Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Using energy storage systems to extend the life of hydropower plants

Despite their advantages, distributed energy resources (DERs) bring inherent uncertainty and variability into the landscape of modern power systems. As DER penetration grows, conventional generators like hydropower plants have to respond more often to arrest the imbalance in the net load. Hydropower turbines provide their best operational performance with minimal wear and tear when operating at regions of maximum efficiency. However, the current needs for hydropower plants require them to operate under varying load conditions and thus sub-optimal operating points leading to additional stress. To relieve the hydropower plants, this paper proposes a hybridization strategy where a hydropower unit is paired with an energy storage system (ESS) to increase operational flexibility and mitigate damage to the hydro plant. Models are developed to represent the operation of the hybrid system, quantify degradation, and assess economic benefits. Moreover, an innovative controller disaggregates the market dispatch signal into separate control setpoints for the ESS and hydropower unit. In case studies performed on a real-world hydropower facility, it was found that the ESS-based hybridization can extend the life of the hydropower plant by 5% on average. Notably, the economic benefits from reduced maintenance and deferred investment are estimated to be around $3.6 million.

13 HYDRO ENERGY↗

Analysis of Truck Platooning on Rural Highways

An analysis by the National Laboratory of the Rockies on truck platooning technology used on Ohio highways found that truck platooning operated for 40% of driving distances, showcasing its potential to enhance freight efficiency and safety. While energy savings were evident, further optimization of gap distances and operational consistency is needed to fully evaluate fuel savings benefits across diverse driving conditions. While more study is needed, advanced connected and automated vehicle technologies such as platooning demonstrate significant promise for transforming commercial vehicle efficiency and operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bonneville Dam Powerhouse 2 Gatewell Improvement Post Construction Evaluation (Final Report)

Modifications to vertical barrier screens (VBS) and the addition of concrete corbels to improve passage conditions for juvenile salmonids in the gatewells of Bonneville Dam’s second powerhouse (B2) were completed prior to the 2024 passage season. To evaluate the effectiveness of those modifications, PNNL carried out a post construction evaluation to contrast fish condition and mortality between two turbine unit operational ranges within the peak efficiency range. A block-treatment study design was implemented in 2024 to contrast descaling and mortality of juvenile salmonids sampled in the juvenile fish facility following exposure to turbine operations (middle versus upper 1% peak efficiency range) during spring and summer passage periods. In spring, 1.96% of juvenile salmonids sampled during mid-1% operations were descaled and 0.46% were mortalities. Of those sampled during upper 1% unit operations in spring, 2.90% were descaled and 0.95% were mortalities. Although these differences appeared to be meaningful, substantial exceedances of the upper 1% limit occurred during two treatment blocks of the spring study period. Fish collected during the upper 1% treatment of these two blocks experienced substantially higher rates of descaling and mortality compared to those collected during mid-1% treatments. Censoring these two upper 1% samples from the spring study period resulted in upper 1% descaling and mortality rates that were statistically similar to those from the mid-1% treatment. During the summer study period, 0.99% of juveniles sampled during mid-1% operations were descaled and 0.33% suffered mortality; these rates were significantly lower than the descaling (2.80%) and mortality (1.73%) rates observed during upper 1% treatments. Comparing the results from the 2024 study to those from the historical (2008–2013) baseline of unmodified units revealed that the descaling and mortality rates observed during upper 1% operations in spring 2024 were near the upper end of the historic range observed for mid-1% operations. Spring 2024 upper 1% descaling and mortality rates were below, or well below the median of historical mid and upper 1% (combined) rates, which suggests that the modifications have had a positive effect. Summer 2024 upper 1% descaling and mortality rates were at or above the top of the range of historical mid 1% and above or well above the median of historical mid and upper 1% (combined) rates. It is important to keep in mind that 2024 is a single year when considering these comparisons. Additional study could help confirm these results or seek a level of operation that achieves the desired outcomes for fish.

