Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiplicity counter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Nonlinear Interactions of Alfven Waves in Multi-ion Plasmas (Final Report)

Alfven waves are of fundamental importance in magnetized plasmas, such as the solar wind and Earth’s magnetosphere. When the wave amplitude is large, nonlinear interactions among waves, such as three wave resonance, dominate the dynamics. The nonlinear process can be used as a diagnosis of the plasma composition because the composition affects the dispersion relation of Alfven waves, especially when the wave frequency is close to ion cyclotron frequencies. Previous experiments on the Large Plasma Device (LAPD) had demonstrated that the relative density of two ion species can be determined by examining nonlinear interaction of two counter-propagating Alfven waves. In this project we extended the study to a plasma with three ion species, where multiple wave bands exist, and more nonlinear interactions are possible. We also investigated the feasibility of launching two co-propagating waves to measure the ion composition. The findings of this study have implication in developing new technology to measure cold ion populations in space plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terminal-oriented computer-communication networks.

Four examples of currently operating computer-communication networks are described in this tutorial paper. They include the TYMNET network, the GE Information Services network, the NASDAQ over-the-counter stock-quotation system, and the Computer Sciences Infonet. These networks all use programmable concentrators for combining a multiplicity of terminals. Included in the discussion for each network is a description of the overall network structure, the handling and transmission of messages, communication requirements, routing and reliability consideration where applicable, operating data and design specifications where available, and unique design features in the area of computer communications.

Schwartz, M.↗

Effects of edge-localized electron cyclotron current drive on edge-localized mode suppression by resonant magnetic perturbations in DIII-D

Abstract According to recent DIII-D experiments (Logan et al 2024 Nucl. Fusion 64 014003), injecting edge localized electron cyclotron current drive (ECCD) in the counter-plasma-current (counter- I p ) direction reduces the n = 3 resonant magnetic perturbation (RMP) current threshold for edge-localized mode (ELM) suppression, while co- I p ECCD during the suppressed ELM phase causes a back transition to ELMing. This paper presents nonlinear two-fluid simulations on the ECCD manipulation of edge magnetic islands induced by RMP using the TM1 code. In the presence of a magnetic island chain at the pedestal-top, co- I p ECCD is found to decrease the island width and restore the initially degraded pedestal pressure when its radial deposition location is close to the rational surface of the island. With a sufficiently strong co- I p ECCD current, the RMP-driven magnetic island can be healed, and the pedestal pressure fully recovers to its initial ELMing state. On the contrary, counter- I p ECCD is found to increase the island width and further reduce the pedestal pressure to levels significantly below the peeling-ballooning-mode limited height, leading to even stationary ELM suppression. These simulations align with the results from DIII-D experiments. However, when multiple magnetic island chains are present at the pedestal-top, the ECCD current experiences substantial broadening, and its effects on the island width and pedestal pressure become negligible. Further simulations reveal that counter- I p ECCD enhances RMP penetration by lowering the penetration threshold, with the degree of reduction proportional to the amplitude of ECCD current. For the ∼1 MW ECCD in DIII-D, the predicted decrease in the RMP penetration threshold for ELM suppression is approximately 20%, consistent with experimental observations. These simulations indicate that edge-localized ECCD can be used to either facilitate RMP-driven ELM suppression or optimize the confinement degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent developments in parallel-grid, gas-scintillation proportional counters

The problems of developing large-area, gas-scintillation proportional counters with high resolution are considered. It is found that simple large-area, parallel-grid proportional counters suffer from a variation in gain over the counter window. Some success has been achieved in overcoming this problem by focusing the charge cloud as it drifts into the multiplication region. Measurements are reported for various mixtures of argon and xenon as well as pure xenon.

Anderson, D. F.↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ice nucleation activity of rocket effluent

An investigation was conducted concerning the ice nucleation activity of the exhaust products of solid rockets. The Voyager I and II payloads were launched from Kennedy Space Center on September 5 and August 20, 1977, respectively. A visible stabilized ground cloud (SGC) consisting of rocket effluent and dust formed downwind. An instrumented aircraft was used to make multiple passes in the SGC. A Mylar bag was rapidly filled with SGC aerosol and then immediately sampled with an ice nucleus counter. Analyses of rocket effluent collected are discussed, taking into account the ice nucleus concentration, particle concentration and size distribution, and the elemental composition of individual particles. A description of laboratory experiments is also presented, giving attention to the elemental composition of individual particles and the ice nucleus concentration.

