Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Optical interconnections and networks; Proceedings of the Meeting, The Hague, Netherlands, Mar. 14, 15, 1990

The conference presents papers on interconnections, clock distribution, neural networks, and components and materials. Particular attention is given to a comparison of optical and electrical data interconnections at the board and backplane levels, a wafer-level optical interconnection network layout, an analysis and simulation of photonic switch networks, and the integration of picosecond GaAs photoconductive devices with silicon circuits for optical clocking and interconnects. Consideration is also given to the optical implementation of neural networks, invariance in an optoelectronic implementation of neural networks, and the recording of reversible patterns in polymer lightguides.

Bartelt, Hartmut↗

Adaptation of sleep and circadian rhythms to the Antarctic summer - A question of zeitgeber strength

Adaptation of sleep and circadian rhythms was examined in three temperate zone dwellers arriving in Antarctica during summer. Rectal temperature, wrist activity, and heart rate were monitored continuously, sleep timing and quality noted on awakening, and mood and fatigue rated every 2 h while awake. Sleep was poorer in 2/3 subjects in Antarctica, where all subjects reported more difficulty rising. Sleep occurred at the same clock times in New Zealand and Antarctica, however, the rhythms of temperature, activity, and heart rate underwent a delay of about of 2 h. The subject with the most Antarctic experience had the least difficulty adapting to sleeping during constant daylight. The subject with the most delayed circadian rhythms had the most difficulty. The delay in the circadian system with respect to sleep and clock time is hypothesized to be due to differences in zeitgeber strength and/or zeitgeber exposure between Antarctica and New Zealand.

Gander, Philippa H.↗

About time

Time has historically been a measure of progress of recurrent physical processes. Coordination of future actions, prediction of future events, and assigning order to events are three practical reasons for implementing clocks and signalling mechanisms. In large networks of computers, these needs lead to the problem of synchronizing the clocks throughout the network. Recent methods allow this to be done in large networks with precision around 1 millisecond despite mean message exchange times near 5 milliseconds. These methods are discussed.

Denning, Peter J.↗

A high-performance Hg(+) trapped ion frequency standard

A high-performance frequency standard based on (199)Hg(+) ions confined in a hybrid radio frequency (RF)/dc linear ion trap is demonstrated. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. A 160-mHz-wide atomic resonance line for the 40.5-GHz clock transition is used to steer the output of a 5-mHz crystal oscillator to obtain a stability of 2 x 10(exp -15) for 24,000-second averaging times. Measurements with a 37-mHz line width for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is better than 1 x 10(exp -15) at 10,000-second averaging times.

Prestage, J. D.↗

Method and apparatus for frequency spectrum analysis

A method for frequency spectrum analysis of an unknown signal in real-time is discussed. The method is based upon integration of 1-bit samples of signal voltage amplitude corresponding to sine or cosine phases of a controlled center frequency clock which is changed after each integration interval to sweep the frequency range of interest in steps. Integration of samples during each interval is carried out over a number of cycles of the center frequency clock spanning a number of cycles of an input signal to be analyzed. The invention may be used to detect the frequency of at least two signals simultaneously. By using a reference signal of known frequency and voltage amplitude (added to the two signals for parallel processing in the same way, but in a different channel with a sampling at the known frequency and phases of the reference signal), the absolute voltage amplitude of the other two signals may be determined by squaring the sine and cosine integrals of each channel and summing the squares to obtain relative power measurements in all three channels and, from the known voltage amplitude of the reference signal, obtaining an absolute voltage measurement for the other two signals by multiplying the known voltage of the reference signal with the ratio of the relative power of each of the other two signals to the relative power of the reference signal.

