Engineering PapersSearch

SEARCH · Engineering Papers

Results for “power factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

782 records · Page 5

Cross-scale interaction between microturbulence and meso-scale reversed shear Alfvén eigenmodes in DIII-D plasmas

Abstract This paper reports global nonlinear gyrokinetic simulations that couple meso-scale reversed shear Alfvén eigenmodes (RSAEs) driven by energetic particles (EPs) and ion temperature gradient (ITG) microturbulence driven by thermal plasma, using equilibrium and profiles from DIII-D discharge #159243. In simulations focusing only on the ITG, electrostatic ITG drives a huge thermal ion heat transport, which is reduced by a factor of 10 to a level close to the experimental value in electromagnetic simulation due to finite β effect. In the simulations coupling the RSAE and ITG, ITG can scatter the resonant EP nonlinearly trapped by the RSAE and damp the zonal flows generated by the RSAE. The regulation of the RSAE by the ITG greatly reduces the initial saturation amplitude of the RSAE but increases the RSAE amplitude and associated EP transport to experimental levels in the quasi-steady state. The RSAE effects on the ITG, specifically the stronger zonal flows generated by the RSAE and the RSAE frequency modulation of the ITG-induced thermal ion heat transport, in turn, leads to a reduction of the thermal ion heat transport by more than a factor of 2 . For a stronger background ITG, the regulation of the RSAE by the ITG is stronger, while the RSAE effects on the ITG are weaker. This work highlights the importance of cross-scale coupling in the dynamics of the AE turbulence and EP transport.

Physics

Fluid-Thermal-Structural Interactions Induced by an Asymmetric Shock-Wave/Boundary-Layer Interaction in a Mach-6 Compression Corner

An experimental study is conducted of the fluid-thermal-structural interaction of a clamped compliant panel exposed to a three dimensional shock-wave/boundary-layer interaction (SWBLI) induced by a Mach-6 compression ramp with a spanwise nonuniform incoming boundary layer. The nonuniform boundary layer was produced by placing trips on one side of the upstream flat plate, resulting in largely turbulent flow on the tripped side and transitional flow on the untripped side. Measurements of the flowfield confirmed that the tripped boundary layer contained elevated levels of unsteadiness, and the SWBLI was observed to vary from attached to fully separated as the ramp angle was increased from 10◦ to 38◦; the separation region on the tripped side of the panel was noticeably smaller, showing the elevated turbulence levels of the tripped-side flow to remain relatively localized rather than diffusing across the whole model. Full-field, time-resolved panel deformations were measured using high-speed photogrammetry and the vibrational response at each compression angle was characterized. Although the measured modes conformed largely to those from classical clamped-plate theory, some skewing of the mode shapes was observed. IR thermography highlighted regions of the compliant region where elevated temperatures were likely to promote thermal softening effects to the transient panel response. The quasi-static deformation and stress field was used to characterize the internal stress factor of each mode and showed a meaningful relationship between transient panel response and stress contained within each mode: modes with antinodes lying in high-stress areas of the plate tended to exhibit increases in vibrational frequency and decreases in vibrational power, whereas the opposite was true for modes with antinodes in low-stress areas.

Spectral Proper Orthogonal Decomposition

Determining Stellar Elemental Abundances from DESI Spectra with the Data-driven Payne

Abstract Stellar abundances for a large number of stars provide key information for the study of Galactic formation history. Large spectroscopic surveys such as the Dark Energy Spectroscopic Instrument (DESI) and LAMOST take median-to-low-resolution (R≲ 5000) spectra in the full optical wavelength range for millions of stars. However, the line-blending effect in these spectra causes great challenges for elemental abundance determination. Here we employDD-Payne, a data-driven method regularized by differential spectra from stellar physical models, to the DESI early data release spectra for stellar abundance determination. Our implementation delivers 15 labels, including effective temperatureT eff , surface gravity log g , microturbulence velocityv mic , and the abundances for 12 individual elements, namely C, N, O, Mg, Al, Si, Ca, Ti, Cr, Mn, Fe, and Ni. Given a spectral signal-to-noise ratio of 100 per pixel, the internal precisions of the label estimates are about 20 K forT eff , 0.05 dex for log g , and 0.05 dex for most elemental abundances. These results agree with the theoretical limits from the Crámer–Rao bound calculation within a factor of 2. The majority of the accreted halo stars contributed by the Gaia–Enceladus–Sausage are discernible from the disk and in situ halo populations in the resultant [Mg/Fe]–[Fe/H] and [Al/Fe]–[Fe/H] abundance spaces. We also provide distance and orbital parameters for the sample stars, which spread over a distance out to ∼100 kpc. The DESI sample has a significantly higher fraction of distant (or metal-poor) stars than the other existing spectroscopic surveys, making it a powerful data set for studying the Galactic outskirts. The catalog is publicly available.

