Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

System Calibration Including Time Delay Estimation for GNSS/INS-Assisted Pushbroom Scanners Onboard UAV Platforms

Unmanned aerial vehicles (UAVs ) equipped with imaging sensors and integrated global navigation satellite system/inertial navigation system (GNSS/INS ) units are used for numerous applications. Deriving reliable 3D coordinates from such UAVs is contingent on accurate geometric calibration, which encompasses the estimation of mounting parameters and synchronization errors. Through a rigorous impact analysis of such systematic errors, this article proposes a direct approach for spatial and temporal calibration (estimating system parameters through a bundle adjustment procedure) of a GNSS/INS -assisted pushbroom scanner onboard a UAV platform. The calibration results show that the horizontal and vertical accuracies are within the ground sampling distance of the sensor. Unlike for frame camera systems, this article also shows that the indirect approach is not a feasible solution for pushbroom scanners due to their limited ability for decoupling system parameters. This finding provides further support that the direct approach is recommended for spatial and temporal calibration of UAV pushbroom scanner systems.

47 OTHER INSTRUMENTATION↗

Hadron Monitor Calibration System for NuMI

NuMI (Neutrinos at Main Injector) beamline at Fermi National Accelerator Laboratory provides neutrinos to various neutrino experiments. The hadron monitor consisting of a 5 by 5 array of ionization chambers is part of the diagnostics for the beamline. In order to calibrate the hadron monitor, a gamma source is needed. We present the status and progress of the development of the calibration system for the hadron monitor. The system based on Raspberry Pi controlled CNC system, motors, and position sensors would allow us to place the gamma source precisely to calibrate the signal gain of individual pixels. The ultimate outcome of the study is a prototype of the calibration system.

43 PARTICLE ACCELERATORS↗

GoldSim E-Area Low-Level Waste Facility Aquifer Zone Model Calibration Methodology

This report documents the development and calibration of the E-Area Low-Level Waste Facility (ELLWF) Gold Sim aquifer model. It provides a methodology on how a Gold Sim aquifer model can be calibrated to specific PORFLOW-based aquifer predictions. The calibration activity presented within this report focuses on the Slit Trench #06 (ST06) location that resides within the center set of Slit Trenches. This Gold Sim-based aquifer model is a generic model capable of being calibrated to any of the other trench locations within E-Area. In addition, subsequent activities (beyond the scope of this effort) will couple this GoldSim-based aquifer model to various GoldSim-based trench models, with the intent of performing stochastic analyses that couple all pertinent fate and transport processes from the ground surface up to the 100-m point of assessment (POA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Re-calibration of PBX9501 SURF model

PBX 9501 is a plastic bonded explosive composed of 95 wt % HMX and a binder; see [Gibbs and Popolato, 1980, pp. 109–119]. SURF is a reactive burn model for shock initiation and propagation of detonation waves. It has previously been calibrated for PBX 9501. Here the SURF model is recalibrated for PBX 9501; specifically, lot 730-010 at ρ = 1.837 g/cc 3 . The new calibration uses the Davis reactants and products EOS calibrated for the AWSD model [Aslam et al., 2020]. The burn rate in the shock initiation regime is fit to the Pop plot from 5 embedded gauge shock-to-detonation transition (SDT) experiments from [Gustavsen et al., 1999, see fig 12 and table 5]. In the propagation regime, the burn rate is fit to curvature effect data (detonation speed as function of front curvature); see [Aslam, 2007]. Also the burn parameters are adjusted to fit the gap-stick experiment [Hill et al., 2018]. Simulating the detonation wave speed in this experiment requires a model that is accurate for initiation with complex shock loading; in particular, a pressure decreasing gradient behind a curved lead shock. This is more difficult than calibrating to the standard SDT experiments which are 1-D and driven by a sustained shock. Simulations of the gap-stick experiment for PBX 9501 with the SURF model will be discussed in a subsequent report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECAL Calibration and Energy Resolution for a 10TeV Detector Geometry

