Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

US LHCNet: Transatlantic Networking for the LHC and the U.S. HEP Community

US LHCNet provides the transatlantic connectivity between the Tier1 computing facilities at the Fermilab and Brookhaven National Labs and the Tier0 and Tier1 facilities at CERN, as well as Tier1s elsewhere in Europe and Asia. Together with ESnet, Internet2, and other R&E Networks participating in the LHCONE initiative, US LHCNet also supports transatlantic connections between the Tier2 centers (where most of the data analysis is taking place) and the Tier1s as needed. Given the key roles of the US and European Tier1 centers as well as Tier2 centers on both continents, the largest data flows are across the Atlantic, where US LHCNet has the major role. US LHCNet manages and operates the transatlantic network infrastructure including four Points of Presence (PoPs) and currently six transatlantic OC-192 (10Gbps) leased links. Operating at the optical layer, the network provides a highly resilient fabric for data movement, with a target service availability level in excess of 99.95%. This level of resilience and seamless operation is achieved through careful design including path diversity on both submarine and terrestrial segments, use of carrier-grade equipment with built-in high-availability and redundancy features, deployment of robust failover mechanisms based on SONET protection schemes, as well as the design of facility-diverse paths between the LHC computing sites. The US LHCNet network provides services at Layer 1(optical), Layer 2 (Ethernet) and Layer 3 (IPv4 and IPv6). The flexible design of the network, including modular equipment, a talented and agile team, and flexible circuit lease management, allows US LHCNet to react quickly to changing requirements form the LHC community. Network capacity is provisioned just-in-time to meet the needs, as demonstrated in the past years during the changing LHC start-up plans.

97 MATHEMATICS AND COMPUTING↗

Plug and Process Loads Capacity and Power Requirements Analysis

This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus of this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How PV system ownership can impact the market value of residential homes

There are multiple ways for a homeowner to obtain the electricity generating and savings benefits offered by a photovoltaic (PV) system. These include purchasing a PV system through various financing mechanisms, or by leasing the PV system from a third party with multiple options that may include purchase, lease renewal or PV system removal. The different ownership options available to homeowners presents a challenge to appraisal and real estate professionals during a home sale or refinance in terms of how to develop a value that is reflective of the PV system s operational characteristics, local market conditions, and lender and underwriter requirements. This paper presents these many PV system ownership options with a discussion of what considerations an appraiser must make when developing the contributory value of a PV system to a residential property.

14 SOLAR ENERGY↗

Data Collection and Validation of Newport Beach Hydrogen Station Performance

The hydrogen fueling station located at 1600 Jamboree Road in Newport Beach, California was designed and built to refuel light duty fuel cell electric vehicles (FCEVs). The station features the on-site generation of hydrogen through a small scale natural gas steam methane reformer (SMR). All the hydrogen related equipment was added to an existing retail gasoline/diesel station. The station is an early demonstration of what the footprint and equipment arrangement of a retail on-site SMR facility might look like. Commercial customer FCEV leases have only just begun in the last two years or so. And, individual Original Equipment Manufacturer (OEM) vehicle lease fleets are relatively small. Only a few hundred FCEVs are on the road in California. As a result, hydrogen throughput is relatively low at the few early pre-commercial hydrogen stations that are currently open. Therefore the stations are underutilized. This project aims to collect additional station data to allow the operator to potentially adjust various operational parameters in order to improve the overall efficiency of the station and lower operation and maintenance costs and to help improve air quality and reduce greenhouse gas emissions. Due to unforeseen delays, technical challenges and personnel reassignments the project was delayed to the point that the award was allowed to expire.

08 HYDROGEN↗

Considerations for Commercial Building Participation in a Transactive Energy: Additional Information on Commercial Buildings

The research done in FY 18 found that there were many factors particularly relevant to the commercial setting that would impact participation and should be considered when evaluating the effectiveness of a Transactive Energy (TE) system. One factor that became a major focus of this research was the ownership and lease structures, commercial real estate databases were used to estimate the percentage of commercial space that may be subject to a lease arrangement that inherently removed the incentive to participate in TE. Other major factors that were discussed were the impacts that participation could have on the production and revenue of a commercial space and how the state of the building and the equipment within it would effect the potential participation. The research on other factors was not discussed at the same level of detail; this addendum aims to analyze some of the other important factors on commercial participation in a TE system with similar rigor.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Federal Workplace Charging Program Guide

