Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostic procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Diagnostics of Magnetohydrodynamic Modes in the Interstellar Medium through Synchrotron Polarization Statistics

One of the biggest challenges in understanding magnetohydrodynamic (MHD) turbulence is identifying the plasma mode components from observational data. Previous studies on synchrotron polarization from the interstellar medium (ISM) suggest that the dominant MHD modes can be identified via statistics of Stokes parameters, which would be crucial for studying various ISM processes such as the scattering and acceleration of cosmic rays, star formation, and dynamo. In this paper, we present a numerical study of the synchrotron polarization analysis (SPA) method through systematic investigation of the statistical properties of the Stokes parameters. We derive the theoretical basis for our method from the fundamental statistics of MHD turbulence, recognizing that the projection of the MHD modes allows us to identify the modes dominating the energy fraction from synchrotron observations. Based on the discovery, we revise the SPA method using synthetic synchrotron polarization observations obtained from 3D ideal MHD simulations with a wide range of plasma parameters and driving mechanisms, and present a modified recipe for mode identification. We propose a classification criterion based on a new SPA+ fitting procedure, which allows us to distinguish between Alfvén mode and compressible/slow mode dominated turbulence. We further propose a new method to identify fast modes by analyzing the asymmetry of the SPA+ signature and establish a new asymmetry parameter to detect the presence of fast mode turbulence. Additionally, we confirm through numerical tests that the identification of the compressible and fast modes is not affected by Faraday rotation in both the emitting plasma and the foreground.

97 MATHEMATICS AND COMPUTING↗

Image processing methods for Rayleigh scattering measurements of diesel spray mixing at high repetition rate

This work describes the diagnostic implementation and image processing methods to quantitatively measure diesel spray mixing injected into a high-pressure, high-temperature environment. We used a high-repetition-rate pulse-burst laser developed in-house, a high-speed CMOS camera, and optimized the optical configuration to capture Rayleigh scattering images of the vaporized fuel jets inside a constant volume chamber. The experimental installation was modified to reduce reflections and flare levels to maximize the images’ signal-to-noise ratios by anti-reflection coatings on windows and surfaces, as well as series of optical baffles. Because of the specificities of the high-speed system, several image processing techniques had to be developed and implemented to provide quantitative fuel concentration measurements. We find that these methods involve various correction procedures such as camera linearity, laser intensity fluctuation, dynamic background flare, as well as beam-steering effects. Image inpainting was also applied to correct the Rayleigh scattering signal from large scatterers (e.g. particulates). The experiments demonstrate that applying planar laser Rayleigh scattering at high repetition rate to quantitatively resolve the mixing of fuel and ambient gases in diesel jets is challenging, but possible. The thorough analysis of the experimental uncertainty and comparisons to past data prove that such measurements can be accurate, whilst providing valuable information about the mixing processes of high-pressure diesel jets.

47 OTHER INSTRUMENTATION↗

Characterization of a new ultra-high pressure shock tube facility for combustion and propulsion studies

A new shock tube facility has been designed, constructed, and characterized at the University of Central Florida. This facility is capable of withstanding pressures of up to 1000 atm, allowing for combustion diagnostics of extreme conditions, such as in rocket combustion chambers or in novel power conversion cycles. For studies with toxic gas impurities, the high initial pressures required the development of a gas delivery system to ensure the longevity of the facility and the safety of the personnel. Data acquisition and experimental propagation were implemented with remote access to ensure safety, paired with a LabVIEW- and Python-based user interface. Thus far, test pressures of 270 atm, blast pressures of 730 atm, and temperatures approaching 10 000 K have been achieved. The extreme limitations of this facility allow for emission spectroscopy to be performed during the oxidation of fuel mixtures, e.g., alkanes diluted in argon and carbon dioxide. Ignition delay times were determined and compared to simulations using chemical kinetic mechanisms. The design, experimental procedures, processes of analysis, and uncertainty determination are outlined, and typical pressure profiles are compared with a new gas dynamics solver and empirical correlations developed across multiple shock tube facilities. Preliminary reactive mixture analyses are included with further investigation of the mixtures outlined.