Cole, Steven W.↗

A geodetic laser radar rangefinder with 10(exp -7) resolution

A novel geodetic laser radar rangefinder (GLRR) unit utilizing a pair of synchronized 10-psec streak camera systems was developed for displacement measurements of the earth's plates. In order to achieve minimum computing error and assure extremely high spatial resolution, an optical pulse registration clock was developed and used to register a fiducial mark on the time scale of the system. Conventional optical rangefinders have been limited to a relative resolution of 10(exp -6) even for short distances. The system to be reported on today has the capability of measuring a 50km range with an accuracy of 4mm corresponding to a relative resolution of 10(exp -7). With a gain of greater than 3 x 10(exp 3), the system has the capability of detecting extremely weak signals on the order of photon counting. This combined with temporal gating makes daytime measurements comparable in signal-to-noise ratio to nighttime viewing. This is useful for measuring faint signals returning over a range of several tens of kilometers. The present ranging system was designed to observe the mutual displacement of geodetic plates and was employed to measure the boundary between the Philippine and Asian geodetic plates that pass beneath the Suruga Bay near Hamamatsu City, Japan. The system has been in operation for over 3 years. In addition, the system has the ability of producing and detecting optical ranging pulses of several wavelengths simultaneously, making this a complete multicolor system. The basic GLRR system consists of a frequency stabilizing crystal, optical clock, YAG laser, KDP doubling crystal, DK*P tripling crystal, two matched streak cameras (A and B), a control computer, and an output/input periscope system.

Mizushima, Y.↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗

Millisecond pulsar observation system at CRL

Millisecond pulsars have attracted attention as future reference clocks in place of present atomic clocks. The Communications Research Laboratory (CRL) has been developing an observation system to measure the pulse timing of a millisecond pulsar precisely, and has recently completed the basic part of the task. We observed PSR1937+21 at 1.5GHz band and got a pulse timing with a precision of 16 micro sec/tau by five days of observation.

Hanado, Yuko↗

Ring-array processor distribution topology for optical interconnects

The existing linear and rectangular processor distribution topologies for optical interconnects, although promising in many respects, cannot solve problems such as clock skews, the lack of supporting elements for efficient optical implementation, etc. The use of a ring-array processor distribution topology, however, can overcome these problems. Here, a study of the ring-array topology is conducted with an aim of implementing various fast clock rate, high-performance, compact optical networks for digital electronic multiprocessor computers. Practical design issues are addressed. Some proof-of-principle experimental results are included.

Li, Yao↗

Low-Jitter Digital Rate Multiplier

Jitter in digital rate multiplier reduced by improved method involving use of two slightly different minor clock periods. Original application to divide measured period of spin of spacecraft into large number of equal subintervals, by counting cycles of master oscillator running at high frequency. Method also used to reduce jitter in other situations necessary to generate equal subintervals from synchronizing clock signal of arbitrary period. Particularly valuable in situations where synchronizing signals lost temporarily and where drift in analog circuit unacceptable.

Katz, Richard B.↗

Sidereal-Rate Generator

Innovative circuit derives sidereal seconds from precise 60-Hz source. Sidereal-rate generator puts out sidereal clock signals with error of only about 1.8 seconds per year. Output pulse periods uniform, solar and sidereal outputs available from single source, circuit compatible with normal digital clocks, and circuit driven by readily available reference frequency. Applications in stellar tracking, celestial navigation, and celestial photography.

Franke, John M.↗

General-Purpose Driver For Arrays Of Photodetectors

Electronic system containing both digital and analog circuits supplies clock waveforms at frequencies up to 12 MHz and/or bias voltages in 16 output channels. Designed to provide low-noise driving signals for any of variety of arrays of photodetectors. Clock waveform and/or bias in each channel adjusted independently of others to suit requirements of specific array of detectors. System offers primary advantage (adjustability) of prior laboratory systems, but at cost, power, and size like those of prior dedicated, field-deployed systems.

