Aging mechanisms of filled cross-linked polyethylene (XLPE) cable insulation material exposed to simultaneous thermal and gamma radiation

Thermal and simultaneous thermal and gamma radiation aging experiments were conducted on an industry grade cross-linked polyethylene (XLPE) cable insulation material, which is a composite material with XLPE as polymer matrix and various additives and fillers. Reverse engineering was conducted to identify and quantify the material composition given that this information was not revealed by the cable manufacture. Samples were then aged at temperatures of 60, 90, and 115 °C, exposed to gamma radiation for total doses of 0 to 324 kGy, and at dose rates of 0 to 540 Gy/h. Aging mechanisms were studied using various materials characterization techniques including pyrolysis gas chromatography mass spectrometry (Py-GCMS), differential scanning calorimetry (DSC), nuclear magnetic resonance spectroscopy (NMR), and gel-fraction tests. Results show that the flame-retardant components were decomposed into smaller molecules when the material was exposed to gamma radiation, while no changes were observed when the samples were aged thermally without gamma radiation. With exposure to gamma radiation, the crystalline phase of the XLPE were damaged by gamma radiation introducing defects in the crystals, resulting in smaller and less perfect crystals. The dominance of chain scission or chain reformation process largely depends on the chain mobility, which is decided by the aging temperature. Chain scission was seen to dominate when the material was exposed to gamma radiation at 60 °C. Chain cross-linking slightly dominated when the material was exposed to gamma radiation at 90 °C and became more dominant with exposure to gamma radiation at 115 °C. No significant change to the XLPE polymer matrix was observed when the samples were exposed to thermal aging without gamma radiation. Finally, antioxidant is more effective in protecting the XLPE polymer matrix under thermal aging, but less effective with sample exposure to gamma radiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Temperature-Following Thermal Barrier Coatings for High Efficiency Engines (Final Report)

HRL Laboratories and General Motors (GM), pursued this effort to increase the efficiency of internal combustion engines (ICEs) by developing and implementing temperature-following thermal barrier coatings (TBCs) to decrease heat loss from the combustion chamber. HRL developed microsphere TBCs based on hollow high-temperature alloy spheres with average diameter of 50 μm and wall thickness ~1 μm (microspheres) that achieve unprecedented low thermal conductivity and heat capacity (10X lower than the state of the art) while offering exceptional environmental and mechanical resistance.> In current ICEs, approximately 29% of the fuel’s energy is lost to the cooling system and about 22% goes into moving the car. By limiting heat losses from the combustion chamber with insulating coatings, fuel energy can be redirected into additional piston work and into the exhaust stream. The additional energy that goes into the exhaust stream can be turned into useful work through the use of an exhaust energy recovery device, such as turbocompounding and/or through driving a turbocharger to increase the power density of the engine allowing downsizing. Insulating coatings for piston crowns have been pursued in the past, but previous materials—typically ceramics—exhibited low thermal conductivity but retained high heat capacity. Such materials reduce heat losses but stabilize at a high surface temperature. The high surface temperature heats the incoming gases, which lowers volumetric efficiency and increases propensity for knock, resulting in degraded engine performance. This program developed an innovative new material that combines low thermal conductivity with low heat capacity. These unique properties allow it to follow rapid changes in gas temperature during each combustion cycle. A metallic microsphere TBC has been demonstrated that exhibits increased surface temperature during the combustion period, resulting in reduced heat transfer losses, while still returning to a low surface temperature during the gas exchange period. A 10X lower thermal conductivity and heat capacity than state-of-the-art thermal barrier coatings has been demonstrated. These unprecedented thermal properties are achieved through the coating architecture, which consists of closed pores on the microscale and exhibits a total porosity of 90% to 95%. By selecting a high-temperature nickel alloy as the coating material, the ductility and strength of metals can be harnessed to achieve much better durability and damage tolerance than brittle ceramic coatings can achieve.

