Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-ray detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

X-ray observation of a new soft source in Cygnus.

The location of the new X-ray source, designated Cygnus X-6, is discussed. The polycarbonate window counter detected Cyg X-6 only in the pulse-height interval from 0.5 to 1.3 keV. A total of 44 counts was acquired from the source above a diffuse X-ray and non-X-ray background of 18 plus or minus 3 counts. The polycarbonate pulse-height spectrum for Cyg X-6 is presented together with the calculated counter response to three different model source spectra.

Coleman, P. L.↗

Solid state radiographic image amplifiers, part C

The contrast sensitivity of the radiographic amplifiers, both the storage type and nonstorage type, their absolute sensitivity, and the reproducibility of fabrication were investigated. The required 2-2T quality level was reached with the radiographic storage screen. The sensitivity threshold was 100 to 200 mR with 45 to 100 kV filtered X-rays. The quality level of the radiographic amplifier screen (without storage) was 4-4T; for a 6 mm (0.25 in.) thick aluminum specimen, a 1 mm (0.040 in.) diameter hole in a 0.25 mm (0.010 in.) thick penetrameter was detected. Its sensitivity threshold was 2 to 6 mR/min. The developed radiographic screens are applicable for uses in nondestructive testing.

Szepesi, Z.↗

Solar cosmic ray micro-events

To study small discrete solar particle events, it has proven useful to define a special class such that the proton flux at energies greater than 20 MeV exceed 0.0001 protons/sq cm-sec-sr-MeV. These increases are termed microevents. An arbitrary upper limit is placed at 2 X 0.02 protons/sq cm-sec-sr-MeV. By demanding a measurable flux above 20 MeV, a better separation from corotating events is achieved and onset times can in general be determined more precisely. Over an observing period extending from May 1967 through December 1971, approximately 105 events were observed. There are several different sources of these small events. Some are produced by moderate to large solar flares near the east limb or by solar flares on the nonvisible disk of the sun. Others are produced by generally minor solar activity: typically in 1N flare, a group of type 3 radio bursts and a well defined X-ray burst. A significant number of this latter type are accompanied by type 2 radio emission. A small sample of the micro-events can be classified as scatter-free events. For these the distance traveled by the particles before their initial detection at earth is on the order of 1.5 AU and observed rise and decay times are much less than normal. Examples of these general types of micro-events and their solar association are discussed.

Mcdonald, F. B.↗

Discovery of a periodic pulsating binary X-ray source in Hercules from Uhuru.

We have discovered a new pulsating X-ray source with a 1.24-sec period in the constellation Hercules. Analysis of 5 months of data has shown the existence of periodic variations in the intensity of the source and correlated sinusoidal variations in the period of the 1.24-sec pulsations. As in the case of the pulsating X-ray source Cen X-3, we interpret this effect as due to an occulting binary system, with the intensity changes due to occultation of the X-ray source by its companion and with the sinusoidal variations in the period of the 1.24-sec pulsations due to the Doppler effect. In addition, we have observed a longer-time scale cycle in which the source is bright and pulsing for approximately 9 days during which we can observe the 1.7-day occulting, followed by approximately 27 days during which the source is not detected above background on individual 20-sec scans.

Tananbaum, H.↗

Thermochemical Stability of Ca2Yb8(SiO4)6O2 Apatite in Presence of Molten Calcium-Magnesium-Aluminosilicate (CMAS)

