Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Ion-Depleted Microenvironments During Lithium Deposition Revealed by Operando Freezing Cryogenic Electron Microscopy

Local structures and chemistry at active electrochemical interfaces are critical to determining safety, lifetime, and energy density in lithium metal batteries and other devices, but they are challenging to characterize at the nanoscale. We address this issue by developing operando freezing cryogenic electron microscopy (cryo-EM) to preserve battery interfaces in an active state for subsequent high-resolution characterization. We find that ion-depleted microenvironments form locally in the electrolyte adjacent to the lithium deposition interface in lithium metal batteries and are linked to heterogenous growth morphologies. These depleted environments arise locally even under conditions for which ion depletion is not predicted at steady state; this provides a mechanistic explanation for why dangerous lithium morphologies can still propagate in such systems and lead to thermal runaway. Operando freezing cryo-EM thus provides a method to directly visualize nanoscale heterogeneities that arise locally at electrochemical interfaces and play key roles in device failure.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,E↗

Structural and Mechanical Analysis of Individual Mineralized Collagen Fibrils Using In Situ Transmission Electron Microscopy

Bone serves as an example of nature’s architectured material with its characteristic blend of strength and toughness, all at a lightweight design. Given the hierarchical nature of these materials, it is essential to understand the governing mechanisms and organization of their constituents across length scales for bioinspired structural design. Despite recent advances in transmission electron microscopy (TEM) that have allowed us to witness the hierarchical arrangement of bone at micro-down to the nanoscale, we are still missing the details about the structural organization and mechanical properties of the main building blocks of bone─mineralized collagen fibrils (MCFs). Here, we present a method to extract individual MCFs from nature’s model material, mineralized turkey leg tendon, using a dropcasting procedure. By isolating the MCFs onto TEM supporting grids, we visualized the arrangement of organic and mineral phases within individual MCFs at the nanoscale. Using a four-dimensional scanning transmission electron microscopy (4D-STEM) approach, the orientation of individual mineral crystals within the MCFs was examined. Furthermore, we conducted in situ tensile experiments, revealing exceptional tensile strains of at least 8%, demonstrating the intricate relationship between structural organization and the mechanical behavior of MCFs. These insights into the ultrastructure of mineralized tissue building blocks, as well as the proposed sample-extraction method compatible with in situ mechanical testing, provide a strong basis for research into nature-inspired material design.

4D-STEM↗

Experiment K-7-18: Effects of Spaceflight in the Muscle Adductor Longus of Rats Flown in the Soviet Biosatellite Cosmos 2044: A Study Employing Neural Cell Adhesion Molecules (N-CAM) Immunocytochemistry and Conventional Morphological Techniques (Light and Electron Microscopy) - Part 1

The effects of spaceflight upon the 'slow' muscle adductor longus was examined in rats flown in the Soviet Biosatellite COSMOS 2044. Three groups - synchronous, vivarium and basal served as controls. The techniques employed included standard methods for light microscopy, N-CAM immunocytochemistry and electron microscopy. Light microscopic observations revealed myofiber atrophy, contraction bands and segmental necrosis accompanied by cellular infiltrates composed of macrophages, leucocytes and mononuclear cells. N-CAM immunoreactivity was seen (N-CAM-IR) on the myofiber surface, satellite cells and in regenerating myofibers reminiscent of myotubes. Ultrastructural alterations included Z band streaming, disorganization of myofibrillar architecture, sarcoplasmic degradation, extensive segmental necrosis with preservation of the basement membrane, degenerative phenomena of the capillary endothelium and cellular invasion of necrotic areas. Regenerating myofibers were identified by the presence of increased amounts of ribosomal aggregates and chains of polyribosomes associated with myofilaments that displayed varied distributive patterns. The principal electron microscopic changes of the neuromuscular junctions consisted of a decrease or absence of synaptic vesicles, degeneration of axon terminals, increased number of microtubules, vacant axonal spaces and axonal sprouting. The present observations indicate that major alterations such as myofibrillar disruption and necrosis, muscle regeneration and denervation and synaptic remodeling at the level of the neuromuscular junction may take place during spaceflight.

Daunton, N. G.↗

Polarization-dependent photoemission electron microscopy for domain imaging of inorganic and molecular materials

Polarization-dependent photoemission electron microscopy (PD-PEEM) exploits spatial variation in the optical selection rules of materials to image domain formation and material organization on the nanoscale. In this Perspective, we discuss the mechanism of PD-PEEM that results in the observed image contrast in experiments and provide examples of a wide range of material domain structures that PD-PEEM has been able to elucidate, including molecular and polymer domains, local electronic structure and defect symmetry, (anti)ferroelectricity, and ferromagnetism. As a result, we discuss challenges and new directions that are possible with this tool for probing domain structure in materials, including investigating the formation of transient ordered states, multiferroics, and the influence of molecular and polymer order and disorder on excited state dynamics and charge transport.