Shu, Peter K.↗

Rapid oscillations in cataclysmic variables. IX - BG Canis Minoris (=3A 0729+103)

Results of a 10-yr photometric program on BG Canis Minoris, a novalike variable distinguished by the presence of a strictly coherent 913-s wave in its light curve, are presented. Long-term ephemerides for the orbital clock, which manifests itself through a 3.2-h light modulation, and the 913-s clock, are presented. The light curve exhibits a persistent 0.3 mag modulation at a period consistent with the 3.2-h spectroscopic period. Well-distributed timings of the orbital minima prove that the period is 0.1347486 day. It is inferred from the shape of the waveform and from the existence of X-ray dips with a sharp energy dependence that the modulation is caused by absorption. Power spectra of the nightly light curves show variable secondary features, in addition to the regular 913-s pulse. The 913-s period, presumably the first harmonic of the true white-dwarf spin period, is decreasing by 0.0022 s/yr.

Patterson, Joseph↗

Ultra-stable Hg(+) trapped ion frequency standard

We report the development of a fieldable frequency standard based on Hg-199(+) ions confined in a hybrid r.f./dc linear ion trap. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the r.f. confining fields. A 160 mHz wide atomic resonance line for the 40.5 GHz clock transition is used to steer the output of a 5 MHz crystal oscillator to obtain a stability of 2 x 10 exp -15 for 24,000 s averaging times. For longer averaging intervals, measurements are limited by instabilities in available hydrogen maser frequency standards. Measurements with 37 mHz linewidth for the Hg(+) clock transition demonstrate that the inherent stability for this frequency standard is at least as good as 1 x 10 exp -15.

Prestage, J. D.↗

Factors influencing the intensity of magnetospheric substorms

A definition of the substorm is presented, and it is shown that the typical isolated substorm is produced by the superposition of effects of processes directly driven by the solar wind through dayside reconnection and those driven by unloading through nighttime reconnection. The single factor that determines whether a substorm will occur or not is the clock angle of the interplanetary magnetic field (IMF) around the earth-sun line. Only when this field points south of the GSM equatorial plane do the auroral electrojet indices depart from their quiet values. For a given clock angle, the level of activity increases with the IMF strength and solar wind velocity.

Mcpherron, R. L.↗

256x256 switched-FET multiplexer for spaceborne astronomical applications

A novel cryogenic design of a source follower per detector (SFD) direct readout multiplexer is demonstrated. This design has proven to be a good prototype for the development of new low-noise large-area cryogenic multiplexers. In the absence of clocking noise, the readout demonstrates as low as about 30 electrons of rms read noise. There is still an excess noise component feeding through when the array is clocked, which manifests itself only at the lower temperatures. The shape of this component is dependent on a number of the bias voltages, and especially on the temperature of the chip. Analysis of the noise spectral density of the unit cell under various bias conditions shows that there is an excess spectral noise component at the lower temperatures.

Mcmurray, Robert E., Jr.↗

Evaluation of a 32 x 32 InSb CCD for use in astronomy

We have been fortunate to receive several infrared CCD array detectors on loan from Santa Barbara Research Center. The devices are evaluation samples, not commercially available at this time. Dr. Alan Hoffman of SBRC has made the arrangements for this loan and provided considerable technical support to this project. One aim of this project has been to evaluate the performance potential of this array technology, using astronomical objects. A quick summary of our findings is given. In short, we have found the imaging properties to be excellent under both low and high background conditions and the sensitivity to be quite good (each pixel is competitive with current InSb single-detector systems in use for astronomy). We anticipate improved low-background performance when we run these detectors at a lower and more stable temperature. The device characteristics are described, laboratory testing is summarized, and the first astronomical imaging is presented. Various circuits developed (clocks, clock drivers, DC supplies, clamp-amplifier, and a real time display system) are given.

Forrest, W. J.↗

In-flight identification of the Galileo spacecraft flexible mode characteristics

The Galileo scan platform is controlled in two degrees of freedom. A clock (Spin Bearing) actuator controls the relative position between the rotor and stator, and a cone actuator controls the position between the stator and the platform. Instruments on the platform are required to point to 140 micro-rad accuracy and 50 micro-rad per second stability. The system identification objectives were to identify dominant structural resonance frequencies, mode shapes, and damping ratio which exist in the transfer function between the clock actuator and the gyro sensor; and position the notch filter to limit undesirable actuator torque output to ensure stability and performance.

Wong, Edward C.↗