13 HYDRO ENERGY↗

Modular SOEC System for Efficient H 2 Production at High Current Density

The overall objective of the project was to demonstrate the potential of Solid Oxide Electrolysis Cell (SOEC) systems to produce hydrogen at a cost of $\$$2.00/kg H 2 or less (excluding delivery, compression, storage, and dispensing). An additional objective of the project was to enhance Solid Oxide Electrolysis Cell (SOEC) stack endurance and impart subsystem robustness for operation on load profiles compatible with intermittent renewable energy sources. The project was designed to achieve the overall objectives through a multi-disciplinary approach that included SOEC stack and materials development, systems development and optimization, techno-economic analyses, and ultimately the demonstration of a > 4 kg H 2 /day SOEC system. The scope of work included research and development efforts to develop an advanced, high temperature, water splitting (HTWS) system with superior performance and durability relative to the current state-of-the-art. In support of the aforementioned goals, the project activities included: 1) Develop and test cell materials with improved endurance at high current densities; 2) Design and fabricate a >4 kg H 2 /day SOEC stack optimized for high efficiency operation in the range of 1 - 2 A/cm 2 ; 3) Perform stack testing under simulated system conditions; 4) Perform systems analysis including configuration and parametric studies, to maximize SOEC system efficiency and minimize H 2 production costs; 5) Develop the conceptual design of a >4 kg H 2 /day thermally self-sustaining SOEC demonstration system including stack module and balance of plant (BoP).

08 HYDROGEN↗

An electrified boom actuation system with energy regeneration capability driven by a novel electro-hydraulic unit

This paper presents a novel electrified solution for linear actuation systems, which has undergone a successful in-vehicle demonstration, marking a significant advancement in this field. Aligned with the growing trend towards electrification, this solution holds promise for a wide range of off-road applications. The showcased electrohydraulic actuation architecture enables efficient four-quadrant operation and incorporates energy recovery capabilities. At the core of the system lies a distinctive electro-hydraulic unit, integrating a fixed hydraulic pump and a variable-speed electric motor into a compact and powerful entity. A specialized hydraulic system is designed to efficiently transform electrical energy from the electro-hydraulic unit into boom cylinder actuation. The sizing of the system is determined by the boom operation of a commercial compact loader. The maximum power output of the electro-hydraulic system is approximately 15 kW. The components of the proposed system are integrated into the reference vehicle, and comprehensive performance tests are conducted. The results of the tests performed on the vehicle with the boom lifting and lowering cycle indicate an overall system efficiency of 60%. The electrified solution consumes only about one-third of the energy used by the conventional boom actuation system on the reference machine, while exhibiting energy savings exceeding 75% during specific work phases. The energy savings come mainly from energy regeneration and minimal loss from throttling through the specialized hydraulic circuit design. Finally, the successful demonstration on the reference vehicle underscores the practicality and effectiveness of the proposed electrified solution in current mobile hydraulic applications

42 ENGINEERING↗

High-Efficiency Mixing Controlled Compression Ignition Combustion of Propane DME Blends

The program is a multi-institutional effort led by the University of Wisconsin-Madison Engine Research Center, partnered with WM International and the University of Central Florida, aiming to revolutionize combustion technology for medium-duty commercial vehicles. The project’s primary objective is to develop a high-efficiency mixing controlled compression ignition (MCCI) combustion strategy utilizing propane and propane/DME blends. This development is crucial because current propane-fueled spark-ignited (SI) engines operate at substantially lower efficiencies (BTE of 31.5%) than comparable modern diesel engines (37.1%).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Banking Scoring and Rating for Coherent Risk Measures in Electricity Systems ABSCORES

