DOE, EERE HyMARC project that was focused on improvement of the hydrogen cycling kinetics of modified MgB 2 . We found that that mechanical milling with graphene results the desired, pronounced kinetic enhancement. The dramatic lowering of the conditions required for the hydrogenation of MgB 2 is a significant step towards overcoming its chemical inertness allowing its development as a practical onboard hydrogen storage material. However, the exact nature of the modification(s) of MgB 2 that is responsible for its activation towards hydrogenation is completely unknown. This situation is not unique, as efforts to develop hydrogen storage materials typically have a narrow focus rather than a comprehensive approach that takes atomic level bonding and structure; molecular dynamics; long range, nano- and mesoscale-structure and their interconnection all into account. The goal of this project was the development of a comprehensive, multi-scale computational model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 that can be utilized for development of higher performance versions of the modified material. Development of the model requires determination of: 1) the bulk, nano-scale, and meso-scale structural changes occurring at elevated pressure following mechano-chemical modification of MgB 2 ; 2) the reaction pathway of the reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 ; 3) the effect of elevated pressure and mechano-chemical modification on the chemical reaction pathways; 4) the interactions at solid-gas interfaces; and particle surfaces; and 5) the kinetics and thermodynamic parameters associated with each step of the hydrogenation reaction pathway. This investigation required advanced techniques as preliminary, standard XRD, 11 B NMR, and FTIR analysis showed no signs of material modification. In order to gain this level of understanding of modified MgB 2 , required the teaming of a diverse group of experts and state-of-the art experimental capabilities at the University of Hawaii at Manoa (UHM) and collaborating National Laboratories: Craig Jensen , Department of Chemistry (PI and Project Director), solid state, solution, and high pressure NMR spectroscopy; solid-state synthesis; and high pressure hydrogenation (collaboration with SNL); Godwin Severa , Hawaii Natural Energy Institute (co-PI) calorimetry; infrared and Raman spectroscopy (collaboration with NREL); Dera , high pressure X-ray diffraction including in situ experiments (collaboration with ANL); Hope Ishii , Hawaii Institute of Geophysics electron microscopy investigations (collaboration with LBNL); and Joe Brown , Mechanical Engineering , material electronic structure and electric field effects.

08 HYDROGEN↗

Structural Characterization of the Platinum Nanoparticle Hydrogen-Evolving Catalyst Assembled on Photosystem I by Light-Driven Chemistry

Directed assembly of abiotic catalysts onto biological redox protein frameworks is of interest as an approach for the synthesis of biohybrid catalysts that combine features of both synthetic and biological materials. In this report, we provide a multiscale characterization of the platinum nanoparticle (NP) hydrogen-evolving catalysts that are assembled by light-driven reductive precipitation of platinum from an aqueous salt solution onto the photosystem I protein (PSI), isolated from cyanobacteria as trimeric PSI. The resulting PSI-NP assemblies were analyzed using a combination of X-ray energy-dispersive spectroscopy (XEDS), high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM), small-angle X-ray scattering (SAXS), and high-energy X-ray scattering with atomic pair distribution function (PDF) analyses. The results show that the PSI-supported NPs are approximately 1.8 nm diameter disk-shaped particles that assemble at discrete sites with 145 Å separation. This separation is too large to be consistent with NP nucleation and growth at a site adjacent to the F B cofactor site. Instead, we suggest a mechanism for NP growth at hydrophobic sites on the PSI stromal surface. The NPs photoreductively assembled on the PSI stromal surface are found to be analogous to the nanostructures produced by successive cycles of atomic layer deposition (ALD) of platinum onto 40 nm porous anodic alumina oxide supports, although the mechanisms for nucleation appear to differ. In conclusion, this work establishes a foundation for the investigation of the reductive assembly of abiotic metal catalysts at sites connected to photochemically reducing equivalent production in PSI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multicriteria cost–benefit assessment of tannery production: The need for breakthrough process alternatives beyond conventional technology optimization