33 ADVANCED PROPULSION SYSTEMS↗

Stabilization of Preternatural Barium Oxidation States as an Unexpected Byproduct of β-Decay: Discovery of a New Halide Semiconductor Alloy

137 Cs has a wide range of roles in the nuclear industry. The solid material, safely encapsulated in CsCl as 137 CsCl, is stored as fission product waste from nuclear power production and legacy waste from nuclear weapons production; it has also served as a radiation source in food and sewage irradiators as well as medical devices. However, because of the solubility of the chloride salt and the relatively high specific activity of 137 Cs, damaged or broken capsules can lead to severe radiological accidents. Safe capsule design and material recycling are complicated by the unclear structural evolution during β-decay, which remains ambiguous due to the differing oxidation states of Cs (1+) and Ba (2+). Here, in this study, we use first-principles calculations to investigate the evolving structure–property relationships of Cs 1–x Ba x Cl during β-decay. Despite the well-established 2+ formal oxidation state of alkali-earth metals, we find that Ba 1+ can be stabilized in the form of a mixed-valence alloy at low concentrations. Specifically, we identify three regimes for the β-decay of 137 Cs into CsCl: Ba-doped CsCl (Ba ≤ 14%), wherein Ba has the expected 2+ oxidation state; Cs–Ba–Cl alloys, where Ba has a mix of the usual Ba 2+ and highly unusual Ba 1+ oxidation state in the form of a quasi-disordered mixed-valence alloy (Ba = 25%); and phase separation into a CsCl + BaCl 2 + Ba (m) mechanical mixture, where Ba reverts to its expected 2+ oxidation state (Ba > 25%). Surprisingly, the Cs 0.75 Ba 0.25 Cl mixed-valence alloy is a narrow indirect band gap semiconductor (1.05 eV) despite the insulating nature of both CsCl and BaCl 2 . It also exhibits strongly excitonic polarized optical properties, has glass-like ultralow thermal conductivity (directional average of 0.21 W/mK at 300 K), and shows greater resistance to deformation under both tensile and volumetric strengths compared with the original CsCl structure (e.g., shear and Young’s modulus of 9.04 and 31.62 GPa, respectively). These findings imply that transmutation of 137 Cs leads to highly unusual chemical bonding that stabilizes Ba 1+ in local regions of the quasi-disordered Cs 0.25 Ba 0.75 Cl, resulting in anomalous physical properties. Moreover, this discovery provides valuable insight for safe nuclear waste capsule design, which can aid in preventing environmental or human exposure to radioactive materials.

Fuhr, Addis S. [Oak Ridge National Laboratory (ORN↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

Specific iron binding to natural sphingomyelin membrane induced by non-specific co-solutes

Sphingomyelin (SPM), a crucial phospholipid in the myelin sheath, plays a vital role in insulating nerve fibers. We hypothesize that iron ions selectively bind to the phosphatidylcholine (PC) template within the SPM membrane under near-physiological conditions, resulting in disruptions to membrane organization. These interactions could potentially contribute to the degradation of the myelin sheath, thereby playing a role in the development of neurodegenerative diseases. We utilized synchrotron-based X-ray spectroscopy and diffraction techniques to study the interaction of iron ions with a bovine spinal-cord SPM monolayer (ML) at the liquid-vapor interface under physiological conditions. The SPM ML serves as a model system, representing localized patches of lipids within a more complex membrane structure. The experiments assessed iron binding to the SPM membrane both in the presence of salts and with additional evaluation of the effects of various ion species on membrane behavior. Grazing incidence X-ray diffraction was employed to analyze the impact of iron binding on the structural integrity of the SPM membrane. Furthermore, our results demonstrate that iron ions in dilute solution selectively bind to the PC template of the SPM membrane exclusively at near-physiological salt concentrations (e.g., NaCl, KCl, KI, or CaCl 2 ) and are pH-dependent. In-significant binding was detected in the absence of these salts or at near-neutral pH with salts. The surface adsorption of iron ions is correlated with salt concentration, reaching saturation at physiological levels. In contrast, multivalent ions such as La 3+ and Ca 2+ do not bind to SPM under similar conditions. Notably, iron binding to the SPM membrane disrupts its in-plane organization, suggesting that these interactions may compromise membrane integrity and contribute to myelin sheath damage associated with neurological disorders.