Parungo, F. P.↗

Optical and X-ray observations of faint quasars in an optically selected sample

The confirmation of six quasars from spectrographic observations made in 1981 using the Multiple Mirror Telescope, and the characterization of 10 quasars from 1980 Einstein-Observatory X-ray observations (using both imaging proportional counter and high-resolution imager), are reported. The candidates had been selected by Formiggini et al. (1980) in a 1.72-sq-deg region centered on 13h 6 deg, on the basis of ultraviolet excess and a limiting B magnitude of 19.20. A total sample of 10 UV-excess quasars of this magnitude has now been confirmed, for an integral surface density of 5.8 + or - 1.8 per sq deg. Confirmation of three objects from another sample with B less than 18.25 as quasars yielded a surface density of 0./59 + or - 0.13 per sq deg at that magnitude. Data from the complete samples were used to compute the number-flux relation, found to be described by a power law with a 2.25 index for quasars with B between 17.0 and 19.2. From the X-ray observations it was determined that quasars with z less than 2.2 and B less than 19.20 contribute about 15 percent to the cosmic 2-keV background.

Marshall, H. L.↗

Capacitor-type micrometeoroid detectors

The metal oxide semiconductor (MOS) capacitor micrometeroid detector consists of a thin dielectric capacitor fabricated on a silicon wafer. In operation, the device is charged to a voltage level sufficiently near breakdown that micrometeoroid impacts will cause dielectric deformation or heating and subsequent arc-over at the point of impact. Each detector is capable of recording multiple impacts because of the self-healing characteristics of the device. Support instrumentation requirements consist of a voltage source and pulse counters that monitor the pulse of recharging current following every impact. An investigation has been conducted in which 0.5 to 5 micron diameter carbonized iron spheres traveling at velocities of 4 to 10 Km/sec were impacted on to detectors with either a dielectric thickness of 0.4 or 1.0 micron. This study demonstrated that an ion microprobe tuned to sufficiently high resolution can detect Fe remaining on the detector after the impact. Furthermore, it is also possible to resolve Fe ion images free of mass interferences from Si, for example, giving its spatial distribution after impact. Specifically this technique has shown that significant amounts of impacting particles remain in the crater and near it which can be analyzed for isotopic content. Further testing and calibration could lead to quantitive analysis. This study has shown that the capacitor type micrometeroid detector is capable of not only time and flux measurements but can also be used for isotopic analysis.

Wortman, J. J.↗

Observations of Counter-Streaming Ion Velocity Distributions in LLBL

We analyze ion velocity distributions observed by Interball-Tail at two LLBL crossings under southward and variable magnetosheath magnetic field. These magnetic conditions lead to highly structured LLBL. D-shape ion velocity distributions were observed within LLBL structures along with other reconnection signatures. Another type of the ion velocity distributions observed within LLBL structures consists of two counter-streaming magnetosheath-type components. We consider two possible scenarios that may lead to development of these counterstreaming ion components: reflection of transmitted magnetosheath ions from the ionosphere and creation of these velocity distributions during formation of the LLBL. We argue that observed counter-streaming component could not be due to ionospheric reflection. The observations of these ion velocity distributions are in favor of the multiple reconnections between magnetosheath and magnetospheric flux tubes.

Vaisberg, O. L.↗

Energy spectrum of medium energy gamma-rays from the galactic center region

A balloon-borne magnetic core digitized spark chamber with two assemblies of spark-chambers above and below the scintillation counters was used to measure the medium energy gamma ray flux from the galactic center region. Gamma ray calculations are based on the multiple scattering of the pair electrons in 15 aluminum plates interleaved in the spark chamber modules. Counting rates determined during ascent and at ceiling indicate the presence of diffuse component in this energy range. Preliminary results give an integral flux between 15 and 70 MeV compared to the differential points in other results.