47 OTHER INSTRUMENTATION↗

Use of Stable Mercury Isotopes to Assess Mercury and Methylmercury Transformation and Transport across Critical Interfaces from the Molecular to the Watershed Scale (Final Report)

This project titled “Use of Stable Mercury Isotopes to Assess Mercury and Methylmercury Transformation and Transport across Critical Interfaces from the Molecular to the Watershed Scale” represents a collaborative effort between the University of Michigan (Jason Demers, PI) and Oak Ridge National Laboratory (Scott Brooks, co-I). Much has been learned about mercury (Hg) cycling in stream ecosystems, and East Fork Poplar Creek (EFPC) in particular, through decades of previous research. Nevertheless, some of the most fundamental questions regarding the sources of bioavailable Hg and its transformation to toxic methylmercury (MeHg) have remained unanswered. These fundamental questions include: (1) what are the sources and biogeochemical processes that lead to the input of dissolved Hg to stream water across critical subsurface interfaces within stream ecosystems, and EFPC in particular? and (2) what are the sources and biogeochemical processes that control the production and fate of bioaccumulative MeHg within stream ecosystems, and in EFPC in particular? To address these fundamental questions, our project aimed to couple laboratory experiments and field observations, both utilizing natural abundance Hg stable isotope techniques, to identify the processes responsible for generating mobile, bioavailable dissolved Hg from recalcitrant legacy sources within critical subsurface zones (e.g., streambed hyporheic zone, riparian floodplain subsurface). We used the isotopic signature of this bioavailable dissolved Hg to track its mobilization across these critical interfaces in order to link diffuse subsurface sources of dissolved Hg with increases in surface water dissolved Hg flux measured at the watershed scale. Additionally, our research aimed to determine the isotopic composition of MeHg within these same critical subsurface zones. We directly assessed the isotopic composition of MeHg within biota in order to gain insight into which subsurface sources of inorganic Hg and toxic MeHg are available for bioaccumulation within the EFPC ecosystem. Net fluxes of dissolved Hg along the flow path of EFPC were shown to vary spatially and temporally. In the Upper EFPC, within the Y12 boundary, stream water flux of dissolved Hg consistently decreased between the outfall and the downstream boundary of Y12 (57% ± 29%, 1SD). Within the Upper EFPC, an assessment of Hg isotopic composition suggested that losses were strongly reaction-driven, although isotopic diagnostics did not conform to any known processes. Downstream of Y12, in the upper reach of the Lower EFPC, dissolved Hg fluxes tended to increase during the dormant season (net gain of 11-120%), and decrease during the growing season (net loss of 23% +/- 18%, 1SD). In the downstream-most reach of Lower EFPC, dissolved Hg fluxes increased by 12-108% in 9 out of 10 monthly assessments. Overall, diffuse fluxes from the non-Y12 watershed accounted for 34% (+/- 17%, 1SD) of all dissolved Hg exported during base flow. Within Lower EFPC, an assessment of Hg isotopic composition was consistent with the contribution of diffuse Hg inputs from high-concentration hotspots within riparian floodplains and streambed hyporheic pore water. To investigate remobilization of recalcitrant Hg from legacy sediment sources, we developed procedures that coupled isotopic analysis with sequential extractions of streambed sediment. We found that the proportion of weakly-bound Hg within EFPC streambed sediment was relatively small, but could still account for a large proportion of the annual flux of dissolved Hg from EFPC. These sequential extractions also showed that this weakly-bound Hg fraction could be replenished from the much larger fraction of recalcitrant Hg in sediment. The isotopic composition of these weakly-bound and remobilized recalcitrant Hg fractions within the sediment was consistent with high-concentration dissolved Hg hotspots within hyporheic pore water. Thus, this research provided novel evidence that legacy mercury sources within streambed sediment could provide an ongoing contribution of dissolved Hg to surface waters. Finally, we developed new methods for the direct determination of the MeHg isotopic composition of organisms, which allowed a more direct evaluation of inorganic Hg and MeHg sources accumulating in the food web. We found that fish and aquatic invertebrates in both EFPC and a regional background site obtained inorganic Hg and MeHg from multiple isotopically distinct sources, including sediment, suspended particulates, and periphyton. Photodemethylation was found to be an important reaction influencing MeHg dynamics at both sites. However, the balance of microbial methylation and demethylation processes differed between the two streams, with fractionation resulting from methylation and demethylation processes being relatively in balance within the regional background site, whereas microbial methylation appeared to be dominant over microbial demethylation within the EFPC ecosystem. Broadly, the application of Hg isotopic analysis in this study led to numerous novel insights regarding the biogeochemical cycling of Hg in stream ecosystems. This research project promoted the development of two new approaches, including the coupling of sequential extractions with Hg isotopic analysis to assess remobilization of recalcitrant Hg within sediments, and a new method for the isotopic analysis of MeHg isolated from environmental samples. Both of these efforts represent advances in capacity for the field of mercury isotopic analysis and environmental assessment. Overall, this study demonstrates that the application of Hg stable isotope techniques continues to provide new insights into the biogeochemical cycling of Hg in complex aquatic environments, both within the EFPC and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and development of the magnetic diagnostic systems for the first operational phase of the SMART tokamak