This report serves as a program guide to support federal agencies in developing their own policy documents for workplace charging. It provides suggested language that agencies can incorporate into their own policies to define requirements for charging privately owned vehicles (POVs) on government-owned or leased property. The Fixing America's Surface Transportation Act authorizes the U.S. General Services Administration (GSA) and other federal agencies to install, operate, and maintain electric vehicle supply equipment (EVSE) for POVs in parking areas used by federal employees and authorized users, and it requires the collection of fees to recover the costs of installing, operating, and maintaining this equipment. This guide offers details for agency facility managers, transportation personnel, employees, and vendors regarding the charging of electric vehicles (EVs) for use by employees and personnel at government-owned and leased buildings. This guide describes the requirements associated with federal agencies providing EV charging in publicly accessible sites. The policy also describes when and how fees may be imposed to cover costs of electricity, as well as EVSE units and installations in various scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Environmental Effects Assessment for Proposed Offshore Wind Farm off the Coast of Grays Harbor, Washington

Grays Harbor Wind LLC (GHW) is proposing to develop a floating offshore wind farm offshore of west Grays Harbor County, Washington (Grays Harbor). The proposed GHW Offshore Wind Project (Project) would entail construction, installation and operation of a 1,000-megawatt (MW) offshore wind farm consisting of approximately 75 floating units, each containing a floating foundation and wind turbine generator (WTG). The Project location is approximately 25 miles (21.7 nautical miles [nmi]) offshore west of Grays Harbor, at waters depths of 360 to 700 feet. The Pacific Northwest National Laboratory (PNNL) was contracted by Herrera Environmental Consultants, Inc. on behalf of GHW to carry out this preliminary scoping study to evaluate baseline conditions and potential effects on fish and marine mammals from development and operation of a floating offshore wind farm installed within a designated area off the coast of Washington1. Floating offshore wind units installed in an ocean environment as part of the Project would interact with marine wildlife. This Study report provides an initial data aggregation and analysis, using publicly available data, of the Project effects, both negative and positive, on the marine environment. The scope of this assessment is limited by the fact that the Project development is presently at the conceptual level. Data on marine organisms were aggregated and evaluated; however seabirds were evaluated by Herrera Environmental Consulting and, along with bats, were not included in the scope of this study. Significant additional work is necessary to characterize ocean, seafloor, and environmental conditions; select appropriate floating offshore wind technologies; identify construction methods and locations; and assess facility locations, including electrical interconnection. Data aggregation and analysis of seabirds and bats is also needed. Evaluation of the full range of potential environmental effects would be conducted following an award of a lease from the Bureau of Ocean Energy Management (BOEM) as part of the leasing, National Environmental Policy Act (NEPA)/State Environmental Policy Act (SEPA) environmental review and permitting processes. While this initial data aggregation and analysis uses best available public scientific information and current assumptions about the Project configuration, the effects discussed herein are based on the status of review to-date and may change as Project-specific details are developed.