This project developed a framework for asset and system risk management that can be incorporated into current electricity system operations to improve economic efficiency and establish an Electric Assets Risk Bureau. We leveraged scoring and ratings from banking and financial institutions alongside current optimization methods in dispatching power systems to help system operators and electricity markets schedule resources. This approach is based on the observation that there are major discrepancies between the power scheduled by a system operator and the actual power generated/consumed. These discrepancies—exacerbated by unplanned contingencies (e.g., natural disasters)—are caused by multiple factors, including the different financial, environmental and risk preferences of power producers, consumers, and aggregators. We developed a framework that counteracts two failures in electricity system operations: imperfect information and missing markets for products. The technical approach included five tasks. Tasks 1 and 2 supported the development of risk scores at the asset level with historical data collected for this project. Tasks 3, 4, and 5 incorporated scoring into decision-making at the system level. The proposed effort achieved PERFORM's Program Objectives because the proposed outputs and algorithms do not exist in the electricity industry and are an innovative approach to managing risk. Since the acknowledged need to better assess and act upon risk profiles for grid assets has not been met by the industry, this project will also impact ARPA-E's Mission Areas, including improving energy efficiency and giving the U.S. a technological lead in advanced energy technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulation of 15% and 50% Thermal Power Dispatch to an Industrial Facility Using a Flexible Generic Full-Scope Pressurized Water Reactor Plant Simulator

Nuclear power plants in the United States are increasingly challenged to compete in wholesale electricity markets due to the low electricity costs and increasingly dynamic grid conditions from competing generation sources. An alternative market for nuclear power is industrial facilities that can use the thermal and/or electrical power generated by a nuclear power plant to offset the economic losses incurred by electricity market challenges. A generic pressurized water reactor (PWR) simulator was used to show the results of a basic design for a generic thermal power extraction system and tests were run using a set of procedures to show what happens when a nuclear power plant transitions from full electrical power dispatch to 15% and 50% thermal power dispatch. This type of operation leads to losses in turbine performance efficiency due to the deviation from the design operating point, but because the thermal power is also used by the industry load without conversion losses, the combined thermal efficiency of the PWR increases. For the 15% case, the thermal efficiency increased from 32% to 41.9%, while for the 50% case, the efficiency increased up to 60.1%. In addition, for 50% thermal power dispatch, the power dissipated by the condenser decreased from approximately 2000 to approximately 1300 MW (thermal), indicating a substantially diminished impact on the environment in terms of releasing heat into the cooling water reservoir.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

How Low Can You Go? Nanoscale Membranes for Efficient Water Electrolysis

Motivated by the need to lower the cost of hydrogen (H 2 ) production by water electrolysis, significant research efforts are focused on making proton (H + ) exchange membrane (PEM) water electrolyzers more efficient and capable of operating at higher current densities. These aims can be met by making H + -conducting membranes thinner, which has the effect of lowering ohmic drops across the membrane that represent the largest efficiency loss at high current densities (>2 A cm –2 ). However, decreasing membrane thickness below 50 μm is not trivial due to trade-offs between membrane resistance, H 2 crossover (safety), membrane degradation, and manufacturing throughput. Furthermore, descriptions of key processes, limitations, and trade-offs that arise in thin membranes are provided that can be used to guide the design of ultrathin (i.e., submicron thick), low-resistance membrane materials that have the potential to transform the field of clean H 2 production.

08 HYDROGEN↗

Application of a temporal multiscale method for efficient simulation of degradation in PEM Water Electrolysis under dynamic operating conditions