A set of magnetic diagnostics has been designed, manufactured, and calibrated for the first operational phase of the small aspect ratio tokamak. The sensor suite comprises of Rogowski coils; 2D magnetic probes; and poloidal, saddle, and diamagnetic flux loops. Here, a set of continuous Rogowski coils has been manufactured for the measurement of plasma current and induced eddy currents in conductive elements. A set of flux loops and magnetic probes will be used as input for the reconstruction of the magnetohydrodynamic equilibrium. The quantity and position of these sensors have been verified to be sufficient with synthetic equilibrium reconstructions using the equilibrium fitting code and baseline scenarios computed with the Fiesta code. These sensors will also be used as input for the real-time control system, and magnetic probes will be used for the detection of plasma instabilities. The calibration procedure for the magnetic probes is described, and the results are shown. The signal conditioning and data acquisition systems are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toroidal Field Reversing Switch

A motor-driven, high-current switch is being designed by Stäubli Electrical Connectors in collaboration with Princeton Plasma Physics Laboratory to reverse the DIII-D Toroidal field coil current. The existing field reversing procedure requires approximately 4 h of labor performed between run days to reconfigure the bus work, thus requiring a separate run day to complete experimental scans with both field directions. This typically results in different wall conditions which complicate the results or make them invalid. The proposed switch will complete the reversal process in approximately 4-5 min, between shots, so that wall conditions are not a factor, and easily fits within the 10-12 min DIII-D shot cycle. The switch is a compact design fitting into a 157.5 × 41 cm envelope. The switch uses two copper pins that slide between Stäubli MULTILAM contacts. The switch is rated for total current of 180-kA dc for 10 s with a 12-min repetition rate; the maximum operating coil current is 124-kA dc. The switch diagnostics include: voltage drop, current monitor, thermal monitors, position sensors, and motor torque. Here, the switch is rated for 300 cycles per year, and 3000 cycles overall before contact replacement, with contact inspection yearly. The design details and operation of the switch are covered in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AutoFocus: AI/ML-driven real-time wavefront diagnostics to autonomously align and optimize X-ray optics

We present an integrated system that combines advanced wavefront diagnostics with artificial intelligence (AI) to automate and optimize X-ray optics at synchrotron beamlines. This system couples real-time wavefront sensing with AI-driven control algorithms to achieve precise beam alignment, stabilization, and performance optimization. A key feature is the use of multi-fidelity transfer learning, which enables knowledge gained from both real-world beamline optimizations and ultra-realistic digital twin simulations to be effectively applied to in situ optimization. By leveraging multi-objective bayesian optimization, the system continuously refines its performance, reducing optimization time and minimizing the need for manual adjustments. Designed for seamless deployment, it operates with existing beamline hardware and provides an intuitive graphical interface. Initial deployments at the advanced photon source beamlines have demonstrated its ability to enhance beam stability, improve reproducibility, and significantly streamline alignment procedures. This AI-enhanced control framework represents a significant step toward fully autonomous beamline operation in next-generation synchrotron facilities.