In the pursuit of a muon collider operating at ~10 TeV center-of-mass-energy, designing a highly accurate and sensitive detector is crucial. Calorimetry plays a key part in any detector setup, as we rely on our calorimeters for energy reconstruction and particle identification. Therefore, an effective calorimeter must be extremely well-calibrated and achieve excellent resolution. This poster will report on efforts to achieve a comprehensive energy calibration of the electromagnetic calorimeter (ECAL) for our 10 TeV detector design. This calibration is necessary in order to achieve desired energy resolution for reconstructed photons across a wide range of energies (0-1TeV). We report on the challenges introduced by the new location of the solenoid in our latest 10 TeV detector design, the necessity of a calibration strategy that is both energy-dependent and angularly dependent, and the resulting effects on photon energy resolution.

Powers, Rose↗

CACTI Radar b1 Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) user facility deployed a large number of instruments to a region nearby the Sierra de Córdobas mountains in Argentina as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign (1). During this campaign, four radars were installed at a site outside of Villa Yacanto as shown in Figure 1. As part of a post-campaign effort to improve the usability of these data, a significant activity was undertaken towards the calibration, correction, and improvement of the data quality of these radar datastreams. This process in ARM nomenclature is referred to as generating a “b1” datastream. While these “b1” standards may imply different corrections or standards for various ARM instruments, for radars it refers to a datastream that has been calibrated (and cross-calibrated), including a serious effort to deliver the highest-quality (well-characterized) data possible. This report details (i) the status/quality of the original “a1” (raw) data, (ii) the corrections and calibrations that are applied to generate these b1 datastreams, (iii) the details of the applied algorithms and how radar offset/calibration numbers were determined for the eventual corrections, and (iv) the new and flexible plug-in-based processing system designed during CACTI for radar b1 activities (current, future) that interfaces with ARM’s Data Integrator (ADI) and high-performance computing (HPC) system.

47 OTHER INSTRUMENTATION↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams

Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methodology to Calibrate Fragility Curves Using Limited Real-World Data

With increasing human dependence on electricity and increasing energy demand, electrical infrastructure has emerged to be one of the most critical services. This is one of the main reasons for making the power grid more resilient to extreme events during which uninterrupted power supply is crucial in keeping the consequences of the extreme event limited. The first step towards making the overall power grid more resilient is to evaluate the probabilities of failure for all assets at risk from the excitation caused by extreme events. Thus, this paper presents the methodology to calibrate fragility curves. The strength of the proposed approach is its ability to calibrate the fragility curves utilizing limited data, which is the most common constraint in carrying out such analyses. This paper describes the calibration of transmission tower fragility curves for Puerto Rico utilizing only damage reports for hurricane Maria. That, combined with Puerto Rico's wind modeling & geographic information system, this study also calibrates fragility curves for transmission towers made with four different construction materials.

Bereta dos Reis, Fernando↗

GPS Measurements of Precipitable Water Vapor Can Improve Survey Calibration: A Demonstration from KPNO and the Mayall z -band Legacy Survey

Dual-band Global Positioning Satellite (GPS) measurements of precipitable water vapor (PWV) at the Kitt Peak National Observatory predict the overall per-image sensitivity of the Mayall z-band Legacy Survey (MzLS). The per-image variation in the brightness of individual stars is strongly correlated with the measured PWV and the color of the star. Synthetic stellar spectra through TAPAS transmission models successfully predict the observed PWV-induced photometric variation. We find that PWV absorption can be well approximated by a linear relationship with (airmass × PWV) 0.6 and present an update on the traditional treatment in the literature. The MzLS zero-point sensitivity in electrons s –1 varies with a normalized-mean absolute deviation of 61 mmag. PWV variation accounts 23 mmag of this zero-point variation. The MzLS per-image absolute sensitivity decreases by 40 mmag per effective mm of PWV. The overall gray offset portion of this variation is corrected by the calibration to a reference catalog. But the relative calibration error between blue (r – z < 0.5 mag) versus red (1.2 mag < r – z) stars increases by 0.3–2 mmag per effective mm of PWV. We argue that GPS systems provide more precise PWV measurements than using differential measurements of stars of different colors and recommend that observatories install dual-band GPS as a low-maintenance, low-cost, auxiliary calibration system. We extend our results of the need for well-calibrated PWV measurements by presenting the calculations of the PWV photometric impact on three science cases of interest: stellar photometry, supernova cosmology, and quasar identification and variability.

