Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Missing Energy due to Nuclear Effects in Monoenergetic Neutrino Charged-Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from 𝐾 + → 𝜇 + ⁢𝜈 𝜇 decay at rest (𝐸 𝜈 𝜇 = 235.5 MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly 𝜈 𝜇 ⁢𝑛 → 𝜇 − ⁢𝑝 or 𝜈 𝜇 ⁢ 12 C → 𝜇 − ⁢ 12 N, we define the missing energy as the energy transferred to the nucleus (𝜔) minus the kinetic energy of the outgoing proton(s), 𝐸 𝑚 ≡ 𝜔−∑ 𝑇 𝑝 , and relate this to visible energy in the detector, 𝐸 𝑚 = 𝐸 𝜈 𝜇 ⁡(235.5 MeV) − 𝑚 𝜇⁡ (105.7 MeV) + [𝑚 𝑛 − 𝑚 𝑝⁡ (1.3 MeV)] − 𝐸 vis . The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g., nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a (77 ± 3)% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements, and Type-II supernova studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

Phonon density of states in uranium Laves phases UNi 2 and UCo 2

Recent computational work evaluated the phase stability of UCo 2 and UNi 2 in the C14, C15, and C36 Laves phases and reported their computationally determined phonon density of states. To corroborate these computational findings, we report the experimentally determined phonon density of states for UCo 2 and UNi 2 using inelastic neutron scattering at the wide angular-range chopper spectrometer at the Spallation Neutron Source at Oak Ridge National Laboratory. We found excellent agreement between experimental and computational results for UNi 2 and noted that some differences were observed for UCo 2 . Furthermore, by comparing the phonon density of states of UCo 2 with that of other U-bearing Laves phases, we found that UCo 2 showed distinct vibrational properties. From the one-phonon density of states, we calculated the lattice contribution to the specific heat of UNi 2 and UCo 2 . Finally, we bound the electronic contribution to the specific heat in UNi 2 .

Actinides↗

Cryogenic Neutron Protein Crystallography: routine methods and potential benefits

The use of cryocooling in neutron diffraction has been hampered by several technical challenges such as the need for specialized equipment and techniques. Recently we have developed and deployed equipment and strategies that allow for routine neutron data collection on cryocooled crystals using off the shelf components. This system has several advantages, compared to a closed displex cooling system such as fast cooling coupled with easier crystal mounting and centering. The ability to routinely collect cryogenic neutron data for analysis will significantly broaden the range of scientific questions that can be examined by neutron protein crystallography. Cryogenic neutron data collection for macromolecules has recently become available at the new Biological Diffractometer BIODIFF at FRM II and the Macromolecular Diffractometer (MaNDi) at the Spallation Neutron Source, Oak Ridge National Laboratory. To evaluate the benefits of a cryocooled neutron structure we collected a full neutron data set on the BIODIFF instrument on a Toho-1 lactamase structure at 100K.

Weiss, Kevin L.↗

Extracting grain-orientation-dependent data from in situ time-of-flight neutron diffraction. I. Inverse pole figures

The problem of calculating the inverse pole figure (IPF) is analyzed from the perspective of the application of time-of flight neutron diffraction to in situ monitoring of the thermomechanical behavior of engineering materials. On the basis of a quasi-Monte Carlo (QMC) method, a consistent set of grain orientations is generated and used to compute the weighting factors for IPF normalization. The weighting factors are instrument dependent and were calculated for the engineering materials diffractometer VULCAN (Spallation Neutron Source, Oak Ridge National Laboratory). The QMC method is applied to face-centered cubic structures and can be easily extended to other crystallographic symmetries. Examples include 316LN stainless steel in situ loaded in tension at room temperature and an Al–2%Mg alloy, substantially deformed by cold rolling and in situ annealed up to 653 K.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards neutron scattering experiments with sub-millisecond time resolution

Neutron scattering techniques offer several unique opportunities in materials research. However, most neutron scattering experiments suffer from the limited flux available at current facilities. This limitation becomes even more severe if time-resolved or kinetic experiments are performed. A new method has been developed which overcomes these limitations when a reversible process is studied, without any compromise on resolution or beam intensity. We demonstrate that, by recording in absolute time the neutron detector events linked to an excitation, information can be resolved on sub-millisecond timescales. Specifically, the concept of the method is demonstrated by neutron reflectivity measurements in time-of-flight mode at the Liquids Reflectometer located at the Spallation Neutron Source, Oak Ridge National Laboratory, Tennessee, USA, combined with in situ rheometry. Finally, the opportunities and limitations of this new technique are evaluated by investigations of a micellar polymer solution offering excellent scattering contrast combined with high sensitivity to shear.