Astronomy & Astrophysics

A Summary of Test and Analysis Results from a Second Lift+Cruise Full-Scale Drop Test

The realization of advanced air mobility markets is enabling new forms of transportation to take shape in the United States and around the world. Though currently in development, as these markets mature, new types of vertical take-off and landing (VTOL) vehicles have been undergoing development for use. There are many factors which must be addressed prior to these types of vehicles becoming viable alternative forms of transportation in these markets. These factors include incorporation into the existing airspaces, the logistics of operating in urban environments, along with numerous factors associated with safety and reliability. To address some of the safety aspects associated with the development of these new types of vehicles, NASA has been conducting research into the performance of an example electric VTOL (eVTOL) aircraft as a part of the Revolutionary Vertical Lift Technology (RVLT) project. Over the course of this research, many aspects including the development of energy absorbing components, the evaluation of seating systems, the development of advanced finite element material model systems and the acquisition of full-scale vehicle impact data were investigated. The report will discuss aspects related to the acquisition of full-scale vehicle data which occurred in the form of a full-scale impact test conducted in the Summer of 2025. This test was on a NASA designed Lift+Cruise composite cabin test article and represented a partial capstone in the entirety of previous eVTOL research conducted for the project. In this test, a variety of experiments were included in order to investigate the effect of a full-scale environment on the experiment results. In parallel, the development of a computational impact model to simulate the full-scale test will be discussed in this report. A model of the Lift+Cruise test article was developed utilizing data collected from previous sub- and full-scale test data and then simulated in the current test environment. The model development, its use in pre-test predictions, and its use in post-test correlation will all be presented. This report will present the test data acquired from the Lift+Cruise test and document several of the results obtained. One intended result is to determine the effect of a complex full-scale crash impact on the identification of occupant injury risk within seat and vehicle designs. A second intended result is to determine whether high-fidelity models can be used with some confidence in the prediction of test events and can allow for additional test cases to be simulated without the need of having to conduct additional tests. The overall goal of the test is to provide the community with data that can be used for design, development or certification efforts, along with providing data on what an example eVTOL crash incident could entail.

energy storage systems

Survey of Supersonic Inlets for High Mach Number Applications

The various inlet design philosophies are assessed on the basis of recent experimental results obtained at Mach numbers up to 5. The basic compression systems (external, internal, and combined external-plus-internal) are compared for both Mach 4.0 turbojet and hypersonic-cruise ramjet engines. The inlet that appears best suited for the Mach 4.0 turbojet application is that with combined external-plus-internal compression. Because of the severe cooling and weight problems associated with variable geometry at hypersonic flight speeds, the fixed-geometry self-starting characteristics of external-compression systems may be the overriding factor in the selection of an inlet for the hypersonic-cruise ramjet.

James F Connors

Improved Treatment of Global Positioning System Force Parameters in Precise Orbit Determination Applications

Data collected from a worldwide 1992 experiment have been processed at JPL to determine precise orbits for the satellites of the Global Positioning System (GPS). A filtering technique has been tested to improve modeling of solar-radiation pressure force parameters for GPS satellites. The new approach improves orbit quality for eclipsing satellites by a factor of two, with typical results in the 25- to 50-cm range. The resultant GPS-based estimates for geocentric coordinates of the tracking sites, which include the three DSN sites, are accurate to 2 to 8 cm, roughly equivalent to 3 to 10 nrad of angular measure.

