Engineering PapersSearch

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION

A Novel Design for Switchable Grid-Following and Grid-Forming Control

This paper presents the design of a novel grid- forming (GFM) control structure adapted from a typical grid- following (GFL) control structure with minimal edits, thereby enabling a switchable control structure for voltage sourced converters (VSCs) to operate in either GFL or GFM mode by simply switching a flag manually. The VSC is shown to be able to operate in the GFL control mode synchronizing to the main grid through a phase-locked-loop (PLL) and operate as a GFM controller with power-based synchronization for both grid-connected and islanded conditions. To guarantee smooth operation, the control schemes and the mode switching logic have been carefully designed and examined via a series of experiments. Here, the experiment results show that the switchable control structure can fulfill the desired control and operation functions and enable smooth transition between control modes.

14 SOLAR ENERGY

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION

Control and Real-Time Simulation of Microgrids with EV Fast-Charging and Grid-Forming Resources

Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.

14 SOLAR ENERGY

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION

Pulse Electrodeposition for Carbonate-Rich Deposits from Seawater

Seawater electrodeposition is gaining renewed interest in the context of sustainable development, both to build climate-resilient coastal infrastructure and for ocean-based decarbonization applications. Most of the applications benefit from CaCO 3 -rich deposits, but constant-voltage electrodeposition results in a mixture of CaCO 3 and Mg(OH) 2 , especially at higher voltages where precipitation rates are more desirable. The use of pulse voltages can help control interfacial pH that dictates the precipitation reactions. Here, we explore the use of pulse electrodeposition as a function of pulse frequency and duty cycle to control deposit composition. The most CaCO 3 -rich deposits were obtained under 10 Hz frequency and 10% duty cycle conditions for the voltage window investigated (-0.8 V to -1.2 V vs. SCE). While pulsing the voltage increases the amount of CaCO 3 deposited, the energy required per gram of CaCO 3 is significantly higher (14.5×) when compared to the base case of applying a constant voltage of -0.8 V vs. SCE. Further optimization of pulse conditions, electrode materials, and system configuration could lead to finding parameters that result in exclusively carbonate deposits without compromising precipitation rates, which may prove to be more useful for corrosion protection, coastal infrastructure, and other applications in sustainable development.

54 ENVIRONMENTAL SCIENCES

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION

Anticathode effect on electron kinetics in electron beam generated E × B plasma

Electron beam (e-beam) generated plasmas with applied crossed electric and magnetic (E x B) fields are promising for low damage processing of materials with applications to microelectronics and quantum information systems. In cylindrical e-beam E x B plasmas, radial confinement of electrons and ions is achieved by an axial magnetic field and radial electric field, respectively. To control the axial confinement of electrons, such e-beam generated plasma sources may incorporate a conducting boundary known as an anticathode, which is placed on the axially opposite side of the plasma from the cathode. In this work, it is shown that varying the anticathode voltage bias can control the degree to which the anticathode collects or repels incident electrons, allowing control of warm electron (electron energies in 10–30 eV range) and beam electron population confinement. It is suggested that the effect of the anticathode bias on the formation of these distinct electron populations is also associated with the transition between weak turbulence and strong Langmuir turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de

A Two-Stage Approach for PV Inverter Engagement in Power Factor Correction and Voltage Regulation

The rapid integration of distributed energy resources, like solar photovoltaics (PVs), can lead to overvolt-age challenges due to reverse power flow and a noticeable decrease in power factor at the substation interface. While existing literature extensively explores utilizing smart inverter capabilities for reactive power flexibility using a volt-var curve (VVC), obtaining time-varying operating points of such curves in real-time is challenging due to computational demands and communication requirements. Similarly, employing optimization-based approaches for reactive power control and active voltage regulation in large-scale distribution feeders is difficult due to the complexity of the problem and the challenges in effectively engaging customer-owned resources. This paper proposes a two-stage strategy to harness smart inverters for reactive power support. The first stage formulates short-term planning by optimally designing VVCs (on a daily or hourly basis) for large-scale solar PVs based on projected system needs and communicating optimal curves to smart inverters in advance. Subsequently, the second stage employs a transactive-based method to involve customer-owned PVs for reactive power support, effectively enhancing overall system performance and addressing real-time demands. In conclusion, the efficacy of this approach will be demonstrated using real-world distribution circuits provided by Vermont Electric Power Company (VELCO) and Vermont Electric Cooperative (VEC).