Thermochemical stability of ytterbium silicon oxyapatite Ca 2 Yb 8 (SiO 4 ) 6 O 2 (CYbS) in the presence of molten calcium-magnesium aluminosilicate (CMAS) has been investigated at elevated temperatures for consideration as a thermal and environmental barrier coating (T/EBC) material. CYbS apatite powder was synthesized from the constituent oxides via a solid-state reaction method. Hot-pressed apatite substrates were exposed to molten CMAS at 1200, 1300, and 1400 °C for 1, 10, and 50 h. Development of phases in the interaction region of the heat-treated specimens was monitored using scanning electron microscopy, transmission electron microscopy, high-angle annular dark-field imaging, selected area electron diffraction, and energy dispersive x-ray spectroscopy. Monoclinic cyclosilicate Ca 3 Yb 2 (Si 3 O 9 ) 2 formed from interaction of CYbS apatite with CaO in the CMAS melt at the apatite-CMAS reaction front and continued to nucleate and grow within the residual CMAS in diffusion couples annealed for 1 to 50 h at 1200 °C as well as in those heat treated at 1300 °C for 1 h. Residual CMAS was depleted of Ca when cyclosilicate was present. Dendritic wollastonite (CaSiO3) was observed within the residual CMAS in couples annealed at 1200 and 1300 °C. Ingress of molten CMAS, because of its exponential decrease in viscosity, occurred through open pores and along the grain boundaries of the apatite substrates without any detectable chemical reaction at 1300 and 1400 °C. Results of this study indicate that Ca 2 Yb 8 (SiO 4 ) 6 O 2 apatite has the potential to mitigate the CMAS corrosion up to about 1200 °C but not at higher temperatures.

Narottam P Bansal↗

A new X-ray source in the constellation Ara

X ray source GX341-6 with soft spectrum detected in Aras constellation by Aerobee rocket, including neighboring X ray sources in determining galactic coordinates, positions and fluxes

Bunner, A. N.↗

New X-ray star

Pulsating X ray star of Milky Way galaxy detected by SAS-42

Source record↗

Instrumentation for the measurement of high energy phenomena on NASA spacecraft.

High energy astrophysical observations will be conducted primarily from the Small Astronomy Satellites (SAS) and the High Energy Astronomy Observatories (HEAO). The first satellite (SAS A) will carry a set of collimated proportional counters to conduct a high sensitivity, high spatial resolution, all sky survey for X-ray sources. The objective of SAS B will be to search for celestial gamma-ray sources and regions and to measure the flux and energy spectrum of any sources located. A wire grid digitized spark chamber will be the prime detection instrument. The instrumentation of SAS C will consist of modulation collimators, slot collimators, and proportional counters.

Opp, A. G.↗

A sealed titanium window proportional counter for the detection of .5-keV X rays.

A sealed Ti window proportional counter sensitive to X radiation in the energy range 0.35-0.45 keV and above 1.5 keV is described. Measurements of the Ti mass absorption coefficients and a graphical summary of the literature values are presented. For a proportional counter with a 930 microgram/sq cm (2.1-micron) Ti window, the peak efficiency at 0.45 keV is found to lie between 4.6% and 7.1%. An application in X-ray astronomy involving a rocket observation of Sco X-1 is discussed.

Mcclintock, J. E.↗

X-ray emission from the galactic disk.

A search was made for a diffuse component of greater than 1.5 keV X rays associated with an interarm region of the Galaxy at galactic longitudes in the vicinity of 60 degrees. A statistically significant excess associated with a narrow disk component was detected. The angular extent of this component has a most probable value of 2 degrees. The best-fit spectrum yields an intensity of 2.9 photons/sq cm per sec per sterad over the 2-10 keV range. The 3-sigma upper limit to any emission in a 1.5 keV band centered at 7 keV from galactic latitudes not greater than 3.5 deg is 0.3 photons/sq cm per sec per sterad. Several possible emission models are evaluated, with the most likely choice being a population of unresolvable low-luminosity sources.

Bleach, R. D.↗

Conical focusing crystal spectrometers for cosmic X-ray astronomy

A crystal spectrometer for rocket and satellite experiments is described. Parallel X rays from a stellar object are reflected at constant angle by Bragg crystals arranged around the sector of a cone so that a single wavelength is brought to a focus onto the axis of the cone. The aberrations produced when this array is tilted to change the wavelength are considered. It is shown that these are minimized by moving cone and detector in a nearly theta to two-theta motion and by using a small-angle sector. In a specific design for a satellite instrument using LiF crystal to observe a spectral region including the iron lines at 1.9 A, a spectral resolution of 3 mA over a spectral range of 1.6-2.1 A can be obtained, with the cosmic-ray background rate, and hence the time to detect a weak line decreased by a factor 80 compared to a flat crystal spectrometer. Examples of performance for a low energy rocket experiment are also given.

Woodgate, B. E.↗