79 ASTRONOMY AND ASTROPHYSICS↗

PROTOCALC, a W -band Polarized Calibrator for Cosmic Microwave Background Telescopes: Application to Simons Observatory and CLASS

Current- and next-generation cosmic microwave background (CMB) experiments will measure polarization anisotropies with unprecedented sensitivities. The need for high precision in these measurements underscores the importance of gaining a comprehensive understanding of instrument properties, with a particular emphasis on the study of the beam properties, and especially their polarization characteristics and the measurement of the polarization angle. In this context, a major challenge lies in the scarcity of millimeter polarized astrophysical sources with sufficient brightness and calibration knowledge to meet the stringent accuracy requirements of future CMB missions. This led to the development of a drone-borne calibration source designed for the frequency band centered on approximately 90 GHz, matching a commonly used channel in ground-based CMB measurements. The Prototype Calibrator for Cosmology, PROTOCALC, has undergone thorough in-lab testing, and its properties have been subsequently modeled through simulation software integrated into the standard Simons Observatory analysis pipeline. Moreover, the PROTOCALC system has been tested in the field, having been deployed twice on calibration campaigns with CMB telescopes in the Atacama Desert. The data collected constrain the roll angle of the source with a statistical accuracy of 0$^°_•$045.

79 ASTRONOMY AND ASTROPHYSICS↗

Binning is Sinning (Supernova Version): The Impact of Self-calibration in Cosmological Analyses with Type Ia Supernovae

Recent cosmological analyses (e.g., JLA, Pantheon) of Type Ia supernovae (SNe Ia) have propagated systematic uncertainties into a covariance matrix and either binned or smoothed the systematic uncertainty vectors in redshift space. We demonstrate that systematic error budgets of these analyses can be improved by a factor of ~ 1.5 × with the use of unbinned and unsmoothed covariance matrices. To understand this, we employ a separate approach that simultaneously fits for cosmological parameters and additional self-calibrating scale parameters that constrain the size of each systematic. We show that the covariance-matrix approach and scale-parameter approach indeed yield equivalent results, implying that in both cases the data can self-calibrate certain systematic uncertainties, but that this ability is hindered when information is binned or smoothed in redshift space. We review the top systematic uncertainties in current analyses and find that the reduction of systematic uncertainties in the unbinned case depends on whether a systematic is solely degenerate with the cosmological model in redshift space or whether it can be described by additional correlations between supernova properties and luminosity. Furthermore, we show that the power of self-calibration increases with the size of the data set, which presents a tremendous opportunity for upcoming analyses of photometrically classified samples, like those of Legacy Survey of Space and Time (LSST) and the Nancy Grace Roman Telescope (NGRST). However, to take advantage of self-calibration in large, photometrically classified samples, we must first address the issue that binning is required in currently used photometric analysis methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Wet-radome attenuation in ARM cloud radars and its utilization in radar calibration using disdrometer measurements

