CACTI Radar b1 Processing: Corrections, Calibrations, and Processing Report

Abstract

The U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) user facility deployed a large number of instruments to a region nearby the Sierra de Córdobas mountains in Argentina as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign (1). During this campaign, four radars were installed at a site outside of Villa Yacanto as shown in Figure 1. As part of a post-campaign effort to improve the usability of these data, a significant activity was undertaken towards the calibration, correction, and improvement of the data quality of these radar datastreams. This process in ARM nomenclature is referred to as generating a “b1” datastream. While these “b1” standards may imply different corrections or standards for various ARM instruments, for radars it refers to a datastream that has been calibrated (and cross-calibrated), including a serious effort to deliver the highest-quality (well-characterized) data possible. This report details (i) the status/quality of the original “a1” (raw) data, (ii) the corrections and calibrations that are applied to generate these b1 datastreams, (iii) the details of the applied algorithms and how radar offset/calibration numbers were determined for the eventual corrections, and (iv) the new and flexible plug-in-based processing system designed during CACTI for radar b1 activities (current, future) that interfaces with ARM’s Data Integrator (ADI) and high-performance computing (HPC) system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hardin, Joseph C., Hunzinger, Alexis, Schuman, Eddie, Matthews, Alyssa, Bharadwaj, Nitin, Varble, A., Johnson, Karen, Giangrande, Scott. 2020-05-01. CACTI Radar b1 Processing: Corrections, Calibrations, and Processing Report. https://doi.org/10.2172/3018467

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