17 WIND ENERGY↗

Coastal Acoustic Buoy for Offshore Wind: Project Synthesis

The population of North Atlantic right whales is critically endangered and their habitat overlaps with offshore windfarm leases. It is therefore imperative that effective mitigation strategies be used to avoid impacts on right whales during the construction of offshore windfarms. The Department of Energy issued FOA Number DE-FOA-0001924 to encourage the development of technology that could monitor large exclusion zones for right whales in order to mitigate potential impact of construction noise on right whales. This report summarizes the past two years of the development and evaluation of the Coastal Acoustic Buoy for Offshore Wind (CABOW) project which aimed to develop technology to monitor large exclusion zones for North Atlantic right whales. Over the course of the project SMRU Consulting have implemented a rigorous design process including comparison of different approaches (e.g., single sensor vs multiple sensors), as well as consideration of placement and timing of acoustic monitoring. We have evaluated critical components of the CABOW system including, reliability, detection range, and bearing accuracy in areas adjacent to offshore windfarm leases in Maryland by conducting 3,536 playbacks of simulated right whale upcalls. The maximum call detection range was 7.5 km when noise was 99 dB re 1µPa rms (50-225 Hz), but this reduced to < 1 km when ambient noise levels were high. Our detection probability in the field was measured as a function of range as well as the source-to-noise level ratio allowing us to build a model to predict the probability of detection under various scenarios (sample size: 3,536 calls x 5 buoys = 17,680). The median bearing error was -0.25° but this is likely an underestimate of error due to experimental design. Using the published recall and precision of the two detectors we implemented in the CABOW system, we estimate that at a recall of 80%, our precision was > 80%, within the range of what we were aiming for in this project. To estimate our exclusion zone false negative and false positive rates, we built a simulation model using the empirical data from our field trial. We modelled three to nine CABOW units placed on the 10 km exclusion zone and estimated our false negative rate to be 1% or less (which was our project goal) and our false positive rate to be between seven and nine percent, slightly above our goal of 5%. However, we also modelled an equivalent PAM system that does not have bearing capabilities and found the false positive rates for that system to be six to eight times higher than the CABOW rate. This higher false positive rate of PAM systems with low spatial information could have significant cost repercussions for offshore wind developers by adding work shutdowns or delays without providing additional protection for right whales. The model we built allows us to explore the placement of PAM systems under various scenarios and will thus help facilitate planning of PAM mitigation systems to meet NOAA Incidental Harassment Authorizations for specific windfarms. We achieved an average system uptime of 98.3%, just below our goal of 99%. The issues that caused these short losses of data have been identified and fixed. Right whale detections and audio clips were typically transferred via radio from the buoys to the base station in two to four seconds. We therefore believe we have developed a highly robust real-time PAM system. Based on the above, we feel we have achieved the stated funding goal of developing a cost-effective and robust real-time PAM system that enables the monitoring of large exclusion zones for right whales during the constructions of offshore windfarms. This should lead to decreased costs and risks for the offshore wind sector while providing robust mitigation for right whales. It is important to state that PAM mitigation will need to be implemented with other mitigation strategies (e.g., visual observers) to provide a complete mitigation strategy to ensure that any effects on right whales from offshore windfarm construction is minimized.

17 WIND ENERGY↗

Federal Workplace Charging Program Guide

The 2015 Fixing America's Surface Transportation (FAST) Act authorizes the installation, operation, and maintenance of electric vehicle supply equipment (EVSE) for the purpose of recharging employees' privately owned vehicles (POVs) under the custody or control of the General Services Administration (GSA) or a Federal agency. It requires the collection of fees to recover the costs of installing, operating, and maintaining this equipment and imposes reporting requirements. This program guide reviews those requirements, excerpts the relevant language in Appendix A, and describes when and how fees may be required to cover costs of electricity, network costs, EVSE units, and installations in various scenarios. This program guide is designed to support Federal agencies developing and refining workplace charging programs for employee POVs. While it provides guidance and best practices, it does not replace agencywide policies or agency-specific legal counsel. It contains a roadmap for agency workplace charging programs and defines roles and responsibilities. This guide explains how to determine the number of POVs likely to charge at a given site and contains a sample employee survey in Appendix B. It reviews EVSE planning, including unit selection and acquisition, charger location(s), accounting for available power capacity, using existing infrastructure, and funding an incentive program. It also discusses the costs associated with EVSE acquisition, installation, and network management. These costs inform the subsequently provided information, which describes how to amortize costs to determine appropriate fees for each charging session. The final two sections of this guide address aspects of ongoing program management that the facility coordinator should consider and the reporting requirements associated with the FAST Act. The insights in this guide are applicable to all agency-owned and GSA-leased buildings or facilities offering the use of EVSE or a 120-volt receptacle for the purpose of recharging an employee's POV. However, the FAST Act requirements typically do not apply to any building or facility operated and maintained by a third-party vendor offering the use of EVSE as part of a commercial building lease unless the agency is managing the station and/or energy on behalf of the building and collecting POV fees.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Vacuum Insulated Panels in a Roofing Application, Camden U.S. Post Office and Courthouse, Camden, New Jersey

The U.S. General Services Administration (GSA) Public Buildings Service (PBS) acquires space on behalf of the Federal Government through new construction and leasing and acts as a steward for federal properties across the country. PBS has jurisdiction, custody, and control over 9,624 federally owned and leased assets and maintains an inventory of more than 370.2 million square feet of workspace and because of this has enormous potential for implementing energy efficient and renewable energy technologies to reduce energy and water use and associated emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occurrence of Low-Level Jets over the Eastern U.S. Coastal Zone at Heights Relevant to Wind Energy