Palmeira, R. A. R.↗

Photonic Switching Devices Using Light Bullets

A unique ultra-fast, all-optical switching device or switch is made with readily available, relatively inexpensive, highly nonlinear optical materials. which includes highly nonlinear optical glasses, semiconductor crystals and/or multiple quantum well semiconductor materials. At the specified wavelengths. these optical materials have a sufficiently negative group velocity dispersion and high nonlinear index of refraction to support stable light bullets. The light bullets counter-propagate through, and interact within the waveguide to selectively change each others' directions of propagation into predetermined channels. In one embodiment, the switch utilizes a rectangularly planar slab waveguide. and further includes two central channels and a plurality of lateral channels for guiding the light bullets into and out of the waveguide. An advantage of the present all-optical switching device lies in its practical use of light bullets, thus preventing the degeneration of the pulses due to dispersion and diffraction at the front and back of the pulses. Another advantage of the switching device is the relative insensitivity of the collision process to the time difference in which the counter-propagating pulses enter the waveguide. since. contrary to conventional co-propagating spatial solitons, the relative phase of the colliding pulses does not affect the interaction of these pulses. Yet another feature of the present all-optical switching device is the selection of the light pulse parameters which enables the generation of light bullets in nonlinear optical materials. including highly nonlinear optical glasses and semiconductor materials such as semiconductor crystals and/or multiple quantum well semiconductor materials.

Goorjian, Peter M.↗

HSNMon: High-Speed Monitoring Software for Omni-Path

HSNMon is a robust high speed network monitoring daemon that provides insight into network availability, hardware failure, and network performance for switches and network cards. HSNMon collects counters, forwarding tables, and error information at high resolution using publicly available Omni-Path Management APIs. The collected data can be forwarded into multiple logging infrastructures including syslog and message queuing systems. HSNMon is only the infrastructure for collecting the network data. It does not include any collected data or proprietary LANL information

Holman, Brett↗

Efficacy of compression of different capacitance beds in the amelioration of orthostatic hypotension

Orthostatic hypotension (OH) is the most disabling and serious manifestation of adrenergic failure, occurring in the autonomic neuropathies, pure autonomic failure (PAF) and multiple system atrophy (MSA). No specific treatment is currently available for most etiologies of OH. A reduction in venous capacity, secondary to some physical counter maneuvers (e.g., squatting or leg crossing), or the use of compressive garments, can ameliorate OH. However, there is little information on the differential efficacy, or the mechanisms of improvement, engendered by compression of specific capacitance beds. We therefore evaluated the efficacy of compression of specific compartments (calves, thighs, low abdomen, calves and thighs, and all compartments combined), using a modified antigravity suit, on the end-points of orthostatic blood pressure, and symptoms of orthostatic intolerance. Fourteen patients (PAF, n = 9; MSA, n = 3; diabetic autonomic neuropathy, n = 2; five males and nine females) with clinical OH were studied. The mean age was 62 years (range 31-78). The mean +/- SEM orthostatic systolic blood pressure when all compartments were compressed was 115.9 +/- 7.4 mmHg, significantly improved (p < 0.001) over the head-up tilt value without compression of 89.6 +/- 7.0 mmHg. The abdomen was the only single compartment whose compression significantly reduced OH (p < 0.005). There was a significant increase of peripheral resistance index (PRI) with compression of abdomen (p < 0.001) or all compartments (p < 0.001); end-diastolic index and cardiac index did not change. We conclude that denervation increases vascular capacity, and that venous compression improves OH by reducing this capacity and increasing PRI. Compression of all compartments is the most efficacious, followed by abdominal compression, whereas leg compression alone was less effective, presumably reflecting the large capacity of the abdomen relative to the legs.

Non-NASA Center↗

Surface diffusion manifestation in electrodeposition of metal anodes

Metal anode-based battery systems have been deemed indispensable towards energy storage renaissance engendering extensive research into strategies countering dendritic growth of metal electrodeposition. Fundamentally, the morphological evolution of a material is uniquely characterized by the heights of its self-diffusion barrier across multiple pathways. Herein, based on a coarse-grained kinetic Monte Carlo method, we derive insights into the nucleation and growth of metallic electrodeposits in liquid electrolytes, governed by surface self-diffusion characteristics cognizant of the diverse diffusion routes including terrace, away from step and interlayer pathways. We deconvolve the roles played by each of these surface diffusion mechanisms in conjunction with the electrochemical reaction rate on the deposition morphology regime (film vs. mossy vs. fractal). We identify interlayer diffusion as the predominant morphology-determining mechanism; dendrite-free deposition even at moderate current rates constrains this diffusion barrier to an upper limit. Additionally, we highlight subtle features amidst the realm of the morphological growth assortment that connect to the cell's electrochemical performance. Finally, we delineate morphological features of Li, Na, Mg and Al based on their respective surface diffusion barriers and applied overpotentials, and provide a baseline for the interpretation of experimental observations. This fundamental study sheds light on the mesoscale underpinnings of morphological variances in mono-valent and multi-valent metal electrodeposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An investigation of high-multiplicity gamma events in pp collisions with c.m. energies between 22 and 62 GeV