36 MATERIALS SCIENCE↗

Structural Complexities in Sodium Ion Conductive Antiperovskite Revealed by Cryogenic Transmission Electron Microscopy

Here we use low-dose cryogenic transmission electron microscopy (cryo-TEM) to investigate the atomic-scale structure of antiperovskite Na 2 NH 2 BH 4 crystals by preserving the room-temperature cubic phase and carefully monitoring the electron dose. Via quantitative analysis of electron beam damage using selected area electron diffraction, we find cryogenic imaging provides 6-fold improvement in beam stability for this solid electrolyte. Cryo-TEM images obtained from flat crystals revealed the presence of a new, long-range-ordered supercell with a cubic phase. The supercell exhibits doubled unit cell dimensions of 9.4 Å × 9.4 Å as compared to the cubic lattice structure revealed by X-ray crystallography of 4.7 Å × 4.7 Å. The comparison between the experimental image and simulated potential map indicates the origin of the supercell is a vacancy ordering of sodium atoms. This work demonstrates the potential of using cryo-TEM imaging to study the atomic-scale structure of air- and electron-beam-sensitive antiperovskite-type solid electrolytes.

36 MATERIALS SCIENCE↗

Mudrocks examined by backscattered electron microscopy

A method of studying mudrocks is developed using backscattered electrons (BSE) in scanning electron microscopy. Commercially available detectors are utilized to mix the BSE and secondary electron signals in order to obtain the optimum image for a particular material. Thin sections or polished rock chip surfaces are examined with BSE which provides both the atomic number contrast and topographic contrast. This technique provides very detailed information about the form and composition of individual grains in the mudrock thin sections and can be used in studies of the source, mode of deposition, diagenesis, and tectonic deformational history of mudrocks.

Pye, K.↗

Mineralization of collagen may occur on fibril surfaces: evidence from conventional and high-voltage electron microscopy and three-dimensional imaging

The interaction between collagen and mineral crystals in the normally calcifying leg tendons from the domestic turkey, Meleagris gallopavo, has been investigated at an ultrastructural level with conventional and high-voltage electron microscopy, computed tomography, and three-dimensional image reconstruction methods. Specimens treated by either aqueous or anhydrous techniques and resin-embedded were appropriately sectioned and regions of early tendon mineralization were photographed. On the basis of individual photomicrographs, stereoscopic pairs of images, and tomographic three-dimensional image reconstructions, platelet-shaped crystals may be demonstrated for the first time in association with the surface of collagen fibrils. Mineral is also observed in closely parallel arrays within collagen hole and overlap zones. The mineral deposition at these spatially distinct locations in the tendon provides insight into possible means by which calcification is mediated by collagen as a fundamental event in skeletal and dental formation among vertebrates.

NASA Discipline Musculoskeletal↗

An integrated approach to examine fuel-cladding chemical interaction in HT9/U-10Zr metallic fast reactor fuels: Coupling machine learning with electron microscopy and local mechanical properties analysis

The metallic U-Zr nuclear fuel alloy has garnered renewed interest as a promising candidate for next-generation sodium-cooled fast reactors. Recent studies and technology assessments have identified several areas requiring improvements, enhanced knowledge, and reliable data to strengthen the U-Zr fuel design basis for qualification and commercial applications. One of the most challenging phenomena impacting this fuel system’s performance is fuel-cladding chemical interaction (FCCI). This work aimed to harvest FCCI data by examining selected HT9/U-10Zr (wt. %) fuel samples of prototypic full-length fuel pins through an integrated approach. This approach integrated scanning electron microscopy (SEM) microstructure characterization with localized mechanical properties examination to deepen understanding of FCCI phenomenon in HT9/U-10Zr fuel system. Particularly, this study focused on MFF fuel pins irradiated at Fast Flux Test Facility (FFTF), which aimed to qualify metallic fuel as a driver fuel for FFTF and to assess its viability for larger-scale fast reactors. Electron microscopy provided high confidence in detecting and distinguishing the different FCCI layers, while small-scale mechanical testing (SSMT) probed the mechanical properties of these layers. SEM examination of a MFF-2 pin 192167, with a time averaged inner cladding temperature (TICT) slightly over 500°C, revealed minimal cladding-side FCCI (cladding wastage). In contrast, significantly thicker cladding wastage comprising two distinct sublayers was observed in samples from the thermally hot MFF-3 pin 193045 and MFF-5 pin 195011 where the TICT ranged from 610-635°C. SSMT indicated complete embrittlement in the sublayer adjacent to the fuel and a tendency toward embrittlement in the other sublayer. Additionally, a new machine learning method was developed, validated, and used to quantify cladding wastage thickness. The machine learning method reliably predicted the wastage thickness across various fuel pins and sample cross-sections. Furthermore, the available cladding wastage data from HT9/U-10Zr fuel system demonstrated a strong temperature dependency. However, the dataset remains small, and ongoing research activities are essential to further understand the FCCI phenomenon and develop a reliable FCCI model for enhanced fuel performance simulation under various conditions.