The worldwide use of chromium-based processes in tanneries generates increased concerns about their related environmental burdens. Cleaner production alternatives for leather production are being proposed, based on the optimization of specific aspects or criteria, for instance, reducing demand for specific materials and energy, or reducing local toxicological emissions. While improvement on individual characteristics of the process is certainly to be favored, a more comprehensive evaluation of alternatives is also needed to prevent the risk of shifting the burden to increase global load while addressing one specific critical factor of production. This work aims to discuss the importance of a multicriteria, multiscale approach to address cleaner production strategy costs and benefits. For this, materials balance, an economic approach, and emergy (with an “m”) accounting methods are applied to selected unhairing/liming, pickling/tanning and wastewater treatment steps in a tannery process, which was chosen as a case study. Results show that the assessed recycling cleaner production strategies assessed allow the manufacturer to reduce by one half the amount of water used and the demand for chemicals up to 4% with respect to the business-as-usual process, at the expense of increasing electricity demand by 10%. Economic cost-to-benefit ratio was 25$ benefits per 1$ invested, as well as an emergy-based cost-to-benefit of 33Em$ per 1Em$ invested, of course these improvements were limited to the three investigated process steps. The improvement in cost/benefit ratios indicates that converting scenario #0 into #1 is favorable under economic and emergy views. However, when the two scenarios are investigated from the point of view of the imbalance in local and renewable resource use versus imported and nonrenewable use, the emergy method shows a small overall increase in renewability (from 3.51% to 3.85%), a low, but expected, emergy yield ratio equal to 1, and a high environmental loading ratio (24.95 and 27.47). While the environmental cost–benefit ratio shows that recycling is a favorable option, the emergy performance indicators highlight that the efficiency of recycling is still insufficient and improvements in the tanning processes are needed to ensure renewability and sustainability. A number of process chemicals were involved in the investigated tannery operations, which required emergy evaluations. As a side result of this study, the Unit Emergy Values (UEVs) of SO{sub 2}, H{sub 2}SO{sub 4} Na{sub 2}SO{sub 4}, HCL, Na{sub 2}S, NaOH, CaO, Ca(OH){sub 2}, Cr{sub 2}O{sub 3}, MnSO{sub 4}, and Al(OH){sub 3}, were also calculated thus adding to the emergy database about chemicals. - Highlights: • Cleaner production strategies for tannery processes are presented and evaluated. • Local and global scales are considered under economical and biophysical approaches. • A multicriteria approach should be considered for decision making. • Recycling strategies have better indicators than traditional processes. • Emergy integrates energy and monetary indicators for more comprehensive assessment.

54 ENVIRONMENTAL SCIENCES↗

WE-AB-202-11: Radiobiological Modeling of Tumor Response During Radiotherapy Based On Pre-Treatment Dynamic PET Imaging Data

Purpose: To evaluate the ability of a multiscale radiobiological model of tumor response to predict mid-treatment hypoxia images, based on pretreatment imaging of perfusion and hypoxia with [18-F]FMISO dynamic PET and glucose metabolism with [18-F]FDG PET. Methods: A mechanistic tumor control probability (TCP) radiobiological model describing the interplay between tumor cell proliferation and hypoxia (Jeong et al., PMB 2013) was extended to account for intra-tumor nutrient heterogeneity, dynamic cell migration due to nutrient gradients, and stromal cells. This extended model was tested on 10 head and neck cancer patients treated with chemoradiotherapy, randomly drawn from a larger MSKCC protocol involving baseline and mid-therapy dynamic PET scans. For each voxel, initial fractions of proliferative and hypoxic tumor cells were obtained by finding an approximate solution to a system of linear equations relating cell fractions to voxel-level FDG uptake, perfusion (FMISO K{sub 1}) and hypoxia (FMISO k{sub 3}). The TCP model then predicted their evolution over time up until the mid treatment scan. Finally, the linear model was reapplied to predict each lesion’s median hypoxia level (k{sub 3}[med,sim]) which in turn was compared to the FMISO k{sub 3}[med] measured at mid-therapy. Results: The average k3[med] of the tumors in pre-treatment scans was 0.0035 min{sup −1}, with an inter-tumor standard deviation of σ[pre]=0.0034 min{sup −1}. The initial simulated k{sub 3}[med,sim] of each tumor agreed with the corresponding measurements within 0.1σ[pre]. In 7 out of 10 lesions, the mid-treatment k{sub 3}[med,sim] prediction agreed with the data within 0.3σ[pre]. The remaining cases corresponded to the most extreme relative changes in k{sub 3}[med]. Conclusion: This work presents a method to personalize the prediction of a TCP model using pre-treatment kinetic imaging data, and validates the modeling of radiotherapy response by predicting changes in median hypoxia values during treatment. Variations from predicted response may be a useful biomarker, which should be further explored. Partially supported by NIH grant #1 R01 CA157770-01A1 and a grant from Varian Corporation.

60 APPLIED LIFE SCIENCES↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