Synchronization experiment for a time division multiple access satellite communication system
Doppler compensation for maintaining signal synchronization of time division multiple access
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Doppler compensation for maintaining signal synchronization of time division multiple access
Time division multiplexer with magnetic latching relays
Three types of head-up display format are investigated. Type 1 is an unreferenced (conventional) flight director, type 2 is a ground referenced flight path display, and type 3 is a ground referenced director. Formats are generated by computer and presented by reflecting collimation against a simulated forward view in flight. Pilots, holding commercial licenses, fly approaches in the instrument flight mode and in a combined instrument and visual flight mode. The approaches are in wind shear with varied conditions of visibility, offset, and turbulence. The displays are equivalent in pure tracking but there is a slight advantage for the unreferenced director in poor conditions. Flight path displays are better for tracking in the combined flight mode, possibly because of poor director control laws and the division of attention between superimposed fields. Workloads is better for the type 2 displays. The flight path and referenced director displays are criticized for effects of symbol motion and field limiting. In the subjective judgment of pilots familiar with the director displays, they are rated clearly better than path displays, with a preference for the unreferenced director. There is a fair division of attention between superimposed fields.
The control parameters are defined which are to be used by the Photographic Technology Division for the processing of all films flown on Apollo Mission J-3. The procedures necessary for establishment of processing control are given along with information for denoting and solving any problem areas or conflicts which may occur prior to the mission.
The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 3,200 new measurements from 903 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 118 reviews are updated, including many that are heavily revised.
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing
Abstract Understanding the chemistry of the inert actinide oxo bond in actinyl ions AnO 2 2+ is important for controlling actinide behavior in the environment, during separations, and in nuclear waste (An=U, Np, Pu). The thioether calixarene TC4A (4‐ tert ‐butyltetrathiacalix[4]arene) binds equatorially to the actinyl cation forming a conical pocket that differentiates the two trans‐ oxo groups. The ‘ate’ complexes, [A] 2 [UO 2 (TC4A)] (A=[Li(DME) 2 ], HNEt 3 ) and [HNEt 3 ] 2 [AnO 2 (TC4A)] (An=U, Np, Pu), enable selective oxo chemistry. Silylation of the U VI oxo groups by bis(trimethylsilyl)pyrazine occurs first at only the unencapsulated exo oxo and only one silylation is needed to enable migration of the endo oxo out of the cone, whereupon a second silylation affords the stable U IV cis‐ bis(siloxide) [A] 2 [U(OSiMe 3 ) 2 (TC4A)]. Calculations confirm that only one silylation event is needed to initiate oxo rearrangement, and that the putative cis dioxo isomer of [UO 2 (TC4A)] 2− would be stable if it could be accessed synthetically, at only 23 kcal.mol −1 in energy above the classical trans dioxo. Calculations for the transuranic cis [AnO 2 (TC4A)] 2− (An=Np, Pu) are at higher energies, 30–35 kcal.mol −1 , retaining the U complexes as the more obvious target for a cis ‐dioxo actinyl ion. The aryloxide (OAr) groups of the macrocycle are essential in stabilizing this as‐yet unseen uranyl geometry as further bonding in the TC4A U‐O Ar groups stabilizes the U=O ‘yl’ bonds, explaining the stability of the putative cis [UO 2 (TC4A)] 2− in this ligand framework.
The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions.
Pressure-division system for vacuum ionization gauge calibration
The theory of rotating ion exospheres in dipolar magnetic field geometries is used to predict certain effects of the rings on the inner plasmaspheres of the ringed planets Jupiter, Saturn, and Uranus. The analysis here assumes a purely ionospheric source. It is found that if rings affect only the trapped plasma, the cold plasma density at Saturn will be either reduced or increased by a factor of approximately 2 at L = 1.65, depending on whether the ring populates or empties the trapped trajectories. It is found that if all cold plasma particles on trapped orbits are absorbed and the rings are not a source of plasma, this simple exospheric theory can explain the ionospheric density profile inferred from the Pioneer 11 Saturn radio occultation experiment, in which a localized peak in the profile was observed on field lines threading the Guerin division between the C and D rings.