Poudel, Shiva [Pacific Northwest National Laborato

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION

Wireless Pulse-Width Modulation Control of Power Converters Using Ultra-Wideband Technology for Distributed High-Voltage Systems

In this study, we present a new approach for wireless pulse-width modulation (PWM) control of a power converter, applicable to numerous power converters within a complex electrical distribution system. This method eliminates the need for multiple physical connections of gating/PWM signals among distributed converter modules. By using ultra-wideband-based communication, the PWM control signals can be wirelessly transmitted from a central controller to multiple converters simultaneously and seamlessly. System stability is thoroughly analyzed, and experimental results validate the efficacy of the wireless control scheme for a buck converter operating at a 50-kHz switching frequency. The minimum latency obtained from this setup is 5.38 ..mu..s. This control concept offers easier implementation of distributed control in high-voltage power systems, especially in multilevel architectures, even under harsh conditions with ambient noise.

ADVANCED PROPULSION SYSTEMS

Wireless Pulse-Width Modulation Control of Power Converters Using Ultra-Wideband Technology for Distributed High-Voltage Systems: Preprint

In this study, we present a new approach for wireless pulse-width modulation (PWM) control of a power converter, applicable to numerous power converters within a complex electrical distribution system. This method eliminates the need for multiple physical connections of gating/PWM signals among distributed converter modules. By using ultra-wideband-based communication, the PWM control signals can be wirelessly transmitted from a central controller to multiple converters simultaneously and seamlessly. System stability is thoroughly analyzed, and experimental results validate the efficacy of the wireless control scheme for a buck converter operating at a 50-kHz switching frequency. The minimum latency obtained from this setup is 5.38 mus. This control concept offers easier implementation of distributed control in high-voltage power systems, especially in multilevel architectures, even under harsh conditions with ambient noise.

ADVANCED PROPULSION SYSTEMS

Bistable Optical Semiconductor Switching Based on C-Doped GaN

Highly resistive gallium nitride (GaN) is an essential material for power optoelectronic applications. While carbon doping is widely used to achieve semi-insulating properties in GaN, the persistent photoconductivity (PPC) arising from deep-level defect traps remains a major obstacle for high-speed power switching. This study demonstrates a novel approach: leveraging the ultrahigh photoresponsivity of GaN:C (up to 2.1 A ⋅ cm/W ⋅ kV, surpassing alternatives such as GaN:Fe) and employing defect-selective optical control to effectively quench the PPC. By synchronizing a short infrared (1064 nm) quenching pulse with UV (385 nm) excitation in an epitaxially grown GaN:C layer on a heavily doped n-type GaN substrate, we achieve a dramatic reduction in photocurrent fall time by approximately 293× (from 470 to 1.6 μ s), increasing modulation bandwidth from 745 Hz to nearly 218 kHz. Here, this advancement not only establishes a new pathway for controlling PPC in GaN:C but also enables the practical integration of GaN:C in fast power switching devices. Enhanced modulation bandwidth, along with GaN:C excellent photoresponsivity, makes it a promising candidate for optically controlled high-voltage, high-power electronic systems, such as photoconductive semiconductor switches (PCSSs) used in pulsed-power drivers, high-power microwave (HPM) sources, and high-voltage gate drivers for wide bandgap (WBG) power electronics.

Carbon-dopped Gallium nitride (GaN:C)