Y Vigue

Examination of Regional Trends in Low Level Cloud Properties Found in the Aqua-MODIS Satellite Record

Clouds have a pronounced influence on the Earth?s climate. Relative to cloud free conditions, they cool the planet by increasing the amount of solar radiation reflected back to space and reducing the amount of sunlight reaching the surface, but they warm the planet by decreasing the amount of thermal infrared radiation escaping to space and increasing the amount reaching the surface (a greenhouse effect). The global mean net cloud radiative effect (CRE) is about -20 W/m2, a cooling effect at both the top-ofatmosphere and surface. Given the magnitude of CRE?s, it is expected that changes in cloud properties could be a significant factor in climate change due to anthropogenic forcing?s, yet cloud feedbacks are not well known and remain one of the largest uncertainties in climate prediction. This paper explores relationships between coincident observations of atmospheric aerosols, clouds and radiation derived from the Moderate Resolution Imaging Spectroradiometer (MODIS) and from the Clouds and the Earth?s Radiant Energy System (CERES) instruments on the Aqua satellite. We investigate several interesting regional trends that have emerged in the nearly 18-year satellite record that suggest correlation between changes in low-level cloud properties and changes in aerosol optical depth that may be associated with changes in pollution emissions and possibly with other factors. MERRA reanalysis of meteorological conditions and aerosol particulate species are investigated to help better understand the potential mechanisms responsible for the observed cloud property trends. Finally, we analyze a new CERES flux by cloud type dataset in order to try and isolate the associated trends in low-level cloud radiative effects. It is anticipated that this study using long-term observations of clouds, aerosols and radiative fluxes combined with model reanalysis data will contribute to an improved understanding of cloud climate feedbacks.

William L Smith Jr.

Reserve Li/SOC12 Battery Safety Testing

A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

Dils, C. T.

Returning an Entire Near-Earth Asteroid in Support of Human Exploration Beyond Low-Earth Orbit

This paper describes the results of a study into the feasibility of identifying, robotically capturing, and returning an entire Near-Earth Asteroid (NEA) to the vicinity of the Earth by the middle of the next decade. The feasibility of such an asteroid retrieval mission hinges on finding an overlap between the smallest NEAs that could be reasonably discovered and characterized and the largest NEAs that could be captured and transported in a reasonable flight time. This overlap appears to be centered on NEAs roughly 7 m in diameter corresponding to masses in the range of 250,000 kg to 1,000,000 kg. The study concluded that it would be possible to return a approx.500,000-kg NEA to high lunar orbit by around 2025. The feasibility is enabled by three key developments: the ability to discover and characterize an adequate number of sufficiently small near-Earth asteroids for capture and return; the ability to implement sufficiently powerful solar electric propulsion systems to enable transportation of the captured NEA; and the proposed human presence in cislunar space in the 2020s enabling exploration and exploitation of the returned NEA. Placing a 500-t asteroid in high lunar orbit would provide a unique, meaningful, and affordable destination for astronaut crews in the next decade. This disruptive capability would have a positive impact on a wide range of the nation's human space exploration interests. It would provide a high-value target in cislunar space that would require a human presence to take full advantage of this new resource. It would offer an affordable path to providing operational experience with astronauts working around and with a NEA that could feed forward to much longer duration human missions to larger NEAs in deep space. It represents a new synergy between robotic and human missions in which robotic spacecraft would retrieve significant quantities of valuable resources for exploitation by astronaut crews to enable human exploration farther out into the solar system. The capture, transportation, examination, and dissection of an entire NEA would provide valuable information for planetary defense activities that may someday have to deflect a much larger near-Earth object. Transportation of the NEA to lunar orbit with a total flight time of 6 to 10 years would be enabled by a ~40-kW solar electric propulsion system with a specific impulse of 3,000 s. The flight system could be launched to low-Earth orbit (LEO) on a single Atlas V-class launch vehicle, and return to lunar orbit a NEA with at least 28 times the mass launched to LEO. Longer flight times, higher power SEP systems, or a target asteroid in a particularly favorable orbit could increase the mass amplification factor from 28-to-1 to 70-to-1 or greater. The NASA GRC COMPASS team estimated the full life-cycle cost of an asteroid capture and return mission at approx.$2.6B.

asteroid mining

High-Q superconducting lumped-element resonators for low-mass axion searches

Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here, we present the design and implementation of a fixed-frequency superconducting resonator operating near 250 kHz, possessing an inductor volume of ∼1 liter and achieving an unloaded quality factor Q ≈ 2.1 × 10 6 . This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.