Two years of high-resolution simulations conducted with the Weather Research and Forecasting (WRF) model are used to characterize the frequency, intensity and height of low-level jets (LLJ) over the U.S. Atlantic coastal zone. Meteorological conditions and the occurrence and characteristics of LLJs are described for (i) the centroids of thirteen of the sixteen active offshore wind energy lease areas off the U.S. east coast and (ii) along two transects extending east from the U.S. coastline across the northern lease areas (LA). Flow close to the nominal hub-height of wind turbines is predominantly northwesterly and southwesterly and exhibits pronounced seasonality, with highest wind speeds in November, and lowest wind speeds in June. LLJs diagnosed using vertical profiles of modeled wind speeds from approximately 20 to 530 m above sea level exhibit highest frequency in LA south of Massachusetts, where LLJs are identified in up to 12% of hours in June. LLJs are considerably less frequent further south along the U.S. east coast and outside of the summer season. LLJs frequently occur at heights that intersect the wind turbine rotor plane, and at wind speeds within typical wind turbine operating ranges. LLJs are most frequent, intense and have lowest core heights under strong horizontal temperature gradients and lower planetary boundary layer heights.

17 WIND ENERGY↗

Analysis of Manufacturer Plug-In Electric Vehicle Incentives

Vehicle manufacturers offer incentives in an attempt to encourage consumers to purchase or lease new vehicles. Similarly federal and local governments offer incentives to help build and maintain a market for plug-in electric vehicles. This paper analyzes manufacturer cash rebates and special lease offers and presents a comparison of plug-in electric vehicle incentives by manufacturer, technology, geographic area, and time period. How these manufacturer plug-in electric vehicle incentives relate to vehicle sales as well as state and federal government incentives is also investigated in this study.

33 ADVANCED PROPULSION SYSTEMS↗

Characterization of HRRR-simulated rotor layer wind speeds and clouds along the coast of California

Stratocumulus clouds, with their low cloud base and top, affect the atmospheric boundary layer wind and turbulence profile, thereby modulating wind energy resources. GOES satellite data reveal an abundance of stratocumulus clouds in the late spring and summer months off the coast of northern and central California, where there are active plans to deploy floating offshore wind farms at two lease areas (near Morro Bay and Humboldt). Since the fall of 2020, two buoys equipped with multiple instruments, including Doppler lidar, have been deployed for about 1 year in these wind farm lease areas to assess the rotor layer wind conditions in these locations. The objective of this study is to evaluate how well the High-Resolution Rapid Refresh (HRRR) model represents stratocumulus cloud characteristics and turbine-relevant rotor layer winds (surface to 300 m) by comparing HRRR simulations with buoy and satellite observations. We first find that the HRRR model reproduces the seasonal cycle of cloud top height reasonably well in these regions. However, during the warm season – especially at Morro Bay – the HRRR-simulated stratocumulus clouds tend to have lower tops by about 150 m and exhibit weaker diurnal cycles than satellite observations. Our analysis also shows that rotor layer wind speeds and vertical shear are stronger at Humboldt than at Morro Bay, and both are generally stronger under clear-sky conditions. Finally, the HRRR model bias in rotor layer wind speed is small under cloudy conditions but larger and dependent on observed wind speed under clear skies. Specifically, HRRR underestimates wind speeds at Morro Bay and overestimates them at Humboldt under clear-sky conditions.

17 WIND ENERGY↗

Reference floating wind array designs for three representative regions

This work presents the systematic development of three open-source reference floating wind array designs. The designs are tailored to representative site conditions for three regions of the United States: Humboldt Bay off the coast of California, the Gulf of Maine, and the Gulf of America. We adopted existing reference designs for the individual 15 MW turbines, semisubmersible floating platforms, substations, mooring systems, and power cables – integrating and adapting them as needed for each location. We adapted existing dynamic cable designs to use larger conductor sizes to meet the arrays' power transmission requirements, and we set up redundant mooring systems for each substation. The layout of each array is a uniform-grid design optimized to approximately minimize the levelized cost of energy (LCOE) within a square lease area while satisfying spatial constraints. These constraints ensure adequate clearances between adjacent turbines and between underwater components during the layout optimization to prevent clashing and ensure that all components reside within the lease boundaries. Substations are included to allow accounting for intra-array cable costs. They are placed within the uniform grid to maintain the navigability of the arrays. For each feasible layout considered, annual energy production and cable routing costs are calculated and updated in the LCOE objective function. After the optimization, we refined the cable routing with a mix of algorithmic and manual methods to ensure that the cables avoid mooring system components and approach the substation with adequate clearances. We confirmed the suitability of each reference array's layout by comparing the wake losses at each wind heading angle to the wind rose, observing that the optimized layouts largely avoid wake losses in the predominant wind directions. These reference arrays provide open-source baseline designs to enable future research and innovation of floating wind technology at the array scale.