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Machine Learning-Based Anomaly Detection for PMT Data Quality Monitoring in the SBN and DUNE

Maintaining high-quality detector data is essential for achieving the scientific objectives of the Short-Baseline Neutrino (SBN) Program at Fermilab. Current data quality monitoring (DQM) procedures rely primarily on threshold-based metrics and manual inspection of detector monitoring plots, making the detection of subtle or gradually developing anomalies both time-consuming and dependent on expert interpretation. This project developed and evaluated a machine-learning workflow for automatically identifying anomalous photomultiplier tube (PMT) channels in the Short-Baseline Near Detector (SBND) using optical-hit amplitude data. A Python-based analysis program was developed to process ROOT files, extract statistical features describing individual PMT amplitude distributions, and generate feature vectors for anomaly detection. These features were used to train an Isolation Forest model using data representing normal detector operation. The trained model was subsequently applied to independent detector runs to identify channels exhibiting statistically unusual behavior relative to the learned reference response. To support expert interpretation, the workflow generated complementary diagnostic products, including anomaly score distributions, normalized amplitude comparisons, decision-tree visualizations, and principal component analysis (PCA) projections. This project demonstrated the feasibility of integrating unsupervised machine learning into detector data-quality monitoring and developed a complete workflow for automated PMT performance assessment to aid expert-driven review. Beyond its technical contributions, the VFP appointment fostered a research collaboration between Aurora University and Fermilab and provided direct workforce development benefits by training the visiting faculty member in detector-scale machine-learning methods that are now being incorporated into undergraduate coursework and research. The methodology developed here provides a foundation for future applications to ProtoDUNE and other liquid argon time projection chamber (LArTPC) detectors, contributing to ongoing efforts to improve detector reliability, reduce manual monitoring requirements, and enable scalable data quality monitoring for future large-scale neutrino experiments, including the Deep Underground Neutrino Experiment (DUNE).

Colón Santana, Juan A. [Unlisted, US, IL]↗

First-principles modeling of plasmons in aluminum under ambient and extreme conditions

The theoretical understanding of plasmon behavior is crucial for an accurate interpretation of inelastic scattering diagnostics in many experiments. In this work, we highlight the utility of linear response time-dependent density functional theory (LR-TDDFT) as a first-principles framework for consistently modeling plasmon properties. We provide a comprehensive analysis of plasmons in aluminum from ambient to warm dense matter conditions and assess typical properties such as the dynamical structure factor, the plasmon dispersion, and the plasmon lifetime. We compare our results with scattering measurements and with other TDDFT results as well as models such as the random phase approximation, the Mermin approach, and the dielectric function obtained using static local field corrections of the uniform electron gas parametrized from path-integral Monte Carlo simulations. We conclude that results for the plasmon dispersion and lifetime are inconsistent between experiment and theories and that the common practice of extracting and studying plasmon dispersion relations is an insufficient procedure to capture the complicated physics contained in the dynamic structure factor in its full breadth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-free Rayleigh weight from x-ray Thomson scattering measurements