36 MATERIALS SCIENCE↗

A Rietveld refinement method for angular- and wavelength-dispersive neutron time-of-flight powder diffraction data

This paper introduces a two-dimensional extension of the well established Rietveld refinement method for modeling neutron time-of-flight powder diffraction data. The novel approach takes into account the variation of two parameters, diffraction angle 2θ and wavelength λ, to optimally adapt to the varying resolution function in diffraction experiments. By doing so, the refinement against angular- and wavelength-dispersive data gets rid of common data-reduction steps and also avoids the loss of high-resolution information typically introduced by integration. In a case study using a numerically simulated diffraction pattern of Rh 0.81 Fe 3.19 N taking into account the layout of the future POWTEX instrument, the profile function as parameterized in 2θ and λ is extracted. As a proof-of-concept, the resulting instrument parameterization is then utilized to perform a typical refinement of the angular- and wavelength-dispersive diffraction pattern of CuNCN, yielding excellent residuals within feasible computational efforts. Another proof-of-concept is carried out by applying the same approach to a real neutron diffraction data set of CuNCN obtained from the POWGEN instrument at the Spallation Neutron Source in Oak Ridge. The paper highlights the general importance of the novel approach for data analysis at neutron time-of-flight diffractometers and its possible inclusion within existing Rietveld software packages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The suite of small-angle neutron scattering instruments at Oak Ridge National Laboratory

Oak Ridge National Laboratory is home to the High Flux Isotope Reactor (HFIR), a high-flux research reactor, and the Spallation Neutron Source (SNS), the world's most intense source of pulsed neutron beams. The unique co-localization of these two sources provided an opportunity to develop a suite of complementary small-angle neutron scattering instruments for studies of large-scale structures: the GP-SANS and Bio-SANS instruments at the HFIR and the EQ-SANS and TOF-USANS instruments at the SNS. This article provides an overview of the capabilities of the suite of instruments, with specific emphasis on how they complement each other. As a result, a description of the plans for future developments including greater integration of the suite into a single point of entry for neutron scattering studies of large-scale structures is also provided.

47 OTHER INSTRUMENTATION↗

Quantitative texture analysis using the NOMAD time-of-flight neutron diffractometer

Strategies for efficient and reliable texture measurements have been explored using the Nanoscale Ordered Materials Diffractometer (NOMAD) at the Spallation Neutron Source located at Oak Ridge National Laboratory (ORNL). To test these strategies, the texture of an Al alloy was also investigated using another neutron diffraction instrument, a constant-wavelength neutron diffractometer (NRSF2) located at the High Flux Isotope Reactor, also at ORNL. Reasonable agreement was found across the two experimental methods, but differences in overall texture strength and the symmetry of some components were noted, depending on the data reduction and analysis method selected. Finally, on the basis of these results, potential improvements are identified which would enhance the texture measurement capability on NOMAD.

47 OTHER INSTRUMENTATION↗

Simulating and benchmarking neutron total scattering instrumentation from inception of events to reduced and fitted data

In the design and realization of modern neutron scattering instrumentation, particularly when designing beamline concepts from the ground up, it is desirable to fully benchmark against realistically simulated data. This is especially true for total scattering beamlines, where the future deliverable data is to be analysed in both reciprocal- and real-space representations, and needs must be carefully balanced to ensure sufficient range, resolution and flux of the instrument. An approach to optimize the design of neutron scattering instrumentation via a workflow including ray-tracing simulations, event-based data reduction, heuristic analysis and fitting against realistically simulated spectra is demonstrated here. The case of the DISCOVER beamline concept at the Spallation Neutron Source is used as an example. The results of the calculations are benchmarked through simulation of existing instrumentation and subsequent direct comparison with measured data. Finally, on the basis of the validated models, the ability to explore design characteristics for future beamline concepts or future instrument improvements is demonstrated through the examples of detector tube size and detector layout.