Abstract. A relative calibration technique has been developed for the US Department of Energy's (DOE's) Atmospheric Radiation Measurement (ARM) user facility Ka-band ARM Zenith Radars (KAZRs). This method uses the signal attenuation caused by water on the radome to estimate reflectivity factor (Ze) offsets. The wet-radome attenuation (WRA) is assumed to follow a log-linear relationship with rainfall rate during light and moderate rain, as measured by a collocated surface disdrometer. The technique has an uncertainty of approximately 3 dB, due to factors such as disdrometer measurement error, rain variability between radar and disdrometer sample volumes, and the fitting function's uncertainty for the WRA behavior. A practical advantage of this WRA-based approach to shorter-wavelength radar monitoring is that, while it requires a reference disdrometer, it proves feasible for a wider range of collocated disdrometer measurements compared to traditional direct disdrometer comparison at the onset of light rain. This technique thus offers a cost-effective monitoring tool for remote or long-term radar deployments. This calibration technique was applied during the ARM Tracking Aerosol Convection Interactions Experiment (TRACER) from October 2021 through September 2022. The estimated Ze offsets were compared against traditional radar calibration and monitoring methods using available datasets from this campaign. Results show that the WRA-based offsets align closely with mean offsets found between cloud radars and from direct disdrometer comparison near the onset of rain, while also reflecting similar offset and campaign-long trends when compared to collocated, independently calibrated radar wind profilers. Nevertheless, overall, the KAZR Ze offsets estimated during TRACER remained stable at approximately 2 dB lower than the disdrometer estimates from the campaign start until the end of June 2022; afterward, the offsets increased to around 7 dB by the campaign's end. This increase is linked to a drop of about 1 dB in transmitter power toward the end of the project.

54 ENVIRONMENTAL SCIENCES↗

Using a surrogate-assisted Bayesian framework to calibrate the runoff-generation scheme in the Energy Exascale Earth System Model (E3SM) v1

Abstract. Runoff is a critical component of the terrestrial water cycle, and Earth system models (ESMs) are essential tools to study its spatiotemporal variability. Runoff schemes in ESMs typically include many parameters so that model calibration is necessary to improve the accuracy of simulated runoff. However, runoff calibration at a global scale is challenging because of the high computational cost and the lack of reliable observational datasets. In this study, we calibrated 11 runoff relevant parameters in the Energy Exascale Earth System Model (E3SM) Land Model (ELM) using a surrogate-assisted Bayesian framework. First, the polynomial chaos expansion machinery with Bayesian compressed sensing is used to construct computationally inexpensive surrogate models for ELM-simulated runoff at 0.5∘ × 0.5∘ for 1991–2010. The error metric between the ELM simulations and the benchmark data is selected to construct the surrogates, which facilitates efficient calibration and avoids the more conventional, but challenging, construction of high-dimensional surrogates for the ELM simulated runoff. Second, the Sobol' index sensitivity analysis is performed using the surrogate models to identify the most sensitive parameters, and our results show that, in most regions, ELM-simulated runoff is strongly sensitive to 3 of the 11 uncertain parameters. Third, a Bayesian method is used to infer the optimal values of the most sensitive parameters using an observation-based global runoff dataset as the benchmark. Our results show that model performance is significantly improved with the inferred parameter values. Although the parametric uncertainty of simulated runoff is reduced after the parameter inference, it remains comparable to the multimodel ensemble uncertainty represented by the global hydrological models in ISMIP2a. Additionally, the annual global runoff trend during the simulation period is not well constrained by the inferred parameter values, suggesting the importance of including parametric uncertainty in future runoff projections.

58 GEOSCIENCES↗

DMTN-222: Calibration Generation, Verification, Acceptance, and Certification

This technote defines the best practices to be used for calibration generation, the verification that that calibration meets requirements, and when deciding if the calibration should be accepted for use in processing at both the summit and USDF. Other aspects of calibration product management, including the contents of the appropriate "defaults" collection, are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Mariner Mars 1971 scan platform pointing calibration

A technique was devised for the Mariner Mars 1971 mission wherein both ground and in-flight calibrations were performed. A more analytical approach was used for ground calibration, and in-flight calibration was performed using narrow-angle television pictures of stars. The Mariner Mars 1971 calibration technique and results are summarized.

Pace, G. D.↗