59 BASIC BIOLOGICAL SCIENCES↗

Frequency Domain Reflectometry (FDR) Simulation Techniques for Digital Twin Representation of an Electrical Cable

Simulation of cable system response to frequency domain reflectometry (FDR) tests can be instrumental to understanding these tests and the nature and influence of various cable anomalies on test signatures. Reflectometry simulations are based upon a finite element representation of cable conductors and insulation to produce an S-parameter at each evaluated frequency. The aggregate collection of cable model S-parameters can simulate the influence on a test signal injected into a physical cable. Such an approach was undertaken in this work to produce a digital twin simulation of a low-voltage electrical cable. The electrical cable digital twin examined the influence of test simulation parameters and the relative influence of cable anomalies, including thermal aging, water or moisture exposure, water or moisture ingress, and other anomalies. The digital twin in this work included modeling of the conductors, insulation, jacket, and surrounding environment (air, water, etc.). The digital twin could be expanded to include cable bends, junctions and splices, branch or T systems, and termination impedances of motors or instruments. Observations and conclusions of this work include: 1. Fully 3D digital twin simulation of an electrical cable using an FDR approach is possible. However, there are tradeoffs between simulation fidelity and solution time, which must be balanced to ensure the simulation solves in an adequate amount of time (e.g., less than 20 minutes). Simulation parameters to balance include frequency bandwidth, number of frequencies, mesh density, connection impedance, and permittivity tolerance. 2. The digital twin simulation can explain FDR sensitivity to various cable anomalies, including entry and exit from an oven or water bath. 3. The digital twin simulation FDR response attenuates with distance along the cable and is further affected by the frequency bandwidth, which is similar to that observed with physical measurements. 4. The resolution of the digital twin FDR peaks increased with increasing bandwidth and with increasing number of frequencies, again similar to physical measurements. 5. The presence of multiple anomalies in the digital twin does not substantially attenuate the FDR response to anomalies located beyond the first encountered anomaly and impedance mismatch. 6. Spectral variation of the permittivity did not have a significant effect on the FDR response compared to a fixed nominal value. 7. Extension of the digital twin to 1000 ft still allowed for detection of distal anomalies near the far end of the electrical cable from the instrument connection point. 8. The ARENA test bed facilitates efficient NDE evaluations of well understood cable anomalies with various NDE methods without risking actual plant damage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Functional Photoresists for Energy Applications. Final Report

Monolithic ultralow-density porous bulk materials have recently attracted much interest due to many emerging applications in the areas of catalysis, energy storage and conversion, and thermal insulation. They are also important components of high energy density (HED) and inertial confinement fusion (ICF) targets. However, despite tremendous progress that has been made in the synthesis of porous materials, deterministic and independent control over microscopic architecture, density and composition remain key issues, and their integration in high precision devices requires cost and time-intensive mechanical machining that not only reduces reproducibility by generating debris but also limits the complexity of the 3D shapes that can be realized. In this project, we overcame these limitations by developing a universal templating capability that provides deterministic and independent control over density, composition, architecture, and macroscopic sample shape. This was achieved by developing the technology to 1) 3D print ultrahigh resolution, ultra-high precision polymeric micro-lattice templates, 2) coat these templates with the desired materials, and 3) removing the template (Fig. 1a). Atomic layer deposition (ALD) provides the atomic scale coating thickness accuracy required for precisely controlling density. While this templating approach had been demonstrated in prior work, limitations in suitable photoresists, 3D print technologies, print design, and template removal techniques did not allow the fabrication of millimeter-sized high-precision parts with sub-micron resolution. To enable this technology, we developed 1) two-photon polymerization (TPP) print designs that enable the fabrication of millimeter-sized, mechanically robust polymeric templates with sub-micron resolution and 2) a continuum level TPP printing simulation capability for additional print design guidance; 3) atomistic models to study photoresist polymerization kinetics and network topography, 4) refractive index matched polymeric and preceramic TPP photoresists, and 5) functional TPP photoresists including porous voxel structures and self-immolative polymer photoresist chemistries; and 6) damage free template removal techniques that enable the fabrication of defect-free high-precision low-density foam components. We also developed a templating approach for pure carbon microlattices with a unique tube-in-tube ligament morphology. As a test platform, we pursued the fabrication of foam liners that promise to further increase the neutron yield in indirect drive ICF experiments by improving implosion symmetry control and coupling between the laser and the deuterium-tritium fuel. This application requires fabrication and integration of a ultra-high precision, millimeter-sized, thin-walled (200-400 micrometer thick), low-density (10-30 mg/cc), high atomic number (high Z) cylindrical foam tube into the gold hohlraum of an indirect drive ICF target (Fig. 1b). While our hohlraum liner test case will mainly find application in HED and ICF experiments, the underlying science will also directly apply to previously developed nanoparticle and additive manufacturing technologies and will advance those techniques as well.