Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurements of the ionization efficiency of protons in methane

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears “quenched” compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below 50 keV ), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV , with kinetic energies in between 2 keV and 13 keV in 100 mbar of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as a reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by IQF (E K )=E$^α_K$ / (β+E$^α_K$) with α=0.70±0.08 and β=1.32±0.17 . In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching 33% at 2 keV .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of nanodiamond photocathodes for MPGD-based detectors of single photons

The proposed new Electron–Ion Collider poses a technical and intellectual challenge for the detector design to accommodate the long-term diverse physics goals envisaged by the program. This requires a 4π detector system capable of reconstructing the energy and momentum of final state particles with high precision. The Electron-Ion Collider also requires identification of particles of different masses over a wide momentum range. A diverse spectrum of Particle IDentification detectors has been proposed. Of the four types of detectors for hadron identification, three are based on Ring Imaging Cherenkov Counter technologies, and one is realized by the Time of Flight method. The quest for a novel photocathode, sensitive in the far vacuum ultraviolet wavelength range and more robust than cesium iodide, motivated an R&D programme to explore nano-diamond (ND) based photocathodes, started by a collaboration between INFN and CNR Bari and INFN Trieste. Systematic measurements of the photoemission in different Ar:CH 4 and Ar:CO 2 gas mixtures with various types of ND powders and Hydrogenated ND (H-ND) powders are reported. A first study of the response of THGEMs coated with different photocathode materials is presented. Additionally, the progress of this R&D programme and the results obtained so far by these exploratory studies are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using cyclotron radiation emission for ultra-high resolution x-ray spectroscopy

Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.

07 ISOTOPE AND RADIATION SOURCES↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype X-ray and Gamma Detection with Cyclotron Radiation Emission Spectroscopy

Cyclotron radiation emission spectroscopy, or CRES, is a novel approach to measuring the energy of an electron. By trapping a free electron in a high magnetic field, it undergoes cyclotron motion and emits radiofrequency (RF) waves. The frequency of this RF radiation is directly related to the energy of the electron. Because many cycles of the RF emission are recorded, the energy resolution of the CRES system is on the order of a single electron volt. To make a CRES system sensitive to photons, a target gas is used to induce a photoelectric effect, producing the electron that is subsequently trapped. By adding the binding energy of the target atom, the energy of the incident photon may be reconstructed. Using a xenon target gas, photoelectric interactions dominate up to approximately 300 keV, covering not only all atomic shell X-rays of the elements, but many low-lying nuclear states as well, including key transuranic elements related to nuclear security. CRES holds the potential of maintaining single-eV resolution up to this 300-keV range, thereby surpassing current state-of-the-art detectors by a factor of 10-100. The instrumental resolution of the system is limited by the uniformity of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-loss Si-based Dielectrics for High Frequency Components of Superconducting Detectors

Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The film's morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.

low-loss dielectrics↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]↗

Sensitivity of the NEXT experiment to Xe-124 double electron capture

Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2$\nu$EC EC) has been predicted for a number of isotopes, but only observed in 78 Kr, 130 Ba and, recently, 124 Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0$\nu$EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124 Xe 2$\nu$EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2$\nu$EC EC signal and real data from NEXT-White operated with 124 Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124 Xe and for a 5-year run, a sensitivity to the 2$\nu$EC EC half-life of 6 × 10 22 y (at 90% confidence level) or better can be reached.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation modes of the KATRIN experiment Tritium Loop System using 83m Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83m Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83m Kr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83m Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83m Kr-rates, gas densities, and gas compositions inside the WGTS.

47 OTHER INSTRUMENTATION↗

Spatially and temporally resolved plasma parameter estimations of laser heated MagLIF relevant gas pipes at NIF

The ability to control laser pre-heat is an integral part of the inertial confinement fusion concept known as Magnetized Liner Inertial Fusion. This process is studied at the National Ignition Facility (NIF) where 4 of the 192 laser beams are propagated through a 1-cm long gas cell where they deposit >20 kJ of energy into the gaseous fuel via inverse bremsstrahlung absorption. This process ionizes the gas, producing a plasma that follows behind the laser front and expands over the radius of the cell. Emission from this plasma, as viewed by a gated x-ray detector, can be used to build spatially and temporally resolved estimations of the pre-heat plasma's density and temperature profiles. This can then be used to estimate the plasma pressure, internal energy, and radiation losses. Estimations show the evolution of the plasma in magnetized and unmagnetized gas cells filled with ambient temperature neopentane (C5H12) +1% Ar, as well as unmagnetized cryogenically cooled (32 K) deuterium +1% Ne filled targets. This analysis shows the effects of initial gas-fill density, composition, and axial magnetization on the time-dependent plasma parameters. Previously, these parameters at the NIF had not been experimentally characterized, and these estimations provided a potential new means of testing radiation magneto-hydrodynamic predictive capability models. Results in unmagnetized targets have strong agreement with simulations. However, in targets with a 19 T applied axial magnetic field, this method yields electron temperatures up to 100% hotter than those predicted by HYDRA codes.

Bremsstrahlung↗

The VMM3a ASIC

The VMM3a is a custom low-noise Application Specific Integrated Circuit. It is intended to be used in the front end readout electronics of both the Micromegas and sTGC detectors of the ATLAS New Small Wheels upgrade project at CERN. It is fabricated in the 130 nm GlobalFoundries 8RF-DM process. Here, the 64 channels with highly configurable parameters, although designed for a specific project, can meet the processing needs of signals from various detector types in several other applications. In this note, the VMM3a, which is the production version of the VMM family, will be presented along with the features incorporated and its performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural and electronic switching of a single crystal 2D metal-organic framework prepared by chemical vapor deposition

The incorporation of metal-organic frameworks into advanced devices remains a desirable goal, but progress is hindered by difficulties in preparing large crystalline metal-organic framework films with suitable electronic performance. We demonstrate the direct growth of large-area, high quality, and phase pure single metal-organic framework crystals through chemical vapor deposition of a dimolybdenum paddlewheel precursor, Mo 2 (INA) 4 . These exceptionally uniform, high quality crystals cover areas up to 8600 µm 2 and can be grown down to thicknesses of 30 nm. Moreover, scanning tunneling microscopy indicates that the Mo 2 (INA) 4 clusters assemble into a two-dimensional, single-layer framework. Devices are readily fabricated from single vapor-phase grown crystals and exhibit reversible 8-fold changes in conductivity upon illumination at modest powers. Moreover, we identify vapor-induced single crystal transitions that are reversible and responsible for 30-fold changes in conductivity of the metal-organic framework as monitored by in situ device measurements. Gas-phase methods, including chemical vapor deposition, show broader promise for the preparation of high-quality molecular frameworks, and may enable their integration into devices, including detectors and actuators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