An experiment was conducted at the CERN intersecting storage rings using colliding proton beams to investigate high-multiplicity gamma-ray events. The objective of the study was to reveal certain features of multiple pion production as well as other possible mechanisms of gamma-ray production. The detector system consisted of ten planes of spark chambers, three scintillation counter hodoscopes and two arrays of lead-glass Cerenkov counters, the first array containing 16 counters and the second, 60 counters. The event trigger was obtained from the Cerenkov counters, and the energies in all the Cerenkov counters after trigger, as well as the information on all the charged particles given by the scintillation counters and spark chambers were recorded on magnetic tape. The relationship between the number of gamma-rays per event and the number of Cerenkov counters triggered by a neutral secondary was established by means of a Monte Carlo calculation.

Dell, G. F.↗

VHF Wide-Band, Dual-Polarization Microstrip-Patch Antenna

The figure depicts selected aspects of a very-high-frequency (VHF) microstrip patch antenna designed and built to satisfy requirements specific to an airborne synthetic-aperture radar system for measuring the thickness of sea ice. One of the requirements is that the antenna be capable of functioning over the relatively wide frequency band of 127 to 172 MHz corresponding to a fractional bandwidth of about 30 percent relative to a nominal mid-band frequency of 149.5 MHz. Another requirement is that the antenna be capable of functioning in either or both of two orthogonal linear polarizations. In addition, the antenna is required to be as compact and lightweight as possible. In a basic design according to generally accepted microstrip-patch-antenna engineering practice, one would ordinarily use a relatively thick dielectric substrate and multiple feed probes to obtain the desired combination of wide-band and dual-polarization capabilities. However, the combination of a thick substrate and multiple feeds would give rise to higher-order electromagnetic nodes, thereby undesirably contributing to cross polarization and to reduction of the isolation between feed probes. To counter these adverse effects while satisfying the requirements stated above, the design of this antenna incorporates several improvements over the basic design.

Huang, John↗

Evaluated 238 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 238 U from 800 keV to MeV. This evaluation had to be re-done from “scratch” as the input to previous $\overline{v}_p$ evaluations, specifically ENDF/B-VIII.0, was not found. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. The new evaluated 238 U $\overline{v}_p$ based on only experimental data differs distinctly from ENDF/B-VIII.0 $\overline{v}_p$ from 2 to 4.5 MeV, and from 6 to 7 MeV, and is otherwise similar. The difference from 2 to 4.5 MeV stems from the fact that ENDF/B-VIII.0 was tweaked in this energy range to data of Frehaut, while two other, equally trustworthy, data sets would indicate an evaluated 238 U $\overline{v}_p$ that is up to 2% higher. Also, second chance fission in ENDF/B-VIII.0 was smoothed over from 6–7 MeV. Another major difference to ENDF/B-VIII.0 is that one of the evaluations presented here includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to validate the new 238 U $\overline{v}_p$ by using CGMF parameters obtained from fitting to experimental 238 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data for some observables, but are farther away from experimental data related to TKE observables. In addition to that, the evaluated 238 U(n,f) $\overline{v}_p$ shows similar deviations from ENDF/B-VIII.0 as for the evaluation with only experimental data. This difference is expected to lead to changes in simulated effective neutron multiplication factor, $k_{eff}$ of ICSBEP critical assemblies that are sensitive to 238 U in the fast range (BigTen, Flattop, Flattop-Pu). These changes in $k_{eff}$ need to be counter-balanced. Chi-Nu PFNS experimental data are expected to be released in the next few months that might lead to the needed changes in the PFNS. Until then, we hold off in benchmarking the new 238 U(n,f) $\overline{v}_p$ as well as submitting it to ENDF/B-VIII.1. Also, new high-precision 238 U $\overline{v}_p$ are expected to be measured by the CEA in the next two years that will shed further light on question on 238 U $\overline{v}_p$ from 2–4.5 and 6–7 MeV.

238U↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