X-ray Thomson scattering (XRTS) has emerged as a powerful tool for the diagnostics of matter under extreme conditions. In principle, it gives one access to important system parameters such as the temperature, density, and ionization state, but the interpretation of the measured XRTS intensity usually relies on theoretical models and approximations. In this context, a key property is given by the Rayleigh weight that describes the electronic localization around the ions. Here, we show that it is possible to extract the Rayleigh weight directly from the experimental data without the need for any model calculations or simulations. As a practical application, we consider an experimental measurement of strongly compressed Be at the National Ignition Facility [Döppner et al., Nature 618, 270–275 (2023)]. We demonstrate that experimental results for the Rayleigh weight open up new avenues for the interpretation of XRTS experiments by matching the measurement with ab initio simulations such as density functional theory or path integral Monte Carlo. Interestingly, this new procedure leads to significantly lower density compared to previously used chemical models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Multi-fidelity equations of state and transport coefficient datasets for pulsed-power applications

Reliably simulating experiments relevant to the National Nuclear Security Administration (NNSA) requires a detailed description of material properties across a wide range of conditions. Such properties include the equations of state, charged-particle transport coefficients, and optical properties like the opacity. Together, these properties make up the material models used in radiation-magnetohydrodynamic simulations of nuclear fusion experiments. Many of these models do not incorporate uncertainties in the data used to produce them. It is unknown whether these uncertainties significantly impact the interpretation of simulation results and diagnostics. The purpose of this work is to quantify how such uncertainties impact simulations of pulsed-power experiments. We accomplished this task by first assessing discrepancies between approaches used to generate the data. This included bringing together members of the high-energy-density community spanning the three NNSA laboratories and multiple universities. Then, using these data, we developed a general framework that systematically incorporates physical uncertainties within the material models suitable for uncertainty quantification analyses. The framework utilizes machine learning, Bayesian inference, and incorporates multi-fidelity datasets. We demonstrated the framework by quantifying the impact that material model uncertainties have on simulations of pulsed-power experiments underway on Z at Sandia National Laboratories. As a result of this work, we discovered that modest uncertainties in material models (roughly 20%) correspond to significant uncertainties in the outputs from simulations. Our framework has enabled rapid construction of material models through an automated procedure and allows for the generation of material models of interest to the NNSA.

36 MATERIALS SCIENCE↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗

On the anatomy of acoustic emission

Abrupt, local frictional fault failure comprises a displacement that is normally accompanied by acoustic emission (AE)—an impulsive elastic wave broadcast with an amplitude proportional to particle velocity. The aggregate of these displacements is the basic fault motion. In laboratory shear experiments, the examination of a sequence of laboratory earthquakes includes continuous measurements of fault motion and the associated AE that is broadcast. From these measurements, connections between the fault motion and cumulative sum of the AE amplitude can be identified. The composition of the AE broadcasts reveals inhomogeneity in the fault mechanical structure from which they arise. This inhomogeneity can be decomposed into a time invariant AE component and an articulated AE component. The articulated AE component serves as a “state of the fault diagnostic” that follows a distinctive pattern to fault failure. Thus, the articulated AE component can be used directly to monitor the state of the fault.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Case Report: Differential diagnosis of hematuria in the emergency department: emphasizing double J stent-inferior vena cava fistula

Introduction Hematuria, a common clinical indicator of genitourinary tract pathology, arises from diverse etiologies including calculi, infections, malignancies, trauma, and iatrogenic causes. Initial evaluation requires hemodynamic assessment, identification of underlying causes, and urinary drainage optimization. This report highlights a rare case of iatrogenic hematuria secondary to double-J stent migration into the inferior vena cava. Case presentation A Chinese male presented with acute left flank pain and gross hematuria persisting for 4 h. Diagnostic imaging revealed a left ureteral stone, prompting double-J stent placement at a local hospital. Despite intervention, hematuria worsened, necessitating abdominal CT. Imaging identified proximal migration of the left double-J stent into the inferior vena cava, with no evidence of vascular injury. Due to concerns regarding inadequate drainage and infection risk, conservative management without catheter clamping was initiated prior to referral. Definitive treatment involved ureteroscopic stent removal under direct visualization at our institution, resulting in rapid symptom resolution. Conclusion This case emphasizes three critical clinical insights: (1) Persistent postoperative hematuria warrants consideration of iatrogenic causes, particularly following urologic device placement. (2) Imaging modalities, especially CT, are indispensable for detecting atypical stent migration. (3) Comprehensive history-taking must include prior urologic interventions to guide differential diagnosis. While double-J stent migration into major vessels remains exceptionally rare, its recognition prevents delayed management of potentially life-threatening complications. Clinicians should maintain heightened vigilance for device-related hematuria in patients with refractory symptoms post-procedurally, ensuring prompt imaging evaluation and multidisciplinary intervention when indicated.