High-accuracy optical systems for implementing digit-serial computations are discussed which incorporate parallelism and carry-free addition to achieve high processing speed. Employing on-line arithmetic, parallel calculations can be performed by the concurrent execution of operations. The algorithms are shown to be problem invariant and step invariant. Architectures using optical bistable devices and optical interconnects are discussed which can implement digit-serial addition, subtraction, multiplication, and division algorithms via the present approach.
Development of MEMS (Microelectromechanical Systems) micropropulsion at the Jet Propulsion Laboratory (JPL) is reviewed. This includes a vaporizing liquid micro-thruster for microspacecraft attitude control, a micro-ion emgine for microspacecraft primary propulsion or large spacecraft fine attitude control, as well as several valve studies, including a solenoid valve studied in collaboration with Moog Space Products Division, and a piezoelectric micro-valve.
With the increasing installation of marine renewable energy (MRE) devices in areas already subject to multiple anthropogenic activities and environmental changes, it is necessary to develop tools and methods for the integrated management of marine ecosystems. The ecosystem approach is a holistic environmental management method that considers all components of an ecosystem. The ecosystem approach has demonstrated utility in the application to various anthropogenic activities and is relevant for consideration within the context of MRE. Indeed, many of the effects observed on marine ecosystems from those other activities are also applicable to MRE development. This review is an initial assessment where we summarize the potential effects of MRE development on marine ecosystems and propose schematic frameworks for applying the ecosystem approach to MRE. We also provide a non-exhaustive list of commonly used models pertinent to the ecosystem approach and associated with several reference studies. An outline of core questions that can currently be answered using available modeling tools central to the ecosystem approach is provided, along with recommendations for the application of this approach to the MRE context. Further, we identify key knowledge gaps and areas that require additional investigation for meaningful application of the ecosystem approach to MRE development. Our recommendations mainly concern the current limitations of applying the ecosystem approach to concrete cases, such as consolidating knowledge of the effects of MRE on the local environment, the need to obtain fine-scale data, considering effects at different spatiotemporal scales, and, finally, the need for an interdisciplinary vision.
Cambridge Heart, Inc., has licensed the only U.S. Food and Drug Administration-cleared tool to identify those at risk for sudden cardiac death (SCD). The Microvolt T-Wave Alternans Test(TM) was invented by Dr. Richard J. Cohen, a professor at the Harvard-Massachusetts Institute of Technology (MIT) Division of Health Sciences and Technology, with developmental support and funding from NASA's Johnson Space Center and the National Space Biomedical Research Institute (NSBRI) in Houston, Texas. In 1993, MIT licensed the technology to Cambridge Heart, Inc., a start-up company that Dr. Cohen helped to establish. Cambridge Heart's non-invasive technology measures T-wave alternans, a change from one heartbeat to the next that is too minute to be detected by a standard electrocardiogram. Cardiac patients with such a change in heartbeat regulation are faced with a much greater risk of ventricular arrhythmia and SCD than those without it. The company's ability to measure electrical alternans on a microvolt level has been clinically proven to be just as accurate as - and in some studies, more accurate than - more costly and somewhat risky, invasive procedures, such as electrophysiological testing.
A method for use in the design of a complex engineering system by decomposing the problem into a set of smaller subproblems is presented. Coupling of the subproblems is preserved by means of the sensitivity derivatives of the subproblem solution to the inputs received from the system. The method allows for the division of work among many people and computers.
Baseband processing (BBP) system for advanced satellite communications successfully demonstrated. Provides increased data capacity through frequency-reusing multibeam antenna systems, using time-division multiple access (TDMA) and onboard satellite switching. Large numbers of thin-route trunking stations and user-based Earth terminals handled efficiently by satellite baseband switching. With BBP system, satellite routes data messages individually among locations anywhere in continental United States. Processes, controls, and routes message traffic among users. Time-division multiple access and baseband switching used.
In this paper we present a peer-to-peer sensor network architecture using space-division optical retro-reflector to provide energy efficient communication services for in-situ science applications.
Explore the source record for details and available documents.