Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIDEO TAPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Integration of visual and motion cues for simulator requirements and ride quality investigation

Preliminary tests and evaluation are presented of pilot performance during landing (flight paths) using computer generated images (video tapes). Psychophysiological factors affecting pilot visual perception were measured. A turning flight maneuver (pitch and roll) was specifically studied using a training device, and the scaling laws involved were determined. Also presented are medical studies (abstracts) on human response to gravity variations without visual cues, acceleration stimuli effects on the semicircular canals, and neurons affecting eye movements, and vestibular tests.

Young, L. R.↗

Optical Detection of Blade Flutter

Dynamic strain gages mounted on rotor blades are used as the primary instrumentation for detecting the onset of flutter and defining the vibratory mode and frequency. Optical devices are evaluated for performing the same measurements as well as providing supplementary information on the vibratory characteristics. Two separate methods are studied: stroboscopic imagery of the blade tip and photoelectric scanning of blade tip motion. Both methods give visual data in real time as well as video tape records. The optical systems are described, and representative results are presented. The potential of this instrumentation in flutter research is discussed.

Nieberding, W. C.↗

Optical detection of blade flutter

The paper examines the capabilities of photoelectric scanning (PES) and stroboscopic imagery (SI) as optical monitoring tools for detection of the onset of flutter in the fan blades of an aircraft gas turbine engine. Both optical techniques give visual data in real time as well as video-tape records. PES is shown to be an ideal flutter monitor, since a single cathode ray tube displays the behavior of all the blades in a stage simultaneously. Operation of the SI system continuously while searching for a flutter condition imposes severe demands on the flash tube and affects its reliability, thus limiting its use as a flutter monitor. A better method of operation is to search for flutter with the PES and limit the use of SI to those times when the PES indicates interesting blade activity.

Nieberding, W. C.↗

Skylab contamination results: S052 particle analysis and T025 analysis

The size and velocity distributions of 500 contaminant particles in the near environs of Skylab were determined from video tape data obtained by the high altitude observatory's white light coronagraph. A complete listing of derived particle parameters, their frequency distributions, and their behavior as a function of time are presented. A correlation between particle size and velocity is noted, and at least two prominent directions of the particle spacecraft origins are identified.

Schuerman, D. W.↗

Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

Widenor, W. M.↗

Large Area Silicon Sheet by EFG

Progress made in the development of EFG ribbon growth is discussed. Specific areas covered include: (1) demonstration of multiple growth for ribbons 5 cm wide in runs of 12 and 20 hours duration; (2) a single cartridge crystal growth station was built expanding observational capacity by virtue of an anamorphic optical-video system which allows close observation of the meniscus over 7.5 cm wide, as well as video taping of the ribbon growth process; (3) growth station no.1 achieved reproducible and reliable growth of 7.5 cm wide ribbon at speeds up to 4 cm/min; (4) introduction of the 'mini cold shoe'; (5) increases in cell efficiency due to interface shaping using the 'displaced die' concept; and (6) clarification of the role of gaseous impurities in cartridge furnaces and stabilization of their destabilizing influence on growth.

Wald, F. V.↗

Video detection and analysis techniques of transient astronomical phenomena

Low-light-level television systems have been utilized to gain information on meteors, aurorae, and other faint, transient astronomical phenomena. Such phenomena change not only their position as a function of time, but also their photometric and spectral characteristics in as little as 1/60 second, thus requiring unique methods of analysis. Data observed with television systems and recorded on video tape have been analyzed with a system utilizing both analog and digital techniques. Both off-the-shelf equipment and inhouse developments are used to isolate sequences of moving images and to store them in a form suitable for photometric and spectral reduction. Current emphasis of the analysis effort is directed at the measurement of the first-order emission lines of meteor spectra, the results of which will yield important compositional information concerning the nature of the impinging meteoroid.