Bosons

High Temperature Dielectric Properties and Differential Scanning Calorimetry of Lunar Simulants

To guide development of microwave process technology that could be used during in situ construction on the Moon, we measured the high-temperature basic dielectric properties (εʹ and εʺ) of 17 lunar simulants and related materials. In order to confidently use these data one needs to understand the data’s strengths and weaknesses. Therefore, a goal of this publication is to provide insights into the comparative effects of sample composition, pre-treatments, experimental variables, high temperatures, and other factors on the measured response. The dielectric measurements were performed using the cavity perturbation method over a temperature range between room temperature to 1000 °C, or higher, and provided the real and imaginary components of permittivity at six frequencies. The utility of the original values was limited by the varying density of the pellets used in the measurement. Therefore, all of the εʹ and εʺ measurements at the frequency of 2466 MHz have been scaled to a constant density, 1.75 g/cm 3 . Here the data are presented as graphs chosen to aid analysis within and across simulant groups. To gain additional insight into the processes happening at the elevated temperatures in the dielectric measurements, heat capacity data was obtained using differential scanning calorimetry (DSC) on several of the simulant materials. Our data show that over the frequency range 397 MHz – 2985 MHz a material’s behavior does not greatly change, as compared to the scale of differences observed between lunar mare and highland simulants at high temperatures. For example at 1000 °C, the mare simulant JSC-1A absorbs 10 times more power than the highland simulant NUW-LHT-5M. We observe that as melting temperatures are reached both permittivity and dielectric loss rise non-linearly, helping to explain thermal runaway during microware heating. Our data show that even less than a few weight % of many non-lunar minerals, and the use of mixtures in simulants can affect the dielectric behavior at higher temperatures. A comparison of our results with published dielectric data for Apollo samples and with remote sensing of the Moon supports the conclusion the simulants and lunar material at room temperature have very similar dielectric values.

Differential Scanning Calorimetry

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Feedstock Choices for Advancing the Bioeconomy in the US and Policy Implications

Biomass feedstocks will be critical for scaling up the bioeconomy in the United States to meet multiple demands for biofuels, sustainable aviation fuel, bioproducts, and biochemicals. There is a wide range of choices of feedstocks, including a variety of dedicated energy crops and crop residues. There are substantial differences in the yields, costs of production, and carbon intensity of these feedstocks and for each feedstock across locations. These feedstocks also differ in the trade-offs they offer among multiple environmental impacts. We discuss the economic factors that will influence the production of these feedstocks and the implications of alternative biofuel and low-carbon policies for the mix of feedstocks that will be incentivized.

Khanna, Madhu (ORCID:0000000349944451)

Sodium-sulfur battery flight experiment definition study

Sodium-sulfur batteries are considered to be one of the most likely battery systems for space applications. Compared with the Ni-H2 or Ni-Co battery systems, Na-S batteries offer a mass reduction by a factor of 2 to 4, representing significant launch cost savings or increased payload mass capabilities. The Na-S battery operates at between 300 and 400 C, using liquid sodium and sulfur/polysulfide electrodes and solid ceramic electrolyte; the transport of the electrode materials to the surface of the electrolyte is through wicking/capillary forces. This paper describes five tests identified for the Na-S battery flight experiment definition study, which include the cell characterization test, the reactant distribution test, the current/temperature distribution test, the freeze/thaw test, and the multicell LEO test. A schematic diagram of Na-S cell is included.

Chang, Rebecca

Fifth Annual Workshop on Space Operations Applications and Research (Soar 1991), Volume 1

More than 110 papers were presented at this Symposium, sponsored by the U.S. Air Force Phillips Laboratory, the University of Houston-Clear Lake, and NASA JSC. The technical areas covered were Intelligent Systems, Automation and Robotics, Human Factors and Life Sciences, and Environmental Interactions. The U.S. Air Force and NASA programmatic overviews and panel discussions were also held in each technical area. These proceedings, along with the comments and suggestions made by the panelists and keynote speakers, will be used in assessing the progress made in joint USAF/NASA projects and activities. Furthermore, future collaborative/joint programs will also be identified. The symposium proceedings includes papers covering various disciplines presented by experts from NASA, the Air Force, universities, and industry.

Mars missions

The Impact of Bias Row Noise to Photometric Accuracy: Case Study Based on a Scientific CMOS Detector

Abstract We tested a new model of CMOS detector manufactured by the Gpixel Inc, for potential space astronomical application. In laboratory, we obtain some bias images under the typical application environment. In these bias images, clear random row noise pattern is observed. The row noise also contains some characteristic spatial frequencies. We quantitatively estimated the impact of this feature to photometric measurements, by making simulated images. We compared different bias noise types under strict parameter control. The result shows the row noise will significantly deteriorate the photometric accuracy. It effectively increases the readout noise by a factor of 2–10. However, if it is properly removed, the image quality and photometric accuracy will be significantly improved.

Astronomy & Astrophysics