Hydrogen is emerging as a vital energy carrier, driven by the need to reduce carbon emissions. Proton Electrolyte Membrane Water Electrolysis (PEMWE) enables hydrogen production under fluctuating renewable power conditions but requires improved understanding and stability of the anode catalyst layer under dynamic operating conditions, especially with low noble metal loadings. Long-term degradation experiments are both time-consuming and costly; therefore, a systematic, model-aided approach is essential. In the present work, a temporal multiscale method is applied to reduce the computational effort of simulating long-term degradation processes in PEMWE, with an exemplary focus on catalyst dissolution. A mechanistic model incorporating the oxygen evolution reaction, catalyst dissolution, and hydrogen permeation from the cathode to the anode was hypothesized and implemented. In this way, the local periodicity of transport and reaction processes in dynamic PEMWE operation, which influence the gradual degradation of the catalyst layer, is captured. The temporal multiscale method significantly reduces the computational effort of simulation, decreasing processing time from hours to mere minutes. This efficiency gain is attributed to the limited evolution of Slow-Scale variables during each period of time P of the Fast-Scale variables. Consequently, simulation is required only until local periodicity is achieved within each Slow-Scale time step. Hence, the fully resolved dynamic problem is decoupled into these two scales, employing a heterogeneous multiscale technique. The developed approach effectively accelerates parameter estimation and predictive simulations, supporting systematic modeling of PEMWE degradation under dynamic conditions.

08 HYDROGEN↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Supporting Growth of a Skilled Workforce in the Building Energy Efficiency Industry (Final Technical Report)

The Interstate Renewable Energy Council (IREC), having worked for well over a decade to develop national networks and best practices focused on attracting and training high quality workers for the clean energy industries, sought to address shortfalls in skilled workers who build, retrofit, operate, and maintain energy efficient buildings. Through this project, IREC created and promoted a Green Buildings Career Map (GBCM)—a career awareness and recruitment tool—that seeks to boost the nationwide growth of workers entering the energy efficiency (EE) industry. Working with a team of subject matter experts and our partner organizations—Building Performance Association (BPA), Building Performance Institute (BPI), Community Action Partnership (CAP), and the National Institute of Building Sciences (NIBS)—IREC produced an interactive, engaging career map to attract and motivate individuals into pursuing careers in energy efficiency, and in support of the Weatherization Assistance Program. The GBCM was designed for a broad audience including educators, career advisors, employers, policymakers, workforce professionals, and jobseekers who may otherwise have little or no awareness of the exciting and rewarding opportunities within targeted industry sectors. Most individuals seeking careers do not know about the breadth of careers awaiting them in the built environment and the same is true for most career and guidance counselors, educators, and parents. The GBCM provides this broad audience with a vision of the myriad jobs that could lead to a long-standing career in energy efficiency. The GBCM describes diverse occupations across the EE industry, charts possible progression between those occupations, and identifies the training, skills, and credentials necessary to do them well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent System Partitioning for Agent-Based Security Constrained Optimal Power Flow

This project developed scalable, computationally efficient algorithms to solve realistic large-scale power system optimization problems as part of a larger series of competitions run by ARPA-E. These problems are important because the secure and reliable operation of the power grid, especially under increased uncertainty and variability, is growing increasingly challenging. The economic feasibility of the proposed methods developed by our team is quite low, considering it’s a purely software-based solution to operate power grids more efficiently. The technical effectiveness, as evidenced by our performance in the competition, balances heuristics and approximations to provide a tradeoff between speed and accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast simultaneous feasibility testing and applications for electrical power grids

Fast simultaneous feasibility testing (SFT) for management of an electrical power grid is achieved through various innovations. The computation problem relates to evaluation of candidate solutions for external power flows into a power grid, with respect to predetermined constraints and contingencies. Storage and computations are reduced by formulating the problem in terms of transactional nodes (e.g. third party connections for generators and loads) instead of the larger number of bus nodes. Further advantages are achieved by precomputing matrices that can be reused across multiple SFT invocations, organizing matrices and operations to reduce storage and computation, and eliminating branches that have no contingency violations. The fast SFT further enables new applications for integrating SFT with a Security-Constrained Unit Commitment (SCUC) optimizer for efficient single pass solutions; operating SFT as a service to multiple SCUC solvers; or integration with Security-Constrained Economic Dispatch (SCED) optimization.

97 MATHEMATICS AND COMPUTING↗