17 WIND ENERGY↗

Seasonal variability of wake impacts on US mid-Atlantic offshore wind plant power production

Abstract. The mid-Atlantic will experience rapid wind plant development due to its promising wind resource located near large population centers. Wind turbines and wind plants create wakes, or regions of reduced wind speed, that may negatively affect downwind turbines and plants. We evaluate wake variability and annual energy production with the first yearlong modeling assessment using the Weather Research and Forecasting model, deploying 12 MW turbines across the domain at a density of 3.14 MW km−2, matching the planned density of 3 MW km−2. Using a series of simulations with no wind plants, one wind plant, and complete build-out of lease areas, we calculate wake effects and distinguish the effect of wakes generated internally within one plant from those generated externally between plants. We also provide a first step towards uncertainty quantification by testing the amount of added turbulence kinetic energy (TKE) by 0 % and 100 %. We provide a sensitivity analysis by additionally comparing 25 % and 50 % for a short case study period. The strongest wakes, propagating 55 km, occur in summertime stable stratification, just when New England's grid demand peaks in summer. The seasonal variability of wakes in this offshore region is much stronger than the diurnal variability of wakes. Overall, yearlong simulated wake impacts reduce power output by a range between 38.2 % and 34.1 % (for 0 %–100 % added TKE). Internal wakes cause greater yearlong power losses, from 29.2 % to 25.7 %, compared to external wakes, from 14.7 % to 13.4 %. The overall impact is different from the linear sum of internal wakes and external wakes due to non-linear processes. Additional simulations quantify wake uncertainty by modifying the added amount of turbulent kinetic energy from wind turbines, introducing power output variability of 3.8 %. Finally, we compare annual energy production to New England grid demand and find that the lease areas can supply 58.8 % to 61.2 % of annual load. We note that the results of this assessment are not intended to make nor are they suitable to make commercial judgments about specific wind projects.

17 WIND ENERGY↗

WIND Toolkit Offshore Summary Dataset

This dataset contains summary statistics for offshore wind resources for the continental United States derived from the Wind Integration National Datatset (WIND) Toolkit. These data are available in two formats: GDB - Compressed geodatabases containing statistical summaries aligned with lease blocks (aliquots) stored in a GIS format. These data are partitioned into Pacific, Atlantic, and Gulf resource regions. HDF5 - Statistical summaries of all points in the offshore Pacific, Atlantic, and Gulf offshore regions. These data are located on the original WIND Toolkit grid and have not been reassigned or downsampled to lease blocks. These data were developed under contract by NREL for the Bureau of Oceanic Energy Management (BOEM).

17 WIND ENERGY↗

Economical ground data delivery

Data delivery in the Deep Space Network (DSN) involves transmission of a small amount of constant, high-priority traffic and a large amount of bursty, low priority data. The bursty traffic may be initially buffered and then metered back slowly as bandwidth becomes available. Today both types of data are transmitted over dedicated leased circuits. The authors investigated the potential of saving money by designing a hybrid communications architecture that uses leased circuits for high-priority network communications and dial-up circuits for low-priority traffic. Such an architecture may significantly reduce costs and provide an emergency backup. The architecture presented here may also be applied to any ground station-to-customer network within the range of a common carrier. The authors compare estimated costs for various scenarios and suggest security safeguards that should be considered.

Markley, Richard W.↗

The Conference Proceedings of the 1998 Air Transport Research Group (ATRG) of the WCTR Society

Contents include the following: Airport choice in a multiple airport region: an empirical analysis for the San Francisco bay area. Liberalization of the westeuropian aviation: choice of a new hub airport for an airline. Austin Bergstrom airport traffic control tower establishment of a major activity level tower. A study to optimize the environmental capacity of Amsterdam airport schiphol.Airport performance in stakeholder involvement and communication strategies: a comparison of major Australian and North American air carrier and general aviation airports. Airport planning and location.Location of international airport and regional development. A simulation technique for analysis of Brasilian airport passanger terminal building.Multimodal airport access in Japan. Planning surface access provision at major airports Airline economics and the inclusion of environmental costs on airport hub pricing: a theoretical analysis. Airport financing and user charge systems in the USA. Optimal demand for operating lease of aircraft. Aircraft leasing industry and social welfare.The development of performance indicators for airports: a management perspective. Study about operational effect of the "security check-in" implantation in Brasilian international airports.Austin Bergstrom west loop cable system.and Optimal resource allocation model for airport passanger terminals.

Oum, Tae Hoon↗