36 - MATERIALS SCIENCE↗

Effects of spaceflight in the adductor longus muscle of rats flown in the Soviet Biosatellite COSMOS 2044. A study employing neural cell adhesion molecule (N-CAM) immunocytochemistry and conventional morphological techniques (light and electron microscopy)

The effects of spaceflight upon the "slow" muscle adductor longus were examined in rats flown in the Soviet Biosatellite COSMOS 2044. The techniques employed included standard methods for light microscopy, neural cell adhesion molecule (N-CAM) immunocytochemistry and electron microscopy. Light microscopic observations revealed myofiber atrophy and segmental necrosis accompanied by cellular infiltrates composed of macrophages, leukocytes and mononuclear cells. Neural cell adhesion molecule immunoreactivity (N-CAM-IR) was seen on the myofiber surface and in regenerating myofibers. Ultrastructural alterations included Z band streaming, disorganization of myofibrillar architecture, sarcoplasmic degradation, extensive segmental necrosis with apparent preservation of the basement membrane, degenerative phenomena of the capillary endothelium and cellular invasion of necrotic areas. Regenerating myofibers were identified by the presence of increased amounts of ribosomal aggregates and chains of polyribosomes associated with myofilaments. The principal electron microscopic changes of the neuromuscular junctions showed axon terminals with a decrease or absence of synaptic vesicles replaced by microtubules and neurofilaments, degeneration of axon terminals, vacant axonal spaces and changes suggestive of axonal sprouting. The present observations suggest that alterations such as myofibrillar disruption and necrosis, muscle regeneration and denervation and synaptic remodeling at the level of the neuromuscular junction may take place during spaceflight.

NASA Experiment Number COS 2044-10↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

Quantitative Structure Determination from Experimental Four-Dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix

Considerable inroads have recently been made on algorithms to determine the sample potential from four-dimensional scanning transmission electron microscopy data from thick samples where multiple scattering cannot be neglected. This paper further develops the scattering matrix approach to such structure determination. Through simulation, we demonstrate how this approach can be modified to better handle partial spatial coherence, unknown probe defocus, and information from the dark field region. By combining these developments we reconstruct the electrostatic potential of a monolithic SrTiO 3 crystal showing good quantitative agreement with the expected structure.

4D STEM↗

Histological preparation of developing vestibular otoconia for scanning electron microscopy

The unique nature of vestibular otoconia as calcium carbonate biominerals makes them particularly susceptible to chemical deformation during histological processing. We fixed and stored otoconia from all three otolith endorgans of embryonic, hatchling and adult Japanese quail in glutaraldehyde containing either phosphate or non-phosphate buffers for varying lengths of time and processed them for scanning electron microscopy. Otoconia from all age groups and otolith endorgans processed in 0.1 M phosphate buffer (pH 7.4) showed abnormal surface morphology when compared to acetone fixed controls. Otoconia processed in 0.1 M sodium cacodylate or HEPES buffered artificial endolymph (pH 7.4) showed normal morphology that was similar to controls. The degree of otoconial deformation was directly related to the time exposed to phosphate buffer. Short duration exposure produced particulate deformations while longer exposures resulted in fused otoconia that formed solid sheets. Otoconial surface deformation and fusing was independent of the glutaraldehyde component of the histological processing. These findings should help vestibular researchers to develop appropriate histological processing protocols in future studies of otoconia.

Non-NASA Center↗

Direct Probing of Radiolysis Chemistry in the Gas Cell Electron Microscopy

Here, the radiolytic decomposition of materials is inevitable in electron microscopy, alongside knock-on effects, electrical charging, and heating damage. Especially with the radiation-susceptible chemistry in the fluidic phase (liquid and gas), consideration of mitigating or leveraging these phenomena is particularly important.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