47 OTHER INSTRUMENTATION↗

Quantitative texture analysis at the WAND 2 and HIDRA diffractometers

Data collection and analysis strategies have been developed for efficient and reliable crystallographic texture measurements at two recently upgraded neutron diffractometers: the Wide Angle Neutron Diffractometer Squared (WAND 2 ) and the High Intensity Diffractometer for Residual Stress Analysis (HIDRA) at the High Flux Isotope Reactor located at Oak Ridge National Laboratory. These methods are demonstrated using measurements on a variety of textured samples, including multi-phase steel composites and polycrystalline calcite (CaCO 3 ). Reference measurements were also made at VULCAN, the engineering diffractometer located at the Spallation Neutron Source. The texture data obtained on the different instruments are in agreement, and WAND 2 is more time efficient than HIDRA. Two analysis methods were investigated, single-peak fitting to obtain individual pole figures for inversion and Rietveld texture analysis using MAUD. Here, the impact of the differences between the various textures obtained was evaluated through the calculation of diffraction elastic constants, which is one application of the texture data collected. Both instruments were found to provide texture data that are suitable for complementing other analyses, such as residual stress mapping.

47 OTHER INSTRUMENTATION↗

Selected advances in small-angle scattering and applications they serve in manufacturing, energy and climate change

Innovations in small-angle X-ray and neutron scattering (SAXS and SANS) at major X-ray and neutron facilities offer new characterization tools for researching materials phenomena relevant to advanced applications. For SAXS, the new generation of diffraction-limited storage rings, incorporating multi-bend achromat concepts, dramatically decrease electron beam emittance and significantly increase X-ray brilliance over previous third-generation sources. This results in intense X-ray incident beams that are more compact in the horizontal plane, allowing significantly improved spatial resolution, better time resolution, and a new era for coherent-beam SAXS methods such as X-ray photon correlation spectroscopy. Elsewhere, X-ray free-electron laser sources provide extremely bright, fully coherent, X-ray pulses of <100 fs and can support SAXS studies of material processes where entire SAXS data sets are collected in a single pulse train. Meanwhile, SANS at both steady-state reactor and pulsed spallation neutron sources has significantly evolved. Developments in neutron optics and multiple detector carriages now enable data collection in a few minutes for materials characterization over nanometre-to-micrometre scale ranges, opening up real-time studies of multi-scale materials phenomena. SANS at pulsed neutron sources is becoming more integrated with neutron diffraction methods for simultaneous structure characterization of complex materials. In this paper, selected developments are highlighted and some recent state-of-the-art studies discussed, relevant to hard matter applications in advanced manufacturing, energy and climate change.

36 MATERIALS SCIENCE↗

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION↗

Multidimensional Rietveld refinement of high-pressure neutron diffraction data of PbNCN

High-pressure neutron powder diffraction data from PbNCN were collected on the high-pressure diffraction beamline SNAP located at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (Tennessee, USA). The diffraction data were analyzed using the novel method of multidimensional (two dimensions for now, potentially more in the future) Rietveld refinement and, for comparison, employing the conventional Rietveld method. To achieve two-dimensional analysis, a detailed description of the SNAP instrument characteristics was created, serving as an instrument parameter file, and then yielding both cell and spatial parameters as refined under pressure for the first time for solid-state cyanamides/carbodiimides. The bulk modulus B 0 = 25.1 (15) GPa and its derivative B ′ 0 = 11.1 (8) were extracted for PbNCN following the Vinet equation of state. Surprisingly, an internal transition was observed beyond 2.0 (2) GPa, resulting from switching the bond multiplicities (and bending direction) of the NCN 2− complex anion. The results were corroborated using electronic structure calculation from first principles, highlighting both local structural and chemical bonding details.

Meinerzhagen, Yannick↗

pathSQE : an automated workflow for single-crystal inelastic neutron scattering data processing and analysis

Inelastic neutron scattering (INS) experiments utilizing modern time-of-flight spectrometers enable the comprehensive mapping of the energy (E)- and momentum (Q)-resolved dynamical structure factor of single crystals, probing both the lattice and magnetic excitations. Yet, the large size and complexity of four-dimensional INS data are challenging current analysis workflows, often resulting in an underutilization of the measured information. To help address this issue, this paper introduces new software interfaced with the Mantid framework, pathSQE, designed to streamline the processing, analysis and interpretation of 4D single-crystal INS data. By automating key tasks such as 1D/2D slicing, symmetrization, Brillouin zone folding, data visualization, prioritization and filtering, and comparisons with simulations, pathSQE facilitates and accelerates INS data analysis workflows. Here, this paper outlines the features and implementation and provides several illustrations of the use of pathSQE on data collected on single crystals using direct-geometry time-of-flight spectrometers at the Spallation Neutron Source, including Ge, FeSi, MnO and SnS single-crystal measurements on the ARCS, HYSPEC and CNCS neutron spectrometers. Beyond streamlining post-experiment data processing, pathSQE establishes an automated and modular processing pipeline that could support future real-time experiment steering.

36 MATERIALS SCIENCE↗