Clifton, K. S.↗

Static test of a fan-powered chin nozzle for V/STOl applications

The performance of a "chin" nozzle which diverts flow in a downward direction immediately downstream of a fan typical of designs suitable for V/STOL A applications was evaluated. Back pressure distortion to the fan and fan discharge pressure distortion were also measured. Results show that the distortion is significant at the closest spacing between the fan exit and cascade entrance tested, and that the chin nozzle performance deteriorates with increased flow diversion to the chin nozzle. Color oil flow visualization on video tape and still photos were also obtained. Tests were conducted behind a 12" model fan in the NASA-Lewis fan calibration facility.

Salemann, V.↗

Process development for automated solar cell and module production. Task 4: Automated array assembly

The Unimate robot was programmed for the final 35 cell pattern to be used in the fabrication of the deliverable modules. Mechanical construction of the Automated Lamination Station and Final Assembly Station were completed on schedule. All final wiring and interconnect cables were also completed and the first operational testing began. The final controlling program was written. A local fabricator was contracted to produce the glass reinforced concrete panels to be used for testing and deliverables. A video tape showing all three stations in operation was produced.

Hagerty, J. J.↗

Research on electrical properties of severe thunderstorms in the Great Plains

Techniques, equipment, and results of studies (1978-1980) to determine the relationships between electrical phenomena and the dynamics and precipitation of storms are reported. Doppler and conventional radar, video tapes and movies, and VHF recording devices were used to monitor an area 200 x 100 km, aligned SW to NE. The 23 cm radar and a Doppler radar were employed to acquire radar echoes from lightning. Observations of a squall line, a severe storm, and radar echoes from electrical discharges are described. Positively charged cloud-to-ground lightning was observed during the severe and final stages of severe storms; average lightning rates and total flashes for normal and severe storms are provided. Comparisons of lightning echoes and electric field changes indicated that abrupt increases in radar reflectivity were correlated with return strokes and K-type field changes.

Rust, W. D.↗

Analysis of photometric spectra of 17 meteors

The initial phase of the photometry which involved 17 meteor spectra consisting of eight Geminid spectra, six Orionid spectra and three Eta Aquarid spectra is discussed. Among these 17 spectra it is found that the Geminid spectra are of the best quality and are used for the identification of the atomic lines and molecular bands that normally appear on video tape spectra. The data from the Geminid records are used for developing calibration techniques in photometry. The Orionid and Eta Aquarid spectra are chosen for early analysis because of the current interest in all physical and chemical data relating to Comet Halley.

Millman, P. M.↗

Current trends in meteor spectroscopy

The history of progress over more than a century in meteor spectroscopy is summarized. The observational data were originally visual records, but in the beginning of the 20th century photography of meteor spectra was undertaken. In the forties, 60 meteor spectra were photographed. Interest in the upper atmosphere led to the development of more efficient meteor cameras which employ replica gratings, and electronic image intensification systems recordings on video tape which resulted in the availability of several thousand meteor spectra.

Millman, P. M.↗

The effectiveness of incorporating a real-time oculometer system in a commercial flight training program

The effectiveness of incroporating a real-time oculometer system into a Boeing 737 commercial flight training program was studied. The study combined a specialized oculometer system with sophisticated video equipment that would allow instructor pilots (IPs) to monitor pilot and copilot trainees' instrument scan behavior in real-time, and provide each trainee with video tapes of his/her instrument scanning behavior for each training session. The IPs' performance ratings and trainees' self-ratings were compared to the performance ratings by IPs and trainees in a control group. The results indicate no difference in IP ratings or trainees' self-ratings for the control and experimental groups. The results indicated that the major beneficial role of a real-time oculometer system for pilots and copilots having a significant amount of flight experience would be for problem solving or refinement of instrument scanning behavior rather than a general instructional scheme. It is suggested that this line of research be continued with the incorporation of objective data (e.g., state of the aircraft data), measures of cost effectiveness and with trainees having less flight experience.