Qi, Wenqi↗

Modeling Sepsis: Establishment and Validation of a 72-Hour Swine Model of Penetrating Abdominal Trauma

Background/Objectives: Fecal peritonitis following penetrating abdominal trauma is a serious condition that often results in sepsis and organ failure. The aim of our study was to develop a novel conscious porcine model of sepsis and organ dysfunction caused by multiple penetrating injuries to the small and large intestines. Methods: Twelve female Yorkshire pigs (average weight 50.6 ± 6.5 kg) were divided into two groups: Penetrating Abdominal Trauma (PAT) (n = 8) and Control (n = 4). All surgical procedures were performed under anesthesia with adequate analgesia. In the PAT group, the small and large intestines were punctured, and feces mixed with saline were introduced into the abdominal cavity to induce peritonitis. The Control group received sham surgery with only saline solution. The animals were observed in a conscious state over a period of 72 h, vital parameters were recorded, and blood samples were taken regularly. We adapted a pig-specific SOFA score and developed pig-specific SIRS criteria and NEWS2 score to assess organ function. The model was validated by independent investigators. Results: The survival rate in the PAT group was 75%, with an average survival time of 58.5 h, while all animals in the Control group survived to euthanasia. Monitoring showed pathophysiological changes, such as tachycardia, leucopenia, and thrombocytopenia, indicative of sepsis and organ dysfunction. Blinded investigators independently confirmed the model’s validity. Conclusions: A new swine model of penetrating abdominal trauma and sepsis has been successfully developed that demonstrates significant physiological and immunologic changes comparable to human sepsis. This new model provides a realistic platform for future research into sepsis, its diagnostics, and the evaluation of therapeutic strategies.

General & Internal Medicine↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

A digital twin solution for floating offshore wind turbines validated using a full-scale prototype

Abstract. In this work, we implement, verify, and validate a physics-based digital twin solution applied to a floating offshore wind turbine. The digital twin is validated using measurement data from the full-scale TetraSpar prototype. We focus on the estimation of the aerodynamic loads, wind speed, and section loads along the tower, with the aim of estimating the fatigue lifetime of the tower. Our digital twin solution integrates (1) a Kalman filter to estimate the structural states based on a linear model of the structure and measurements from the turbine, (2) an aerodynamic estimator, and (3) a physics-based virtual sensing procedure to obtain the loads along the tower. The digital twin relies on a set of measurements that are expected to be available on any existing wind turbine (power, pitch, rotor speed, and tower acceleration) and motion sensors that are likely to be standard measurements for a floating platform (inclinometers and GPS sensors). We explore two different pathways to obtain physics-based models: a suite of dedicated Python tools implemented as part of this work and the OpenFAST linearization feature. In our final version of the digital twin, we use components from both approaches. We perform different numerical experiments to verify the individual models of the digital twin. In this simulation realm, we obtain estimated damage equivalent loads of the tower fore–aft bending moment with an accuracy of approximately 5 % to 10 %. When comparing the digital twin estimations with the measurements from the TetraSpar prototype, the errors increased to 10 %–15 % on average. Overall, the accuracy of the results is promising and demonstrates the possibility of using digital twin solutions to estimate fatigue loads on floating offshore wind turbines. A natural continuation of this work would be to implement the monitoring and diagnostics aspect of the digital twin to inform operation and maintenance decisions. The digital twin solution is provided with examples as part of an open-source repository.

17 WIND ENERGY↗