Jones, D. H.↗

New two-dimensional photon camera

A photon-sensitive camera, applicable to speckle imaging of astronomical sources, high-resolution spectroscopy of faint galaxies in a crossed-dispersion spectrograph, or narrow-band direct imaging of galaxies, is presented. The camera is shown to supply 8-bit by 8-bit photon positions (256 x 256 pixels) for as many as 10 to the 6th photons/sec with a maximum linear resolution of approximately 10 microns. The sequence of photon positions is recorded digitally with a VHS-format video tape recorder or formed into an immediate image via a microcomputer. The four basic elements of the camera are described in detail: a high-gain image intensifier with fast-decay output phosphor, a glass-prism optical-beam splitter, a set of Gray-coded masks, and a photomultiplier tube for each mask. The characteristics of the camera are compared to those of other photon cameras.

Papaliolios, C.↗

The effectiveness of using real-time eye scanning information for pilot training

A study to evaluate the idea of providing pilots feedback on their scan behavior as an instrumentional training aid was conducted jointly by NASA, Piedmont Aviation, and Old Dominion University. The study used Langley's oculometer system to provide a real-time display of the trainee's scan to the instructor pilot in the aft part of the Boeing 737 training simulator at Piedmont. The trainees' scan behavior was also video-taped for viewing by the instructor and trainee after each training session. Based on qualitative data obtained during the study, scan behavior feedback was an effective tool for pilot training.

Spady, A. A., Jr.↗

A Full Mission Simulator Study of Aircrew Performances: the Measurement of Crew Coordination and Decisionmaking Factors and Their Relationships to Flight Task Performances

Sixteen three man crews flew a full mission scenario in an airline flight simulator. A high level of verbal interaction during instances of critical decision making was located. Each crew flew the scenario only once, without prior knowledge of the scenario problem. Following a simulator run and in accord with formal instructions, each of the three crew members independently viewed and commented on a videotape of their performance. Two check pilot observers rated pilot performance across all crews and, following each run, also commented on the video tape of the crew's performance. A linguistic analysis of voice transcript is made to provide assessment of crew coordination and decision making qualities. Measures of crew coordination and decision making factors are correlated with flight task performance measures.

Murphy, M. R.↗

The cognitive connection: Software maintenance and documentation

With the goal of trying to understand what software maintainers do, talking aloud, video taped protocols with four expert maintainers were conducted as they were actively engaged in the process of enhancing a relatively small, interactive database program. The subjects exhibited a number of different types of information gathering strategies. Underlying these patterns of behavior, however, was the use of expectations about what should be seen in the program under examination. These expectations were generated on the basis of knowledge previously acquired as to the goals and programming plans that are typically employed in realizing interactive database programs. Thus, while the experts seemed to posses adequate programming knowledge, their actual code patches violated a basic principle of program structure. This failure by the programmers was attributed to ineffective program documentation. Suggestions for changes in the content of program documentation that should better facilitate software maintenance are presented.

Soloway, E.↗

The great flare of 1982 June 6

The great soft X-ray (SXR) flare (X12) of the past solar maximum was observed by Hinotori and by Big Bear Solar Observatory (BBSO) on June 6, 1982. Hinotori data consist of hard X-ray (HXR) and SXR images in the rise and decay of the flare, high-resolution soft X-ray spectra throughout the flare, and HXR and gamma-ray data. The BBSO data include films of H-alpha, H-alpha blue wing, D3 and longitudinal magnetic field, as well as video tapes of continuum. Images in HXR, SXR, H-alpha, D3 and the continuum are compared and SXR spectra analyzed. The flare resulted from extended motion of a large spot shearing the magnetic field. D3 and white-light images exhibit a progression from fast flashes to two ribbons, while both HXR and SXR are centered on the optical kernels. The continuum emission shows the same temporal behavior as the HXR at 160 keV. In its early phases, the Fe XXV line was double-peaked, and a decreasing blueshifted (up to 400 km/sec) component was observed, from which the evaporation rate of chromospheric material was estimated. It is suggested that this upflow is adequate to supply the coronal cloud. Flare energetics are discussed in detail, and it is concluded that a significant amount of energy was deposited in the corona, and that nonthermal electrons are the major energy input.

Tanaka, K.↗